DS/EN DK NA:2015

Similar documents
DS/EN DK NA:2013

DS/EN DK NA:2010

DS/EN DK NA:2013

DS/EN DK NA:2013

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

EN DK NA:2007

Design of Beam-Columns

DIN EN : (E)

STAAD.Pro V8i. STAAD.Pro V8i. STAAD.Pro V8i AD Features Affecting the Analysis and Design Engine

CLT Structural Design Sylvain Gagnon, Eng. February 8, 2011 Vancouver

Structural Dynamics and Earthquake Engineering

Design of Steel-Concrete Composite Bridges

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING. BEng (Hons) CIVIL ENGINEERING

BS EN :2004 EN :2004 (E)

Steel structures I INTRODUCTION Steel structures Structural elements Structural design Design methods Euro code Chapter 2 LIMIT STATE DESIGN Limit

STEEL DESIGNERS MANUAL

BEHAVIOUR OF COLD-FORMED Z-SHAPED STEEL PURLIN IN FIRE

1. BS 5950: Structural use of steelwork in building Part 1: Code of practice for design of simple and continuous construction, BSI, 1990

TECHNICAL MANUAL. PETRA Slab Hanger. Hollow-Core Support for Slab Openings

SOUTH AFRICAN NATIONAL STANDARD

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL COLLEGE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2018/2019

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 9: Introduction to Computer Software

Tekla Structural Designer 2016

Experimental and numerical validation of the technical solution of a brace with pinned connections for seismic-resistant multi-story structures

Content. Introduction Amendments EN Other ongoing work Conclusions

CIVL473 Fundamentals of Steel Design

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

midas Gen MIDAS On-Demand Service midas Gen Advanced Webinar Steel Structure Design

Effect of lateral support of compression flange to stability of beam-columns

PRINCIPLES OF CONCRETE DESIGN

Sabah Shawkat Cabinet of Structural Engineering 2017

BEHAVIOUR OF BUILDING FRAMES WITH STEEL PLATE SHEAR WALLS

PC Beam Shoe. Corbel system to support beams. Technical Manual. Version: DK 4/2012 Design standard: DS EN Eurocodes + NA (Denmark)

Timber-steel-hybrid beams for multi-storey buildings

Fundamentals for Steel Constructions

CYS National Annex to CYS EN :2005

Contents. Tables. Terminology and Notations. Foreword. xxi

Full-scale tests on steel frames under cyclic loading

Design of Laterally Unrestrained Beams

30 kip/ft (Dead load) 5 ft. 20 ft

Simple Complex Simple Complex

The Behaviour of Beam-Column Elements with Variable I Cross-Sections considering Lateral Restraints

Level 6 Graduate Diploma in Engineering Structural analysis

Universal Beam and Universal Column sections subject to pure bending are all Class 3 semi-compact or better.

Behaviour of single storey frames with tapered web members accounting for manufacturing and assembling imperfections

mortarless Design Manual Part 3 (AS 3600:2009) Section 2 Page: DESIGN OF WALLS FOR AXIAL COMPRESSION USING SIMPLIFIED DESIGN METHOD

Compression Members. Columns I. Summary: Objectives: References: Contents:

Demountable Shear Connectors for Sustainable Composite Construction

Application nr. 6 (Connections) Strength of welded connections to EN (Eurocode 3, Part 1.8)

Survey and Testing of Pre-1988 Braced Frame Structures From The West Coast of the United States

7 LOCAL BUCKLING OF STEEL CLASS 4 SECTION BEAMS

Structural Steel and Timber Design SAB3233. Topic 8 Columns Design. Prof Dr Shahrin Mohammad

Eurocodes European Codes for Structural Design. H. J. Bossenmayer, Prof. Dr.-Ing., is president, Deutsches Institut für Bautechnik, Berlin, Germany

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Eurocode 9: Design of aluminium structures

15.2 Approximate Analysis of a Continuous Beam for Gravity Load

Structural Behaviour and Detailing

THE ROLE OF COMPOSITE JOINTS ON THE PERFORMANCE OF STEEL-FRAMED BUILDINGS IN FIRE. Prof. Khalifa S. Al-Jabri

FIRE RESISTANCE ASSESSMENT OF PARTIALLY PROTECTED COMPOSITE FLOORS (FRACOF) DESIGN GUIDE

Harmonising the Australian Standard AS4100: Steel Structures

CADS A3D MAX. How to model shear walls

DESIGN OF HIGH-RISE MODULAR OPEN BUILDINGS

10-COLUMNS: 10.1 Introduction.

NUMERICAL SIMULATION OF CATENARY ACTION IN COLD-FORMED STEEL SHEETING IN FIRE. Jyri Outinen Vol. 40, No. 3, 2007, pp

SINbeam design software Please be patient as the software opens.

Material Requirements for Steel and Concrete Structures

Advanced Eurocode Training. EN : Composite Structures

Quasi-Static Testing and Correlative Dynamic Analysis of Concentrically Braced Frames with Hollow Steel Braces and Gusset Plate Connections

There are countless ways to improve constructability on your next project. Here are 50 of them. the need for it or specify it on the design drawings.

Release Notes for RISA-3D

Structural Design of Pergola with Airfoil Louvers

Structural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design

Eurocode Training EN : Composite Structures

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

(a) Pin-Pin P cr = (b) Fixed-Fixed P cr = (d) Fixed-Pin P cr =

TABLE OF CONTENTS PREFACE

ST4 Steel Girder Support. FRILO Software GmbH As of Version 2/2015

RECOMMENDATION DOCUMENT FOR THE DESIGN OF PREQUALIFIED PRECAST CONCRETE BOLTED CONNECTIONS FOR SEISMIC APPLICATIONS (SA_LJ2015)

Axial load behaviour of pierced profiled composite walls

twenty one steel construction: bolted & welded connections ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2015 lecture

BASES OF DESIGN OF OVERHEAD ELECTRICAL LINES ACCORDING TO GENERAL REQUIREMENTS OF EUROPEAN STANDARD EN : 2001

FRA COF. Design Guide. O. Vassart B. Zhao. Fire Resistance Assessment of Partially Protected Composite Floors

TABLE OF CONTENTS FINITE ELEMENT MODELING OF CONCRETE FILLED DOUBLE SKIN

How Beams Work, I. Statics and Strength of Materials

STEEL BUILDINGS IN EUROPE. Multi-Storey Steel Buildings Part 4: Detailed Design

Tekla Structural Designer 2017

STEEL REACTION FRAME

APPENDIX B ABC STRUCTURES DESIGN GUIDE

Design check of BRBF system according to Eurocode 8 Use of pushover analysis

Hours / 100 Marks Seat No.

University of Waterloo Department of Mechanical Engineering ME MACHINE DESIGN 1. Fall 2005

Fundamentals of Structural Design Part of Steel Structures

Multi storey buildings

CHAPTER FIVE 5.1 MODELING OF A TEN-STOREY BUILDING

xiii Preface to the Fifth Edition Preface to the Second Edition Factors for Conversion to SI Units of

6. Modelling and analysis

ANNEX 10. Special requirements recommended for structures subject to seismic actions. 1 Scope. 2 Basis of design. 2.1 Fundamental requirements

Innovative Dissipative (INERD) Pin Connections for Seismic Resistant Braced Frames

The need to design for robustness in fire. Ian Burgess

Comparative Study of R.C.C and Steel Concrete Composite Structures

Transcription:

National Annex to Eurocode 3: Design of steel structures Part 1-1: General rules and rules for buildings Foreword This national annex (NA) is a revision of DS/EN 1993-1-1 DK NA:2014 and replaces the latter on 2015-01-01. In addition to minor editorial changes, the publication of DS/EN 1993-1-1/A1:2014 has resulted in the addition of national choices in C.2.2(3) and C.2.2(4); the complementary regarding 2.1.2 has consequently been deleted. Previous versions of and addenda to this NA as well as an overview of all NAs can be found at www.eurocodes.dk This NA lays down the conditions for the implementation in Denmark of EN 1993-1-1 for construction works in conformity with the Danish Building Act or the building legislation. Other parties can put this NA into effect by referring thereto. A National Annex contains national provisions, viz. nationally applicable values or selected methods. The Annex may furthermore give complementary, non-contradictory. This NA includes: an overview of possible national choices and clauses containing complementary ; national choices; complementary, non-contradictory. Foreword Page 1 of 8

Overview of possible national choices and complementary The list below identifies the clauses where national choices are possible and the applicable/not applicable informative annexes. Furthermore, clauses giving complementary are identified. Complementary is given at the end of this National Annex. Clause Subject National choice 1) Complementary 2.3.1(1) Actions and environmental influences Unchanged 3.1(2) Materials, General National choice 3.2.1(1) Material properties National choice 3.2.2(1) Ductility requirements Unchanged 3.2.3(1) Fracture toughness" Unchanged 3.2.3(3)B Fracture toughness" Unchanged 3.2.4(1)B Through-thickness properties Unchanged Complementary 5.2.1(3) Effects of deformed geometry of the structure National choice 5.2.2(8) Structural stability of frames Complementary 5.3.2(3) Imperfections for global analysis of frames Unchanged 5.3.2(11) Imperfections for global analysis of frames National choice 5.3.4(3) Member imperfections Unchanged 6.1(1) National choice 6.1(1)2B Ultimate limit states, General National choice 6.2.2 Resistance of cross-sections - Section properties 6.3.2.2(2) Lateral torsional buckling curves General case 6.3.2.3(1) Lateral torsional buckling curves for rolled sections or equivalent welded sections 6.3.2.3(2) Lateral torsional buckling curves for rolled sections or equivalent welded sections 6.3.2.4(1)B 6.3.2.4(2)B Simplified assessment methods for beams with restraints in buildings Simplified assessment methods for beams with restraints in buildings 6.3.3(5) Interactive factors for members in bending and axial compression Unchanged Unchanged National choice Unchanged Unchanged National choice Complementary Complementary Complementary Page 2 of 8 Overview, national choices and complementary

Clause Subject National choice 1) Complementary 6.3.4(1) General method for lateral and lateral torsional buckling of structural components National choice 7.2.1(1)B Vertical deflections National choice 7.2.2(1)B Horizontal deflections National choice 7.2.3(1)B Dynamic effects Unchanged Annex A Applicable Annex B Applicable Complementary Annex AB Annex BB Applicable Applicable BB.1.3(3)B Hollow sections as members National choice C.2.2(3) Selection of execution class - general National choice C.2.2(4) Selection of execution class - components National choice 1) Unchanged: The recommendation in the Eurocode is followed. No choice made: The Eurocode does not recommend values or methods, but allows the option of determining national values or methods. Not applicable The Annex is not applicable. Applicable The Annex is applicable in Denmark and has the same status as specified in the Eurocode. National choice: A national choice has been made. Not relevant for building structures: See the National Annexes published by the Danish Road Directorate and Banedanmark. Page 3 of 8 Overview, national choices and complementary

National choices 3.1(2) Materials, General The standard applies to steel materials in accordance with Table 3.1 of DS/EN 1993-1-1 or equivalent. 3.2.1(1) Material properties The values of fy and fu specified in (1) a) should be used. 5.2.1(3) Effects of deformed geometry of the structure A lower value of αcr than that that given in (5.1) may be used if justification of its application is documented. 5.3.2(11) Imperfections for global analysis of frames Which of the methods referred to in (3), (6) and (11) to be used should be determined for each individual case. 6.1(1) Ultimate limit states, General The below expressions for Mi are used, including the factor (γ0) on the partial factors for strength parameters and resistances, cf. National Annex to EN 1990, Table A1.2(B+C) DK NA: M0 = 1,1 0 3 M1 = 1,2 0 3 M2 = 1,35 0 3 The factor 0 takes into account the combination of actions, cf. National Annex to EN 1990, Table A1.2(B+C) DK NA. Limit state STR/GEO STR Combination of actions 1 2 3 4 5 0 1,0 1,0 K FI K FI 1,2 K FI The factor 3 takes into account the level of checking of the product. The reduced level of checking is not used. Extended level of checking: 3 = 0,95 Normal level of checking: 3 = 1,00 The partial factors are determined in accordance with the National Annex to EN 1990, Annex F, Partial factors for resistance, where γm = γ1 γ2 γ3 γ4, where the values of γmi given above include the factor 0. National choices Page 4 of 8

γ1 γ2 model; γ3 γ4 takes into account the type of failure; takes into account the uncertainty related to the design takes into account the extent of checking; takes into account the variation of the strength parameter or resistance. When determining γ1, the following types of failure have been assumed: M0: M1: M2: Warning of failure with residual resistance Warning of failure without residual resistance No warning of failure For accidental and seismic design situations the following values are used: M0 = 1,0 M1 = 1,0 M2 = 1,0 6.1(1)NOTE 2B Ultimate limit states, General See 6.1(1) 6.3.2.3(2) Lateral torsional buckling curves for rolled sections or equivalent welded sections f = 1. The determination of Mcr takes into account the moment distribution between lateral restraints. See also the complementary. 6.3.3(5) Uniform members in bending and axial compression Both Method 1 and Method 2 may be used to determine the values of the interaction factors kyy, kyz, kzy and kzz. See also the complementary. 6.3.4(1) General method for lateral and lateral torsional buckling of structural components The relevance of using the method in 6.3.4 is to be evaluated for each case. 7.2.1(1)B Vertical deflections For beams, the following values of the maximum deflection (w3 in EN 1990, Figure A1.1) due to one variable action without allowance for impact, if any, may serve as guidance as to what may be regarded as acceptable deflections: floors l/400 roofs and external walls l/200 Where l is: the span of simply supported and continuous beams; twice the projection of cantilevered structures. The values apply both to main and secondary elements, but only the deflection of the element considered is to be used in the assessment. National choices Page 5 of 8

For secondary sheeting in the form of uninsulated roof sheeting and for facade sheeting, the deflection due to permanent and variable actions should not exceed l/90. For roof sheeting with external insulation and roofing felt, the deflection due to permanent and variable actions should not exceed: l/150 for l < 4 500 mm 30 mm for 4 500 mm l < 6 000 mm l/200 for 6 000 mm l 7.2.2(1)B Horizontal deflections For columns, the following numerical values of the maximum deflection of the column head due to one variable action may serve as guidance to what may be regarded as acceptable deflections: frames in buildings without cranes h/150 columns in single-storey skeleton structures h/300 columns in multi-storey skeleton structures, for each storey h/300 for the total height he /500 Where h is the height of the individual column he is the total height of the building. BB.1.3(3)B Hollow sections as members Further on buckling lengths of compression members should be found in textbooks. C.2.2(3) Selection of execution class The execution class is selected on the basis of the consequences class. Table C.1 DK NA Selection of execution class (EXC) Consequences class Type of action Static, quasi-static or seismic DCL a) Fatigue b) or seismic DCM or DCH a) CC3 EXC3 c) EXC3 c) CC2 EXC2 EXC3 CC1 EXC1/EXC2 d) EXC2 a) Seismic ductility classes are defined in DS/EN 1998-1: Low = DCL, medium = DCM, high = DCH. b) See DS/EN 1993-1-9. c) EXC4 should be used for structural components where the consequences of failure are particularly serious. d) EXC2 for welds. See C.2.2(4). National choices Page 6 of 8

C.2.2(4) Selection of execution class For the execution of welds, DS/EN 1993-1-8 specifies that a weld of at least quality level C (according to DS/EN ISO 5817) is normally required unless otherwise specified. Therefore, at least execution class EXC2 should be applied for the welded connections in the structure. For structures of consequences class CC1, EXC1 may be used for the fillet weld if the throat thickness of the fillet weld is increased by 20 %, and quality level C is applied with the exception that quality level D can be applied for "Undercut" (5011, 5012), "Overlap" (506), "Stray arc" (601) and "End crater pipe" (2025). National choices Page 7 of 8

Complementary, non-contradictory 3.2.4(1) Through-thickness properties It is recommended that structural components subject to stress in the through-thickness direction should be protected against lamination according to DS/EN 10160, class S1. 5.2.2(8) Structural stability of frames Detailed guidelines are not given for structural analyses of the stability of frames using a method based on equivalent buckling lengths. Guidance should be found in specialist literature or the method of analysis should be documented by other means. 6.2.2 Resistance of cross-sections - Section properties For a long-threaded structural component, the gross cross section and the net cross section are taken as the stress area as defined in DS/EN 1993-1-8, 1.5. The connection at the end of the component should also conform to the design rules for bolted connections specified in DS/EN 1993-1-8. 6.3.2.3(2) Lateral torsional buckling curves General case Justification for changing 6.3.2.3(2) Lateral torsional buckling curves for rolled sections or equivalent welded sections The specified method assumes (cf. ECCS Publication 119) that when calculating Mcr and consequently λlt, a uniform moment distribution between the lateral restraints is taken into account corresponding to Ψ = 1 in Table 6.6, and not the real moment distribution as in 6.3.2.2. The real moment distribution has been taken into account by the factor f. The text of the change specifies that also when using this method, Mcr is to be determined on the basis of the real moment distribution between the lateral restraints, and f is taken as 1. 6.3.3(5) Uniform members in bending and axial compression Method 1 is recommended for significant structures and where cost is decisive, and as a basis for the preparation for design programs. Method 2 is recommended as a simpler method for less significant structures. See also the national choice. Annex B, Method 2 Interaction factors kij for interaction formula in 6.3.3(4) Table B.3: Equivalent uniform moment factors Cm in Tables B.1 and B.2 Ms is to be obtained according to the value of bending moment diagram which yields a local extreme (dms/dx = 0) between end points of beam elements (x = 0 and x = L). Where a local extreme does not exist, Ms is to be taken as the value obtained at the centre of the beam element. Complementary Page 8 of 8