SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

Similar documents
SX-FOSC-D-48 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual

UAB Žaliasis namas,draugystės g.19, LT-51230,Kaunas. Horizontal Fiber Optic Splice Closure (FOSC) HTSC-101 (OMH-101) Installation Manual

HY-10-H 48 cores Horizontal Fiber Optic Splice Closure

RN Optical Termination Panel (RN OTP)

SPECIFICATION OPTICAL TERMINATION PANEL

FIBER OPTIC SPLICE CLOSURE

SPECIFICATION OPTICAL TERMINATION BOX for FTTx

Best Construction Practices and Splicing for Fiber Networks

Electrical Isolation

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

ROOF MOUNT KIT OWNERS MANUAL

CABLE TERMINALS CABLE TERMINALS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

LK Wallbox UNI Push X16 V2

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

ROOF MOUNT KIT OWNERS MANUAL

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

L-JACK Termination Procedure

C.R. LAURENCE CO., INC. Intelli-Track SPS. Phase One - Installation Instructions

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE

San Antonio Water System Standard Specifications for Construction ITEM NO. 812 WATER MAIN INSTALLATION

Industrial flue gas probes. Instruction manual

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

IP68 Quick connection system. IP68 Quick connection system

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES

DETAIL INSTRUCTION No. 1

OPTICAL SPLICE CLOSURE for OPGW cables

SECTION PACKAGE BOOSTER PUMP STATIONS

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

VERsacourt LED Light System Installation Instructions

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION CHAIN LINK FENCING

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F FutureFLEX. FIELD TERMINATION KIT PROCEDURE FOR FTFLD24 900µm SUB-UNIT KIT

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

Quality. Reliability. Durability.

STANDARD TECHNIQUE: OH4K/1

DETAIL SPECIFICATION SHEET INTERCONNECTING BOX, FIBER OPTIC, SPLICE TRAY HOLDER MODULE, 8 TRAY

12-SDMS-01 Rev.02 SPECIFICATIONS FOR

SECTION ALUMINUM HANDRAIL SYSTEMS

PERFORMANCE SPECIFICATION SHEET

SECTION STRUCTURAL METAL FRAMING

Operating Instructions

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

Luna - design arch. Valenti

Product Catalogue Telecommunication Hardware

R L POINT WIND CONE PWC FAA [-806 PWC-8061 L HTED LIGHTING ASSEMBLY 4 FLOODLIGHTS OPTION: FE FLOOR FLANGE. // PL Floor Flange

DETAIL SPECIFICATION SHEET INTERCONNECTING BOX, FIBER OPTIC, FUSION SPLICE TRAY AND TRAY HOLDER MODULE

Maelstrom. Installation and Specification Guide

5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

SECTION ORNAMENTAL ALUMINUM RAILING

Universal Elevator Mount Owners Manual

Design & Installation Manual

SECTION CHAIN LINK FENCES AND GATES (PARK)

Reenterable PST Dome Closure

JONES AIRWAY, LLC CLEVELAND REGIONAL JETPORT SECTION STRUCTURAL STEEL

CEG-200. Industrial X-Ray Tube

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

SECTION FIELD PANELS

15~35KV Termination Kit

3.2 SuperTie 50K Installation Guide

Utilities Industry. General Information. Products and Services APPLICATIONS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SPECIFICATION FOR SIMPLEX SWITCHBOARDS

5485HT 5650H 5660H 5660HTS 5665HTS Instruction Kit Same Deutz-Fahr Flow Sensor 5SW models Flow Sensor 6SW models

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

EIU 105 Types of Non-Electrical Insulation Materials

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION INSULATED WIRE AND CABLE

EXIRA EXPOSED PIPE SHOWER INSTALLATION

TERMS OF REFERENCE. Supply and Delivery of Prefabricated Wind Noise Reduction Systems (WNRS) and Equipment Vaults

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

General Specification

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

TUFF-SEAL RSR SERIES ALUMINUM CORD GRIPS. Toll Free Fax RSR Series Straight Aluminum Cord Grips G 1

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

SPECIAL SPECIFICATION 1924 Neighborhood Friendly High Mast Illumination System

FIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

overhead and underground power equipment ISSUE 28 AUGUST / SEPTEMBER 2013 / OHUG.COM OHUG WINS BEST TRADE STAND AT EEA FOR THE SECOND YEAR IN A ROW!

Modular Coldroom Installation Manual

SECTION OVERHEAD COILING SHUTTERS

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

Terrain HDPE. Product Guide

SCHÄFER / MEGOMAT MACHINE SERIES

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

SECTION OVERHEAD CONDUCTOR RAIL

CFFWA-XX-1-U. Rev. 1.2

GR-771-CORE Generic Requirements for Fiber Optic Splice Closures Issue 2, July 2008 Performance Requirements and Objectives

Outdoor. Broadband Communications standard. 1. Cable Construction

CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Broadband Communications

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

Transcription:

SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) Installation Manual

1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation. The scope of application is: aerial, underground, pipeline, hand-holes. The ambient temperature ranges from -40 to 65. 2. Basic structure and configuration 2.1 Dimension and capacity Outside dimension (Height x Diameter) Weight (excluding outside box) Number of inlet/out ports Diameter of fiber cable Capacity of FOSC 540mm 205mm 3000 g 3600g 4 pieces in general Φ8mm~Φ36mm Bunchy:24-96 (cores), Ribbon: up to 288 (cores) 2.2 Main components No. Name of components 1 FOSC cover 2 Fiber optic splice tray (FOST) 3 Base 4 Plastic hoop 5 Seal fitting 6 Pressure testing valve 7 Earthing deriving device Quantity Usage Remarks 1 piece Protecting fiber cable Height x Diameter splices in whole 450mm x 170mm Max. 4 trays Fixing heat shrinkable Suitable for: (bunchy) protective sleeve and Bunchy: 24(cores) Max.: 4 trays holding fibers Ribbon: 12 (pieces) (ribbon) 1set Fixing internal and external structure 1 set Fixing between FOSC cover and base 1 piece Sealing between FOSC cover and base 1 set After inject air, it is used for Configuration as per pressure testing and sealing requirement testing 1 set Deriving metal parts of Configuration as per fiber cables in FOSC for requirement earthing connection 1

2.3 Main accessories and special tools No. Name of accessories Quantity Usage Remarks 1 Heat shrinkable protective Protecting fiber splices Configuration as sleeve per capacity 2 Nylon tie Fixing fiber with protective coat 3 Heat shrinkable fixing sleeve Fixing and sealing single (elliptical) fiber cable 4 Heat shrinkable fixing sleeve Fixing and sealing mass of (circular) fiber cable Configuration as per capacity Configuration as per requirement Configuration as per requirement 5 Branching clip Branching fiber cables Configuration as per requirement 6 Earthing wire 1 piece Putting through between earthing devices 7 Desiccant 1 bag Put into FOSC before sealing for desiccating air. 8 Labeling paper 1 piece Labeling fibers 10 Buffer tube decided by Hitched to fibers and fixed with FOST, managing buffer. customers 11 Aluminum foil paper 1piece To protect the bottom of closure and inlet/outlet tubes when heating heat shrinkable fixing sleeve with fire sprays 3. Necessary tools for installation 3.1 Supplementary materials (to be provided by operator) Name of materials Usage Configuration as per requirement Scotch tape Ethyl alcohol Gauze Labeling, temporarily fixing Cleaning Cleaning 3.2 Special tools (to be provided by operator) Name of tools Usage Fiber cutter Fiber stripper Cutting off fiber cable Strip off protective coat of fiber cable Combo tools Assembling FOSC 3.3 Universal tools(to be provided by operator) Name of tools Usage and specification 2

Band tape Pipe cutter Electrical cutter Combination pliers Screwdriver Measuring fiber cable Cutting fiber cable Take off protective coat of fiber cable Cutting off reinforced core Crossing/Paralleling screwdriver Scissor Waterproof cover Metal wrench Waterproof, dustproof Tightening nut of reinforced core 3.4 Splicing and testing instruments (to be provided by operator) Name of instruments Fusion Splicing Machine OT DR Provisional splicing tools Usage and specification Fiber splicing Splicing testing Provisional testing Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves. 3

4. Installation flow chart 1. Open the closure 2. Determine length of fiber cable to be fixed and stripped inside FOSC 3. Strip off protective coats of fiber cable and fiber 4. Separate fiber cores and prepare work prior to fixing fiber cable 5. Fix reinforced core, and pyrocondense, fix and seal fiber cable 6. Splice fibers 7. Install heat shrinkable protective sleeve and house fibers 8. Check up comprehensively 9. Assemble FOSC housing and fix FOSC 5. The process of installing FOSC. 5.1 Step One - Open the closure 5.1.1 Cleaning the locale and determine where to install the FOSC and then place fiber cables required. 5.1.2 Check whether the main components and accessories have been well prepared inside the package. 4

5.1.3 Open the closure 1 Demount hoop fixing bolt and pull hoop locking system out, then proceed in demounting the hoop. 2 Pull the FOSC cover upwards out, installation could begin. 5.1.4 See Drawing 1 Important issues: If the weather condition is not good enough, then a tent must be pitched for waterproof and dustproof. 5.2 Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC 5.2.1 If all fibers are for branch splicing, please refer to Drawing 2(A) for stripping length. 5.2.2 If some fibers are for straight-through, while others are for branch splicing, please refer to Drawing 2(B) for stripping length. 5.2.3 See Drawing 2. Important issues: 1. Reserve enough length of fiber cable to be spliced. 2. Stripping length also could be decided by customers according to installation requirement 5

100mm sealing and fixing length of fiber cable inside inlet/outlet tube 1750mm length of protective coat of fiber cable to be stripped off 150mm length of fiber with protective coat (the distance from fixing point of fiber cable to fixing point of FOST) Fiber cable 1600mm length of protective coat of fiber to be stripped off ( to be spliced and winded inside the FOST) Temp. locating mark Drawing 2(A) 100mm sealing and fixing length of fiber cable inside inlet/outlet tube 150mm length of fiber with protective coat (the distance from fixing point of fiber cable to fixing point of FOST) Fiber cable 100mm length of fiber with protective coat to be cut 1600mm length of protective coat of fiber to be stripped off ( branch splicing) Temp. locating mark 1850mm length of fiber cable to be stripped off ( for straight-through after being winded) Drawing 2(B) Temp. locating mark 5.3 Step Three Strip off protective coat of fiber cable and fiber 5.3.1 Strip off protective coat of fiber cable from the temp. locating mark with the cutter and the stripper, please refer to Drawing 2 for stripping length. Stripping length also could be decided according to installation requirement 5.3.2 See Drawing 3. Important issues: If it is difficult to pull all the protective coat of fiber cable at one time, strip it off section by section to avoid fiber breakage. Inlet terminal fiber cable Stripping terminal fiber cable Temp. locating mark Cutter Drawing 3 5.4 Step Four Separate fiber cores and prepare work prior to fixing fiber cable. 5.4.1 Wind 2 layers of insulation tape on protective coat of fiber core for protection. Meanwhile, get rid of the stuffing to separate fiber core and clean them. Form a ring with the diameter of 100mm or so and fix it on the fiber temporarily by adhesive tape. 5.4.2 Depending on fiber cable stripped, the following two cases are available. 1 All fibers are to be branched after being spliced completely. 6

2 Some of fibers are for straight-through after being winded, while the others are for branch splicing. 5.4.3 The FOSC is provided with 7 single inlet/outlet tubes, six of which suit for single fiber cables with max. diameter ф21mm and 1 mass inlet/outlet tube which suits for 1 piece of fiber cable with max. diameter ф 36mm or 2 pieces of fiber cables with max. diameter ф 32mm or multi-pieces of fiber cables with short diameter. 5.4.4 Mass inlet/outlet tube is required if some fibers are for straight-through 5.4.5 The corresponding inlet/outlet tube cover could be slightly knocked out with screwdriver from inside to outside according to number and diameter of fiber cable required. 5.4.6 Reserve reinforced core in 70mm length and cut off the unnecessary ones. 5.4.7 See Drawing 4 and Drawing 5. Important Issues:Inlet/outlet tubes are to be selected accurately to make it easy for splicing and sealing. Reinforced core Fiber with protective coat 70mm Fiber cable(1) Fiber cable(2) Reinforced core Fiber cable(3) Fiber with protective coat Drawing 4 Adhesive tape Fiber Adhesive tape Fiber Adhesive tape Fiber Straight-through fiber with protective coat 7

5.5 Fix reinforced core, and pyrocondense, fix and seal fiber cable. 5.5.1 Insert fiber cable into the corresponding heat shrinkable fixing tube, further insert the them into inlet/outlet tube at the bottom of FOSC. 5.5.2 Demount fixing nut of reinforced core with a special wrench (plastic one), which is to be inserted into the fixing slot afterward and tighten it. Then retighten it with a metal wrench (the metal wrench is to be provided by operator). 5.5.3 Hitch heat shrinkable fixing sleeve to the fiber cable till its root by hand. 5.5.4 Please refer to Drawing 5 for installing branching clip. 5.5.5 Heat heat shrinkable fixing sleeve with fire sprayer to make it hugging inlet/outlet tube and fiber cable to reach complete sealing. 5.5.6 See Drawing 5 important issue: 1. Fixing nut of reinforced core should be tightened. 2. While heating, heat shrinkable fixing tube should shrink evenly, and there should be no bubbles, pores and other defects inside the tube. 5.6 Step Six - Splice fibers 5.6.1 Follow user manual of fusion splicing machine to splice fiber. Important issue: pay attention to the twist and bend of fiber 8

5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers. 5.7.1 When having completed splicing the fibers, the first fiber ring should be housed on the farthest side of FOST, the remaining fiber optic should be winded, forming a ring with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve. ( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring properly.) 5.7.2 see Drawing 6 Important issue: pay attention to the twist and bend of fiber. 9

5.8 Step Eight - Check up comprehensively To ensure the technical requirements, the following instructions must be followed: 5.8.1 Fibers with protective coat are fixed with nylon tie at the entrance of FOST. 5.8.2 Grommet should be pressed from inside to outside in order to properly install FOST. 5.8.3 Straight-through fibers with protective coat should be winded to the clasp, as well as reserved fibers. 5.8.4 Check whether the internal tighteners and fixing nut of reinforced core are well tightened. 5.8.5 Check whether seal fitting is installed neatly and smoothly. 5.8.6 Check whether heat shrinkable fixing sleeve is reliable and sealing completely. 5.8.7 See Drawing 7. Important issues: If any problems occur, they should be solved right away. 10

5.9 Step Nine Assemble FOSC housing and fix FOSC 5.9.1 Put FOSC cover on base directly. 5.9.2 Install plastic hoop between FOSC cover and base, aim at the central point of the FOSC, tighten hoop locking system, which is to be fixed by hoop fixing bolt then. 5.9.3 FOSC installation 1 Aerial application: fix metal hoop and transom to the pole. Please refer to Drawing 8 2 Wall mounting application: fix the bracket on the wall with bolt. (metal hoop is not required.) 3 Underground application: metal hoop is not required. 5.9.4 See drawing 8 Important issues: 1. Pay attention while installing plastic hoop. 2. The specification of bolt for fixing the bracket is M8. 11

6. Fiber Optic Splice Closures (FOSC) inspecting and testing items Inspecting item Package Appearance Sign Fiber storage device Electrical jointing device Sealing performance Re-sealing performance Pull Punching Impact Technical Requirements Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. There is a clear sign on the housing, such as name and model of the product, etc. The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa ± 5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. Bearing pull is 800N at axle orientation, there should be no breakage on the housing. Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing Bearing impact energy of 16N m, 3 times of impacts there should be not breakage on the housing Inspecting type Routine test (Before leaving Type test factory) full At least 3 sets sampled each time At least 3 sets sampled each time 12

Bending Torsion Temperature circle Voltage resistance strength Isolating resistance The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±45 0 for 10 circles, there should be no breakage on the housing Bearing torsion 50N m, 10 circle at torsion angle±90 0, There should be no breakage on the housing. Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40 ~+65, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is 5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be 2 10 4 MΩ. At least 3 sets sampled each time At least 3 sets sampled each time 13