ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

Similar documents
PERMANENT PAVEMENT REPAIR NO SCALE

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

SANITARY MANHOLE S-1 ENGINEERING DEPARTMENT PLATE NUMBER NEENAH R-1733 CASTING ASSEMBLY OR AS NOTED ON PLAN OR APPROVED EQUAL.

TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

FOX METRO WATER RECLAMATION DISTRICT MANHOLE / SEWER PIPE MATERIALS AND INSTALLATION SPECIFICATIONS MATERIALS 1. PIPE & FITTINGS

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

SECTION PRECAST CONCRETE MANHOLES

HITT STREET UNIVERSITY PROJECT #: CP REFER TO CP PLANS FOR ELECTRICAL DUCTBANK IN HITT STREET INSTALL:

SECTION D2 MANHOLES AND CATCH BASINS GENERAL MATERIALS

SECTION SANITARY UTILITY SEWERAGE PIPING

SECTION A-A NTS. Figure 4.1 Alternative Flow Dispersal Trench NOTES:

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

40'-0" PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4)


HAMILTON TOWNSHIP MUNICIPAL UTILITIES AUTHORITY

CITY OF FARGO SPECIFICATION SANITARY SEWER

CHAPTER 6 - SANITARY SEWER

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

SECTION PRECAST CONCRETE MANHOLES

SECTION SANITARY SEWER SYSTEM

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1

MAXIMUM TRENCH WIDTH AS REQUIRED SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS

TYPE "A" CATCH BASIN

PART 5 WATER SYSTEMS

Public Water Supply District #2 of St. Charles County, Missouri

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

SECTION MEASUREMENT AND PAYMENT

SECTION SANITARY SEWER SYSTEM

San Antonio Water System Standard Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

SECTION STORM DRAINAGE

Table of Contents. Section Sanitary Sewers Section Includes Description of Work Submittals 1. 1.

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1.

1 Revised: 2019 Edition

San Antonio Water System Specifications for Construction ITEM NO. 853 SANITARY SEWER GLASS-FIBER REINFORCED POLYESTER (FRP) MANHOLES

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe

Table of Contents. Section Sanitary Sewers Section Includes Description of Work Submittals 1. 1.

SECTION FACILITY SANITARY SEWERS

B. Fiberglass for construction in back lot easements placed on cast-in-place base.

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1.

TECHNICAL SPECIFICATION

Table of Contents. Section Structures for Sanitary and Storm Sewers Section Includes Description of Work 1. 1.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

BUILDING SEWER AND GRINDER PUMP CONNECTION & CONSTRUCTION STANDARDS

D. Encase exterior cleanouts in concrete with access cover installed flush with grade.

SECTION 920 SANITARY AND STORM SEWER MANHOLES

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

2.1.2 Minimum wall thickness shall be 90 mm Frames and covers shall be bitumen coated by dipping.

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

D-1 THE CITY OF HARRISBURG 1 1/2" MIN. ID-2 WEARING COARSE EXISTING STREET SURFACE AC-20 SEALER (ALL AROUND) 1 1/2" MIN. ID-2 BINDER COARSE

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY CAST-IN-PLACE. Section CAST-IN-PLACE CONCRETE MANHOLES

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

SPECIAL SPECIFICATION 6664 Level (3) Communications System

SPECIAL SPECIFICATION 6658 Time Warner Communications System

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

SCALE BAR 1:2500 RM OF WOODLANDS OVERALL PLAN - LOW PRESSURE SEWER MAIN. Certificate of Authorization JESSICA MANNESS ENGINEERING, INC. No.

San Antonio Water System Standard Specifications for Construction ITEM NO. 812 WATER MAIN INSTALLATION

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

SECTION 39 - MANHOLES TABLE OF CONTENTS

SPECIAL SPECIFICATION 6666 Charter Communications System

ITEM NO SLIPLINING SANITARY SEWERS

PUBLIC WORKS DEPARTMENT GENERAL NOTES

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

CUYAHOGA COUNTY DEPARTMENT OF PUBLIC WORKS - SANITARY DEPARTMENT DETAIL

Section 4 Service Lines

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS

TABLE OF CONTENTS

SUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018

CITY OF SCHERTZ TEXAS ENGINEERING AND PUBLIC WORKS

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SANITARY SEWER GENERAL NOTES. Sanitary Sewer Construction Notes

CITY OF OCEANSIDE. Electrical Lines, Plumbing and Mechanical Burial & Support Requirements. Informational Bulletin

SECTION PUBLIC WATER SERVICE CONNECTIONS

Project Location: Various, Anywhere, PA Bid Date: 7/16/ Rock Construction Entrance

ITEM 432 TUNNEL CONSTRUCTION

Summary of the 2011 Changes

BEDDING AND TRENCHING TYPE A

Beacon Hill Water & Sewer District Standard Specifications

CITY of DALLAS. Standard Drawings. & Oregon Standard Drawing Amendments. Water Drawings

Copper-Type K soft Drawn 40, 50 HDPE 100 and larger

SECTION FACILITY SANITARY SEWERS

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Section 403. DRAINAGE STRUCTURES

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

Procedures for Connecting to Central Sewer System

Transcription:

VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE ALL AROUND VENT PIPE 4" PVC 4" PVC WYE 4" PVC YARD TRAP LOCATION TO BE FIELD LOCATED 6" PVC WYE REFER TO NOTE #2 4" LATERAL 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR ONE PIPE LENGTH MAX (REFER TO NOTE #1) 4"x6" INCREASER WYE BRANCH SEWER LINE RIGHT-OF-WAY/ PROPERTY LINE REFER TO TYPICAL EXCAVATION, BACKFILL & PIPE EMBEDMENT DETAIL 40'-0" (MAX) RECOMMENDED 1 4" SINGLE RUNNING TRAP WILL BE INSTALLED WITHIN ONE PIPE LENGTH OF THE END OF THE 6" LATERAL 2 MINIMUM DEPTH OF 4" LATERAL WILL BE 48" BELOW FINISHED GRADE UNLESS APPROVED BY TOWNSHIP ENGINEER 3 IF THERE IS NOT A CLEANOUT LOCATED INSIDE OF DWELLING AN ADDITIONAL CLEANOUT SHALL BE INSTALLED IMMEDIATELY OUTSIDE OF THE BUILDING PRIOR TO RUNNING TRAP 4 LOCATE VENT CAP AND CLEANOUT IN LAWN AREA MUSHROOM CAP SHALL BE USED ON VENT 5 IN GENERAL, SANITARY SEWERS SHOULD BE LOCATED AT LEAST 100 FEET FROM PUBLIC WATER SUPPLY SOURCES AND 50 FEET FROM PRIVATE WATER SUPPLY SOURCES, UNLESS THE SANITARY LINES ARE ENCASED IN CONCRETE OR APPROVED EQUIVALENT TYPICAL BUILDING SEWER

SEWER MAIN 1 1/4" FULL PORT BALL CORPORATION STOP 1 1/4" SERVICE LATERAL 1 1/4" FULL PORT BALL CURB STOP W/CURB BOX RIGHT-OF-WAY LINE CHECK VALVE MATERIAL: GLASS FILLED PVC GRINDER PUMP STATION 4" PVC TO DWELLING 4'-0" MIN COVER GRADE MOUNT CONTROL PANEL TO EXTERIOR GRINDER PUMP STATION LID ASSEMBLY WITH PENTAGON HEAD PLUG MATERIAL: CAST IRON WITH ASPHALT-BASE PAINT LABELED "SEWER" 6" MIN AFG 4'-0" TO 5'-0" 220V/1Ø/20 AMP, OR 120V/1Ø/30 AMP POWER FROM HOME TO CONTROL PANEL BY HOME OWNER 1 1/4" CONDUIT 1 1/4" FULL PORT BALL CORPORATION STOP CHECK VALVE 15'-0" MAX BASEMENT MIN 2'-0" OVER ELECTRIC CABLE 1 1/4" SERVICE LATERAL SUBGRADE SADDLE TAP SEWER MAIN 4'-0" MIN COVER SUBGRADE 1 1/4" FULL PORT BALL CURB STOP 4" MIN COMPACTED 2A AGGREGATE CONCRETE 4" PVC TESTED WATER TIGHT 4" MIN COMPACTED 2A AGGREGATE

FINAL BACKFILL PROPOSED PIPE EXIST SOIL MIN MIN INITIAL BACKFILL HAUNCHING AASHTO M43 GRADUATION NO 7 OR NO 8 MATERIAL SHALL MEET THE REQUIREMENTS OF PUBLICATION 408, SECTION 703 6" BEDDING TYPICAL EXCAVATION, BACKFILL & PIPE EMBEDMENT DETAIL

GRADE 4'-0" MINIMUM EXIST WATER MAIN UNDISTURBED EARTH IF LESS THAN 10'-0" MAINTAIN 18" MIN NEW SEWER LINE NEW SEWER LINE PARALLEL TO EXISTING WATER MAIN DETAIL

UNDISTURBED EARTH SEWER LINE MIN BARREL OF PIPE BELL OF PIPE "A" 8" OD 8" TRENCH WIDTH PIPE SIZE 4" - 16" 18" - 48" 54" - 84" "A" 6" 6" 10" NOTE: ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AT THE END OF 28 DAYS CONCRETE ENCASEMENT DETAIL

GRADE 10'-0" EQUAL DISTANCE EQUAL DISTANCE MIN 18" MIN 4'-0" MECHANICAL JOINTS REQUIRED NEW SEWER LINE REFER TO DETAIL S-6 EXISTING WATER MAIN WHEN VERTICAL SEPARATION IS LESS THAN 18" PROVIDE CONCRETE ENCASEMENT ON UNDISTURBED GROUND THE LENGTH OF THE ENCASEMENT SHALL BE EXTENDED A MINIMUM OF 10 FEET BEYOND THE CENTERLINE OF THE WATER MAIN IN BOTH DIRECTIONS NOTE: ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT THE END OF 28 DAYS NEW SEWER LINE CROSSING UNDER EXISTING WATER MAIN DETAIL

GRADE EQUAL 10'-0" EQUAL WHEN VERTICAL SEPARATION IS LESS THAN 18" PROVIDE CONCRETE ENCASEMENT ON UNDISTURBED GROUND THE LENGTH OF THE ENCASEMENT SHALL BE EXTENDED A MINIMUM OF 10 FEET BEYOND THE CENTERLINE OF THE WATER MAIN IN BOTH DIRECTIONS DISTANCE DISTANCE 4'-0" MINIMUM REFER TO DETAIL S-6 MIN 18" MECHANICAL JOINTS REQUIRED NEW SEWER LINE EXIST WATER MAIN POLYETHYLENE ENCASEMENT NOTE: ALL CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT THE END OF 28 DAYS NEW SEWER LINE CROSSING OVER EXISTING WATER MAIN DETAIL

REFER TO FRAME AND COVER DETAIL PRECAST CONCRETE GRADE RINGS (VARIES, MIN 6", MAX ) 24"x48" ADAPTOR 8" O-RING JOINT PREFORMED PLASTIC SEALING COMPOUND: FS SS-S-210A, TYPE 1, ROPE FORM HEAT SHRINKABLE SHEET MANHOLE EXTERIOR TO BE COATED WITH BITUMASTIC SEALANT VARIES 48" RISERS 5" 48" INSIDE POLYPROPYLENE MANHOLE STEPS @ OC WITH CAST IN PRECAST BASE 6" CHANNEL MAX 6" MIN COMPACTED PennDOT 2A MODIFIED ON UNDISTURBED SUBGRADE 9" 1 ALL PIPE TO MANHOLE CONNECTIONS SHALL BE MADE WITH A CAST-IN-PLACE GASKET (A-LOK OR APPROVED EQUAL) 2 MANHOLES EXCEEDING A DEPTH OF 16 FEET SHALL PROVIDE PRE-CAST LANDING PLATFORM TYPICAL MANHOLE DETAIL

FRAME LETTERS TO BE 2" HIGH MIN 4-1"Ø CORED OR DRILLED HOLES ON 32" BOLT CIRCLE AS SHOWN LIFTING RING (TYP 2 PLACES) 3/8" 3/8" 1/2" 5/8" 3 1/8" 3/16" PICK HOLE (TYP 2 PLACES) PICK HOLE DETAIL "O-RING" GASKET PLAN 1 3/4" 1 3/8" 3 1/8" 24" 23 3/4" (TOP) 23 5/8" (BOTTOM) 3/4" 3/4" 1/8" NON-SKID LUGS 3 1/8" 7" -9" 1" 3" 5/8" 7/8" 5" 24 1/2" 3/4" SECTION LIFT RING DETAILS NOTE: APPROXIMATE WEIGHT 500# CAST IRON REGULAR MANHOLE FRAME & COVER

SEMI-CIRCULAR CHANNELS AND FLOOR TO BE SMOOTH DIA 48" PRECAST CONCRETE MANHOLE SECTIONS MANHOLE BASE TYPICAL CHANNEL CONFIGURATION 1 ALL FLOW CHANNELS SHALL BE PRE-CAST BY MANUFACTURER UNLESS AUTHORIZED BY AUTHORITY

INFLUENT 45 CUT PVC PIPE TO PROVIDE SPLASH GUARD VARIES PVC PIPE DIA EQUALS INFLUENT PIPE DIA PLUS 2" STAINLESS STEEL BANDS 48" OC CHANNEL TYPICAL INSIDE DROP MANHOLE DETAIL