Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel

Similar documents
FULL-RING EXPERIMENTAL STUDY OF THE LINING STRUCTURE OF SHANGHAI CHANGJIANG TUNNEL

CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN CONNECTIONS

Study on effect of segments erection tolerance and wedge-shaped segment on segment ring in shield tunnel

Foundation pit support and construction of Luneng Real Estate S-20 commercial building

The New Incremental Launching Construction Technology of Jiubao Bridge Long-span Hybrid Arch-girder Structure

STRENGTH CONSEQUENCE MINIMIZATION OF DIGGING OFF BURIED GAS PIPELINE AT ISOLATION COAT RENOVATION REALIZED DURING OPERATION

BEHAVIOR OF STEEL FRAMES WITH AND WITHOUT AAC INFILLED WALLS SUBJECTED TO STATIC AND CYCLIC HORIZONTAL LOADS

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

Rapid Development and Application of Prototype Test System of Prefabricated Metro Station Structure Joint

International Journal of Advance Engineering and Research Development

Load Bearing and Deformation Capacity of Fire Resistance Steel Tubular Columns at Elevated Temperature

In-plane testing of precast concrete wall panels with grouted sleeve

Behavior of Steel Beam to Concrete Filled Tubular Steel Joints after Exposure to Fire

Underground Construction Technology

Experimental study on seismic behavior of composite concrete and

Experimental study on bending behavior of prefabricated dry connection wall

The Open Civil Engineering Journal

Jinfeng Zhang 1, Wangsheng Liu 1, Ming Zhao 1 1. College of Civil Engineering, Tongji University, Shanghai , China.

3 Dimensional Structural Modelling of Segmental Tunnel Lining Using Finite Element Software

THE EXPERIMENTAL STUDY ON INNER SHIFT LINING STRUCTURE OF FREEZING SHAFT IN DEEP THICK AQUIFEROUS SOFT ROCK**

NUMERICAL SIMULATION ON LOCAL BOND-SLIP BETWEEN STEEL AND CONCRETE WITH EXPERIMENTAL VERIFICATION

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF INTERIOR JOINTS OF PRECAST PRESTRESSED CONCRETE FRAMES

ERECTION ANALYSIS OF THE CFST ARCH BRIDGE BY VERTICAL SWING METHOD OVER THE JING-HANG CANAL IN XUZHOU, CHINA

Development of Composite Concrete-Packed Steel Segment

TEST STUDY ON BASIC STATIC CHARACTERISTICS OF CABLE SUPPORTED BARREL VAULT STRUCTURE

Load Transferring Mechanism and Design Method of Effective Detailings for Steel Tube-Core Concrete Interaction in CFT Columns with Large-Section

THE EFFECT OF AXIAL COMPRESSION RATIO ON SEISMIC BEHAVIOR OF INFILLED REINFORCED CONCRETE FRAMES WITH PROFILED STEEL SHEET BRACING

Experiment and Finite-element-method Analysis of Steel Frame Joints Transferring Forces Outside Box Columns

Structural behaviour and failure mechanisms of concrete monoblock railway sleepers

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

Compression Test for Precast Encased Composite Columns with Corrugated Steel Tube

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

STRESS-RIBBON BRIDGES STIFFENED BY ARCHES OR CABLES

The Influence of Joint Details and Axial Force Ratios on Failure Mechanisms of SCFT Column-beam Connections

SEISMIC-FORCE-RESISTING MECHANISMS OF MULTI-STORY STRUCTURAL WALLS SUPPORTED ON PILES ABSTRACT

Analysis on Static Performance of KT Type Circular Steel Pipe s Tubular Joint

Joint Design of Precast Concrete Moment Frame using Hollow Precast Concrete Column Soo-Yeon Seo, Tae-Wan Kim, Jong-Wook Lim, Jae-Yup Kim

Anti-fatigue Performance Analysis on Steel Crane Beam

Presentation in support of

Creep and Shrinkage Analysis of Composite Truss Bridge with Double Decks

AXIAL AND FLEXURAL PERFORMANCE OF CONCRETE PILES PRESTRESSED WITH CFRP TENDONS

SEISMIC BEHAVIOR OF STEEL PLATE REINFORCED CONCRETE SHEAR WALLS

FRP FOR SUSTAINABLE PRECAST CONCRETE STRUCTURES

Design and Model Test of Shaft Lining Compressible Connector in Deep Hydrophobic Alluvium*

ANALYSIS AND ASSESSMENT OF ARTICULATED SKEW HOLLOW SLAB BEAM BRIDGE

The Earthquake Actions and Testing Approaches for Curtain Wall

EXPERIMENTAL STUDY AND ACTUAL STRUCTURE DESIGNING OF LOOP JOINT USED FOR SEGMENTED PRECAST CONCRETE BRIDGE PIER AND CAISSON.

Analysis and experimental studies of building glass facade

STUDY ON THE TUNNEL SECONDARY LINING CONCRETE CRACKING PERFORMANCE DURING SERVICE PERIOD OF WU- GUANG PASSENGER DEDICATED LINE

Behaviour of deviated CFRP-Strips

Code No: R Set No. 1

ANALYSIS OF INFLUENCING FACTORS ON COMPOSITE ACTION FOR REINFORCED GROUTED CONCRETE BLOCK WALL-BEAM

Fire Resistance of Composite Beams Composed of Rolled Steel Profile Concreted Between Flanges

Vierendeel Steel Truss / Composite Skin Hull Test

ABSTRACT. KEY WORDS: Tubular piles; composite behavior; offshore structures; push-out strength; bond strength; slip.

Office Building-G. Thesis Proposal. Carl Hubben. Structural Option. Advisor: Dr. Ali Memari

EFFICIENCY OF MICROPILE FOR SEISMIC RETROFIT OF FOUNDATION SYSTEM

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

The construction technology of Chongqing Chaotianmen Bridge

Title. Issue Date Doc URL. Type. Note. File Information UNDER CONTROLLED SHEAR AND AXIAL FORCES.

Integrated Optimal Life Cycle Design of Super Tall Buildings with Viscous Dampers

THE BENDING BEHAVIOR OF COMPOSITE TIMBER-STEEL BEAMS

Nonlinear Finite Element Analysis of the Steel-concrete Composite Beam to Concrete-filled Steel Tubular Column Joints

Florida Method of Test for NONREPETITIVE STATIC PLATE LOAD TEST OF SOILS AND FLEXIBLE PAVEMENT COMPONENTS

FAILURE MODE CLASSIFICATION OF REINFORCED CONCRETE COLUMNS BY THE ANALYSIS OF THE STRAIN DISTRIBUTION IN THE MAIN REINFORCEMENT

INFLUENCE OF PRSTRESS LEVEL ON SHEAR BEHAVIOR OF SEGMENTAL CONCRETE BEAMS WITH EXTERNAL TENDONS

Stability Analysis of the Thin Concrete Walls of the Hangzhou Grand Theater

Research on the Seismic Performance of an Externally Prestressed Rocking Reinforced Concrete Frame

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Precast concrete L-shaped spandrel beams are commonly

Standard Specification for concrete structures-2002, Seismic Performance Verification

9.6 Circular Prestressing

Numerical and Experimental Behaviour of Moment Resisting Connections using Blind Bolts within CFSHS columns

Ductile Fiber Reinforced Panels for Seismic Retrofit

Analysis of Buried Arch Structures; Performance Versus Prediction

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

STRENGTH AND DUCTILITY OF RETROFITTED R/C BUILDING BY MULTI-STORY STEEL-BRACED FRAME SUBJECTED TO TRI-LATERAL EARTHQUAKE LOADING

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

High Performance and Efficiency of Joints in Precast Members

REAL SCALE EXPERIMENTAL ANALYSES OF CIRCULAR HOLLOW SECTION MULTI-PLANAR STEEL TRUSSES

Basic Study on Reinforced Concrete Shear Walls Without Boundary Columns Retrofitted by Carbon Fiber Sheets

Development of the effective segmental tunnel lining with flexible elements

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

UNIT-1 RETAINING WALLS

Research on the Economy of Assembled Steel Structure Building Jian-feng LI, Qi-hui ZHAO and Lu-lu HAO

STRUCTURAL PERFORMANCE OF MIXED MEMBER COMPOSED OF STEEL REINFORCED CONCRETE AND REINFORCED CONCRETE

5.4 Analysis for Torsion

Introduction. 1. Outline of fan case ring

Title. Author(s)KIM, D. W.; SHIM, C. S. Issue Date Doc URL. Type. Note. File Information

Case Study: Challenges of a Single-layer Reticulated Dome

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Spatial analysis of concrete filled steel tubular tied arch bridge

REVIEW ON SHEAR SLIP OF SHEAR KEYS IN BRIDGES

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE)

Installation Guidelines for Flygt Pumps Pump Anchoring Recommendations

Circular tanks on two-parameter Wlasow s elastic subsoil

SHEAR STRENGTHENING OF RC BRIDGE PIERS BY STEEL JACKETING WITH EXPANSIVE CEMENT MORTAR AS ADHESIVE

Transcription:

Aug. 2011, Volume 5, No. 8 (Serial No. 45), pp. 732-739 Journal of Civil Engineering and Architecture, ISSN 1934-7359, USA D DAVID PUBLISHING Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel Liang Lu, Xilin Lu and Peifang Fan Research Institute of Structural Engineering and Disaster Reduction, Tongji University, Shanghai 92, China Abstract: Shanghai Changjiang Tunnel, 15 m in diameter, is one of the world s largest shield-driven tunnels in diameter. Tongji University has recently carried out a test on the full-scale three-ring lining structure of Changjiang Tunnel. This paper introduces the testing processes, including loading apparatuses, test contents, test cases, etc., and makes comparison with other shield lining structure tests conducted before, and finally gives some evaluations on the design of the tunnel. Key words: Shield-driven tunnel, lining structure, full-scale test, load apparatus. 1. Introduction Shield driven tunnel construction has played an important role in tunnel construction since its debut 100 years ago. It experienced great development in recent years with the appearance of various cross-section shield machines, and the shield diameter becomes increasingly larger. The design of the lining segments has close connection with the structure safety, construction quality, engineering investment, etc.. Therefore full-scale or other appropriate scale tests are often conducted before the construction of large tunnels, so as to verify the rationality and feasibility of the design, to control the construction quality, to make proposal of optimization, and thus to get better techniques and greater benefits. The experimental study of tunnel lining structures has been conducted many times in China and other countries. In 1999, Tongji University and Shanghai Tunnel Engineering & Rail Transit Design and Research Institute (STEDI) carried out a joint test of full-scale single-circular tunnel lining structures. The lining rings tested were of two kinds: one in Shanghai subway tunnel and the other in Guangzhou subway Corresponding author: Liang Lu, PhD, associate professor, research fields: earthquake engineering, numerical and experimental tests. E-mail: luloes@hotmail.com. tunnel. The lining ring of Shanghai subway tunnel had an outer diameter of 6.2 m, inner diameter of 5.5 m, wall thickness of 0.35 m, and ring width of 1.0 m, while the one of Guangzhou subway tunnel had an outer diameter of 6.0 m, inner diameter of 5.4 m, wall thickness of 0.30 m and ring width of 1.2 m. The test provided basis for optimizing the tunnel lining structure of Shanghai subway tunnel and perfecting its design and calculating methods by comparing the tests of the two rings, calculating and analyzing the internal force and deformation of the lining structure and overall evaluating the two rings deformation, internal force, anti-crack and water-proofing properties. The lining ring tested is a single one and shown in Fig. 1. The effects of adjacent lining rings and lengthwise pressure on the lining were not taken into consideration. Thirty-two hydraulic pressure jacks were employed to load along the radial direction inward to equally simulate the actual pressure on the lining. And the force was evenly acted onto the lining through pad beams. Shanghai Metro 8 is the first tunnel with double-circular lining in China [1]. For its successful completion, Tongji University carried out a horizontal 1:1 full-ring test in 2003 under three test cases, the lining ring strain, the strain of bolts ringwise and bolts lengthwise, the overall radial and tangential structure deformation, the opening of crack, etc., and

Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel 733 got practical result for the engineering. The test model was composed of three parts: the upper half ring, middle full ring and lower half ring, stagger-jointed with three rings. Fig. 2 shows the test and loading system. In Japan, the shield technique develops rapidly, and takes the lead in the world. In 2003, a full-scale structure test was carried out on double-circular rectangular shield lining, which brought forth a new cross-section of shield driven tunnels [2]. The lining was a double-circular rectangle, a composite lining structure with steel exterior and concrete interior. The loading test setup is shown in Fig. 3. The test models are of two kinds: one with central pillars and the other without. The models were loaded at 6 points, and they were stagger-jointed with three rings, considering the interaction between the rings. In another test of single- Fig. 3 Lining test of Kyoto municipal metro. circular lining, prestressed tendon were employed ringwise to compensate for the inadequate axial force resulted from concentrative loading of jacks, see Fig. 4 [3]. The fourth Elbe highway tunnel of Germany was the world s largest with its outer diameter of 13.75 m. Full-scale full-ring test was conducted to test the loading capacity and stability of the lining segments, see Fig. 5 [4]. The objectives of the test were: (1) to verify the loading capacity of the full lining ring; (2) to test the utmost deformation suffering of the lining ring; (3) to test the joint tolerance and allowance of the lining ring; (4) to test the sealing adaptability of segment joint to different displacement; and (5) to optimize the inner steel bars of the segments. Fig. 1 Loading test of single-circular lining. Fig. 2 Loading test of double-circular lining. Fig. 4 Test of single-circular lining with ringwise prestressed.

734 Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel Fig. 5 Test of the lining structure of 13.75-meter Elbe highway tunnel In the full scale full-ring lining test of Elbe highway tunnel, the tested lining was composed of one full ring and two half rings, with an outer diameter of 13.75 m, an inner diameter of 12.35 m, a thickness of 0.7 m, and a height of 4m. A friction-reducing bearing was fixed between the lining ring bottom and the floor of the lab to minimize the influence of bottom friction. A concentric ring with an inner diameter of 7 m, as a force reaction apparatus, was located at the middle of the lining ring, connected with the lining ring by 96 hollow jacks. In the test the jacks simulated the actual water and earth pressure on the lining segments by intensifying pressure on the lining ring through pull-rods. 150 displacement meters were installed on the surface of the lining ring to measure the deformation of the ring, and another 100 sensors to measure the opening and contracting degree of the segment joints. The testing process was controlled by a special test system. In the design of the tunnel lining structure of Green Heart, a tunnel in Holland, three-dimensional simulated analysis were made by the FEM codes of ANSYS and DIANA. For a further study, a full-scale test was conducted on the three-ring lining structure, see Fig. 6, and a comparative analysis was also brought out on the test result by FEM codes [5]. In addition, other tests, like the test of the lining-ring deformation, were also carried out. Fig. 6 Full-ring test of the lining structure of Holland s Green Heart tunnel. 2. The Objectives and Contents of the Test 2.1 Test Objectives The construction of Changjiang Tunnel is one of the greatest infrastructures in Shanghai and in China as well, with a design reference period of 100 years. The tunnel will be of the world s largest diameter, with an outer diameter of 15.0 m, an inner diameter of 13.7 m, lining ring width of 2.0 m, and it is to be shield-driven and stagger-jointed with popular wedgeshaped lining segments. To test the loading capacity and stability of the lining ring and to control the structure pressure and deformation under construction load, a full-scale full ring test of the lining will be necessary. The objectives of the test are: (1) To test the loading capacity of the lining rings under different design phases, including different burying depths and different side pressure coefficients; (2) To test the utmost deformation endurance of the lining ring; (3) To justify the calculated analysis parameters by comparing the test data with theoretical calculated results; (4) To get the stiffness variation limits of the joints ringwise and joints lengthwise and to get the largest opening angle, and also to verify the water-proofing and adaptability of the joints; and

Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel 735 (5) To test the safety and stability of the lining structure during operation stage. 2.2 Tunnel Lining Test Model The lining ring of Shanghai Changjiang Tunnel has an outer diameter of 15.0 m with the ring thickness of 0.65 m. The whole ring is composed of 10 segments, of which one is for enveloping, two for connecting, and the rest are standard. In the test, a 2-meter-wide middle full ring, a 1-meter-wide upper half ring and a 1-meter-wide lower half ring are employed. Ring segments are fastened as a whole by bolts ringwise, and rings are stagger-jointed and made a whole by lengthwise bolts, which makes a stagger-jointed shield-driven lining structure. According to the designed lining structure scheme, no more than three to five through-joints are allowed in the test model, and an axial force lengthwise is made to simulate the thrust force of the shield machine. The test model under assembling is shown in Fig. 7. to the future construction, the test was made more pertaining. According to the actual case, the covering earth depth of the lining ring was made 15 m and 27 m separately. Accordingly, six test cases were set up as shown in Fig. 8. In the test cases 1 to 3, equivalent concentrative force was exerted with a burying depth of 15 m and the side pressure coefficients of 0.68, 0.70, and 0.72 respectively, to find out the stress distribution, deformation and crack of the lining structure in this covering depth and to see the load endurance of bolts lengthwise between rings. 2.3 Test Cases and Design of Test Load The maximal burying depth of Changjiang Tunnel is 27 m. Since the results of the test could be of guidance Fig. 7 Test model under assembling. 0 F A A Upper Half Ring 1000 Pi/4 90 15000 270 Middle Full Ring Pi/4 Pi/4 Lower Half Ring 1000 Pi/4 650 180 A-A Fig. 8 Layout of horizontal equivalent load.

736 Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel In the test cases 4 to 6, equivalent concentrative force was exerted with a burying depth of 27m and the side pressure coefficients of 0.68, 0.70, 0.72 respectively, to find out the stress distribution, deformation and crack of the lining structure in this covering depth and to see the impact of staggered-joints on the structure. The concentrative force design was controlled by simulating the actual pressure and the internal forces of the key sections. In the test, the internal forces of the key sections was simulated by the radial force from 44 jacks distributed outside the lining ring to find out the loading capacity of the key sections and the optimization potential of the structure steel bars. The maximal horizontal thrust force of the jacks was about 2250 kn per point. Loading was fulfilled in 10 steps, and a set of intensified force was obtained in each step. When stable status of the structure was obtained, the test data were collected, and unloading was done likewise. To simulate the equivalent force of shield jack thrust in construction, 44 vertical jacks were placed around the whole ring exerting thrust force on the lining top and bottom. In cases with thin earth covering, the thrust force of the vertical jacks was 1500 kn per point, and in those with thick earth covering, the thrust force was 3000 kn per point. 2.4 Allocation of the Measure Points During the test, 346 strain gauges and 152 displacement meters were placed around the lining ring model to measure the physical variables, shown in Table 1. Besides, rectangular griddings were made both inside and outside of the model to observe and record the start and development of cracks in each load step. Table 1 Number of sensors used in the test. Physical variables Total of sensors Strain of steel bars Strain gauges Concrete strain Bolt strain Overall radial deformation of the lining ring Displacement meters Overall tangential deformation of the lining ring Stagger value at joints Open angle value at joints 280 40 26 16 16 40 80 3. Test Loading Apparatus Concentrative force on stagger-jointed lining structure included the thrust force of the shield machine as well as soil and water pressure, resistant force of stratum and overload of the ground. In testing, the test model, placed horizontally on the test platform, was thrust horizontally inward by 44 jacks around it to simulate the soil and water pressure, resistant force of stratum and overload from the ground. On top of the test model, 44 jacks were placed downward to simulate the thrust force of the shield machine. Fig. 8 shows the places where the horizontal equivalent forces were applied. The principle of loading design is that the actual load on the structure was replaced with the equivalent load produced by jacks, so as to ensure the internal force of key sections in the test model equals to that of the designed load. Based on this principle, horizontal and vertical loading apparatuses were designed and fulfilled. 3.1 Horizontal Loading Apparatuses According to the test objectives, horizontal equivalent loading was carried out under above six test cases, under which the testing model was loaded and unloaded with 44 jacks. The concentrative force from all loading points converged at the central steel reactive setup, constituting a self-balancing loading system. Each loading point was made up of force distributing beams and steel pull rods, and all the loading points were grouped into four:,,, and (see Fig. 8), which were equipped with 10, 12, 12, and 10 jacks respectively to find out the deformation, strength and anti-crack property of the staggered-joint lining ring.

Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel 737 The details are shown in Figs. 9~11. Concentrative force in each test case was gained gradually in 10 steps, and the maximal horizontal force exerted is shown in Table 2. Lining Ring 650 4000 Steel Reactive Setup 15000 Fig. 9 Plane of loading apparatus. Lining Segment 15000 13700 Vertical Loading Jack 4000 1000 1000 Steel Pull Rod Horizental Loading Jack Reactive Setup Steel Beam Fig. 10 Table 2 Trundling Bearing Seat Cross-section of loading apparatus. The maximum concentrative forces under each case (kn) remarks Case 1 1260 1156 1074 1148 Burying depth: 15m,side pressure coefficient: 0.72 Case 2 1260 1140 1060 1116 Burying depth: 15m,side pressure coefficient: 0.70 Case 3 1260 1124 1044 1084 Burying depth: 15m,side pressure coefficient: 0.68 Case 4 2240 1970 1846 1980 Burying depth: 27m,side pressure coefficient: 0.72 Case 5 2240 1960 1826 1940 Burying depth: 27m,side pressure coefficient: 0.70 Case 6 2240 1940 1806 1892 Burying depth: 27m,side pressure coefficient: 0.68

738 Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel 3.2 Vertical Loading Apparatuses There were 44 vertical loading points evenly distributed on top of the test model, see Figs. 10~11. Each point was in a self-balancing system, composed of upper and lower steel beams and four steel rods. Each vertical concentrative force was loaded twice with 1500 kn and 3000 kn to simulate the thrust force of the shield machine jacks under the test cases of thin earth covering and thick earth covering. The top of the test platform was covered with a thin steel plate of 2 mm, and 44 trundling bearing seats were fixed under the test model to reduce the force of friction between the model bottom and the top of platform and to keep free deformation of the lower part of the model. Each seat contains ten lubed steel balls, 100 mm in diameter. The balls and the seat are shown in Fig. 12. 4. The Process and Results of the Test In the test, cracks were observed and the following variables were obtained under different load steps: overall deformation of the structure, the strain of the reinforcing bar of segments, the strain of concrete and connecting bolts and the staggered value and open angle of joints in the connecting parts. The strain was measured with strain gauge, and the displacement was measured with displacement meter. Before the test, all loading devices and measuring meters were verified and calibrated. The resolving power of the loading devices was 0.1 kn and the tolerance of the loading devices was less than 0.3 kn. After analyzing the test data, the overall distribution of axial force and bending moment along the ring and the overall deformation were obtained in each case. Figs. 13-15 show the internal forces and deformation 0 o SCALE 0 4000kN 90 o 270 o test case 3 test case 6 Fig. 11 Overall view of tunnel lining model test. 180 o Fig. 13 Axial force distributions along the lining ring under maximum load. 0 o SCALE 0 4000kN-m 90 o 270 o test case 3 Fig. 12 Trundling supporting seat. 180 o test case 6 Fig. 14 Bending moment distributions along the lining ring under maximum load.

Full-Ring Experimental Study of the Lining Structure of Shanghai Changjiang Tunnel 739 0 o SCALE 0 10 20mm Research Institute, with whose corporation this test was carried out and the test planning was completed. References 90 o 270 o test case 3 test case 6 180 o Fig. 15 Overall deformation of test model under maximum load. of the middle full ring under maximum test concentrative load. The results of the test showed that the strain of the reinforcing bars, the strain of the connecting bolts and the staggered value and open angle of joints in connecting parts of the lining segment were all within the permissible design value. Acknowledgements The authors hereby extend their thanks to Shanghai Tunnel Engineering & Rail Transit Design and [1] L. Lu, X. L. Lu, P. F. Fan and Z. J. Guo, Experimental study of a double-circular shield tunnel lining, in: Proceeding of the First International Conference on Advances in Experimental Structural Engineering, Nagoya, Japan, July 18-22, 2005. [2] H. Nakamura, T. Kubota, M. Furukawa and T. Nakao, Unified construction of running track tunnel and crossover tunnel for subway by rectangular shape double track cross-section shield machine, Tunnelling and Underground Space Technology 18 (2003) 253-262. [3] K. Nishikawa, Development of a prestressed and precast concrete segmental lining, Tunnelling and Underground Space Technology 18 (2003) 243-251. [4] J. Schreyer and D. Winselmann, Suitability tests for the lining for the 4th elbe tunnel tube Results of large-scale Tests, Tunnel 1 () 34-44. [5] C. B. M. Blom, E. J. Horst and P. S. Jovanovic, Three-dimensional structural analyses of the shield-driven green heart tunnel of the high-speed line south, Tunnelling and Underground Space Technology 14 (1999) 217-224.