Irrigation accessories

Similar documents
Irrigation accessories

endoscope care and accessories featuring our infection control products

biopsy valves & irrigation accessories

A TAILORED SOLUTION... for endoscopic irrigation and insufflation tubing

DEFENDO. Sterile Single-use Valves. Procedure

biopsy valves & irrigation accessories

ENDORA Endoscope Tracking System

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes Webinar FAQ

Improper Scope Reprocessing is Dangerous and has caused Patient Infections. 1-6

Recommended Procedure for Sampling Gastrointestinal Flexible Endoscopes

Monitoring the disinfection of flexible endoscopes using ATP bioluminescence

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

Contains Nonbinding Recommendations

ENDOSCOPE REPROCESSING AND INFECTION CONTROL FOR ENDOSCOPY

The Future of Endoscopy. STARTS NOW Sterile Sing le-use Endoscopy

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

TOTAL SOLUTION FOR ENDOSCOPE REPROCESSING

ENDOSCOPY PRACTICE Manual cleaning and Disinfection of flexible endoscopes

Report prepared on behalf of Medivators Inc. by Nova Biologicals, Inc., Title of Report: Laboratory Evaluation of Endoscope Waterbottles

MDRAO Importance of Bedside & Manual Precleaning CONMED.CA

Hygiene Management Guide for Flexible Endoscopes

Update on Duodenoscope Related CRE Transmission. Disclosures. Outline 9/2/2016. None

Transmissi (ERCP) visit. by multiple. sites. it. perform the to this safety. time to help. provided by a. Interim. b. Interim. Method: c.

The Evolution of Liquid Chemical Sterilization. For High-Speed Device Turnaround

Slide 1. Slide 2. Slide 3

SUBJECT: Detection of residual organic soils inside various channels of lumened items.

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

ADVANTAGE PLUS Pass-Thru

Dissecting Outbreaks of Multi-resistant Bacteria in Gastrointestinal Endoscopy

The Decontamination, Storage and Use of Flexible and Rigid Endoscopes

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only.

Safety, Efficacy & Microbiological Consideration

Is contamination of bronchoscopes really a problem?

Understanding ANSI/AAMI ST 91. Flexible and Semi-Rigid Endoscope Reprocessing in Healthcare Facilities

The Research and Application of Disposable Sheath for Preventing Digestive Endoscope Cross-infection

QUALITY ASSURANCE IN ENDOSCOPY

AUTOMATED ENDOSCOPE REPROCESSOR. OER-Pro Easy. Fast. Reliable.

Christina Bradley Endoscope Decontamination A Webber Training Teleclass. Christina Bradley

Endoscopy and OR Solutions SYSTEM 1 TM. Express STERILE PROCESSING SYSTEM SAFETY, ASSURANCE AND EFFICIENCY. One Integrated Approach to Healthcare

Safety, Efficacy & Microbiological Consideration

St Boniface Research Centre Winnipeg, Manitoba Canada

Modular. Mobile. Flexible.

ENDOSCOPE DECONTAMINATION- EDUCATION AND TRAINING COMPETENCY FRAMEWORK

ISO INTERNATIONAL STANDARD. Optics and photonics Medical endoscopes and endotherapy devices Part 1: General requirements

Ethicon, Inc All rights reserved. EVOTECH and the EVOTECH logo are registered trademarks owned by Advanced Sterilization Products.

SUBJECT: Detection of Blood (hemoglobin) residue inside the biopsy channel of an endoendoscope

BIOTECH-GERMANDE ENDOSCOPE REPROCESSING WITH BRUSHLESS CLEANING PROCESS CONDITIONS. Lionel PINEAU PhD

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

OLYMPUS Investor Day 2018 Enhancement of Infection Prevention Activities

DEC TM Video Duodenoscope ED34-i10T2. Lock in. Elevate your care.

CT contrast media injector from ulrich medical. 24 h

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

Best Practices for Reprocessing Endoscopes

The Human Touches in Endoscope Infection

Duodenoscope Surveillance Sampling and Culturing Protocols

ANSI/AAMI ST91: 2015

The purpose of this DOPs form is to provide a universal training and assessment tool for continuity when training in manual cleaning processes.

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

Hoe steriel moet het zijn? Prof Dr Margreet C.Vos MD PhD

For: Infection Control, Operating Room, Endoscopy, Instrument Reprocessing, Risk Managers, et al. Volume 14, Numbers 11, 12 November-December 2008

Flexible endoscopy in a robotic world Challenges? HONG KONG HOSPITAL AUTHORITY - ADVANCED COURSE FOR INFECTION CONTROL NOVEMBER 2017

NEW Faster, more versatile!

5 Updates to Flexible Endoscope Reprocessing

Endoscope Decontamination. A Tube in a Hole??

Endoscopy What s New Up There? Frank Myers, MA, CIC, FAPIC

SUBJECT: Detection of Blood residue inside the biopsy channel of a scope

Winter/spring 2017/18. CEO Lars Marcher

SERVICE & MAINTENANCE. Cantel. At your service.

NEW Faster, more versatile!

House Keeping. Introduction to ANSI/AAMI ST91:2015: Flexible and Semi-Rigid Endoscope Processing in Health Care Facilities. Welcome!

CISA Reprocessing Systems

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

In use test of a Washer-disinfector reprocessing of flexible endoscopes

Accessories for Acute Care

Appendix 2. Revised 510(k) Summary

Administrative Policies and Procedures. Cross Reference: Date Issued: 2/14 Date Reviewed: 9/14 Date: Revised: 12/14 Attachment: None Page of 1 of 6

Instructions for Use: Duodenoscope Sampling Kit

Prevention of Transmission of the Superbug Carbapenem-Resistant Enterobacteriaceae (CRE) during Gastrointestinal Endoscopy

CATALOGUE. Single Use and Autoclavable Cleaning Brushes for Medical Use

Biotech. MicroSan mf DNA Fmarker ENDOSCOPE REPROCESSING VERIFICATION SYSTEM ITALIAN INVESTMENT SHOWCASE TURIN /// APRIL 2018

Endoscope Reprocessor Specification Installation Instructions

High-Level Disinfectant and Sterilant. Rapicide SAFETY, EFFICACY AND MICROBIOLOGICAL CONSIDERATIONS

Guidelines for Selection and Use of Disinfectants

USER S MANUAL. Flexible Nasopharyngo-Laryngoscope

Dental Water Quality

A Report on the Widespread Inadequate Reprocessing of Endoscope Air/Water and Suction Valves by Healthcare Facilities

Objectives. The Perioperative Nurse s Role 6/24/2016. Instrument Processing & Sterilization Chesapeake Perioperative Consortium 2016

Safety, Efficacy, and Microbiological Considerations. * For use with RAPICIDE PA outside of the USA, Canada and Australia

Monitoring Flexible Endoscope Channels to Assure Cleaning

Instructions for Use: NOW! Swab Test

EVIS EXERA III. Advancing the Art of Bronchoscopy.

Endoscope Microbial Surveillance Testing Made Easy

Description. Used materials. Warnings and precautions

CDWA3 / CDWA4 CDWAH. Page 4. BASKET ZONE: water pressure, spray system performance, detergent chemistry and concentration, temperature.

ChemoClave System Oncology Kits and Multi-Packs

Safe Medication. Disposable Syringes

Transcription:

Irrigation accessories

irrigation The risk of contamination Infection control is a top concern in GI units. The American Society of Gastrointestinal Endoscopy (ASGE) states that crosscontamination and infection may occur by contaminated equipment. 1 Possible contaminants that may linger in reusable accessories include viruses fungal spores bacteria Other industry leaders share these concerns. Their statements are referenced on page 6 of this brochure. 1 American Society for Gastrointestinal Endoscopy. Infection control during gastrointestinal endoscopy. Volume 67, No. 6, 08

solutions Disposable solutions... To address cross-contamination concerns and support patient safety, US Endoscopy has developed two lines of disposable irrigation accessories the AquaShield water bottle system and the Torrent irrigation system. Both systems... Offer an alternative option to manual reprocessing Help to reduce the risk of cross-contamination between patients Provide a 24-hour use option - use one for the day then throw it away Include a 24-hour red sticker, which helps facilitate compliance with Joint Commission requirements www.usendoscopy.com

patient AquaShield water bottle system From water bottle systems to irrigation tubin protect your patients from cross-contaminat The AquaShield water bottle system is a system including a water bottle cap, tubing and connector, and 24-hour red sticker available with or without a CO 2 connector available with a CO 2 connector in two irrigation line lengths (10cm and 152cm) a disposable solution for Olympus, Pentax and Fujinon endoscope users Allows clinicians to use either CO 2 or room air insufflation during procedures Includes hydrophilic filter to protect insufflator from fluid invasion (CO 2 systems only)

safety Torrent irrigation system g, US Endoscopy offers a solution to proactively ion. Torrent irrigation system offers a single-use scope connector with a one-way luer-lock valve features 24-hour use irrigation tubing is compatible with Olympus, ERBE, and MEDIVATORS electric irrigation pumps irrigation system Help minimize the risk of crosscontamination with a US Endoscopy single-use connector which includes a one-way luer-lock valve Torrent scope connector for PENTAX scopes Torrent scope connector for Olympus scopes www.usendoscopy.com

Additional References - Industry Statements American Society of Gastrointestinal Endoscopy (ASGE) Episodes of transmission of infection to patients can be traced, in most cases, to procedural errors in cleaning and disinfection of the endoscope or its accessories. Bacteria or viruses have been transmitted by: contaminated water bottles and irrigating solutions 2 Association of Professionals in Infection Control and Epidemiology (APIC) The water bottle and connecting tubes are difficult to clean and disinfect and are often colonized with Pseudomonas species and may serve as important reservoirs of cross-infection. 3 Society of Gastrointestinal Nursing & Associates (SGNA) Prior to storage, there should be no residual fluid or moisture remaining Thoroughly dry all water bottle surfaces to reduce the potential for bacterial colonization. 4 2 American Society for Gastrointestinal Endoscopy, Transmission of infection by gastrointestinal endoscopy. Volume 54, No. 6:01. www.asge.org 3 Association of Professionals in Infection Control and Epidemiology (APIC), APIC Guideline for Infection Prevention and Control in Flexible Endoscopy (00). www.apic.org 4 Society of Gastroenterology Nurses and Associates (SGNA), Reprocessing of Water bottles Used During Endoscopy. www.sgna.org

product information part number description units/box AquaShield water bottle system BX00711540 water bottle cap system, Olympus 140/160/180/190 series endoscopes 25 BX00711541 water bottle cap system - CO 2 (4 line), Olympus 140/160/180/190 series endoscopes 25 BX00711549 water bottle cap system - CO 2 (60 line), Olympus 140/160/180/190 series endoscopes 25 BX00711550 water bottle cap system, Pentax endoscopes 25 BX00711551 water bottle cap system - CO 2 (60 line), Pentax endoscopes 25 BX00711553 water bottle cap system - CO 2 (60 line), Fujinon endoscopes 25 Torrent irrigation system BX00711560 Irrigation tubing (305cm) - Olympus pumps 25 BX00711561 Irrigation tubing (305cm) - ERBE, Medivators, Olympus pumps 25 BX00711570 scope connector - Olympus 140/160/180/190 series only 100 BX00711571 scope connector - PENTAX 70/80/90 series only 100 irrigation kits BX00711544 BX00711545 BX00711554 BX00711555 BX00711556 BX00711557 BX00711558 BX00711559 Torrent & AquaShield system kit (Olympus) BX00711540 - AquaShield system - 25 each BX00711560 - Torrent system (Olympus pumps) - 25 each BX00711570 - single-use scope connector - 100 each Torrent & AquaShield system kit (ERBE/MEDIVATORS) BX00711540 - AquaShield system - 25 each BX00711561 - Torrent system (ERBE/MEDIVATORS/Olympus pumps) - 25 each BX00711570 - single-use scope connector - 100 each Irrigation Kit - standard BX00711540 - AquaShield system - 1 each BX00711561 - Torrent system (ERBE/MEDIVATORS/Olympus pumps) - 1 each Irrigation Kit - CO2 short BX00711541 - AquaShield system - CO 2 (4 connection tube) - 1 each BX00711561 - Torrent system (ERBE/MEDIVATORS/Olympus pumps) - 1 each Irrigation Kit - CO2 long BX00711549 - AquaShield system - CO 2 (60 connection tube) - 1 each BX00711561 - Torrent system (ERBE/MEDIVATORS/Olympus pumps) - 1 each Irrigation Kit standard, Olympus pumps only BX00711540 AquaShield System - 1 each BX00711560 Torrent System - 1 each Irrigation Kit CO2 short, Olympus pumps only BX00711541 - AquaShield System - CO2 (4 connection tube) - 1 each BX00711560 - Torrent System - 1 each Irrigation Kit CO2 long, Olympus pumps only BX00711549 - AquaShield System - CO2 (60 connection tube) - 1 each BX00711560 - Torrent System - 1 each AquaShield systems and Torrent systems are compatible with Baxter/Hospira/B.Braun bottles. www.usendoscopy.com - -

B. Braun refers to B. Braun Medical Inc. Baxter refers to Baxter International, Inc. MEDIVATORS, Inc. is a registered trademark of Cantel Medical ERBE USA Incorporated is a subsidiary of ERBE GmbM. Hospira refers to Hospira, Inc. Olympus is a registered trademark of Olympus Optical, Inc. PENTAX is a registered trademark of Asahi Kogaku Kogyo Kabushiki Kaisha US Endoscopy is a subsidiary of STERIS Corporation. Listening and delivering solutions, the US Endoscopy listening and delivering solutions design, and all marks denoted with or are registered with the U.S. Patent and Trademark Office, or trademarks owned by US Endoscopy. 17 US Endoscopy. All Rights Reserved. 5976 Heisley Road Mentor, OH 44060 phone (1) 440 / 639-4494 fax (1) 440 / 639-4495 customer service (1) 800 / 769-8226 Follow us: www.usendoscopy.com 760923 Rev. E