NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 NOTE: SECURE COVER PLATE USING TWO FASTENERS WITH NEOPRENE GASKETS AT THE CENTER OF EACH FASCIA SECTION Light-Metal Roof Edge, Raised 5-1
NAILS 3 O.C. STAGGERED 2 ROWS METAL SET IN SPECIFIED MASTIC PRIME FLANGE BEFORE SPECIFIED MASTIC 1/2 MIN. 10 0 MAX. JOINT COVER 4 6 WIDE SET IN SPECIFIED MASTIC AND SECURED USING TWO FASTENERS THROUGH THE GAP IN THE FASCIA FLANGE TWO-PLY FELT ENVELOPE CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 Light-Metal Roof Edge 5-2
NOT TO SCALE PLIES EITHER OVER OR UNDER WOOD CANT AS SPECIFIED ELASTOMERIC SHEET FLASHING AS SPECIFIED. APPLY ADHESIVE FULL WIDTH. WOOD CANT STRIP NAILED TO BLOCKING SPECIFIED APPROX. 1 CANT. MIN. 1 MINIMUM 1,y APPROX. 1 NOT TO SCALE TremLine Fascia Metal Roof Edge 5-3
TWO-PLY MECHANICALLY FASTEN, STAGGER 3 O.C. METAL FLANGE SET IN SPECIFIED MASTIC PRIME FLANGE BEFORE. GRAVEL GUARD REQUIRED FOR GRAVEL SURFACED ROOFS GRAVEL ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATE SHEET I-49 FELT ENVELOPE GUTTER BRACKET 36 O.C. DRY SHEET GUTTER SPACER 36 O.C. STAGGERED ALTERNATELY (18 ) WITH BRACKETS SLOPE GUTTER TO DOWNSPOUTS 1/4 IN./FT. MINIMUM Roof Edge with Gutter 5-4
SPECIFIED SEALANT COUNTERFLASHING INSTALLED INTO REGLET AND SECURED WITH LEAD WEDGES 8 O.C. FASTENERS 6 O.C. NAILED VENTED BASE SHEET NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED TWO-PLY BASE FLASHING SPECIFIED, NAILED VENTED BASE SHEET LIGHTWEIGHT INSULATING CONCRETE NOTE: MECHANICALLY ATTACH VENTED BASE SHEET OVER FOIL LAMINATED BARRIER SHEET Base Flashing for Vented Base Sheet 5-5
STRUCTURAL SECTION COUNTERFLASHING FASTENED AS NECESSARY WELD PLATE WATERTIGHT 8 MIN. FASTENERS 8 O.C. INSULATE TO PREVENT CONDENSATION TWO-PLY NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. I-Beam Flashing 5-6
LEAD CAP 1 DOWN INTO PIPE 2 MIN. ROLLED LEAD FLASHING 1 DOWN INTO PIPE SET LEAD FLANGE IN SPECIFIED MASTIC FOR PLUMBING VENTS WITH PERIMETERS LESS THAN 2 : USE LEAD CAPS OPTIONAL: SOLDER STAINLESS STEEL SCREEN PLUMBING VENT STACK MASTIC SEAL AT PERIMETER 4 MIN. TWO-PLY NOTE: 1. SHEET LEAD: MINIMUM 4 LB. PER SQ. FT. 2. SHEET COPPER: MINIMUM 16 OZ. IF COPPER FLASHING IS INSTALLED OVER AN IRON OR STEEL PIPE, WRAP AN ASPHALT COATED FELT TO PREVENT DIRECT CONTACT BETWEEN TWO DISSIMILAR METALS. Plumbing Vent Flashing 5-7
METAL SIDING METAL DRIP FLASHING FASTENED 8 O.C. TERMINATION BAR FASTENED 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED 4 MIN. SPECIFIED GRAVEL Metal Wall Flashing 5-8
SPECIFIED SEALANT ONE PIECE COUNTERFLASHING INSTALLED INTO REGLET AND SECURED WITH LEAD WEDGES, 8 O.C. FLEXIBLE VAPOR RETARDER TO SERVE AS RETAINER FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING, 2 ROWS STAGGERED EACH ROW 12 O.C. SPECIFIED COMPRESSIBLE TO DECK WITH APPROPRIATE FASTENERS, 2 ROWS STAGGERED Wall Flashing for Non-Wall Supported Deck 5-9
SPECIFIED SEALANT FASTENERS 24 O.C. MINIMUM TWO PIECE COUNTERFLASHING INSTALLED INTO RECEIVER; 3 OVERLAP AT JOINTS OPTIONAL: 2 WIDE CLIP OPTIONAL: SEAL TOP OF FLASHING WITH 3 COURSES OF ASPHALT MASTIC AND REINFORCING MESH FASTENERS 6 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED SPECIFIED TWO-PLY BASE FLASHING Wall Flashing Wall Supported Deck 5-10
COMPRESSIBLE BUTYL GASKET TAPE TO SPAN IRREGULARITIES TERMINATION BAR FASTENED 8 O.C. SPECIFIED SEALANT SURFACE MOUNTED COUNTERFLASHING FASTENED 8 O.C. MINIMUM ELASTOMERIC FLASHING SPECIFIED NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED Wall Flashing for Concrete Walls and Parapets 5-11
SHEET METAL COVER AS SPECIFIED FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. 2-PLY Wood Curb 5-12
16 GA. MIN. FRAME SEALANT TAPE AS SPECIFIED WOOD NAILER 2 O.C. COUNTERFLASHING FASTENED 18 O.C. 8 MIN. FASTENER 8 O.C. TWO-PLY BASE FLASHING ADHERED TWO-PLY ALTERNATE FRAME LOCATION FOR HEAVY UNITS NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. Curb for Air Handling Unit 5-13
SHEET METAL HOOD CROSS BREAK OR SLOPE FOR DRAINAGE SEAL METAL SCREW INSULATE INSIDE OF METAL WORK IN COLD CLIMATES CLOSURE DETAIL SHEET METAL COLLAR FASTENERS 8 O.C. SLOPE PIPES DOWN AND AWAY FROM HOOD TWO-PLY FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME METAL FLANGE BEFORE. Piping through Roof Deck 5-14
STRAINER / DOME CLAMPING RING 4# LEAD FLASHING ELASTOMERIC TAPER TO DRAIN TURN 4# LEAD DOWN INTO DRAIN 1 DECK CLAMP Roof Drain 5-15
GRAVEL STOP SPECIFIED SEALANT SOLDER OR SEAL SECTION A A B A A B SECTION B B TWO-PLY NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED SEAL TOP OF FLANGE METAL SLEEVE THROUGH SCUPPER GRAVEL STOP Scupper 5-16
METAL PITCH PAN WITH METAL HOOD SPECIFIED DRAWBAND AND SEALANT FILL TO TOP OF PAN WITH SPECIFIED MASTIC MASTIC SEAL AT PERIMETER TWO-PLY FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE Pitch Pocket 5-17
SPECIFIED DRAWBAND AND SEALANT METAL PITCH PAN WITH METAL HOOD FILL 1 FROM TOP WITH NON-SHRINK GROUT, TOP OFF WITH SPECIFIED MASTIC MASTIC SEAL AT PERIMETER ELASTOMERIC,, SYSTEM FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE Pitch Pocket with Grout 5-18
STORM COLLAR CAULK DRAW BAND WITH SPECIFIED ELASTOMERIC SEALANT SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE TWO-PLY PROJECTION Metal Sleeve and Storm Collar 5-19
STRUCTURAL FRAME PIPE COLUMN STRUCTURAL FRAME UMBRELLA ATTACHED WITH DRAWBAND CAULK WITH SPECIFIED ELASTOMERIC SEALANT MASTIC SEAL AT PERIMETER TWO-PLY 4 MINIMUM WELDED ANCHOR PLATE SINGLE LAYER COMPRESSIBLE NAIL FLANGE TO WOOD NAILER, FLANGE SET IN MASTIC OVER, PRIME FLANGE BEFORE Equipment Stand (Pipe) 5-20
SET BOLT IN ELASTOMERIC SEALANT. CAULK PERIMETER OF LEG & FASTENER. NEOPRENE PAD LEG 14 MIN. FASTENERS 24 O.C. ONE-PIECE COUNTERFLASHING 8 MIN. FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. Equipment or Sign Support 5-21
SECTION A A A 10 0 MAX. A BASE SHEET LINER OVER NAILER SEAL SLOPE INWARD NEOPRENE GASKETED FASTENERS 24 O.C. BASE FLASHING AS SPECIFIED NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. SPECIFIED 4 MIN. CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 Light-Metal Parapet Cap 5-22
FLEXIBLE IMPERVIOUS MEMBRANE ADHERED TO VAPOR RETARDER FLEXIBLE VAPOR RETARDER TO SERVE AS RETAINER FASTENERS 8 O.C. BOTH SIDES CHAMFER EACH SIDE OF WOOD CURB TO DRAIN FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS SEAL 8 MIN. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. REINFORCED ELASTOMERIC FLASHING MEMBRANE INORGANIC COMPRESSIBLE SPECIFIED SLOPE Expansion Joint 5-23
SEAL EDGE WITH REINFORCING MESH AND ASPHALT MASTIC EXTEND NEW 12 ONTO PREPARED AREA EXISTING NEW REMOVE EMBEDDED GRAVEL / DEBRIS MINIMUM 18 12 AND 18 PLY SHEETS ADHERED IN SPECIFIED ADHESIVE EXISTING DECK * BEFORE NEXT DAY S WORK, REMOVE TEMPORARY TIE-IN AND FILLERS Daily Waterstop / Tie-In 5-24
SEAL EDGE WITH REINFORCING MESH AND ASPHALT MASTIC EXTEND NEW 12 ONTO PREPARED AREA EXISTING NEW REMOVE EMBEDDED GRAVEL / DEBRIS 18 12 AND 18 PLY SHEETS ADHERED IN SPECIFIED MASTIC EXISTING DECK Permanent Tie-In 5-25
A A A COPING CAP FLASHING AND FASCIA VARIATIONS EXPOSED FACE WITHOUT BRAKES A DIMENSIONS GALVANIZED IRON COLD ROLLED COPPER ALUMINUM 3003-H14 UP TO 6 FACE 24 GA. 16 OZ..040 (18 GA.) 6 TO 8 FACE 24 GA. 16 OZ..050 (16 GA.) 8 TO 10 FACE 22 GA. 20 OZ..064 (14 GA.) 10 TO 15 FACE 20 GA. ADD BRAKES TO STIFFEN.080 (12 GA.) Gauge or Thickness Guide (Minimum) 5-26