Ion Collector Kits for Manual Guns (Versa-Spray and Versa-Spray II)

Similar documents
Urethane Booster Pump Seal Kit (Zenith or Nordson -Type)

CENTRUM CUP STACKER OPERATIONAL INSTRUCTIONS

Standard and Low-Flow 100 PLUS Powder Feed Pumps

Application guidelines for metallic powder coatings

SERVICE PARTS LIST. SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS M18 1/4" Hex Impact Driver - Two Speed STARTING SERIAL NO.

CENTRUM CUP STACKER OPERATIONAL INSTRUCTIONS

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS. 120V Permanent Magnet Drill STARTING SERIAL NUMBER.

Multi-Piece Shower with Trench Drain

SERVICE PARTS LIST BULLETIN NO M18 FUEL 1-1/2" Magnetic Drill CATALOG NO. G96A

Construction Standard No: 8.3.3

AES ADHESIVE EQUIPMENT & SOLUTIONS Page 6

Straight Panel Bath Screen Instruction Manual

Multi-Piece Shower with Trench Drain

Multi-Piece Shower with Trench Drain

2017/ Rev-AA.0

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

Wall-Mount & Back to Wall Toilets

450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved)

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with UM50 modules.

GROUND MOUNT INSTALLATION MANUAL

OptiFlex 2. any powder any part any place. Your global partner for high quality powder coating. Manual powder coating

NH3 Sampling Protocol Using The Ogawa Sampler*

Cornerview Shower Enclosure & Base

V Series 20ft. Modular Wall Design 17

Quick-release pins swing the rack open from left to right to simplify installing and maintaining your equipment.

Inlet Duct System for a Cisco 6807 Part Number: DIRLC3210S17W

Fastening technology for metals and plastics

Praxair and TAFA 88T UltraMachinable Stainless Wire

CRITICAL MATERIALS HANDLING 150 MM WAFER SHIPPING AND HANDLING PRODUCTS

WALLPLATES. Screwless Wallplates. Plastic Wallplates M4-M9. Metal Wallplates M10-M14 M-1

Ultra Aluminum Fence, Rail & Gate Specifications

Oyster ph - Conductivity - TDS - Temperature Meters

Maelstrom. Installation and Specification Guide

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

2 Ohm Nominal Component Speaker System OWNER S MANUAL

PanelGrip Dry Glaze Glass Railing System

Outward Folding Bathscreen Instruction Manual

SYSTEM 25 SYSTEM 50 AL SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Aluminium. Product Information

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

SECTION ORNAMENTAL ALUMINUM FENCING

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS

Axiom. SURFACE MOUNTED ARRAY Patient Headwall. Installation Guidelines. Installation Instructions.

SPECIFICATIONS. Section Ornamental Fences and Gates

Circular Expansion Cement Curing Kit Instruction Manual

CAULKING INSTRUCTIONS GRABBERGARD EFC & IFC

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

Enduring Strength. Classic Beauty.

STP Mount Series. Installation Manual. STP-LSCR-MAN 2017 Edition v1.0. For models: STP-SCR/045 STP-SCR/060 STP-SCR/070 STP-LCR/090 STP-LCR/120

Solar Powered TS1000 Installation Pictures. (Trench and Fill Method) City of Vallejo, CA

LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition

INSTRUCTION MANUAL FOR WIRE WELDING MACHINE

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS. M18 FUEL 1-1/2" Linemen Magnetic Drill CATALOG NO. STARTING SERIAL NUMBER

CI/SfB (52.5) January 2004 Uniclass L L2123. ACO LightShaft Daylight and fresh air. Naturally.

SECTION ORNAMENTAL ALUMINUM RAILING

INSTALLATION MANUAL MOSER STAINLESS STEEL KITCHEN FAUCET MODEL MANCHESTER

Manual Powder Finishing. Efficient and economical Flexible and user friendly Ergonomic design. Industrial Solutions

CARE AND USE INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR YOUR TOYOTA TUNDRA DOUBLE CAB & CREWMAX FRONT FLOOR LINERS

Important Information

January 1, 2012 AVAILABILITY LIST

Residential Commercial Industrial

Quick Adjustable Height Stands

SECTION ORNAMENTAL WELDED STEEL FENCING

SYSTEM 600 GENERAL MAINTENANCE AND ADJUSTMENT GUIDE

assembly and installation guide

RPA Plate Lifting Inserts Technical Manual

Powder and Liquid Spray Application Solutions Extrusions

TRACE 1300 and TRACE 1310 Gas Chromatographs. NoVent Microfluidics. Installation Guide Revision A March 2013

W E I N S P I R E W O R K

HALLOWELL FORT KNOX Modular Utility Storage and Workbench System Specifications

Fortina Louvers > Wall > Direct Attachment > Interior/Exterior

Installation Instructions

DUBO retaining rings for socket head screws. DUBO toothed collar rings. KORREX protective caps for socket head screws. KORREX insulating bushes type I

Application Guide for Jotun Ultra One Powder Coatings for Engineered Wood

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section.

Power Distribution Module Replacement Instructions

1.0. Post Install Kit. For Use With All Vinyl Railing BOM V1 1/13. Owner's Manual. Assembly and Installation Instructions.

Benefits in Speed and Logistics using the RL System. snapnrack.com

SPECIFICATION OPTICAL TERMINATION BOX for FTTx

SECTION DECORATIVE METAL FENCES AND GATES

INSTALLATION INSTRUCTIONS

EVALUATION REPORT ON THE ANEST IWATA W 100 GRAVITY SPOT REPAIR AND PRESSURE FED SPRAY GUNS CONDUCTED BY THATCHAM TRAINING CENTRE

Rough-in frame and flush-mount panel installation instructions

LANAP300 Installation Instructions

AEROFOILS 200AF-450AF. Sun Control Systems

Vasario. Vasario Series. Build on a Solid Foundation. Standard Duty Cash Drawer Series

WARNING- THIS EQUIPMENT IS DESIGNED FOR ADULTS ONLY. ONLY HEALTHY PEOPLE AGES 13 AND UP SHOULD USE THE EQUIPMENT.

INSTALLATION INSTRUCTION (U.S.A) FOR LUMI-O DRY NICHE INGROUND LIGHT.

HOBART BROTHERS Metal core Process. Basics of Welding Metal Cored Wires

Flextray - Accessories

Model # 940SM-V8. Page 1 of 10

Material and Process. Specification

The advantages of resistance welding versus Mig welding are: Weld consistency Weld strength Floor cleanliness.

Model # BARK /26/2012 Page 1 of 5

HD Firewall Mount 850 all, S/V , C ipd #

Accessories / Screwlocks

AUTOMATIC AIR VALVES For potable water

INSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS

ACOUSTIC FENCING PANELS SPECIALLY DESIGNED TO REDUCE NOISE GENERATED BY ROAD AND RAIL TRAFFIC. membro de:

PILGRIM BSERVER SPACE STATION ASSEMBLY INSTRUCTIONS 1 MAIN THRUSTER BACK BONE-EXTENSION ROD NUCLEAR POWERED INTERPLANETARY SPACECRAFT.

Transcription:

Instruction Sheet P/N Ion Collector Kits for Manual Guns (Versa-Spray and Versa-Spray II) 1. Description This instruction sheet covers the ion collector kits for Versa-Spray and Versa-Spray II manual guns. One kit is for standard guns with or without nozzle extensions; the others are for guns with 150- and 300-mm lance extensions, with or without nozzle extensions. 189 492 Kit, manual gun, ion collector 189 493 Kit, 150-mm lance, ion collector 189 494 Kit, 300-mm lance, ion collector The ion collector can improve the smoothness and appearance of cured powder coatings. It collects ions emitted from the gun s charging electrode instead of allowing them to deposit on the part. This can reduce the rate of charge buildup in the powder deposited on the part, which may reduce defects in the cured coating such as pinholing and orange peel. The standard gun kit consists of a bracket, screws, and a 11-in. (279-mm) collector rod. The kits for the lance extensions add clips that attach to the extensions to support the longer rods required. The distance from the end of the rod to the end of the gun is adjusted by sliding the rod through the clips and bracket. The rod is electrically grounded through the gun cable and control unit. 1 3131B01A Fig. 1 Ion collector kit (installed on a Versa-Spray II manual gun with a nozzle extension) 1. Ion collector kit

2 Ion Collector Kits for Manual Guns 2. Installation 1. Perform step 1 under Adjusting Rod Length on the following page. 2. See Figure 2. Loosen the captive screws (1 and 9) from the handle cover and remove the handle cover (10). 3. Remove the O-ring (2) from the top captive screw (1). Remove the captive screw. 4. Reinstall the handle cover and tighten the two lower captive screws (9). 5. Install the ion collector bracket (8) on the gun with the pan-head screw (4) included in the kit. 6. If installing a kit for a gun with a lance extension, snap an extension bracket (7) onto the lance extension (6) as shown. Use one bracket for a 150-mm lance extension and two for a 300-mm extension. 7. Slip the rod (5) through the holes in the extension bracket(s) and the ion collector bracket. Install the socket-head cap screw (3) in the ion collector bracket. 1 2 3 4 5 8 9 6 10 7 Fig. 2 Installing the ion collector kit (Versa-Spray II gun with 150-mm lance extension shown) 1. Captive screw 2. O-ring 3. Socket-head cap screw 1 4. Pan-head screw 1 Note: 1 Kit components 5. Rod 1 6. Lance extension 7. Extension bracket 1 8. Ion collector bracket 1 9. Captive screws 10. Handle cover 3131B02A

Ion Collector Kits for Manual Guns 3 3. Adjusting Rod Length After the ion collector kit is installed, the distance from the end of the ion collector rod to the tip of the gun s charging electrode must be adjusted. If the end of the rod is too far away from the tip of the electrode, the ion collector will not collect any ions or improve the appearance of the cured coating. If the end of the rod is too close to the end of the gun, powder particles may not be charged efficiently and the powder transfer efficiency may be reduced. Finding the optimum location for the rod end requires some experimentation. 1. Before installing the ion collector kit on the gun, coat several parts. Note the current (µa) shown on the control unit display when coating the parts. Cure the coatings. 2. Install the ion collector kit on the gun as described previously. 3. Loosen the socket-head cap screw (3, Fig. 2) and slide the rod through the ion collector bracket until the end of the rod is far away from the front end of the gun. 4. While coating parts, slide the rod forward until the current shown on the control unit display is 5 to 7 µa higher than that displayed in step 1. 5. Cure the coating on the test parts. Compare the surface finish on these parts with the finish on the parts coated in step 1 (before the ion collector kit was installed). 6. If the desired improvement in the surface finish has not been obtained, loosen the socket-head cap screw and slide the rod forward approximately 1-in. Tighten the cap screw. 7. Repeat steps 5 and 6 until the desired improvement in surface finish is obtained.

4 Ion Collector Kits for Manual Guns 4. Parts Lists Standard Gun Kit See Figure 3. Item Part Description Quantity Note 189 492 Kit, manual gun, ion collector 1 1 189 482 Rod, ion collector, 11 in. 1 2 982 628 Screw, socket, M5 x 10, stainless steel 1 3 189 487 Bracket, manual gun, ion collector 1 4 982 069 Screw, pan head, M4 x 16 1 NS 982 278 Screw, set, cup, M5 x 8, black 1 A NOTE A: Optional, replaces item 2. NS: Not Shown 150-mm Lance Extension Kit See Figure 3. Item Part Description Quantity Note 189 493 Kit, 150-mm lance, ion collector 1 1 189 483 Rod, ion collector, 15 in. 1 2 982 628 Screw, socket, M5 x 10, stainless steel 1 3 189 487 Bracket, manual gun, ion collector 1 4 982 069 Screw, pan head, M4 x 16 1 5 189 485 Bracket, lance extension, ion collector 1 NS 982 278 Screw, set, cup, M5 x 8, black 1 A NOTE A: Optional, replaces item 2. NS: Not Shown 1995 Nordson Corporation

Ion Collector Kits for Manual Guns 5 300-mm Lance Extension Kit See Figure 3. Item Part Description Quantity Note 189 494 Kit, 300-mm lance, ion collector 1 1 189 484 Rod, ion collector, 21 in. 1 2 982 628 Screw, socket, M5 x 10, stainless steel 1 3 189 487 Bracket, manual gun, ion collector 1 4 982 069 Screw, pan head, M4 x 16 1 5 189 485 Bracket, lance extension, ion collector 2 NS 982 278 Screw, set, cup, M5 x 8, black 1 A NOTE A: Optional, replaces item 2. NS: Not Shown 2 3 5 1 4 3131A03A Fig. 3 Ion collector kits

6 Ion Collector Kits for Manual Guns Nordson, the Nordson logo, and Versa-Spray are registered trademarks of Nordson Corporation.