Electrical Metallic Tubing (EMT) Fittings

Similar documents
Electrical Metallic Tubing (EMT) Fittings

Specifications Electrical Metallic Tubing (EMT)

Service Entrance Cable Fittings

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Liquidtight Flexible Metal Conduit Fittings For Control and Power Cable Applications. * U.L. and CSA not applicable.

Youngstown State University

Design Standard Conduit for Electrical Systems

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Student Services & Classroom Addition

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

Mogul Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

SECTION RACEWAYS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY

AMFICO AMERICAN FITTINGS. Use ONE Fitting on ALL Conduits. It s EMT, It s Rigid, It s IMC, It s UL Approved, It s Steel, It s American.

GLENWOOD PLACE 2 MAR 2015

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

Red Dot. Rigid Fittings. Table of Contents

SECTION RACEWAYS AND BOXES FOR ELECTRONIC SAFETY AND SECURITY

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

SECTION RACEWAYS AND BOXES

SECTION CONDUI T

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

Thomas & Betts LT & CORD FITTINGS

SECTION CONDUITS AND BOXES

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

1. Hangers and supports for electrical equipment and systems.

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

Raceway and Boxes for Electrical Systems Page 1 of 7

Fig. 1 - Standard Clevis Hanger

DIVISION 26 - ELECTRICAL Section Conduit for Electrical Systems 1. GENERAL 1.1 WORK INCLUDES

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

A. Coordinate arrangement, mounting, and support of electrical equipment:

SECTION CONDUIT AND FITTINGS

SECTION ELECTRICAL SYSTEM RACEWAY and BOXES

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used.

ADDENDUM 2. Lockwood Hall Renovation Project. July 9, The bidders are to take notice and acknowledge the following:

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION OUTLET, PULL, AND JUNCTION BOXES

IMC REFERENCE GUIDE. A decision maker s guide to applicable codes, standards and technical data.

SECTION RACEWAYS AND BOXES

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS. A. ANSI C Electrical Rigid Steel Conduit, Zinc Coated.

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.

maximum mechanical protection


IRON CONDUIT BODIES 5-5/16 (135) 6-9/16 (167) 7-9/16 (192) 8-7/16 (214) 10-3/8 (264) 12-3/8 (314) 15-5/8 (397) 15-5/8 (397)

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CONDUIT, FITTINGS, AND BODIES

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Kaf-Tech Product Specification

UNDERGROUND SERVICES SECONDARY

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

T&B Fittings. Industrial Fittings. Liquidtight Flexible Metal Conduit Fittings. Specifications

VITALink 2-Hour Fire Resistive Circuit Integrity Cable with Hose Stream

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR PLUMBING

TUFF-SEAL RSSS SERIES STAINLESS STEEL CORD GRIPS. Toll Free Fax

ST. VINCENT COLLEGE SIS AND HERMAN DUPRÉ SCIENCE PAVILLION SECTION LABORATORY ELECTRICAL REQUIREMENTS PART 1 - GENERAL REQUIREMENTS

Fig Beam Clamp Retaining Strap (B-Line B3367)

Gas Station & C Store SECTION CWM Job No

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Wholesale.

A. American Society for Testing and Materials (ASTM): Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.

SECTION CONDUITS AND BACKBOXES FOR ELECTRONIC SAFETY AND SECURITY

A. Bellcore CAO-8546 Specification for Type B, C, and D Plastic Conduit. B. NEMA TC 6& PVC Plastic Utilities Duct for Underground Installation.

Overview Better by Design

BASIC ELECTRICAL MATERIALS AND METHODS

Overview Steel City. Metallic Boxes and Covers. Advantages of Steel City. Boxes and Covers. Boxes & Covers Steel City Metallic Boxes

Procurement Services SVC East Fowler Avenue Tampa, Florida (813)

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

CONDUITS AND FITTINGS

Material/Finish Aluminum Copper-free aluminum (less than 4/10 of 1%) Electrostatically applied powder coating

TUFF-SEAL RSR SERIES ALUMINUM CORD GRIPS. Toll Free Fax RSR Series Straight Aluminum Cord Grips G 1

CUSH-A-THERM VAPOR BARRIER PROTECTION

SECTION RACEWAYS AND CONDUIT

Transcription:

Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe Spacers Ferrous Electrical Metallic Tubing (EMT) shall be of the hot dipped galvanized type conforming to applicable specifications WW-6/ANSI C.98/ANSI C80./UL 797/ CSA C22.2 No. 8. E.M.T. protected solely by enamel shall not be used Where lengths of EMT are coupled together or connected to boxes or enclosures or where EMT is coupled to threaded rigid metal conduit or IMC, fittings approved for intended applications shall be used, and: () Shall be of rugged steel/malleable iron construction electro zinc plated inside/outside including threads. Connector throat shall be bushed with a nylon insulator (2) Shall be of raintight type for installations exposed to weather or wet locations such as Thomas & Betts series TC2A-RT and TK2A-RT () Shall be of concrete tight type for installations in poured concrete such as Thomas & Betts series TC2, TC72, or TK2, 2, 20, and 0 Raintight type fittings may be substituted for concrete tight application. Where electrical metallic tubing and associated fittings are used as part of equipment grounding system: () A bonding type locknut such as Thomas & Betts series 06 shall be installed where hub type fitting terminates into a threadless opening (2) Compression ring type fittings such as Thomas & Betts series 2 and 20 shall be used for terminating and coupling EMT shall be securely fastened in place at intervals as specified by the code using straps, hangers and other supporting assemblies as indicated on plans, and as manufactured by Thomas & Betts, series 476 straps. In wet locations or where supporting surfaces are of absorbent materials vertical and horizontal runs of conduit shall be firmly supported such that there is at least " air space between conduit and supporting surface Spacers and supporting straps shall be of rugged malleable iron or steel construction hot dipped galvanized and conforming to requirements of Canadian Standards Association Standard C22.2 No. 8 as manufactured by Thomas & Betts, series 476 straps and series 0 spacers Series 476 Pipe Straps Series 06 Bonding Locknut Series HT-22 Combination Coupling (Concrete tight) Rigid/IMC to EMT (Set Screw Type) Zinc Die Cast Series TK2-E EMT Coupling (Concrete tight) (Set Screw Type) A-00 Tel: 90.22.8000 800.86.7809 Fax: 90.22.4

Fittings for Electrical Metallic Tubing (EMT) Compression Type, Raintight 2 Series 20 Series Application To connect and effectively bond electrical metallic tubing to a box or an enclosure To provide a rain tight connection between tubing and the connector To couple ends of tubing Features Rugged all steel construction Rings designed to positively bond conduit to fitting; unique locknut design provides effective bond between fitting and box or enclosure; ground continuity is ensured Nylon insulator firmly secured in place protects conductors, reduces wire pulling effort and prevents thread damage in handling Locknuts are designed with extended reach to lock fitting on to a thin box or an enclosure Locknuts tighten without deformation; will not vibrate loose Standard Material All Steel except Insulator. Insulator....................Thermoplastic, UL Rated 0 C Standard Finish All Steel Parts...............Electro Zinc Plated & Chromate Coated Insulator.........................As Molded Range Conduit Size " thru 2" Hub Size " thru 2" NPS Hubs provided with straight pipe threads NPS. Listings/Compliances UL (UL File No. E-692) CSA (LR-4484, LR-8994) UL 4B CSA C22.2 No. 8 NFPA 70 NEMA FB Federal Specification A-A-0 Federal Standard H-28 (Threads) Tel: 90.22.8000 800.86.7809 Fax: 90.22.4 A-0

EMT Raintight Fittings Patented design includes a sealing ring, ensuring a 60 raintight seal Distinctive fitting design and gland nut color enable inspectors to visually inspect conformance from a distance no close-up inspection required All-steel construction for rugged, durable installations Sharp teeth on locknuts ensure a solid bond and tight grip on surface of enclosure Does not require disassembly to install Materials, Specifications Material: Steel Body, Steel Locknut Plating: Zinc Plated, Clear Chromate coating Liner: Nylon (for insulated fittings) Threads: Male hub threads NPS NEMA applications require sealing gaskets (sold separately) Use: Raintight, wet locations, concrete-tight Raintight EMT Compression Fittings feature a distinctive design and vibrant gland nut color, enabling inspectors to visually inspect conformance from a distance. There's no close-up inspection required! Listings/Compliances UL Listed: E-692 Listed Raintight UL Standard: 4B NEMA: FB- B Peaks L Max L Max A H Peaks B Max NON-INS. INS. PKG. CAT. NO. H L QTY. Compression Connectors TCA-RT TC7A-RT ".0.097.02.42 0 TC2A-RT TC72A-RT ".0.0.29.42 0 TCA-RT TC7A-RT ".67.64.80.62 2 TC4A-RT TC74A-RT ".70 2.27 2.000 2.062 2 TCA-RT TC7A-RT ".82 2.97 2.7 2.87 2 TC6A-RT TC76A-RT 2.82 2.87 2.70 2.2 2 CAT. NO. SIZE B L PKG. QTY. Compression Couplings TKA-RT ".660.097 0 TK2A-RT ".660.0 0 TKA-RT ".94.64 2 TK4A-RT " 2.74 2.27 2 TKA-RT " 2.00 2.97 2 TK6A-RT 2 2.70 2.87 2 Sealing Gaskets* (sold separately) SR-0 " 0 SR-02 " 0 SR-0 " 0 * Gaskets sold separately. In some jurisdictions, sealing gaskets are not required when installed in a threaded opening. Also, a connector assembled in the bottom of a box or enclosure may be considered by code to be located (placed) so that water will not enter the enclosure at the knockout interface (NEC 4. (A)). In this instance, the sealing O-ring may not be required. Consult with the local authority having jurisdiction. EMT Connectors Nylon Insulated EMT Couplings EMT Connectors DIMENSION (IN.) 2 " 64 2 22 " 2 64 27 2 " 7 42 " 2 2 2 " 2 2 2 62 2" 2 2 2 UL File No. E-692 CSA File No. LR2798 DIMENSION (IN.) 20 " 27 220 " 2 20 " 2 420 " 2 2 29 20 " 2 620 2" 2 7 UL File No. E-692 CSA File No. LR2798 DIMENSION (IN.) 2-TB " 9 22 " 2 2 " 42 " 2 2-TB " 2 2 9 62 2" 2 2 T&B EMT (thinwall) fittings comply with Federal Spec. WF408B. UL File No. E-692 CSA File No. LR2798 A-02 Tel: 90.22.8000 800.86.7809 Fax: 90.22.4

Insulated for safe, simple installation in cramped locations or tight corners! Short Elbows Insulated* Ideal for applications where large radius conduit elbows won t fit or would appear unworkmanlike Shoulders on body of " size are hex-shaped to provide positive holding for standard installation tools Malleable iron construction UL rated 0 C Ideal for cramped locations or tight corners! Short Elbows Malleable Iron* DIMENSION (IN.) C 4240 " 7 s 7 424-TB " 9 4242 " 7 27 424-TB " 2 2 4244 " 2 424 2" UL File No. E-0904 Shoulders on body of " size are hex-shaped to provide positive holding for standard installation tools Malleable iron construction DIMENSION (IN.) C 420 " 7 s 7 42 " 9 422 " 7 27 42 " 2 2 424 " 2 42 2" UL File No. E-0904 For connecting EMT to threaded rigid and intermediate metal conduit. Combination Coupling Steel* 0-TB " " 2 " 9 2 UL File No. E-0904 For XJG Conduit Expansion Couplings for EMT see page A-2. Tel: 90.22.8000 800.86.7809 Fax: 90.22.4 A-0

Snap-on design holds strap in place! Pipe Straps Steel Oval Hole for Screw Size (C) C (BOLT HOLE) 49 " 27 460 " 2 46 " 2 462 " 2 7 Elongated bolt hole makes alignment easy, even when holes in mounting surface are out of alignment Available in " to 2" sizes 46 " 464 2" 4 Not UL Listed. and 4484 Designed to fit each size of conduit snugly! Pipe Straps Malleable Iron Oval Hole for Screw Size (C) C (BOLT HOLE) 476 " 2 477 " 2 9 2 478 " 479 " 480 " 4 High reinforcing ribs on each side increase strength and reduce weight Hot-dipped galvanized finish 48 2" 282 2 " 28 " 6 284 " 7 9 28 4" 8 7 Not UL Listed. and 4484 7 Eliminates the need for costly offset-bending of conduit to prevent corrosive moisture traps when conduit is mounted directly to a surface! Pipe Spacers 0 Used with T&B conduit straps to permit space between conduit and mounting surface Pre-mountable and stackable to eliminate offsetting Malleable iron construction with hot-dipped galvanized finish 0 ", ", " " 7 "- "-2" " " 2 2 "-" 9 9 " " "-4" 7 9 " 2" 4 4 "-"-6" 0 9 " 2 9 " Conforms to NEC 00--C. A-04 Tel: 90.22.8000 800.86.7809 Fax: 90.22.4