Low-cost Construction for High-energy Savings. Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity

Similar documents
Feature Zone IECC 2009 IECC

Priority Air Sealing Locations for New Homes

Air Sealing for 5 ACH 50

Chapter 14 - Air Sealing

Table Air Barrier and Insulation Inspection Component Criteria

Overview of Presentation. Airflow Control: Why. Airflow Control: what kind?

SOUTHWEST ENERGY CODES CONFERENCE. This is how we do it! Getting to 3ACH50 and

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Hardin County Planning and Development Commission

Presented by: Stephen Carr Regional Building Science Manager (386)

WeatherSmart Air Barrier Installation Guide

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

Using Insulation and Weatherization to Improve Sales of New and Existing Homes.

Boulder City NV Prepared by (Print Name) Signature Date

Residential Energy Code Update

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

Insulation Technologies and Installation Specifications for Better Energy Performance of Commercial Buildings

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Thermal Bridging in Residential Construction

Presented by: Stephen Carr Regional Building Science Manager (386)

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

SIP Homes: Built for a Lifetime of Comfort and Value

Air Sealing, Infiltration & Ventilation

Challenging Framing Details

Initial House Assessments & Sealing Efforts: California Builder #1

Michigan Energy Code Training and Implementation Program

Explaining the Thermal Bypass Checklist. Ed Minch, Energy Services Group Kelly Parker, GWS

Designing and Testing for Airtight Construction:

Our sophisticated knowledge base and innovative product line promote quality green building methods, energy efficiency, comfort and health.

Welcome to this continuing education seminar. This is the first of three parts of the Building Enclosure Fundamentals series.

FIELD COPY ATTACHMENT

Air Infiltration & Insulation

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

8/14/2015. Course Description. Course Objectives AIR, WATER, AND MOISTURE MANAGEMENT IN LIGHT COMMERCIAL BUILDING ENVELOPES

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

REScheck Software Version Compliance Certificate

Standards for Jackson EMC s Right Choice Program Revised: June 2011

IECC - RESIDENTIAL - ENERGY TAC

Where to Draw the Line with Thermal Boundaries

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Initial House Assessments & Sealing Options:

Healthy, Durable, Low Energy Buildings: Thermal: High R. Thermal bridges. Fundamentals, techniques, and pitfalls

Building Science Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, Straube buildingscience.com 1 of 24

Performance Requirements and Options in the International Energy Conservation Code. Mike Turns, Senior Program Manager

Lock In Energy Savings For Life

2012 IECC Residential with State Adopted Changes

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges

Water control Vapor control and drying Room for growth

Thermal Bypass Checklist: How We Got There?

HPW Protocol Reference Manual

SUSTAINABLE ENERGY ANALYTICS

ENERGY STAR Qualified Homes

High Performance Walls:

High Performance Walls:

Building Enclosure Detailing for Walls and Low-Sloped Roofs

Innovating Continuous Exterior Insulation. Theresa A. Weston, PhD. 1

ENERGY STAR Homes version 3 Designing and Building to Meet the 2011 Changes. Thursday, February 24, 2011

9.36 Energy Efficiency

buildingscience.com buildingscience.com buildingscience.com buildingscience.com buildingscience.com Key Partners/Products buildingscience.

FirstEnergy Program Overview

A.ENVELOPE AIR SEALING

Residential Codes FAQs: 2015 International Energy Conservation Code (IECC) with MA Amendments & MA Stretch Energy Code

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

Residential Construction

Basements are Changing. Basements Part of the Enclosure. Basements. Control: Moisture. Moisture: Old ideas. Energy Efficient, Durable, Healthy

ENERGY STAR Qualified Homes

Residential Energy Code Combustion Air and Make-Up Air

Charter Township of Washington

2. Heat Transfer is quantified in British Thermal Units (BTU s)

New Approaches to Energy Efficiency & Green Building. Who is Icynene Inc.? World-Wide Distribution. The Icynene Insulation System

2010 National Building Code Adoption and Associated Process Changes

High Performance, Low Energy

INSULATION BATT (1) (2) Code Reference: 2016 Title 24, Reference Appendices RA3.5. Pressure or Friction Fit

10 Steps to Save Energy in Your House

ENERGY STAR Qualified Homes, Version 3 (Rev. 03) Inspection Checklists For National Program Requirements

ENERGY SAVINGS FOR LIFE

The Lower The HERS Score The Better. Tight Building Envelope. Renewable Energy Sources. Materials & Waste Management. Energy Efficient Lighting

Goals of Session. Building a Better Thermal Envelope. Thermal Envelope Priorities. Disclaimer. Insulation performance (Real World)

How to Meet Code and Manage Moisture in an Environment of Increasing Air Tightness Requirements. Ted Winslow

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

Residential Requirements of the Texas Energy Code 2009 IRC Chap 11

9.36. Energy Efficiency

Overview. Historic Preservation Meets Building Science: The Mallett Deep Energy Retrofit. R-Value Targets. The Mallett Deep Energy Retrofit

Controlling Moisture.

Boundaries and Barriers

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

Meeting the Challenges of Emerging Air-Tightness Requirements

Managing Condensation and Thermal Performance with Continuous Insulation

High Performance Walls:

The REMOTE Wall System

2014 British Columbia Building Code Changes

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

Transcription:

Low-cost Construction for High-energy Savings Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity construction@rahh.org

Objectives: 1. Control air & moisture in high-performance, low-cost construction 2. Basics at design stage of house 3. Material options (insulation, windows, mechanicals, etc.) for high-performing homes 4. Improve basics & modified techniques before hightech solutions 5. ENERGY STAR for Homes process & checklists 6. Performance measures in diagnostic testing 7. Assess energy use in completed homes

What does it take to build an energy-efficient home? 1) Labor u Standard methods, OVE, new best practices u Devil in the details 2) Materials u Energy-efficient u Durable u Wet/dry? u Over time u Maintaining Durability

Materials Fiberglass OSB Durability Moisture Time Wood Polystyrene Concrete Sheetrock

The climate throws a lot at us Are we building ships? It may make for natural beauty but in our homes it conspires to undo our work!

Control air & moisture in highperformance, low-cost construction u u u Top cause of heat and moisture movement is air flow Preventing heat and moisture flow through the foundation system Preventing heat and air flow through the building envelope u Follow up after sheetrock installation, attic and walls u u u u Sealing doors and window openings Air-tight framing methods Framing to foundation transition Air-sealing the attic

Control in the wall assembly Outside Inside Heat Summer Moisture Control Wall Assembly Control Heat Winter Moisture

#1 Means of heat & moisture transfer in wall assemblies is: Air Flow

Stop the air flow! And stop the heat loss & the moisture damage Control Air Flow Control

From constructioninstruction.com u The reality: Many walls have too little insulation and too many leaks. This means that warm moist air can get in, find a cool surface, and condense. Result: The wall gets wet, mold and mildew begin to grow. u Moisture can be carried by the flow of air into or out of the home through holes and cracks in the building envelope. This airflow is caused by a variety of forces including stack effect, the wind, and mechanical systems. u By building a tight envelope and controlling mechanical pressures, we can reduce moisture flow through a building.

Preventing heat, moisture & air flow through the building envelope u Start with air-tight framing u Testing at insulation stage (we found biggest leaks due to framing) u WRB barrier, taped top, bottom, edges u Stopping wind pressure from producing air infiltration u Interior barrier methods u Poly/air-tight drywall, smart vapor retarders (vapor retarders whose vapor permeability changes based on the humidity conditions) u Connecting the interior and exterior barriers u Sealed to framing for complete air block u Under slab control of moisture & radon u Poly film, polystyrene board

Start with air-tight framing Caulking the framing Caulking the framing

Rim joist areas These areas need sealing

Sealing the gaps Penetrations such as electrical boxes Bottom plate Foundation to wood connections

WRB barrier, taped top, bottom, edges, window & door openings

Follow up after sheetrock installation, attic & walls, etc.

Preventing heat & moisture flow through the foundation system u u u u u u u Build foundation like a boat hull underwater Capillary break between footing & foundation wall (radon control) Connecting the capillary break to under slab radon control Insulating under the slab (new energy code) Use of ICF Capping the foundation top with waterproof membrane Connection between foundation and framing

Under Slab Poly & Foam Board Poly from under ICF wall Sealing around plumbing

Connection between foundation wall & framing

Framing

Framing & Framing to Foundation

Connection between foundation wall & framing WRB sealed behind foundation protection

Basics at design stage of house u Planning for minimal ductwork u Keeping ducts inside the thermal envelope u Pass-through instead of ducted returns when possible to minimize ducts u Simplified design of home u OVE framing u Line up floor trusses, wall studs, roof trusses (24: o.c.) u Reduce thermal transfer

Central Returns w/pass throughs

Pass-throughs, returns

Material options (insulation, windows, mechanicals, etc.) for high-performing homes u u u u Polystyrene board Fiberglas batts New energy code/no interior vapor barrier required? Foam fill around windows u Inexpensive caulk & air-tight framing u WRB, tape and sealing the entire envelope u All sealed ducting u Triple-glazed window costs

Polystyrene + Fiberglass

Improve basics & modified techniques before high-tech solutions u Details, details, details. The Devil is in there! u Focus on the details to achieve maximum performance of materials through best practices u OVE framing practices u Two-stud corners, ladder pocket, alignment of components u Pre-poly and poly connection to WRB u Complexity and cost of generating power lower use first. u PV is a rapidly changing industry and current equipment will continue to drop in cost and go up in efficiency (a changing variable)

Ducts/plumbing in unconditioned space

ENERGY STAR for Homes process & checklists u Checklists: u Thermal Enclosure System Rater Checklist u HVAC System Quality Installation Contractor Checklist u HVAC System Quality Installation Rater Checklist u Water Management System Builder Checklist u Hiring a qualified HVAC contractor u NO un-ducted cavity returns u Seal ALL seams u Seal cabinet u Seal boots to subfloor/wall/ceiling u Credentialed through ACCA OR Advanced Energy

Checklists u Thermal Enclosure u HVAC Contractor u HVAC Rater u Water Management

Performance measures in diagnostic testing u Energy rater three stages of evaluation u Site Visit 1 (SV1) Completion of framing u SV2 after HVAC, Plumbing, Electrical & insulation & poly VB u Blower door and duct leakage testing numbers SV3 u Duct leakage testing at SV2

Site Visit

Site Visit

Site Visit

Duct Leakage Test Missed it! Main Level SF - 940.4 Lower Level SF - 940.4 Total SF = 1,880.8 1,880.8 SF / 100 = 18.808 18.808 x 8 CFM25 = 150.464 Your allowable total duct leakage is 150.464. Your test results were 151...this does not meet the requirements.

HVAC System u NO un-ducted cavity returns u Seal ALL seams u Seal cabinet u Seal boots to subfloor/wall/ceiling u Credentialed through ACCA OR Advanced Energy

Performance Measures & Testing u Blower door: 4 ACH50 u Air changers/hour @ induced pressure of -50 Pascals u Meant to simulate a stiff wind perhaps 15-20 mph u Ducts total: 8 CFM / 100 SF finished u Total of all ductwork u Ducts outside: 4 CFM / 100 SF finished u Total leakage in ductwork in unconditioned space u Just Right & Airtight, Joe Lstiburek BuildingScience.com

OVE Framing Practices

Advanced Framing: An Examination of its Practical Use in Residential Construction Based on the case study, some OVE techniques were practical to implement (when visibly marked on the construction plans) and had noticeable material savings, thermal benefits, and positively affected the quality of framing. Other practices were found to be problematic, either from a technical or logistical standpoint, or had minimal energy or lumber saving benefits (considering that exterior foam sheathing was employed on the home). On a first-time home, these added soft costs associated with the implementation of even the most basic OVE practices are likely to offset any savings accrued from reduced lumber use. Furthermore, the energy efficiency gains associated with using continuous exterior insulating sheathing overshadow the efficiency gains from employing OVE framing techniques.

Reducing backing requirements

Assess energy use in completed homes u u u Energy rater Blower door test and understanding the results Duct leakage test and understanding the results and why it s important

ACH50 = 1.72 ACH50 = 3.03

Fuel Summary for Kasson House

Utility use in RAHH Homes

Utility use in RAHH Homes

Utility Use Assessments $250.00 $200.00 $150.00 $149.49 Average'Monthly'Total'Natural'Gas'Cost,'2013:2014'!$151!!!$90!! $188.51!$106!! $201.53!$131!! $180.09 $156.36!$100!! $137.73 $100.00!$47!!!$53!! $101.08!$40!! $108.53 $77.98 $81.30 $79.83!$35!! $74.09!$31!!!$28!!!$27!! $50.00 $0.00 November! December! January! February! March! April! May! June! July! August! September! October!

Utility Use Assessments Average Monthly Winter Heat Cost - Rochester $123 $130 $96 $76 $40 November December January February March

Utility Use Assessments Average'Monthly'Total'Natural'Gas'Use,'2013:2014' (MBtus)' 16" 14" 12" 10" 8" 6" 4" 2" 0" November" December" January" February" March" April" May" June" July" August" September" October"

Is Energy Star 3 Worth the Cost?

Special thanks to Molly Berg, Sustainable Building Program Manager at Habitat for Humanity of Minnesota Contributions: Cost analysis, assistance with Energy Rating, filling out the forms, etc. Molly Berg

In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized by the Minnesota Department of Labor and Industry as satisfying 1.5 hours of credit toward Building Officials and Residential Contractors continuing education requirements. For additional continuing education approvals, please see your credit tracking card.

Links: OVE: http://www.toolbase.org/building-systems/whole-house-systems/advance-framingtechniques Building Science: http://www.buildingscience.com/index_html Construction Instruction: http://www.constructioninstruction.com/

Time-permitting: Exterior foam board/ new energy code.

Incorporating Thick Layers of Exterior Rigid Insulation on Walls Wall assemblies are one portion of the building that provide a separation between the inside environment and the outside environment. This separation is often referred to as a building enclosure or a building envelope. For wall assemblies, control of rainwater, airflow, water vapor flow, and heat flow are key factors to providing a durable enclosure. The control of these elements can be separated into four principle control layers. They are presented in order of importance: u A water control layer u An air control layer u A vapor control layer u A thermal control layer The best place for the control layers is to locate them on the outside of the structure in order to protect the structure.

Incorporating Thick Layers of Exterior Rigid Insulation on Walls u u u There are three principle control approaches to dealing with water in the vapor form. The first is to let the water vapor pass through the assembly from the inside out and from the outside in. This type of wall assembly is called a flow-through assembly and can dry to both sides. The second is to locate a distinctive vapor control layer to retard the flow of water vapor into the wall assembly from either the inside or from the outside. This type of assembly is called vapor control layer assembly. The most common location for a vapor control layer is on the inside warm in winter side of the thermal insulation. The third is to control the temperature of the surfaces where condensation is likely to occur by raising the surface temperature with insulation. The most common method of achieving this is to use rigid insulation on the exterior of assemblies. This type of assembly is called control of condensing surface temperature assembly. When rigid insulation is added to the exterior of the structural sheathing, the interior surface temperature of the structural sheathing is increased since the insulation keeps the sheathing warmer. By raising the temperature of the condensing surface of interest sufficiently, condensation from interior water vapor migrating into the wall assembly does not occur. This allows assemblies to be constructed in cold climates without interior vapor control layers. The building codes recognize this and provide guidance on the minimum thermal resistance values of rigid insulation required to control condensation, when Class I and II vapor retarders are replaced with Class III retarders in specific regions.

Table 5 is information taken from Table R601.3.1 Class III Vapor Retarders of the 2009 IRC and Table R702.7.1 Class III Vapor Retarders of the 2012 IRC and provides guidance for thermal resistance values to control condensation for Climate Zones 5, 6, 7, 8 and Marine 4. Table 5. Thermal resistance values to control condensation for climate zones 5, 6, 7, 8 and marine 4 from (2009 IRC and 2012 IRC).

Checklists

Checklists