Construction. Flexible PVC waterstops. Product Description. Product Data. Tests. Form. Storage. Technical Data

Similar documents
CHARACTERISTICS / ADVANTAGES

PVC profile waterstops for joint sealing

According German Standard DIN part 1. Standard range of PVC-P based flexible waterstops for movement (expansion) and construction joint sealing

PVC profile waterstops for joint sealing

Injectable hose for sealing construction joints in watertight structures

t e c h n i c a l d a t a s h e e t t e c h n i c a l d a t a s h e e t t e c h n i c a l d a t a s h e e t

Injectable hose with integral valves for sealing construction joints in watertight structures

Construction. High performance joint sealing system. Product Description. System Data Sheet Edition _1. 1 Sikadur Combiflex SG system 1/8

dura. joint PVC waterstops

Water resistant bonding agent and mortar additive

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

Spray applied polyurea membrane

Sealing profiles which swell in contact with water.

Sealing profiles which swell in contact with water.

MasterSeal 940. Centrally and externally placed PVC Waterstops

MasterPren PVC Waterstops

Construction. Universal anchoring adhesive. Product Description. Tests. Product Data Sheet Edition _1. 1 Sika AnchorFix S 1/6

Ultra fast spray applied polyurethane membrane

Sika KAB combination joint waterbars waterstopping systems

SUPERSWELL 47B HYDROPHILIC BUTYL WATERSTOP SEAL

Construction. Universal anchoring adhesive. Product Description 1 1/7. Product Data Sheet Edition _1 Sika AnchorFix -S

Swellable joint sealing profiles

Construction. Injectable hose for sealing construction joints in watertight structures. Product Description. Product Data. Tests.

Construction. Injectable Hose for Sealing Construction Joints in Watertight Structures. Product Description. Tests. Product Data

PRODUCT DATA SHEET. SikaFuko VT PRODUCT- DESCRIPTION

PRODUCT DATA SHEET. SikaFuko Eco-1 PRODUCT- DESCRIPTION. Re-injectable hose for sealing construction joints in watertight structures

Sika Hydrotite CJ K

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits

PRODUCT DATA SHEET SikaProof A

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

Construction. 1-part high performance sealant for flooring. Product Description. Environmental Information. Product Data Sheet Edition _1

Injectable Hose With Integral Valves for Sealing Construction Joints in Watertight Structures

Construction. SikaProof A. Fully bonded FPO sheet waterproofing membrane system for basement and other below ground structures. Product Description

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description.

Construction. Hydrophilic, swellable hose for sealing construction joints in watertight structures. (formerly Sika Injectoflex HPM)

Ultra Fast Curing Polyurethane Waterproofing Membrane System

Construction. Injectable hose with integral valves for sealing construction joints in watertight structures. Product Description. Product Data.

Product Data Sheet SikaFuko Swell-1 Positioning Description Uses Advantages Approval / Standards Construction Product Data Packaging

PRODUCT DATA SHEET SikaProof Bentonite

Construction. Mineral dry shake floor hardener. Product Description. Product Data. Tests. Form. Storage

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

Construction. 2-part epoxy roller and seal coat. Product Description. Product Data. Form. Storage. Product Data Sheet Edition _1

R4 Hand Placed / Wet Spray Repair Microconcrete

Sika Tricomer Compression Seals

Part of the Sikaplan WT Membrane System

Construction. 2-part epoxy impregnation resin. Product Description. Product Data 1 1/6. Tests. Form. Storage

R4 Fast Setting Cementitious Repair Mortar

TECHNICAL DATA SHEET SIKA RAPID REPAIR MORTAR 25KG

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

TECHNICAL DATA SHEET SIKADUR 31 CF NORMAL 6KG

Cementitious Concrete Repair Mortar

WATERPROOF X 1 INJECTION HOSE SYSTEM

Construction. Coloured mineral dry shake floor hardener. Product Description. Product Data. Tests. Form. Storage

R4 Hand Placed / Wet Spray Repair Microconcrete

Product Data Sheet Product Description Uses Characteristics / Advantages Tests Approval / Standards Product Data Construction Form

Non-sag, ultra low modulus, neutral cure silicone sealant for pavements

Part of the Sikaplan WT Membrane System

1-part polyurethane pourable self levelling floor joint sealant

3-Part Epoxy Grouting System for Pile Capping

PRODUCT DATA SHEET. SikaProof A

Construction. One component cementitious mortar fibre reinforced for flexible waterproofing. Product Description. Product Data. Form.

Construction. R4 Low Resistivity Dry Sprayed Repair Concrete. Product Description. Product Data. Tests. Form. Storage

TECHNICAL DATA SHEET SIKAFLEX FLOOR

CHARACTERISTICS / ADVANTAGES

1-part high performance sealant for flooring

Sika Waterbars - Tricomer Clamped Type

Injectable hose with integral valves for sealing construction joints in watertight structures

Product Data Sheet Sikadur -31 CF Normal Product Description Uses ruction Const Characteristics / Advantages

Construction. Coloured mineral dry shake floor hardener. Product Description. Product Data. Tests. Form. Storage

Construction. Integral waterproofing compound for concrete and mortar. Product Description. Product Data. Form. Storage.

Construction. 1-part floor joint sealant. Product Description. Product Data. Tests. Form. Storage

Sika Elastomer Compression Seals

METHOD STATEMENT Sika Drain-850 Geo

2-part epoxy self-smoothing and broadcast system. Sikafloor -263 SLHC is a two part, economic, multi purpose binder based on epoxy resin.

Construction. 2-part epoxy protective coating. Product Description. Product Data 1 1/5. Test. Form. Storage

Carbon fibre shear links for structural strengthening

Sikadur -330 is a two part, thixotropic epoxy based impregnating resin / adhesive.

Non-metallic dry shake floor hardener

Construction. 1-part elastic sealant for the internal and external caulking of wooden floors. Product Description. Product Data. Form.

TECHNICAL DATA SHEET SIKADUR 31 RAPID 1.2KG

Liquid applied polyurea hybrid membrane

Roofing. Sika-Trocal SG 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Construction. 2-pack Polyurethane grout for rail fixing. Productdescription. Product Data. Technical Data

Sikafloor -264 HC is a two part, economic, solvent-free coloured epoxy resin.

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

EN R4 High Strength High Build Concrete Repair Mortar

Construction. Corrosion inhibiting impregnation (improved formulation) Product Description. Product Data Sheet Edition _1

2-part epoxy impregnation resin

1-part elastic joint sealant and multipurpose adhesive

Construction. Sikafloor -2 SynTop-2. Non-rusting hard aggregates dry shake floor hardener. Product Description. Product Data. Uses

Construction. Carbon fiber shear links for structural strengthening. System Description. (Template for local translation, only for internal use)

TECHNICAL DATA SHEET SIKAFLEX PRO-3 SELF LEVELLING

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Construction. High performance joint sealing system. Product Description 1 1/9. Product Data Sheet Edition 29th October 2015

Footfall sound dampening system for wood flooring

Conforms to the requirements of ETAG Certificate: European Technical Approval No. ETA-05/0265

CONCRETE REPAIR SITE HANDBOOK Hand Placed and Spray Applications

Construction. Adhesive for bonding Carbon Fibre & Steel reinforcement. Product Description. Tests

2-part, electrostatic conductive epoxy coating

Transcription:

Construction Product Data Sheet Edition 2016-07_1 Flexible PVC waterstops Product Description Uses Characteristics / Advantages Flexible PVC waterstops used to seal construction and expansion joints in concrete structures. are available in different sizes and types, depending on their use. are used to seal construction and expansion joints: In water retaining structures such as reservoirs, water towers, dams, spillways, canals, swimming pools, sewage tanks, etc. To keep water out of concrete structures such as basements, underground car parks, tunnels, subways, retaining walls, etc. High quality PVC for long durability Suitable for high water pressure Easy to weld on site Many different sizes and types available, depending on their use Tests Approval / Standards conform to the requirements of BS 2571. Product Data Form Colour Packaging Yellow 20 m rolls Storage Storage Conditions / Shelf Life 5 years from the date of production if stored properly in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +10 C and +25 C. Protect from direct sunlight. Technical Data Type Polyvinyl Chloride Specific Gravity 1.4 max. (BS 2782: 620) Temperatures Service -35 to +55 C Welding ~ + 180 C 1/5

Expansion Construction Expansion Construction Mechanical / Physical Properties Tensile Strength 12 N/mm 2 min. (BS 2782: 320A) Shore A Hardness 75 ± 5 (BS 2782: 365B) Elongation at Break 300% min. (BS 2782: 320A) Water Absorption 120 mg max. (at +23 C) (BS 2782: 430A) Thermal Stability 70 minimum (Congo Red Test at +180 C) (BS 2782: 130A) Resistance Chemical Resistance Permanent Water, seawater and sewage Temporary Diluted inorganic alkalis, mineral acids and mineral oils Sika -Waterbar Uses Types Width, mm (± 5 mm) Roll Length, m Centrally Placed Waterbars: Installation in the center of concrete structures Normal Thickness, mm (± 10%) V-15M 150 20 3.0 5.0 V-20M 200 20 3.0 5.0 V-25M 250 20 3.0 5.0 V-32M 320 15 3.0 5.0 O-15M 150 20 3.0 4.5 O-20M 200 20 3.0 4.5 O-25M 250 20 3.0 4.5 O-32M 320 15 3.0 4.5 Surface Waterbars: Installation on the surface of concrete structures AR-25M 250 20 4.0 DR-20M 200 20 3.0 DR-25M 250 20 4.0 Joint Finishing Types: Installed by pushing onto the formwork board or onto joint lining FA 3-10 3/10 10 ~ 5 FA 3-14 3/14 10 ~ 5 Special Corner and End Places A wide range of standardised prefabricated junction pieces are also available allowing easy site welding of butt joints to junction pieces. Customised pieces can be made available. In such cases, drawings must be provided giving exact dimensions and jointing details. L-Piece, Flat T-Piece, Flat Cross-Piece, Flat L-Piece, Vertical T-Piece, Vertical Cross-Piece, Vertical Sika recommends the use of its specialised welding equipment for on-site welding which consists of thermostatically-controlled welding blades and special welding jigs (each type of Waterbar requires its own welding jig to suit the particular shape). 2/5

System Information Application Details Placing of Waterbars Placing the Concrete Concreting the Second Stage Placing is executed in accordance with the engineer s drawings on which the waterbar profile and the position required are marked. Level differences, bends, junctions, etc. should be carefully considered before placing. The use of factory produced junction pieces are encouraged so that on-site welding is reduced to only simple butt joints, thereby minimising joint failure. are placed continuously, thereby maintaining an integral sealing network. provide an effective and thorough means of waterproofing. However, care must be taken to ensure that concrete is well placed and compacted around the waterbar area. The perform only if both sides are well embedded in the concrete. The accumulation of coarse aggregates (honeycombs) should be avoided around the waterbars. Only dense, well compacted concrete can ensure proper sealing between the concrete and. Placing of fresh concrete near the requires care or it may be forced from its position by pressure of the fresh concrete. To prevent this, the same concrete pressure must be present on both sides of the waterbar during placing. The consistency of the concrete itself should be neither too plastic nor too stiff and the aggregate must be well graded. Vibration should be executed with care. The concrete around the waterbar should be thoroughly checked for honeycombing on the stopends and repaired if necessary. The waterbar must be cleaned of all hardened concrete remnants adhering from the first concrete stage. The same precautions highlighted above should also be observed during second stage concreting. Application Instructions Waterbar Selection The selection of a suitable waterbar is governed by the type of joint, location of waterbar, concrete thickness, grade or concrete, reinforcement position, expected movement (expansion/shear) as well as waterhead/pressure to which it is to be exposed to. However, a simple rule-of-thumb for selection is as follows: Up to 250 mm thick slab/wall: Waterbar width should be equal to or approximating to the slab/wall thickness, example for slabs 200 mm thick, select 200 mm waterbar size. Above 250 mm thick slab/wall: Note: Select largest waterbar size. Depending on the requirements by the engineer, 2 layers of waterbars may be required for high water pressure and/or deep section. 3/5

Application Methods / Tools Centrally Placed Waterbars Fixing To Reinforcement pre-punched eyelets are located in the outer flanges of the profiles. These simplify the fixing of waterbars to the steel reinforcement with tie wires to ensure the waterbars are not displaced during concreting. Fixing To Formwork a 2-part (split) formwork may be used (preferred). In this method, allow half of the waterbar to jut out while the other half is cast-in. This waterbar is clamped between the formwork. See Typical Detailing of, Figure 1 and 2. Externally Placed Waterbars Fixing To Slab - place the waterbar flat on the lean concrete or base of the structure. The formwork for the stopends will terminate in the middle of the waterbar, allowing half of the waterbar to be cast while the other half is exposed to receive the next casting. See Typical Detailing of, Figure 3. Note: When working with expansion joints where there is a central bulb, it is important that the bulb should not be cast into the first pour of the concrete but remains exposed (free). Welding are made from thermoplastic PVC and therefore allow an easy onsite welding. However, it is recommended to use factory fabricated junctions such as T, L, X and Corner pieces. The ends are heated with a welding blade until the PVC melts (without burning or charring). The welding blade is removed and the molten ends are immediately pressed together. The welded joint should be inspected once it has cooled. Sources of welding errors: Irregularity of cut edges Insufficient or excessive heating of blade Dirt accumulation on blade including charred remains of PVC. Clean PVC from blade while it is still hot. Stripping Cleaning of Tools Removal of the formwork around waterbars must be done with care. Clean all tools and application equipment with water immediately after use. Hardened and/or cured material can only be mechanically removed. Typical Detailing of Split Formwork With O Split Formwork With V Surface Waterbars Using AR Figure 1 Figure 2 Figure 3 The O Profile may also be used in conjunction with split formwork. However care should be taken to ensure that the O ring is not squashed flat between the two forms. This method of installation increases the capacity of the to accommodate expansion. The V Profile is fitted into the split formwork or shuttering for casting centrally into the stopends. It is used for construction joints and movement joints where nominal movement is anticipated, such as basement or retaining walls. Surface are for installing into the face of the concrete structures. They are used for construction joints with slight to medium water pressure and are fixed on the water side of the concrete wall or floor by attaching it temporarily to the formwork during concrete placement. The protruding ribs become cast into the concrete to provide an excellent watertight seal while at the same time securely anchoring the to the structure. 4/5

Construction Value Base All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Health and Safety Information For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet (available upon request) containing physical, ecological, toxicological and other safety-related data. Legal Note The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Sika Singapore Pte Ltd 66A, Sungei Kadut Street 1, #04-00 Singapore 729368 SINGAPORE Phone: +65 6777 2811 Fax: +65 6779 6200 e-mail: info@sg.sika.com www.sika.com.sg Sika Kimia Sdn Bhd Lot 689 Nilai Industrial Estate 71800 Nilai, Negeri Sembilan DK MALAYSIA Phone: +606-7991762 Fax: +606-7991980 e-mail: info@my.sika.com www.sika.com.my 5/5