SKC PMI Samplers. 25-mm pre-oiled disposable porous plastic disc; reduces particle bounce

Similar documents
Sioutas Cascade Impactor

Sioutas Cascade Impactor

Size-selective Samplers

Wipes for Disclosing the Presence of Lead

IP-10A METHOD UPDATE. Year DETERMINATION OF FINE PARTICULATE MATTER IN INDOOR AIR USING SIZE-SPECIFIC IMPACTION

Air Sampling for Manganese

International Platinum Group Metal Association (IPA) Harmonised Methodology for the Sampling of Platinum in Workplace Atmospheres

Sampling for particulates

Sampling for particulates

IC Equipment. Ultrafiltration Manual EN

Investigation into Particulate Pollutant Concentration From A Cement Plant: A Case Study Of Obajana Cement Plc, Lokoja, Nigeria

Personal Sampling Overview

450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved)

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

Step by Step Guide An Introduction to Air Sampling Universal Pump

BGI, INC. WALTHAM, MA 02451

ABSTRACT INTRODUCTION

Dekati Solutions. Emission Measurements

BioSampler Operating Instructions SKC Inc. 863 Valley View Road Eighty Four, PA USA

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

Environmental Measurements

Customer Self-Monitoring Program Overview for Airborne Fiber

Employers Guide on How to Conduct A Worker Exposure Assessment for Silica

AerosolInstruments. Micro Technologies, Big Ideas. Product Guide. MSP Corporation Rice Creek Parkway, Suite 300

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the

SERVICE PEDESTAL FLOOR-MOUNTED SERVICE PEDESTAL. Installation Manual

BIOAIRE CASSETTE Impaction Particle Sampler

SUBSTRATES AND FILTERS FOR DEKATI IMPACTORS VER6.3. Introduction. Collection substrates. Dekati Accessory

Standard Operating Procedure for the Sampling and Analysis of Total Suspended Solids in Great Lakes Waters

92831 TEL: (714) FAX:

OPERATING MANUAL. Model 900

ESSENTIAL FOR SURVIVAL

AerosolInstruments. Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U. S. A.

DustCheck DPM-16. Previous Go to PM10-2,5 sampling adding the Wins impactor 9 of 75 Next Go to DustCheck DPM-5. Sequential sampler

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Title: Standard Operating Procedure for Measurement of Particulate Matter in Ambient Air Using the Partisol 2000H

Static Air Sampling Enclosure HB November 2018

Chromic Acid Mist Test Kit Operating Instructions

Impression Graphic panels

Assessment of free floating dust and abrasion particles of treated seeds as a parameter of the quality of treated seeds

Hamilton PRP Polymeric Columns

Gilian BDX-II Air Sampling Pump Setup and Use

Model No. BWTDWFK-TRIFLO.

Industrial flue gas probes. Instruction manual

INSTALLATION MANUAL MOSER STAINLESS STEEL KITCHEN FAUCET MODEL MANCHESTER

Permeation Accessory for the Micro-Chamber/

Circular Expansion Cement Curing Kit Instruction Manual

PTC1. Paint Test Cell Kit

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

A Sterile Processing User s Guide

Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO First edition

CF042P Crossflow Cell Assembly and Operation Manual

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

Aero Tec Models 700 & 750 (115 vac)

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Installation Guide D-Shape

Electron Microscopy Sciences

3M Fast Tack Water Based Adhesive 1000NF

QUICK START GUIDE. EVM Series Environmental Monitor

Experiment # 2 Aerosol and Trace Gas Sampling

Oregon Health Services - Drinking Water Program

DMX AG AIR-GAP MEMBRANE. Section Damproofing and Waterproofing

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

High Temperature Aging Cell Instruction Manual

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

3M Water Filtration Products Model SGLP-RO Reverse Osmosis System- Quick Installation Guide

P-GS STEAM FILTER ELEMENTS. Compressed Air & Process Filtration

Obsolete. Description. Rhinor SD2/XD2 Type-H Follower Modules

INSTALLATION MANUAL RECTANGULAR COLUMN

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

Sampling Instructions for Active Sampling

BURR KING FILTERPAK 4001 INSTRUCTION MANUAL BURR KING MFG. CO., INC

10331 Date Street Murrieta, CA SECTION HYBRID LAMINATE LOCKERS W/ PHENOLIC DOORS

Emission Line

Simalfa 335-Of {Overspray Free}

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

E Spray Drying. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN

POAI STREET, HSIN CHU, 300, TAIWAN Published online: 15 Feb 2007.

Analytical Methods For Diesel Particulate Matter(DPM)

Owner s Manual Calcite Cartridge System

94020 Conservation Vent (Pressure & Vacuum) Features

Technical Bulletin No. MK3176. PREPARED: July, 2010

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Chapter 10 Air Sampling and Analysis

droplet and volatilized occupational chemical exposure.

WH5-2 Iron & Hydrogen Sulfide Reduction Filter Package

BOLT MAINTENANCE GUIDE

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

FORMWORK 66 x 40 x 24 Lithic Freestanding or Alcove Box Bathtub Installation Guidelines. STYLE No. CAUTION: BATHTUB IS EXTREMELY HEAVY

Mar Cor Purification. Carbon Block Filtration System. Operation & Maintenance Manual

booster EX2 / EX3 Operating Manual Extrusion Welder Weldy AG Galileo-Strasse 10 CH-6056 Kaegiswil / Switzerland TECHSPANGROUP

PERISTALTIC PUMPS FOR USE IN THE FIELD

Transcription:

Operating Instructions 863 Valley View Road, Eighty Four, PA 15330 USA Tel: 724-941-9701 Fax: 724-941-1369 e-mail: skctech@skcinc.com SKC PMI Samplers The patented* SKC single-stage Personal Modular Impactors (PMIs) are designed for the highly efficient collection of PM10, PM2.5, or PM Coarse (10-2.5). The samplers are easy to use with a removable filter cassette and pre-oiled impaction disc. The 25-mm pre-oiled impaction disc mounts directly on top of the filter cassette and reduces particle bounce for high collection efficiency. A 25-mm filter may be used as an alternate impaction substrate for optional chemical analysis of particles. The PMI Coarse model includes a second filter cassette to allow collection of particles < 10 μm, but larger than 2.5 μm. Performance Profile Flow Rate: 3 L/min 50% Cut-point: 2.5 μm or 10 μm (model dependent) Impaction Substrate: Alternate Impaction Substrate: 25-mm pre-oiled disposable porous plastic disc; reduces particle bounce 25-mm filter material may be used for optional chemical analysis of larger particles Final Collection Filter: 37-mm filter, select material based on application Analysis: Gravimetric and chemical Impactor Material: Inlet: Aluminum Exhaust: PVC Filter Cassette: Delrin with stainless steel support screen O-rings: Inlet - PTFE Exhaust - BUNA-N Dimensions: 2 in x 1 in (5.1 x 2.6 cm) Weight: 2.5 oz (70.9 gm) Tubing: 1/4-inch ID * U.S. Patent No. 7,334,453

Principle of Operation PM10 Inlet PTFE O-ring 25-mm Impaction Substrate Filter Cassette Top Filter Cassette Bottom BUNA-N O-ring Inlet PTFE O-ring 25-mm Impaction Substrate Filter Cassette Top 37-mm Final Collection Filter Support Screen Filter Cassette Bottom BUNA-N O-ring PM2.5 Inlet (Coarse ring) PTFE O-ring Filter Retainer 25-mm Filter in impaction substrate position Filter Cassette Top 37-mm Final Collection Filter Support Screen Filter Cassette Bottom BUNA-N O-ring Exhaust Exhaust Figure 1. PMI 2.5 exploded Figure 2. PMI Coarse exploded Inertial impaction is employed to separate airborne particles according to their aerodynamic diameter. A sample pump draws particle-laden air at a flow rate of 3 L/min through an inertial impactor to separate airborne particles according to their aerodynamic diameter. Particles enter the impactor through nozzles on top of the sampler. The nozzles are sized to operate at a 3 L/min flow rate causing airjets to impinge onto the impaction substrate positioned below the inlet nozzles. Particles larger than the sampler cut-point with enough inertia to cross the airstream lines impact on the impaction substrate. The airflow, containing smaller particles, makes a sharp turn, passes through the openings in the top of the filter cassette, and follows through to a 37-mm final collection filter inside a filter cassette where the smaller particles collect. The top of the filter cassette accommodates the impaction substrate. For optimum impactor performance, a 25-mm oiled porous plastic disc is recommended as disposable impaction substrate. Alternatively, if chemical analysis of the particles is desired, a 25-mm filter may be used. To sample PM Coarse (PM10-2.5), a Coarse Ring accessory can be added to a PMI 10 Sampler or a PMI Coarse Sampler may be selected (see Ordering Information). Additional impaction and collection media are required for PM Coarse sampling. 2

Media Preparation Final Collection Filter: Equilibrate and pre-weigh filters in a clean environment according to appropriate procedures. Record the weight as the pre-sample weight. Impaction Substrate: Ready-to-use pre-oiled disposable plastic impaction discs are available as SKC Cat. Nos. 225-355 (qty. 25) and 225-355A (qty. 50). Using an oiled impaction disc reduces particle bounce. Alternate Impaction Substrate: 25-mm filters may be used if analysis of larger particles is desired. Impactor Preparation Cleaning For optimum performance, the PMI Sampler should be cleaned after five runs or upon a noticeable buildup of material to remove oil buildup on the top of the filter cassette and other residue built up from frequent sampling. Disassemble the impactor and wash parts in water with a liquid detergent or soap. Rinse and air-dry all parts thoroughly in a clean environment. Caution: Do not place any mechanical object in the inlet nozzles. O-ring Care Visually inspect the condition of BUNA-N O-rings (see illustrations on page 2 for location of O-rings). Ensure the O-ring surface is smooth (i.e., without cracks, cuts, or other damage). Ensure the O-ring is fitted properly in its channel. Replace the BUNA-N O-ring if there is apparent damage, stretching, or thinning. The PTFE O-rings are not user-replaceable. 3

Inserting a Final Collection Filter into the PMI Sampler The PMI Sampler will arrive already assembled. Disassemble it to insert a final collection filter. 1 2 Unscrew inlet from exhaust. Remove filter cassette. 3 4 Use the cassette opener accessory to open filter cassette. Ensure the stainless steel support screen is in place in the bottom of filter cassette. 5 6 Using the forceps accessory, place a preweighed 37-mm filter on the support screen. 7 Press filter cassette top into filter cassette bottom. When sampling for PM Coarse using the Coarse Ring accessory or PMI Coarse Sampler, no final collection filter is inserted in the first filter cassette. Insert a 37-mm final collection filter into the second filter cassette. Proceed to Inserting Impaction Substrate into the PMI Sampler. Reinsert cassette into impactor. Technical Tidbit: Use the forceps accessory to carefully insert or remove the collection filter. See Accessories for forceps. 4

Inserting Impaction Substrate into the PMI Sampler For PM2.5 or PM10 sampling, insert an impaction substrate only after a final collection filter has been loaded into the filter cassette. For PM2.5 or PM10, ensure a final collection filter has been loaded into the filter cassette (see Inserting a Collection Filter). 1 2 Place impaction disc or filter on top of filter cassette. The rough side of the impaction substrate should face up. 3 Screw impactor inlet and exhaust together just until tight and then further handtighten by 1/4-turn only. Keep sampler upright until the inlet is securely screwed onto the exhaust to prevent the impaction substrate from being dislodged. When sampling for PM Coarse using the Coarse Ring accessory or PMI Coarse Sampler, insert an impaction disc onto the first filter cassette as directed in Step 2. Insert a 25-mm filter in the impaction substrate position on the second filter cassette. Secure with filter retainer (supplied with the Coarse Ring or the PMI Coarse Sampler). Place the filter cassette, Coarse Ring, and second filter cassette assembly on the exhaust and screw impactor inlet and exhaust together just until tight. Further, hand-tighten by 1/4 turn only. Technical Tidbit: SKC recommends using a new impaction substrate for each sample period. 5

Calibration and Sampling Note: As the particle load on the final filter increases during sampling, the pressure drop will also increase. Therefore, use a compensating sample pump such as the AirChek XR5000. Calibration Calibrate pump flow rate with the PMI Sampler (loaded with final filter and impaction substrate) in line. See pump and calibrator operating instructions. 1. Ensure impactor is loaded and fully assembled (see Inserting a Final Collection Filter into the PMI Sampler and Inserting Impaction Substrate into the PMI Sampler). 2. Align calibration adapter with PMI inlet and press down until a firm seal is established. 1 3. Ensure pump has run for five minutes before calibrating. Using flexible tubing, connect the calibrator outlet (suction port) to the PMI calibration adapter inlet. 2 4. Using a second length of tubing, connect the PMI exhaust to the inlet of a sample pump. 3 & 4 5. Calibrate the sample pump to the specified flow rate. See sample pump and calibrator operating instructions. 6. When calibration is completed, remove the calibrator, tubing, and calibration adapter. 6

Sampling 1. If required, replace representative sample media used for calibration with new, pre-weighed media (see Media Preparation). 2. Use a length of Tygon tubing to connect the PMI exhaust to the pump inlet. 3. Use the clip to attach the PMI Sampler to a worker's collar in the breathing zone. 4. Turn on pump and record sample start time and other pertinent data. 5. After the desired sample time has elapsed, turn off the pump and record sample stop time and other pertinent data. 6. Reinstate calibration train and verify flow rate (see Calibration). 7. Remove pump and tubing from the impactor. 7

Sample Removal, Shipping, and Analysis Removing the Final Collection Filter and Impaction Substrate 1 Unscrew impactor inlet from exhaust. 2 Locate recessed area on filter cassette top and remove impaction substrate. If chemical analysis of larger particles is desired, place in appropriate container for shipping to a laboratory for analysis (see Accessories for Filter-Keeper). 3 Gently lift filter cassette from exhaust. 4 Use the cassette opener accessory to separate the two halves. 5 Use the forceps accessory to remove the final collection filter and place it in an appropriate container for shipping to a laboratory. Shipping Samples Package and transport samples and blanks in a manner that will prevent sample loss and contamination. See Accessories for the Filter-Keeper for transporting samples. Analysis Gravimetric and/or chemical by an accredited laboratory When sampling for PM Coarse using the Coarse Ring accessory or PMI Coarse Sampler, follow the instructions in Steps 1 through 5 for the second filter cassette only. Remove the two filters (one 25-mm filter for PM10 and one 37-mm final filter for PM2.5) from the second filter cassette, insert in separate containers, and ship to a laboratory for analysis. The impaction disc from the first filter cassette may be shipped to a laboratory for analysis if desired. 8

Ordering Information Description Cat. No. Personal Modular Impactor (PMI) includes impactor and filter cassette with support screen, requires impaction substrate and collection media sold separately; see below PM2.5 (gold) 225-352 PM10 (silver) 225-350 PM Coarse includes 2 filter cassettes and a filter retainer 225-351 Recommended Collection Filters Quartz Filters, 37 mm, Tissuquartz, 432 μm thick, pk/25 225-1822 PTFE Filters, 37 mm, 2.0-μm pore size, PTFE with PMP support ring, pk/50 225-1709 PTFE Filters, 37 mm, 1.0-μm pore size, PTFE with laminated PTFE support, pk/50 225-2705 Recommended Impaction Substrate, required for sampling. Limited shelf-life Pre-oiled Porous Plastic Impaction Discs, 25 mm, ready to use, disposable pk/25 pk/50 225-355 225-355A Accessories PM Coarse Ring includes filter cassette and filter retainer, adapts a PMI 10 to a PMI Coarse 225-3512 PMI Cassette Opener 225-357 Filter-Keepers, 37 mm, for filter transport pk/100 pk/10 225-8303 225-8303A PMI Calibration Adapter 225-358 Forceps, stainless steel, non-serrated flat tips, for delicate membranes 225-8371 Filter Retainer, secures filter in impaction substrate position on top of cassette 225-354 Replacement Parts Replacement Filter Cassette 225-356 Replacement Exhaust O-ring, BUNA-N P32001 Back pressure on PTFE filters can vary within the same lot. A 25-mm filter may be used as an alternative impaction substrate for optional chemical analysis. References Haynes, E.N., et al., Assessment of personal exposure to manganese in children living near a ferromanganese refi nery, Science of the Total Environment, Vol. 427-428, 2012, pp. 19-25 Wang, Z., et al., Evaluation of Real-time Instruments Used to Monitor PM in a Green Building, American Association for Aerosol Research (AAAR) Annual Conference Abstracts, Session 3AE.3, 2012 SKC Limited Warranty and Return Policy SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC s sole liability and the buyer s exclusive remedy. To view the complete SKC Limited Warranty and Return Policy, go to http://www.skcinc.com/warranty.asp. 9

10

11

www.skcinc.com 12 Form 37086 Rev 1405