MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

Similar documents
SECTION CAST-IN-PLACE CONCRETE

SECTION CAST-IN-PLACE CONCRETE

SECTION RIGID PAVEMENT

SECTION CONCRETE. B. ACI 318 Building Code Requirements for Structural Concrete and Commentary

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

SECTION MISCELLANEOUS CAST-IN-PLACE CONCRETE

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

SECTION RIGID PAVEMENT. 1. Portland Cement Concrete (PCC) pavement. 2. Section Aggregate Base Course.

SECTION CAST IN PLACE CONCRETE PART 1 GENERAL 1.01 RELATED DOCUMENTS

Columbia Public Schools Shepard Elementary School Classroom Building Addition PWA I 1 CONCRETE REINFORCEMENT ~4 ASSURANCE

AMERICAN SAMOA POWER AUTHORITY Materials Management Office INVITATION FOR BIDS ( IFB ) UTULEI & VATIA PRV CONCRETE VAULT CONSTRUCTION

DIVISION 3 CONCRETE SECTION CAST-IN-PLACE CONCRETE

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON HEMPCRETE

SECTION CONCRETE PAVING

SECTION CONCRETE CURBS, GUTTERS AND SIDEWALKS

SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

San Antonio Water System Standard Specifications for Construction ITEM NO. 307 CONCRETE STRUCTURES

CONCRETE WALKS AND CURBS SECTION CONCRETE WALKS AND CURBS PART 1 - GENERAL

ITEM NO. 307 CONCRETE STRUCTURES

SECTION Arisfor WallGuard

GYPSUM BOARD AND PLASTER

SECTION CAST-IN-PLACE CONCRETE

SECTION US Patent 8,857,130 B1 CAST-IN-PLACE CONCRETE WITH ARDEX CONCRETE MANAGEMENT SYSTEMS (ACMS ) EARLY MC APPLICATION

***************************************************************************************************************

SECTION CAST-IN-PLACE CONCRETE FOR UTILITIES

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) MASONRY [BLOCKS] [BRICKS] [STONE]

SECTION CONCRETE CURBS, GUTTERS AND SIDEWALKS. A. Formwork complete with shoring, bracing and anchorage.

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

SECTION CONCRETE FORMWORK AND ACCESSORIES

DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340

1. Payment for concrete sidewalks is on square foot basis. a. Limits for measurement for trench excavation as follows:

INTEGRALLY COLORED CONCRETE [DECORATIVE CONCRETE PAVING]

SECTION CAST-IN-PLACE CONCRETE

MANUFACTURER S SPECIFICATIONS Section LIMESTONE PLASTER

SECTION CONCRETE PAVING FOR PEDESTRIAN AREAS. A. This Section includes exterior cement concrete pavement for the following:

A. Submittal Procedures: See Article 13 of the General Conditions.

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

1. Manufacturer certified according to NRMCA's "Certification of Ready Mixed Concrete Production Facilities."

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Polycrete Big Block Standard Specification

SECTION UNIT MASONRY

CONCRETE WORK CONCRETE WORK. Underground Electric Distribution Standards I. SCOPE APPLICABLE STANDARDS

SECTION CONCRETE CURB AND GUTTER, SIDEWALKS, AND DRIVEWAYS

DIVISION 03 CONCRETE CONCRETE REINFORCING Reinforcing Steel Welded Wire Fabric Reinforcing Fibrous Reinforcing

Section CONCRETE SIDEWALKS. 1. Payment for concrete sidewalks is on square foot basis.

SECTION CONCRETE FORMWORK

SECTION TERRAZZO FLOOR TILE

DIVISION 03 CONCRETE. Section Title Number CONCRETE

SECTION WALL AND DOOR PROTECTION

DIVISION 03 CONCRETE. Number CONCRETE

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

Proudly Made in the U.S.A.

SECTION CAST-IN-PLACE CONCRETE

Dryshake CSI Format Section 07160

SECTION UNIT MASONRY

Attachment A-Flagpole(s) Specifications

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB

SECTION UTILITY MANHOLES AND STRUCTURES

REINFORCED CONCRETE MASONRY SECTION

TECHNICAL SPECIFICATION

SECTION PRECAST CONCRETE BIOSOLIDS STORAGE TANK

SECTION MORTAR

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

SECTION SURFACE-APPLIED CRYSTALLINE WATERPROOFING AND CONCRETE REPAIR

A. Section Concrete Reinforcing: Reinforcing steel to be placed at the same time as formwork specified in this section.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 03 - CONCRETE

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

SECTION INSULATED CONCRETE FORMS - RASTRA 1.01 SUMMARY

Pulaski County, Virginia

ITEM 431 PNEUMATICALLY PLACED CONCRETE. All material shall conform to the pertinent requirements of the following items:

SECTION INTERLOCKING PRECAST CONCRETE UNIT PAVERS

DIVISION 3 CONCRETE BUSHEY FEIGHT MORIN ARCHITECTS INC. 473 NORTH POTOMAC STREET HAGERSTOWN, MARYLAND FAX:

SECTION ARCHITECTURAL PRECAST CONCRETE. C. Section Joint Sealers: Perimeter joints with sealant and backing.

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

MRXL4 CR6 Surface Requirements: XNS, NS, M, S; Special Requirements: NO PART 1 : GENERAL

BITUMEN-SET PRECAST CONCRETE PAVING SLABS

Page 1 of 1 ADDENDUM NO. 2 PROJECT: THE SALVATION ARMY, THIFT STORE 601 N. EUCLID AVE., BAY CITY, MI WILLIAM A. KIBBE & ASSOCIATES, INC.

SECTION EXPANSION JOINT COVER ASSEMBLIES

.1 Formwork for cast-in-place concrete with shoring, bracing, and anchorage.

CONCRETE FORMWORK. .2 CSA , Supplement No.1 to CAN/CSA , Engineering Design in Wood. .4 CSA O151, Canadian Softwood Plywood.

SECTION PRECAST CONCRETE COVER SYSTEM

1. Cast-in place structural concrete including footers, foundations, and other non-slab applications. 2. Formwork 3. Reinforcement

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company

***************************************************************************************************************

2014 Capital Project Phase 3 Grand Island Central School District Cannon Design Project No SECTION PAVING PART 1 - GENERAL

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

SPECIFICATION GUIDELINE

SECTION UNIT MASONRY ASSEMBLIES

SECTION TILT-UP PRECAST CONCRETE. A. Work includes, but is not limited to, the following:

SECTION CONCRETE FORMWORK

CONSTRUCTION SPECIFICATION FOR CONCRETE CURB AND GUTTER SYSTEMS

Transcription:

MANUFACTURER S SPECIFICATIONS Section 03330 LIME CONCRETE ST. ASTIER NATURAL HYDRAULIC LIME CONCRETE PART 1 GENERAL 1.01 General A. This section describes the requirements for floors and slabs on grade. 1.02 Products furnished but not installed under this section A. [Section 03100 Concrete Formwork: placement of [joint device] [joint device anchors] in formwork.] 1.03 Related sections A. Section [ - ]: Sidewalks, curbs and gutters. B. Section 03100 Concrete Formwork: Formwork and Accessories. C. Section 03200 Concrete Reinforcement. D. Section 03346 Concrete Floor Finishing. E. Section 03370 Concrete Curing. F. Section 05800 Expansion Control. G. Section 09415 Exterior-Interior LimeStone Mortar Le Décor LimeFloor 1.04 References A. ASTM C 33 Concrete Aggregate. B. ASTM C141/C141M - Standard Specification for Hydrated Hydraulic Lime for Structural Purposes. C. European Standard 03330-1 St. Astier Natural

1.05 Quality Insurance 1. EN 459-1 Building Lime Part 1: Definitions, Specifications and Conformity Criteria 2. EN 459-2 Building Lime Part 2: Test Methods 3. EN 459-3 Building Lime Part 3: Conformity Evaluation A. Perform work in accordance with ACI 301. 1.06 Submittals A. Submit under provisions of Section [01300] [ ]. B. Submit manufacturer s installation instructions. 1.07 Project Record Documents A. Accurately record actual locations of embedded utilities and components that are concealed from view. 1.08 Field Samples A. Sample Panel: Sufficient size to indicate special treatment or finish required. B. Locate [where directed] [ ]. C. Accepted sample panel is considered basis of quality for the finished work. Keep sample panel exposed to view for duration of concrete work. D. Accepted panel may [not] remain as part of the Work. PART 2 - PRODUCTS 2.01 Concrete Materials A. Lime: St. Astier Natural Hydraulic Lime: NHL 5. B. Fine and Coarse Aggregate: ASTM [C33] [C330]. C. Water: clean and not detrimental to concrete. 03330-2 St. Astier Natural

D. Glass Fiber Reinforcement: [ASTM C948] [ ]; [ ] manufactured by [ ]. 2.02 Joint Devices and Filler Materials A. [Construction Joint Devices: Integral [galvanized steel] [extruded plastic]; [ ] inch ([ ] mm) thick, formed to tongue and groove profile, [with removable top strip exposing sealant through, ] knockout holes spaced at [6] [ ] inches ( [150] [ ] mm), ribbed steel spikes with tongue to fit top screed edge; [ ] manufactured by [ ].] B. [Expansion [and Contraction] Joint Devices: ASTM B221 [ ] alloy, extruded aluminum; resilient [elastomeric] [vinyl] [neoprene] filler strip with a Shore A hardness of [35] [ ] to permit plus or minus [25] [ ] percent joint movement with full recovery.] 2.03 Concrete Mixes A. Mix in accordance with manufacturer s recommendations. B. Select proportions for concrete in accordance with manufacturer s instructions. C. Provide concrete to the following mix design: Unit Compressive Strength (28 days) Compressive Strength (6 months) [Glass fiber reinforcement Water/Lime Ratio Measurement 1,000 psi (7 mpa) 2,400 psi (17 mpa) [ ] percent by volume] 3-1/2 Gallon by 66 lbs of lime PART 3 EXECUTION 3.01 Inspection A. Verify site conditions under provisions of Section [01039] [ ]. B. Verify requirements for concrete cover over reinforcement. (1-1/2 inch minimum) 03330-3 St. Astier Natural

C. Verify that anchors, seats, plates, reinforcement and other items to be cast into concrete are accurately placed, positioned securely, and will not cause hardship in placing concrete. 3.02 Placing Concrete A. Place concrete in accordance with manufacturer s instructions. B. Notify Architect/Engineer minimum 24 hours prior to commencement of operations. C. Ensure reinforcement, inserts, embedded parts, formed joint fillers [, joint devices] and [ ] are not disturbed during concrete placement. D. Separate slabs on grade from vertical surfaces with [ ] inch ([ ] mm) thick joint filler. E. Install joint devices in accordance with manufacturer s instructions. F. Install joint device anchors. Maintain correct position at allow joint cover flush with floor finish. G. Maintain records of concrete placement. Record date, location, quantity, air temperature, and test samples taken. H. Place concrete continuously between predetermined expansion, control, and construction joints. I. [Do not interrupt successive placement; do not permit cold joints to occur.] J. Place floor slabs in [checkerboard] [ ] pattern indicated. K. Screed [floors] [and] [slabs on grade] level, maintaining surface flatness of maximum [1/4] [ ] inch in 10 ft. ([3] [ ] mm / 3 m). 3.03 Concrete Finishing A. [Finish concrete floor surfaces to requirements of Section. ] B. [Wood float surfaces which will receive [quarry tile] [ceramic tile] [ ] with full bed setting system.] 03330-4 St. Astier Natural

C. Steel trowel surfaces which are scheduled to be exposed. D. In areas with floor drains, maintain floor elevation at walls; pitch surfaces uniformly to drains [at [1/8] [1/4] [ ] inch per foot ([10] [20] [ ] mm per m) nominal] [as indicated on Drawings]. 3.04 Curing and Protection A. Immediately after placement, protect concrete from premature drying, excessively hot or cold temperatures, and mechanical injury. B. Maintain concrete with minimal moisture loss at relatively constant temperature for period necessary for hydration of lime and hardening of concrete. C. Cure concrete floor surfaces according to manufacturer s instructions. D. Spraying: Spray water over floor slab areas and maintain wet for [7] [ ] days. 3.05 Schedule 03330-5 St. Astier Natural