Light-Metal Roof Edge, Raised

Similar documents
DATE R2.2 ROOF DETAILS - BUILT UP ROOF DETAILS CURBS. An Company PHONE:

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science

WICOMICO COUNTY BOARD OF EDUCATION

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

2 + 3 A-2.0 A A-2.1 A-2.0 A A '-8" A-2.0 A-2.0 A-2.0 SIM. A-2.0 A-2.0 A-2.0 SIM. A-2.0 SIM.

SECTION ROOF SPECIALTIES

Tremline. Fascia System. Installation Procedures

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights


ROOF DETAIL RD-16 CONSTRUCTION DOCUMENTS - PHASE / PENNSYLVANIA HOUSING FINANCE AGENCY/ MAY 22, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.

SECTION FLASHING AND SHEET METAL

UNIVERSITY OF SOUTH CAROLINA SUMTER SCIENCE BUILDING ROOF REPLACEMENT WMBE PROJECT NUMBER:

ASHLEY AVE. PARKING GARAGE CHILLER TOWER ROOF REPAIRS

Fascia Systems. oofing 7.1

DISVISON 8: DOORS, WINDOWS AND GLASS SECTION 07600: SHEET METAL FLASHING AND TRIM

Buncombe County Schools. Project Address: 21 Trinity Chapel Road, Asheville, North Carolina Abbreviations

GENFLEX TPO DETAILS. PIPE FLASHING T-7.01A Pipe Boot Installation - Hot Air Welded 19 T-7.01B Pipe Boot Installation - Peel & Stick 20

Sheet Metal Flashing and Trim

Tuscaloosa Police Station

TYPICAL ROOF CONDITION LAYOUT

July Minimum Fastening Requirements (Fully Adhered)... 5

1. Rough Carpentry for wood nailers, cants, curbs, and blocking and for wood-based, structural-use roof deck and walls: Division 6.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

2017 FRENGER FOOD COURT ROOFING PROJECT

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

Pre-Fabricated Roof Curbs

SECTION ROOF SPECIALTIES

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

ADDENDUM No. 2 Park Hill School District 2019 Roofing Projects January 30, 2019

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

SECTION 07530CP EPDM MEMBRANE ROOFING

Coal Tar Application and Design Considerations

G October 2018

Shepard & Associates, LLC

APPLICATION SAFETY TOOLS REQUIRED

METACRYLICS ACRYLIC ROOF TOP PENETRATION ROOF DETAILS

Roof Replacement Specifications Section METHOD SPECIFICATONS, ROOF REPLACEMENT AT THE LOG COLLEGE MIDDLE SCHOOL. CENTENNIAL SCHOOL DISTRICT:

2018 FRENGER FOOD COURT ROOFING PROJECT

The better way to build TM. Installation Manual NAILBASE PANELS

Tarco LeakBarrier EasySystem SBS Self-Adhered Modified Bitumen Roofing System

SECTION ADHERED SINGLE PLY MEMBRANE ROOFING

G October 2018

Roofing Products International Re-Flex TPO Fully Adhered Installation Specification

Product Technical Bulletin APS-5T

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION

ROOFING APPLICATION STANDARD (RAS) No. 111 STANDARD REQUIREMENTS FOR ATTACHMENT OF PERIMETER WOODBLOCKING AND METAL FLASHING

ROOF DETAILS RD-0 CONSTRUCTION DOCUMENTS - AGENCY/ FEBRUARY 13, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.

ROOFING APPLICATION STANDARD (RAS) No. 118 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Counter Battens Only

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

A. Coordinate Roof Assembly roof insulation work with work before and after. See especially:

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

TPO and PVC Roof Flashings and Accessories

UNIVERSITY OF MISSOURI Division 07 Thermal and Moisture Protection Roofing:

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

UBC Technical Guidelines Section Edition Membrane Roofing Page 1 of 7..1 Section Building Envelope General Requirements

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

Shepard & Associates, LLC

Revised Jan-15 Sheet Metal Flashing

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Tarco LeakBarrier EasyTorch APP Torch Applied Modified Bitumen Roofing System

The Alabama Building Commission has adopted the 2006 International Energy Conservation Code as the State Energy Conservation Code

Product Technical Bulletin SPM-4H-250

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

SHEET METAL CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

Architectural Roof and Wall Products Guide Specifications

SECTION FLASHING AND SHEET METAL

DIVISION 7 THERMAL AND MOISTURE PROTECTION

ROOF DRAINS TABLE OF CONTENTS

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

REROOFING ANALYSIS OF K-12 BUILDING. Unified School District 306 Gypsum, Kansas

Schedule A Development Permit No Issued this 18 day of April, 2018

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION FLASHING AND SHEET METAL

Installation Guide. Mission Tile. Distributed by: BEST MATERIALS LLC, Phoenx AZ

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

Architectural Roof and Wall Products Guide Specifications

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.

RS24-10 Single-Section Skylight System

DIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING

ROOFING STUDY GUIDE ARCHITECTURAL SHEET METAL

OREGON ROOF CONSULTING - ROOF INSPECTION FORM

MEMBRANE ROOFING Christ on the Mountain

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Master Guide Specification Page 1

Update In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING

SECTION HVAC GRAVITY VENTILATORS

Architectural Inspection Pitched Roofing

Procurement and Contracting Services

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

C. All roofs shall be installed according to manufacturers guidelines. Corrections due to workmanship shall be at contractors expense.

Transcription:

NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. 1/2 MIN. 10 0 MAX. FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS 3-1/2 MIN. 4 6 JOINT COVER PLATE SET IN TWO BEADS OF SEALANT 4 MIN. SPECIFIED CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 NOTE: SECURE COVER PLATE USING TWO FASTENERS WITH NEOPRENE GASKETS AT THE CENTER OF EACH FASCIA SECTION Light-Metal Roof Edge, Raised 5-1

NAILS 3 O.C. STAGGERED 2 ROWS METAL SET IN SPECIFIED MASTIC PRIME FLANGE BEFORE SPECIFIED MASTIC 1/2 MIN. 10 0 MAX. JOINT COVER 4 6 WIDE SET IN SPECIFIED MASTIC AND SECURED USING TWO FASTENERS THROUGH THE GAP IN THE FASCIA FLANGE TWO-PLY FELT ENVELOPE CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 Light-Metal Roof Edge 5-2

NOT TO SCALE PLIES EITHER OVER OR UNDER WOOD CANT AS SPECIFIED ELASTOMERIC SHEET FLASHING AS SPECIFIED. APPLY ADHESIVE FULL WIDTH. WOOD CANT STRIP NAILED TO BLOCKING SPECIFIED APPROX. 1 CANT. MIN. 1 MINIMUM 1,y APPROX. 1 NOT TO SCALE TremLine Fascia Metal Roof Edge 5-3

TWO-PLY MECHANICALLY FASTEN, STAGGER 3 O.C. METAL FLANGE SET IN SPECIFIED MASTIC PRIME FLANGE BEFORE. GRAVEL GUARD REQUIRED FOR GRAVEL SURFACED ROOFS GRAVEL ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATE SHEET I-49 FELT ENVELOPE GUTTER BRACKET 36 O.C. DRY SHEET GUTTER SPACER 36 O.C. STAGGERED ALTERNATELY (18 ) WITH BRACKETS SLOPE GUTTER TO DOWNSPOUTS 1/4 IN./FT. MINIMUM Roof Edge with Gutter 5-4

SPECIFIED SEALANT COUNTERFLASHING INSTALLED INTO REGLET AND SECURED WITH LEAD WEDGES 8 O.C. FASTENERS 6 O.C. NAILED VENTED BASE SHEET NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED TWO-PLY BASE FLASHING SPECIFIED, NAILED VENTED BASE SHEET LIGHTWEIGHT INSULATING CONCRETE NOTE: MECHANICALLY ATTACH VENTED BASE SHEET OVER FOIL LAMINATED BARRIER SHEET Base Flashing for Vented Base Sheet 5-5

STRUCTURAL SECTION COUNTERFLASHING FASTENED AS NECESSARY WELD PLATE WATERTIGHT 8 MIN. FASTENERS 8 O.C. INSULATE TO PREVENT CONDENSATION TWO-PLY NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. I-Beam Flashing 5-6

LEAD CAP 1 DOWN INTO PIPE 2 MIN. ROLLED LEAD FLASHING 1 DOWN INTO PIPE SET LEAD FLANGE IN SPECIFIED MASTIC FOR PLUMBING VENTS WITH PERIMETERS LESS THAN 2 : USE LEAD CAPS OPTIONAL: SOLDER STAINLESS STEEL SCREEN PLUMBING VENT STACK MASTIC SEAL AT PERIMETER 4 MIN. TWO-PLY NOTE: 1. SHEET LEAD: MINIMUM 4 LB. PER SQ. FT. 2. SHEET COPPER: MINIMUM 16 OZ. IF COPPER FLASHING IS INSTALLED OVER AN IRON OR STEEL PIPE, WRAP AN ASPHALT COATED FELT TO PREVENT DIRECT CONTACT BETWEEN TWO DISSIMILAR METALS. Plumbing Vent Flashing 5-7

METAL SIDING METAL DRIP FLASHING FASTENED 8 O.C. TERMINATION BAR FASTENED 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED 4 MIN. SPECIFIED GRAVEL Metal Wall Flashing 5-8

SPECIFIED SEALANT ONE PIECE COUNTERFLASHING INSTALLED INTO REGLET AND SECURED WITH LEAD WEDGES, 8 O.C. FLEXIBLE VAPOR RETARDER TO SERVE AS RETAINER FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING, 2 ROWS STAGGERED EACH ROW 12 O.C. SPECIFIED COMPRESSIBLE TO DECK WITH APPROPRIATE FASTENERS, 2 ROWS STAGGERED Wall Flashing for Non-Wall Supported Deck 5-9

SPECIFIED SEALANT FASTENERS 24 O.C. MINIMUM TWO PIECE COUNTERFLASHING INSTALLED INTO RECEIVER; 3 OVERLAP AT JOINTS OPTIONAL: 2 WIDE CLIP OPTIONAL: SEAL TOP OF FLASHING WITH 3 COURSES OF ASPHALT MASTIC AND REINFORCING MESH FASTENERS 6 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED SPECIFIED TWO-PLY BASE FLASHING Wall Flashing Wall Supported Deck 5-10

COMPRESSIBLE BUTYL GASKET TAPE TO SPAN IRREGULARITIES TERMINATION BAR FASTENED 8 O.C. SPECIFIED SEALANT SURFACE MOUNTED COUNTERFLASHING FASTENED 8 O.C. MINIMUM ELASTOMERIC FLASHING SPECIFIED NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED Wall Flashing for Concrete Walls and Parapets 5-11

SHEET METAL COVER AS SPECIFIED FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. 2-PLY Wood Curb 5-12

16 GA. MIN. FRAME SEALANT TAPE AS SPECIFIED WOOD NAILER 2 O.C. COUNTERFLASHING FASTENED 18 O.C. 8 MIN. FASTENER 8 O.C. TWO-PLY BASE FLASHING ADHERED TWO-PLY ALTERNATE FRAME LOCATION FOR HEAVY UNITS NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. Curb for Air Handling Unit 5-13

SHEET METAL HOOD CROSS BREAK OR SLOPE FOR DRAINAGE SEAL METAL SCREW INSULATE INSIDE OF METAL WORK IN COLD CLIMATES CLOSURE DETAIL SHEET METAL COLLAR FASTENERS 8 O.C. SLOPE PIPES DOWN AND AWAY FROM HOOD TWO-PLY FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME METAL FLANGE BEFORE. Piping through Roof Deck 5-14

STRAINER / DOME CLAMPING RING 4# LEAD FLASHING ELASTOMERIC TAPER TO DRAIN TURN 4# LEAD DOWN INTO DRAIN 1 DECK CLAMP Roof Drain 5-15

GRAVEL STOP SPECIFIED SEALANT SOLDER OR SEAL SECTION A A B A A B SECTION B B TWO-PLY NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED SEAL TOP OF FLANGE METAL SLEEVE THROUGH SCUPPER GRAVEL STOP Scupper 5-16

METAL PITCH PAN WITH METAL HOOD SPECIFIED DRAWBAND AND SEALANT FILL TO TOP OF PAN WITH SPECIFIED MASTIC MASTIC SEAL AT PERIMETER TWO-PLY FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE Pitch Pocket 5-17

SPECIFIED DRAWBAND AND SEALANT METAL PITCH PAN WITH METAL HOOD FILL 1 FROM TOP WITH NON-SHRINK GROUT, TOP OFF WITH SPECIFIED MASTIC MASTIC SEAL AT PERIMETER ELASTOMERIC,, SYSTEM FLANGE SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE Pitch Pocket with Grout 5-18

STORM COLLAR CAULK DRAW BAND WITH SPECIFIED ELASTOMERIC SEALANT SET IN SPECIFIED MASTIC. MECHANICALLY FASTENED 3 O.C. PRIME FLANGE BEFORE TWO-PLY PROJECTION Metal Sleeve and Storm Collar 5-19

STRUCTURAL FRAME PIPE COLUMN STRUCTURAL FRAME UMBRELLA ATTACHED WITH DRAWBAND CAULK WITH SPECIFIED ELASTOMERIC SEALANT MASTIC SEAL AT PERIMETER TWO-PLY 4 MINIMUM WELDED ANCHOR PLATE SINGLE LAYER COMPRESSIBLE NAIL FLANGE TO WOOD NAILER, FLANGE SET IN MASTIC OVER, PRIME FLANGE BEFORE Equipment Stand (Pipe) 5-20

SET BOLT IN ELASTOMERIC SEALANT. CAULK PERIMETER OF LEG & FASTENER. NEOPRENE PAD LEG 14 MIN. FASTENERS 24 O.C. ONE-PIECE COUNTERFLASHING 8 MIN. FASTENERS 8 O.C. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. Equipment or Sign Support 5-21

SECTION A A A 10 0 MAX. A BASE SHEET LINER OVER NAILER SEAL SLOPE INWARD NEOPRENE GASKETED FASTENERS 24 O.C. BASE FLASHING AS SPECIFIED NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 24 O.C. SPECIFIED 4 MIN. CONTINUOUS CLEAT FASTENED 16 O.C. ATTACH NAILER TO WALL REFER TO FACTORY MUTUAL DATA SHEET 1-49 Light-Metal Parapet Cap 5-22

FLEXIBLE IMPERVIOUS MEMBRANE ADHERED TO VAPOR RETARDER FLEXIBLE VAPOR RETARDER TO SERVE AS RETAINER FASTENERS 8 O.C. BOTH SIDES CHAMFER EACH SIDE OF WOOD CURB TO DRAIN FASTEN 18 O.C. WITH NEOPRENE GASKETED FASTENERS SEAL 8 MIN. NAIL WOOD CANT TO BLOCKING 2 ROWS STAGGERED EACH ROW 12 O.C. REINFORCED ELASTOMERIC FLASHING MEMBRANE INORGANIC COMPRESSIBLE SPECIFIED SLOPE Expansion Joint 5-23

SEAL EDGE WITH REINFORCING MESH AND ASPHALT MASTIC EXTEND NEW 12 ONTO PREPARED AREA EXISTING NEW REMOVE EMBEDDED GRAVEL / DEBRIS MINIMUM 18 12 AND 18 PLY SHEETS ADHERED IN SPECIFIED ADHESIVE EXISTING DECK * BEFORE NEXT DAY S WORK, REMOVE TEMPORARY TIE-IN AND FILLERS Daily Waterstop / Tie-In 5-24

SEAL EDGE WITH REINFORCING MESH AND ASPHALT MASTIC EXTEND NEW 12 ONTO PREPARED AREA EXISTING NEW REMOVE EMBEDDED GRAVEL / DEBRIS 18 12 AND 18 PLY SHEETS ADHERED IN SPECIFIED MASTIC EXISTING DECK Permanent Tie-In 5-25

A A A COPING CAP FLASHING AND FASCIA VARIATIONS EXPOSED FACE WITHOUT BRAKES A DIMENSIONS GALVANIZED IRON COLD ROLLED COPPER ALUMINUM 3003-H14 UP TO 6 FACE 24 GA. 16 OZ..040 (18 GA.) 6 TO 8 FACE 24 GA. 16 OZ..050 (16 GA.) 8 TO 10 FACE 22 GA. 20 OZ..064 (14 GA.) 10 TO 15 FACE 20 GA. ADD BRAKES TO STIFFEN.080 (12 GA.) Gauge or Thickness Guide (Minimum) 5-26