BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.

Similar documents
BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.

R E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E

Senturion TM I Wall System

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

Senturion TM III Wall System

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

WeatherSmart Air Barrier Installation Guide

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Magnum Board Coatings

Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)

Finestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

Acrocrete Platinum CI Stucco Ultra Typical details for a premium impact and puncture resistant rain screen design cement plaster stucco system

AquaFlash System Installation Guide DS196

The better way to build TM. Installation Manual NAILBASE PANELS

SC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

ReCote Finish System over Concrete

Aqua Coast Engineering

EIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate

2019 IAQA Annual Meeting

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Detail Booklet StoTherm ci XPS

GAF EnergyGuard Polyiso Wall Sheathing

BACKSTOP NT - Texture A high performance, non-cementitious water-resistive membrane and air barrier. Backstop NT - Texture Application Instructions

EXTERIOR INSULATION & FINISH SYSTEMS PRELIMINARY INFORMATION

Chapter 2 Understanding The Problem

DuPont Tyvek Wall Underlay Install Guide

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

FEDDERLITE PANEL SYSTEM Prefabricated, Lightweight, Outsulation Exterior Wall Panels with Integrated Reinforcing Channels

Accent is cracked with stains Accent is sloped away from the home Flat accent is not sealed to window

Finestone Stucco System

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

BACKSTOP TM NT - Texture A high performance, water-resistive membrane and air barrier

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

BACKSTOP NT - VB A high performance, non-cementitious water-resistive membrane and air/vapour barrier

FirstEnergy Program Overview

application instructions

Distances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

Sentry Stucco Ultra Wall System

Product and System Specifications DuPont Flashing Systems

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

BUILDING EXTERIOR SHELL TRAINING

Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS Application Instructions

Structalath Twin Trac 316 System Section Corporate P.O. Box 397 Fortson Georgia FAX Technical

Inspection Fundamentals: Stucco & EIFS

Moisture Survey Inspection Report

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

Siding and Soffit Installation Guidelines

Dow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green

PAREXEIFS EXTERIOR INSULATION AND FINISH SYSTEM

Primary Concerns and Defects

How do you install yours?

RESIDENTIAL INSULATED SHEATHING COMFORTBOARD. Installation Guide

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

FINESCREEN 500. Part 1 - General. Section Impact Resistant Cement Board Stucco Wall System 1.1 GENERAL REQUIREMENTS

Ultrakote Cementitious Finish System

Finestone Stucco Ultra Wall System

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

LP SmartSide Perfection Shingle

Ultra Wall System. CAD Detail Sets

MOISTUREFREE WARRANTY INSPECTION PROTOCOL

AquaFlash System Installation Guide

DIVISION 7 THERMAL AND MOISTURE PROTECTION

RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE. Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD 80

SECTION Exterior Insulation and Finish System WM Specification

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

SRP-AirOutshield UV Issued:

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Window Installation Instructions Series 1000 Steel Replica Window

PLYWOOD FLOATING FLOOR

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

ADDENDUM A CONSTRUCTION SPECIFICATIONS

Guide Specification for the OSI QUAD Window and Door Flashing System

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

Siding and Soffit Installation Guidelines

Light-Metal Roof Edge, Raised

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Roofing City of Owatonna BUILDING DEPARTMENT

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

PART 1 - GENERAL PROJECT NAME SECTION VAPOR PERMEABLE AIR BARRIER

Sto Guide Specification No. F601S StoQuik Gold Finish System for Soffits and Ceilings

Residential Building Inspections

Commercial Flashing Details

Transcription:

BUILDING SUCCESSFULLY WITH RESIDENTIAL S. DS504

THE FOLLOWING IS A LIST OF MAJOR CONSIDERATIONS THAT WILL HELP ENSURE A QUALITY INSTALLATION. SUBSTRATES (INSPECTION/WALK-AROUND) Prior to starting a job, it is important that the EIFS contractor and the builder or representative walk around the project to inspect and check the structure making sure the walls and corners are in plane and that the approved substrate and flashing is in good condition and properly installed per local building code requirements. TERMINATIONS/FOUNDATION Provide adequate clearance so that the Dryvit system can terminate a minimum of 203 mm (8") above grade or as required by local code. This is important to allow for proper inspection by pest control operators. All terminations require back wrapping unless Starter Track with weep holes is used. Back wrapping is defined as the continuation of the reinforced base coat across the face and edge of the insulation board. The reinforcing mesh is continued onto the back side of the insulation board a minimum of 64 mm (2-1/2").

EXPANSION JOINTS Dissimilar Materials When the system terminates against a dissimilar material, such as wood or concrete, the system shall be held back a minimum of 19 mm (3/4") to allow for an expansion joint and caulking. Floor Lines In wood-framed construction, expansion joints are installed at each floor line to allow for framing shrinkage. Minimum of 19 mm (3/4") recommended. Other Expansion joints should be included at areas where there is a change in substrate that could result in differential movement, at areas with significant movement, as expansion joints in the substrate or building, or where the design professional requires. Minimum of 19 mm (3/4") recommended. PENETRATIONS Terminations at penetrations, such as windows, doors, light fixtures, hose bibs, dryer vents, wall receptacles, etc. require back wrapping with reinforcing mesh and base coat. The insulation board must be held back from the opening a minimum of 12.7 mm (1/2") for proper sealant installation. A fillet bead of sealant is permitted around small penetrations such as hose bibs, etc.

DECK Deck flashing should be installed to preclude water entry. In addition, flash the top edge of the Dryvit system if it is cut to accommodate the header joist. Use good construction practices for flashing and sealant installation to ensure watertightness. Dryvit details are for general information and guidance only. WINDOW Not all windows are created equal. It is important to use good quality codecompliant windows. Windows can be a significant contributor to water intrusion. Windows should be flashed and caulked per window manufacturers recommendations to prevent water entry. ROOF INTERSECTING VERTICAL WALL A kickout or diverter flashing must be installed as the first piece of flashing at the end of the roof where it intersects the wall. All diverter joints must be soldered. Step flashing is to extend up the wall at least 152 mm (6"). The purpose of the flashing and diverter is to shed the water off the roof and keep it out of the vertical wall beneath.

SOFFIT RETURNS/GABLE ENDS When frieze boards are to be installed, install the Dryvit system first; the frieze boards are installed over the Dryvit system and sealed as required. CRICKETS/CHIMNEY ENCLOSURE Crickets are designed to deter the accumulation of snow and ice and deflect water around a chimney. To finish masonry enclosures, it is recommended that a skim coat of base coat be applied prior to application of finish. Use of insulation is not recommended due to possible heat buildup. The wood-enclosed chimney chase can be finished with a full Dryvit system with EPS insulation. Flashing should continue vertically 152 mm (6") above the cricket. Flashing at the top of the enclosure must also be installed.

SEALANTS Expansion joints and terminations at windows and other openings must be properly sealed. Use closed-cell backer rod and sealant primer. Consult the following manufacturers to verify that they have tested their sealants for compatibility with EIFS: Pecora Corporation Sealant: Dynatrol ll Primer: Type 75 or 150* Pecora Corporation Sealant: 890 Silicone Primer: P64* Sika Corporation Sealant: Sikaflex 2C Primer: Sikaflex 429* Dow Corning Sealant: Dow Corning 790, 791**, 795** Primer: Dow Corning 1200* Prime Coat Tremco, Inc. Sealant: Spectrem 1, 3 and 4 Primer: TREMprime Silicone Porous Primer* *Primer is for sealing Dryvit to Dryvit. For sealing Dryvit to other materials, consult with sealant manufacturer. **Dow Corning 791 and 795 are intended to be used as perimeter seals and at penetrations. They are not intended to be used when sealing Dryvit to Dryvit.

AVOIDING WATER Water intrusion into the exterior wall of any structure can lead to problems; therefore, attention must be paid to following proper details to minimize the risks. Traditional EIFS are barrier-wall systems designed to keep water out of the structure just like other components that make up the exterior envelope. Dryvit offers an EIFS design that incorporates a waterresistive barrier and a drainage plane. Incidental moisture that may enter around the system reaching the water-resistive barrier harmlessly drains out of the wall. However, the critical step with all exterior siding in eliminating potential moisture problems is planning for and executing properly the interfacing of the Dryvit system with all other adjacent building components. It is important that the builder, EIFS contractor, roofer and framer together review all construction details and documents that relate to the interfacing of the different exterior systems and components that make up the envelope of the house before starting construction. Dryvit strongly urges EIFS contractors not to begin work on a project in which the construction requirements for EIFS application have not been fulfilled. See next page.

WE AT ASK OUR EIFS CONTRACTORS TO INSIST ON THE FOLLOWING BEFORE STARTING AN EIFS INSTALLATION. Water-resistive Barrier A code-approved water-resistive barrier shall be installed horizontally overlapping the course below in a weatherboard fashion. The minimum overlap is dictated by the applicable building code. Ambient Temperature Requirements A minimum temperature of 4 C (40 F) and rising during installation and 24 hours thereafter shall be maintained. Substrates Wall sheathing shall be securely fastened per applicable building code. There shall be no planar irregularities greater than 6.4 mm (1/4 in.) within any 1.2 m (4 ft.) radius. Flashing at Openings All openings shall be properly flashed per project design documents. Individual windows, that are ganged to make multiple units, shall have continuous flashing and/or joints between them and shall be fully sealed. Decks Provisions shall be made to ensure that the Dryvit system can be properly terminated above grade and at patios, decks, landings, etc. and that the required flashing is in place. Roof Ensure that the roof has positive drainage, i.e., crickets or saddles. Metal roof flashing shall be installed in accordance with the guidelines set by the Asphalt Roofing Manufacturers Association (ARMA). Run-off diverters, i.e., kickouts, must be installed where required. Utilities Provisions must be made to ensure that the system terminates properly at lighting fixtures, electrical outlets, hose bibs, dryer vents, etc.

THE BUILDER SERIES: NINE CRITICAL AREAS THAT DESERVE A CLOSER LOOK The following pages contain nine advertisements that have appeared in BUILDER magazine as part of an educational campaign by Dryvit. Each of these ads focuses on a specific aspect of construction in which good planning and coordination between trades is important to a quality building envelope. Detailed drawings show how to ensure a quality job. Other alternatives, generated by design professionals, may be appropriate. Dryvit publishes comprehensive specifications, application instructions and details. This guide is not to be used in lieu of the more comprehensive information. Copies of those documents are available free of charge by calling 1-800-556-7752 or by visiting our web site at www.dryvit.com. Technical Service representatives can also answer any questions concerning the application and details of the Dryvit products.

WHERE ROOF AND VERTICAL WALL MEET SHEATHING AS SPECIFIED DIVERTER INSTALLS HERE DRIP EDGE FASCIA HOLD A MIN. OF 2" FROM ROOF Building Successfully With Dryvit Residential Systems CAULK Details Are The Key To Success FIG. 2 FIG. 1 ROOFING FELT Fig. 1) A diverter flashing is installed as the first piece of flashing at the end of the roof where it intersects the wall. Fig. 2) This detail shows the installation of the diverter and step flashing. The purpose of the step flashing and diverter is to shed the water off the roof and keep it away from the vertical wall beneath. Note: All diverter joints must be soldered. Fig. 3) The Dryvit system is held a minimum of 2" off the roof and caulked around the diverter. PLACED OVER STEP FIG. 3 STEP EXTENDS UP AT LEAST 6" ROOF SHINGLES PRIDE #1 in a Series SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

Building Successfully With Dryvit Residential Systems #2 in a Series TERMINATIONS ABOVE GRADE INSULATION BOARD WATER- RESISTIVE REINFORCING MESH STAPLED OVER BOTTOM EDGE OF IS LEFT FREE TO DRAIN GRADE PRIDE Details Are The Key To Success FIG. 1 DETAIL REINFORCING MESH EMBEDDED IN BASE COAT REINFORCING MESH STAPLED OVER Fig. 1) This detail shows proper back wrapping which shall be done at all terminations. The Detail Mesh underlaps the reinforcing mesh on the face of the wall by a minimum of 2 1 2". Fig. 2) The Dryvit system is terminated a minimum of 8" above finished grade or as required by local code. REINFORCING MESH (AS SPECIFIED) EMBEDDED IN BASE COAT FIG. 2 FINISH HOLD A MIN. OF 8" FROM GRADE OR AS REQUIRED BY LOCAL CODE. GRADE SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

Building Successfully With Dryvit Residential Systems FIG. 2 AT CHIMNEY AND CRICKET FIG. 1 PREFABRICATED CHIMNEY CAULK WATER- RESISTIVE HOLD A MIN. OF 2" UP FROM ROOF STEP MASONRY CHIMNEY CAULK FINISH SKIMMED BASE COAT DO NOT EXTEND BASE COAT AND FINISH OVER COUNTER Details Are The Key To Success CORNER LAPS STEP TERMINAL RAIN CAP EXTERIOR GRADE PLYWOOD STEP EXTENDS UP AT LEAST 6" NAIL TO DECK CRICKET CUT TO FIT OVER CRICKET AND EXTEND OVER ROOF AT LEAST 6" PREFABRICATED METAL CAP MASONRY CHIMNEY Fig. 1) This detail shows chimney with plywood and all associated roof flashing finished with Dryvit system held up a minimum of 2" from roof. Fig. 2) This detail shows a masonry chimney with associated roof flashing, counter flashing and cap. Shown with skimmed Dryvit base coat and Dryvit finish. Note: Use of EPS insulation is not recommended on masonry chimneys. PRIDE COUNTER TIED INTO MASONRY CRICKET AS PER FIG. 1 STEP EXTENDS UP AT LEAST 6" UNDER COUNTER #3 in a Series SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

FIG. 1 Building Successfully With Dryvit Residential Systems WHERE DECK AND VERTICAL WALL MEET 2" MIN. FIG. 2 2" MIN. FILLET CAULK WITH BOND BREAKER TAPE BACK WRAP Details Are The Key To Success CAULK 2" FASTEN HEADER JOIST THROUGH TO HOUSE FRAMING 2" NAILER AS REQUIRED SLOPE DOWNWARD TO DRAIN Fig. 1) Hold Dryvit system a minimum of 2" up from decking. Extend flashing 2" behind system. Decking should be fastened so as not to penetrate flashing. Fig. 2) Hold Dryvit system back a minimum of 2" from deck end joist to allow for proper caulking. System terminations below deck shall be encapsulated with reinforcing mesh, base coat and finish. PRIDE #4 in a Series SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

Building Successfully With Dryvit Residential Systems AT DORMER OVERLAPS SHINGLES ON MAIN ROOF TO TOP OF CUTOUTS STEP FIG. 3 HOLD A MIN. OF 2" UP FROM ROOF ROOF SHINGLES Details Are The Key To Success DORMER TO ROOF FIG. 1 Fig. 1) Install dormer step and valley flashing and dormer to roof flashing. Where window is close to roof line, continue flashing into opening. Fig. 2) Wrap the rough opening with membrane flashing. Install window and seal to opening and roof flashing. Flashing at window head to be provided as required depending on specific window used. Fig. 3) Shows Dryvit system properly installed a minimum of 2" up from roof. System is held back a minimum of 1/2" from window frame to allow for backer rod and caulking. BACKER ROD AND CAULK AND/OR ADHERE SHINGLES TRIMMED TO COVER STRIP FIG. 2 PRIDE #5 in a Series SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

Building Successfully With Dryvit Residential Systems ATTACHMENT OF SHUTTERS AND DOWNSPOUTS FIG. 1 1/2" MIN. FRAMING MEMBER SUBSTRATE PIPE SLEEVE SEALANT FRAMING MEMBER SUBSTRATE PIPE SLEEVE SEALANT BETWEEN & STRAP CORROSION RESISTANT SCREW Details Are The Key To Success LOUVERS SHUTTER CORROSION RESISTANT SCREW Wherever the system is penetrated for hanging various attachments such as shutters, downspouts, fixtures, etc., always insert proper-sized pipe sleeves first. Then insert the nails or screws through them and seal sleeve openings with sealant. Fig. 1) Insert sleeve so that it holds shutter 1/2" from face of system. Caulk between sleeve and system. Fill sleeve with sealant prior to inserting screw. Fig. 2) Install sleeve flush with face of system. Apply sealant around and inside the sleeve prior to inserting nail or screw. DOWNSPOUT DOWNSPOUT STRAP PRIDE FIG. 2 #6 in a Series SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

Building Successfully With Dryvit Residential Systems Details Are The Key To Success GABLE END/SOFFIT END TERMINATIONS FIG. 1 ROOFING PAPER BLOCKING RAFTER WALL SHEATHING ROOFING PAPER RAFTER WALL SHEATHING PRIDE FIG. 3 1 1 2" MIN. DRIP EDGE 2" MIN. EIFS COMPATIBLE SEALANT DRIP EDGE EIFS COMPATIBLE SEALANT FIG. 2 WALL SHEATHING EIFS COMPATIBLE SEALANT 2" MIN. FIG. 3 Fig. 1) The Dryvit system and blocking are installed prior to the wood trim. The top edge of the Dryvit system shall be wrapped with reinforcing mesh and base coat. The wood trim overlaps the EIFS and is caulked along the bottom edge. The drip edge flashing should extend down at least 2". Fig. 2) Install the Dryvit system encapsulating the top edge of the EPS insulation with base coat and reinforcing mesh. The drip edge flashing extends down a minimum of 2" and is caulked along the lower edge. Fig. 3) Install the Dryvit system prior to the frieze board and trim. Wrap the top edge of the EPS with base coat and reinforcing mesh. The frieze board is fastened to the blocking. Caulk is applied along the bottom edge of the frieze board. MOLDING FRIEZE BOARD 1 1 2" MIN. #7 in a Series SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

APPROVED INSULATION BOARD Building Successfully With Dryvit Residential Systems BOND BREAKER TAPE DEMANDIT OR COLOR PRIME SEALANT FIG. 2 FINISH CLOSED CELL BACKER ROD Details Are The Key To Success SEALANT JOINTS WITH RESIDENTIAL S SEALANT FIG. 1 REINFORCING MESH EMBEDDED IN BASE COAT GAP IN SHEATHING REINFORCING MESH TRIANGULAR BACKER ROD APPROVED INSULATION BOARD FINISH 3/4" MIN. REINFORCING MESH QUARTER ROUND BACKER ROD SEALANT DEMANDIT OR COLOR PRIME ON SURFACE(S) TO RECEIVE SEALANT DEMANDIT OR COLOR PRIME ON SURFACE(S) TO RECEIVE SEALANT APPLY DEMANDIT OR COLOR PRIME TO BASE COAT EIFS-COMPATIBLE SEALANT SLOPE LOWER SURFACE OUTWARD TO DRAIN Fig. 1) Sealant performance is dependent on the width-to-depth ratio of the sealant. The rule of thumb is to apply the sealant half as deep as the joint width but not less than 1/4" nor over 1/2". Refer to specific sealant manufacturer s recommendations for variations. A closed cell backer rod is used to control the sealant depth and shape, provide a backing to tool against and to prevent 3-sided adhesion. Bond breaker tape may be installed in lieu of backer rod where appropriate. Fig. 2) The edges of the Dryvit system, which will receive sealant, must be wrapped with base coat and reinforcing mesh and coated with a smooth coating, such as Demandit or Color Prime. The textured finish should be stopped short of sealant. To ensure proper adhesion, the recommended sealant primer shall always be used. Refer to complete Dryvit details to determine what type of sealant joint is required at typical conditions. PRIDE #8 in a Series SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

SUBSTRATE Building Successfully With Dryvit Residential Systems WINDOW OPENINGS WITH RESIDENTIAL S FIG. 3 FIG. 1 SILL SPINE WATER- RESISTIVE Details Are The Key To Success ROUGH OPENING FIG. 2 6 MEMBRANE 12 3" WINDOW SET IN SEALANT Fig. 1) Prior to installing the window, wrap the rough opening with membrane flashing. The strips are applied in weather-board fashion with the head piece lapping over the jamb pieces, which lap over the sill piece. Fig. 2) A bead of sealant is applied on the window flange; and the window is set into the opening, leveled and secured per manufacturer s instructions. The Dryvit system is then installed leaving a minimum 1/2" gap around the window to install sealant. Windows without integral flashing and ganged windows will need to have proper head flashing installed by field personnel. Fig. 3) The tops of projecting EIFS sills shall be sloped a minimum of 6:12. The Dryvit system is held back from the window for proper sealant application. 1/2" MIN. SUBSTRATE MEMBRANE 1/2" MIN. WEEP TUBE WITH BAFFLES EIFS- COMPATIBLE SEALANT WITH CLOSED CELL BACKER ROD PROVIDE WEEP 2' ON CENTER PRIDE #9 in a Series SUCCESSFUL BUILDERS SHARE THEIR KNOWLEDGE All good builders know how important it is to pay attention to details. In this series, Dryvit focuses on key details that successful builders follow when installing exterior insulation and finish systems. Use these drawings, along with Dryvit s complete system specifications and details, as a helpful guide for you and your subcontractors in planning and coordinating the critical interfaces between exterior building components. S TECHNICAL SUPPORT IS TOPS Throughout North America, we have a field service staff to assist with technical issues. Our corporate engineering staff is prepared to review your Dryvit plans, make suggestions and support your efforts. Total customer satisfaction is our goal. Use our 800 number and benefit from the Dryvit Difference. MAKE SURE IT S A We are the Number One EIFS manufacturer. We offer a number of exterior wall systems including Outsulation RMD and Outsulation SMD Systems. You are off to a great start when you select a Dryvit system. This detail is for general information and guidance only, and Dryvit disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. For additional information, call 1-800-4- or visit www.dryvit.com Dryvit Systems, Inc. 1997

...THE COMPANY As a leading manufacturer of EIF systems for over 35 years, Dryvit Systems, Inc. has provided products for hundreds of thousands of energyefficient, durable and cost-effective walls for commercial and residential buildings nationwide. Dryvit systems are recognized by the design and building community as the best engineered systems available they offer design flexibility and a cost-competitive alternative to other cladding materials. Dryvit systems offered for the residential market include the Outsulation RMD and the Outsulation SMD Systems. Dryvit s commitment to continued research and development, testing and training, compliance with national and local building codes and the strictest quality control in the EIFS industry ensure superior products unmatched in the building community. Also, every Dryvit manufacturing facility is certified to ISO 9001:2000 and ISO 14001:2004 standards, the worldwide common denominator of product consistency and excellence and environmental performance. As quality conscious as Dryvit is, the ultimate success and performance of the Dryvit system and, in truth, any exterior wall cladding depends on the skill and knowledge of the contractor as well as the active involvement of the builder and other subcontractors.

RESIDENTIAL S OUTSULATION RMD The Dryvit Outsulation RMD System is engineered specifically for residential construction. It incorporates a specially designed drainage plane to allow incidental moisture to drain out of the wall at the base of the system. The Outsulation RMD System is mechanically fastened to a plywood or OSB substrate. It offers a transferable 10-year moisture drainage and materials warranty. OUTSULATION RMD COMPONENTS Drainage Medium Approved Mechanical Fasteners Expanded Polystyrene Insulation Board (R-value = 3.85 per inch) Reinforcing Mesh Dryvit Genesis or Genesis DM Base Coat Dryvit 100% Acrylic-Based Dirt Pickup Resistant Finish OUTSULATION SMD The Dryvit Outsulation SMD System was designed specifically for residential applications. In new construction, the insulation board is quickly attached by mechanical fasteners over a drainage plane, which allows for incidental moisture to drain harmlessly out of the wall at the base of the system. Outsulation SMD System is also perfect for remodeling a home because the insulation board can be mechanically fastened to most types of siding found on older homes. OUTSULATION SMD COMPONENTS Drainage Medium Approved Mechanical Fasteners Approved Polyisocyanurate Insulation Board (R-value = 5.6 per inch) Reinforcing Mesh Dryvit Genesis or Genesis DM Base Coat Dryvit 100% Acrylic-Based Dirt Pickup Resistant Finish DESIGN OPTIONS Each system permits three-dimensional detailing with the use of insulation board shapes.

15 KEYS TO SUCCESSFULLY BUILD OR REMODEL A HOME WITH Review All Details With EIFS Contractor, Roofer & Framer. Ensure all wall components, including windows, meet building code requirements Expansion joints at each floor line System terminations are detailed per EIF System Installation Instructions Deck flashing properly installed Wall sheathing properly installed Proper installation of water-resistive barrier Window and door heads properly flashed Proper caulking at windows, expansion joints, other openings Proper flashing where roof intersects wall Proper flashing at crickets and chimneys Frieze boards installed over the Dryvit system System is terminated above patios, decks, landings Insulation board is terminated a minimum of 203 mm (8") above grade Ambient temperature 4 C (40º F) and rising during installation and 24 hours thereafter Follow Dryvit s specifications, application instructions and details Dryvit...striving to help you eliminate call-backs We are available at www.dryvit.com and 1-800-556-7752

Dryvit Systems, Inc. One Energy Way P.O. Box 1014 West Warwick, RI 02893 800-556-7752 401-822-4100 www.dryvit.com Dryvit Systems, Inc. 1996 Printed in U.S.A. 8-08-5M R5-8-20-08 Information contained in this brochure conforms to the standard detail recommendations and specifications for the installation of Dryvit Systems, Inc. products as of the date of publication of this document and is presented in good faith. Dryvit Systems, Inc. assumes no liability, expressed or implied, as to the architecture, engineering or workmanship of any project. To ensure that you are using the latest, most complete information, contact Dryvit Systems, Inc.