Economical and eco-friendly liquid applied roof waterproofing solution based on Sika Co-Elastic Technology (CET)

Similar documents
PRODUCT DATA SHEET Sikalastic -590

Economical and eco-friendly liquid applied roof waterproofing solution based on Sika Co-Elastic Technology (CET)

ECONOMICAL AND ECO-FRIENDLY LIQUID APPLIED ROOF WATERPROOFING SOLUTION BASED ON SIKA CO- ELASTIC TECHNOLOGY (CET)

PRODUCT DATA SHEET Sikalastic -560

Economical and eco-friendly liquid applied roof waterproofing solution based on Sika Co-Elastic Technology (CET)

PRODUCT DATA SHEET Sikalastic -560

PRODUCT DATA SHEET Sikalastic -501 Roofseal Plus

Two-component solvent-free polyurethane adhesive used in the construction of SikaRoof MTC Cold Bonding. Twin-pack product

Conforms to the requirements of ETAG Certificate: European Technical Approval No. ETA-05/0265

Construction. Sikalastic -601 BC. High performance, versatile and easily applied liquid Roof. Waterproofing Base Coat. (Decothane Base Coat)

Spray applied modified polyurea membrane

Spray applied waterproofing membrane

2-part water dispersed epoxy coating

2-part epoxy primer, levelling mortar, intermediate layer and mortar screed

Liquid applied polyurea hybrid membrane

Liquid applied pure polyurea membrane

Cost-effective, single component, polyurethane, liquid waterproofing membrane

Construction. 2-part epoxy primer. Product Data

Construction. Sikafloor N Elastic. 1-part PUR highly elastic coating. Product Data Sheet Version 29/03/2011(Corporate edition 12/08/2010)

Construction. Spray applied modified polyurea membrane. Product Description

High performance, versatile and easily applied liquid Roof Waterproofing Base Coat

PRODUCT DATA SHEET Sikafloor -242 LC

Two component spray applied roof waterproofing membrane

Sikafloor -264 is a two part, economic, solvent-free coloured epoxy resin, suitable for use under hot climate condition.

Product Datasheet CaltechLOW

Construction. 2-part water based protective epoxy coating. Product Description. Product Data. Tests. Form

Appearance /Colours Resin - part A: transparent, liquid Hardener - part B: transparent, liquid Packaging. Pre-proportioned 5.

Sikafloor -375 is a two part, solvent free, low viscosity, tough elastic, crackbridging polyurethane resin coating. CHARACTERISTICS / ADVANTAGES

2-part, electrostatically conductive epoxy coating

PRODUCT DATA SHEET Sikafloor -378

3-component epoxy self-smoothing screed

2-part, electrostatically conductive epoxy coating

2-part PUR tough-elastic coloured seal coat

Sikalastic -821 LV is a two part, elastic, crack-bridging, rapid-curing polyurethane membrane. Sikalastic -821 LV is for machine application only.

Construction. Sikalastic -602 BR. High performance, root resistant and easily applied liquid Roof Waterproofing Base Coat.

Sikagard -63 N is a total solid (acc. test method of Deutsche Bauchemie), two part epoxy resin coating.

Ultra fast spray applied polyurethane membrane

Construction. Two-part Epoxy Roller and Seal Coat. Product Data Sheet Edition No. 01 (October 2015) Sikafloor -264 HC. Product Description

PRODUCT DATA SHEET Sikafloor -264 HC

Construction. Sikalastic -622 TR. High performance, root resistant and easily applied liquid Roof Waterproofing Top Coat.

Spray applied polyurea membrane

1-part PUR highly elastic coating

Sikafloor -264 HC is a two part, economic, solvent-free coloured epoxy resin.

2-part epoxy primer, levelling mortar and mortar screed

Ultra Fast Curing Polyurethane Waterproofing Membrane System

Good chemical and mechanical resistance Easy application Economical Liquid proof Gloss finish Slip resistant surface possible

2-part water based epoxy coating. Sikafloor W is a two part, water dispersed, solvent free, coloured, epoxy resin based coating.

Construction. 2-part epoxy roller and seal coat. Product Description. Product Data. Form. Storage. Product Data Sheet Edition _1

Sikafloor -161 is an economic, two part, solvent free, low viscosity epoxy resin, suitable for use under hot climate condition.

2-part PUR tough elastic, crack-bridging coating

2-part, electrostatic conductive epoxy coating

2-part Epoxy coating and seal coat

2-part self smoothing epoxy coating, highly chemically and mechanically resistant

PRODUCT DATA SHEET Sikafloor -381

Construction. 2-part epoxy protective coating. Product Description. Product Data 1 1/5. Test. Form. Storage

PRODUCT DATA SHEET Sikafloor -263 SL HC

Sikafloor -264 HC is a two part, economic, solvent-free coloured epoxy resin.

PRODUCT DATA SHEET Sikafloor -264 HC

Construction. 3-part cement and epoxy combination micro mortar for surface sealing. Product Description 1 1/5. Tests

Construction. 2-part epoxy impregnation resin. 1 Sikadur /5. Product Data Sheet Edition No. 01 (October 2015) Sikadur -330.

Single pack, solvent based Polyurethane, used in Balcony 10, 15 and 20 waterproofing systems

2-part epoxy primer, levelling mortar, intermediate layer and mortar screed

PRODUCT DATA SHEET Sikafloor -264 HC

Construction. 2-part epoxy roller and seal coat. Product Description

2-part self smoothing epoxy coating, highly chemically and mechanically resistant

Construction. Cementitious self levelling, fast hardening, underlayment for use 2-10mm, and 10-30mm with added aggregate. Product Description

Primer and Moisture Control for Wood Floor Bonding with Elastic SikaBond Adhesives on Difficult Substrates

Construction. 2-part epoxy impregnation resin. 1 Sikadur /6

2-part PUR tough-elastic, low-voc, self-smoothing floor

2-part epoxy self-smoothing and broadcast system. Sikafloor -263 SLHC is a two part, economic, multi purpose binder based on epoxy resin.

PRODUCT DATA SHEET Sikafloor -161

Protective coating for exposed concrete

Construction. Sikalastic -841 ST. Liquid applied pure polyurea membrane. Product Description

2-Part Epoxy Primer, Levelling Mortar and Mortar Screed

Highly durable, UV-stable, versatile and easily applied liquid Roof Waterproofing Top coat

PRODUCT DATA SHEET Sikafloor 359 N

PRODUCT DATA SHEET Sikafloor -220 W Conductive

2-part epoxy impregnation resin

2-part PUR highly elastic, crack-bridging coating

2-part PUR highly elastic, crack-bridging coating

Construction. Sodium silicate based surface hardener, dustproofer, sealing and curing compound for concrete. Product Description.

CHARACTERISTICS / ADVANTAGES

Sikafloor -161 HC is an economic, two part, solvent free, low viscosity epoxy resin.

2-part epoxy primer, levelling mortar, intermediate layer and mortar screed

Construction. Sikagard Part Epoxy Protective Coating. Product Data Sheet Version 20/07/2011(Corporate edition 28/03/2011) Product Description

PRODUCT DATA SHEET Sikafloor -161

Construction. Sikadur Part Epoxy Impregnation Resin. Product Data Sheet Version 04/03/2011(Corporate edition 02/09/2010)

Construction. 2-part High-build Solvent Free Epoxy Coating. Product Description. Product Data. Storage

Highly Chemical Resistant Laminate System. Sika Asplit VEL is 2 part, glass fabric reinforced, vinyl-ester based coating and lining system.

2-part epoxy self-smoothing and broadcast system

PRODUCT DATA SHEET. Sikalastic -621 TC PRODUCT DESCRIPTION

2-part epoxy textured roller and seal coat

PRODUCT DATA SHEET Sikalastic Rapid-721

Construction. One component cementitious mortar fibre reinforced for flexible waterproofing. Product Description. Product Data. Form.

PRODUCT DATA SHEET Sikafloor -81 EpoCem New HC

LAMPIRAN A DATA SIKAFIBRE

PRODUCT DATA SHEET Sikafloor -156

Single component, polyurethane, liquid waterproofing membrane

High-performance Anchoring Adhesive

Transcription:

Technical Data Sheet Edition 3, 2011 Identification no. 02 09 15 15 100 0 000004 Version no. 0010 Sikalastic -560 Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution based on Sika Co-Elastic Technology (CET) Construction Product Description Uses Characteristics / Advantages Environmental Information Specific Characteristics Product Data Form Appearance / Colours Packaging Storage Storage Conditions / Shelf Life Technical Data Sikalastic -560 is a cold-applied, one-component solvent free liquid applied waterproofing membrane, highly elastic and UV-resistant. For roof waterproofing solutions in both new construction and refurbishment projects For roofs with many details and complex geometry when accessibility is limited For cost efficient life cycle extension of failing roofs For reflective coating to enhance energy efficiency by reducing cooling costs. UV resistant and resistant to yellowing and weathering Highly elastic and crack-bridging Non-toxic and VOC compliant water based coating One component - ready to use Excellent adhesion on porous and non porous substrates Seamless waterproofing membrane Water vapour permeable 12 months shelf life Non-toxic and VOC compliant water based coating Odourless Conforms to the requirements of LEED EQ Credit 4.2: Low-Emitting Material: Paints & Coatings: VOC <100 g/l Fulfils initial solar reflectance requirements acc. Energy Star (0.820) Grey, terracotta, red and white (Energy Star) 5 kg, 10 kg and 20 kg plastic pails 12 months from date of production if stored properly in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 C and +30 C. Chemical Base Polyurethane modified Acrylic Dispersion Density 1.35 kg/l (EN ISO 2811-1) All density values at +23 C Solid Content ~ 48% by volume / ~ 65% by weight Service -10 C to +80 C (with fleece) -5 C to +80 C (without fleece) CIGS-Reflectance (initial) 87% Sikalastic -560 white according to EN 410 in conjunction with CIGS sensitivity Solar Reflectance (initial) 0.82 Sikalastic -560 white according to ASTM C 1549 Initial Emmitance 0.93 Sikalastic -560 white according to ASTM E 408, C1371, others Back Table of contents 1 Sikalastic -560 1/6

SRI (Solar Reflectance Index) (initial) Sikalastic -560 white 102 according to ASTM E 1980 All values related to the reflectance/emittance properties provided in this Product Data Sheet refer to the initial ( properly cured, non-weathered) status of the product. Mechanical / Physical Properties Tensile Strength Free film: ~ 1.5 N/mm 2 (DIN 53504) With Sikalastic Fleece-120: ~ 12 N/mm 2 (DIN 53504) Elongation at Break Free film: ~ 350% (DIN 53504) With Sikalastic Fleece-120: ~ 40-60% (DIN 53504) System Information System Structure Waterproofing without Fleece For UV-stable coating, for extend life of old roofs or as reflective coating to enhance energy efficiency. Build up: Sikalastic -560 applied in one or two coats Substrates: Concrete, metals, wood, tiles Primer: Please refer to Sikalastic Primer-Cleaner chart below Total thickness: ~ 0.3 0.5 mm Total consumption: ~ 0.9 1.4 kg/m 2 Waterproofing with Fleece For cost efficient waterproofing solutions in new construction and refurbishment projects. Build up: Sikalastic -560 applied in two coats and reinforced with Sikalastic Fleece-120 and sealed with one or two additional coats of Sikalastic -560 Substrates: Concrete, metals, wood, tiles Primer: Please refer to Sikalastic Primer-Cleaner chart below Total thickness: ~ 1.0-1.3 mm Total consumption: ~ 2.1 2.8 kg/m 2 Sikalastic Fleece-120 is applied at areas with high movements, irregular substrate or to bridge cracks, joints and seams on the substrate as well as for details. 2 Sikalastic -560 2/6

Application Details Substrate Treatment Cementitious substrates: New concrete should be cured for at least 28 days and should have a Pull off strength 1.5 N/mm 2. Cementitious or mineral based substrates must be prepared mechanically using abrasive blast cleaning or scarifying equipment to remove cement laitance and to achieve an open textured surface. Loose friable material and weak concrete must be completely removed and surface defects such as blowholes and voids must be fully exposed. Repairs to the substrate, filling of joints, blowholes/voids and surface levelling must be carried out using appropriate products from the Sikafloor, SikaDur and SikaGard range of materials. High spots must be removed by e.g. grinding. Outgassing is a naturally occurring phenomenon of concrete that can produce pinholes in subsequently applied coatings. The concrete must be carefully assessed for moisture content, air entrapment, and surface finish prior to any coating work. Installing the membrane either when the concrete temperature is falling or stable can reduce outgassing. It is generally beneficial, therefore, to apply the embedment coat in the late afternoon or evening. Prime the substrate and always use a reinforced system. Brick and stone: Mortar joints must be sound and preferably flush pointed. Use localised reinforcement over joints and prime before applying Sikalastic -560. Slates, tiles, etc.: Ensure all slates/tiles are sound and securely fastened, replacing obviously broken or missing sections. Fully glazed tiles must be abraded prior to priming and subsequent treatment with Sikalastic -560. Bituminous felt: Ensure that Bituminous felt is firmly adhered or mechanically fixed to the substrate. Bituminous felt should not contain any badly degraded areas. Prime and always use a totally reinforced system. Bituminous coatings: Bituminous coatings should not have sticky or mobile surfaces, volatile mastic coatings, or old coal tar coatings. Prime and always use a totally reinforced system. Metals: Metals must be in sound condition. Abrade exposed surfaces to reveal bright metal. Use localised reinforcement over joints and fixings. Wooden substrates: Timber and timber based panel roof decks are to be in good condition, firmly adhered, or mechanically fixed. Paints/Coatings: Ensure the existing material is sound and firmly adhered. Remove any oxidized layers and use localised reinforcement over joints. Existing SikaRoof CET Systems The existing SikaRoof CET Systems should still be soundly adhered to the substrate. 3 Sikalastic -560 3/6

Substrate Preparation Substrate Priming Substrate Primer Consumption (kg/m²) Cementitious substrates, Brick and Stone, Slate, tiles, etc, Bituminous felt, Bituminous coatings, Metals,Wooden substrates, and paints Sikalastic -560 diluted with 10% water. 0.3 Application Conditions / Limitations Substrate Ambient Substrate Moisture Content Relative Air Humidity Dew Point Application Instructions Mixing Application Method / Tools These figures are theoretical and do not include for any additional material required due to surface porosity, surface profile, variations in level and wastage etc. +8 C min. / +35 C max. +8 C min. / +35 C max. < 6 % moisture content. No rising moisture according to ASTM (Polyethylene-sheet). No water / moisture / condensation on the substrate. 80 % max. Beware of condensation. Surface temperature during application must be at least +3 C above dew point. Prior to application, stir Sikalastic -560 thoroughly for 1 minute in order to achieve a homogeneous mixture. Over mixing must be avoided to minimise air entrainment. Application Method (please refer to the most recent issue of the Method Statement) Prior the application of Sikalastic -560 the priming coat must have cured tack-free. For the Waiting Time / Overcoating please refer to the PDS of the appropriate primer. Damageable areas (door frame) have to be protected with an adhesive tape. Waterproofing without Fleece: Sikalastic -560 is applied in two coats. Prior to the application of a 2nd coat the indicated waiting time in the table below Waiting Time / Overcoating shall be allowed. Waterproofing with Fleece : Sikalastic -560 is applied in combination with Sikalastic Fleece 120. 1. Apply first coat of appr 1.0 kg/m 2 of Sikalastic -560 on a length of approx. 1m. 2. Roll in the Sikalastic Fleece-120 and ensure that there are no bubbles or creases. Overlapping of the fleece minimal 5 cm. 3. Apply second coat of appr. 0.5 kg/m 2 coat right into the wet fleece to achieve the required film thickness. The entire application shall happen while Sikalastic -560 is still liquid, wet in wet. 4. Repeat step 1-3 until the roof area is waterproof. 5. After the two coats are dry, seal the roof area with one or more additional coats of Sikalastic -560 ( 0.5 kg/m² per coat). Please note, always begin with details prior starting with waterproofing the horizontal surface. For details follow step 1-5. Tools: Jet washer: If dust, vegetation, moss / algae or other contaminants are present on the existing roof, a power washer is required to clean the substrate prior to the application of SikaRoof Systems. Existing chippings should be removed by hand or scabbling prior to power washing. Squeegee: Useful when removing excess water from the roof after overnight rain Drill and paddle: Sikalastic -560 should be mixed for one minute using a drill and paddle. 4 Sikalastic -560 4/6

Solvent resistant short-piled lamb skin roller: Used in the application of Sikalastic -560 to ensure a consistent thickness of the seamless SikaRoof systems. Thick hair brush: For application of Sikalastic -560 to all details and penetrations. Stanley knife: This tool is required when cutting Sikalastic Vap, Sikalastic Insulation and Sikalastic Carrier. When the Sikalastic Insulation is resting on an uneven substrate, the back of the board should be cut to enable maximum contact with Sikalastic Coldstick. Saw: Used when cutting thick Sikalastic Insulation boards. Airless spray equipment: Used only for the roof coating systems. Two spray applied layers is the minimum requirement. The pump should have the following parameter: -min. pressure: 220 bar -min. output: 5.1 l/min -min. Ø nozzle: 0.83mm (0.033 inch) For example: Wagner Heavycoat HC 940 E SSP Spraypack Cleaning of Tools Waiting Time / Overcoating Clean all tools and application equipment with water immediately after use. Hardened / cured material can only be removed mechanically Before applying Sikalastic -560 on primer Sikalastic -560 diluted with 10% water: Substrate Relative humidity Minimum Maximum +10 C 50% ~ 4 hours After thorough cleaning 1) +20 C 50% ~ 2 hours Sikalastic -560 can be +30 C 50% ~ 1 hours overworked at any time Before applying Sikalastic -560 on Sikalastic -560 (without fleece) allow 1st coat to dry: Substrate Relative humidity Minimum Maximum +10 C 50% ~ 8 hours After thorough cleaning 1) +20 C 50% ~ 6 hours Sikalastic -560 can be overworked with itself at +30 C 50% ~ 4 hours any time 1) Assuming that all dirt has been removed and contamination is avoided. Before applying Sikalastic -560 on Sikalastic -560 (with fleece) allow 1st coat to dry: Substrate Relative humidity Minimum Maximum +10 C 50% ~ 36 hours After thorough cleaning 1) +20 C 50% ~ 24 hours Sikalastic -560 can be overworked with itself at +30 C 50% ~ 12 hours any time Note: Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity. Notes on Application / Limitations Do not apply Sikalastic -560 on substrates with rising moisture. Always apply during falling ambient and substrate temperature. If applied during rising temperatures pin holing may occur from rising air. Ensure that Sikalastic -560 is totally dry and the surface is without pinholes before applying any top coat. Do not allow temporary ponding to remain between coats on any horizontal surfaces or until the final coating has totally cured. Brush or mop surface water away during this time. Sikalastic -560 should not be applied on roofs subject to long-term ponding water with subsequent periods of frost. In cold climatic zones for Roofing structures with a pitch of less than 3% appropriate measures must have to be considered. 5 Sikalastic -560 5/6

Construction Curing Details Applied Product ready for use Value Base Local Restrictions Health and Safety Information Legal Notes EU Regulation 2004/42 VOC - Decopaint Directive Sikalastic -560 applied on roofs subject to long-term freezing at temperature around the minimum service temperature of -10 C sho uld always be reinforced with Sikalastic Fleece-120 in order to guarantee sufficient crack-bridging ability. Do not apply Sikalastic -560 directly on insulation boards. Instead use a separation layer like Sikalastic -Carrier between insulation board and Sikalastic - 560. Sikalastic Fleece-120 can be used as total reinforcement or for partial reinforcements over dynamic cracks and joints. Sikalastic -560 is not recommended for pedestrian traffic. In case pedestrian traffic is unavoidable, Sikalastic -560 shall be covered with appropriate elements such as tiles, stone plates or wooden panels. Do not apply cementitious products (e.g. tile mortar) directly onto Sikalastic -560. Use an alkaline barrier, for example kiln dried quartz sand. The fire resistance performance has been tested internally according to ENV 1187 B Roof (T1) Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity. Substrate Relative humidity Touch dry Rain Resistant Full cure +10 C 50% ~ 4 hours ~ 12 hours ~ 6 days +20 C 50% ~ 2 hours ~ 8 hours ~ 4 days +30 C 50% ~ 1 hours ~ 4 hours ~ 2 days Note: Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity. All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika s current knowledge and experience of the product when properly stored, handled and applied under normal conditions in accordances with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. According to the EU-Directive 2004/42, the maximum allowed content of VOC (Product category IIA / j type sb) is 550 / 500 g/l (Limits 2007 / 2010) for the ready to use product. The maximum content of Sikalastic -560 is < 500 g/l VOC for the ready to use product. PT. Sika Indonesia Jl. Raya Cibinong- Bekasi km. 20 Limusnunggal- Cileungsi BOGOR 16820 - Indonesia Tel. +62 21 8230025 Fax +62 21 8230026 Website : www.sika.co. id e-mail: sikacare@id.sika.com Branches Surabaya : Komp. Pergudangan Meiko Abadi III Blok B-52 & B-53, Betro, Gedangan, Sidoarjo 61254 Tel : 031-8911333; Fax : 031-8916333 Medan : Jl. Pancing / Jl. Willem Iskandar No.66 B, Kec. Medan Tembung Tel : 061-6619500; Fax : (061) 6619400 Batam : Jl. Laksamana Bintan, Komp. Bumi Riau Makmur Blok E No.3, Sungai Panas Tel : (0778) 424928; Fax : (0778) 450189 6 Sikalastic -560 6/6