DESIGNATED SUBSTANCES REPORT

Similar documents
patersongroup 1.0 BACKGROUND 2.0 SITE INSPECTION AND OBSERVATIONS Consulting Engineers November 15, 2016 File: PE3915-LET.01

Designated Substance Sampling, 1631 Queen Street East, Toronto, ON

patersongroup 1.0 BACKGROUND Consulting Engineers August 31, 2012 File: PE2734-LET.01 Bassi Construction 2575 Del Zotto Drive Ottawa, Ontario K1T 3V6

HAZARDOUS BUILDING MATERIALS SURVEY

PRE-RENOVATION SURVEY FOR DESIGNATED SUBSTANCES. Good Neighbours Club Community Centre 170 Jarvis Street Toronto, Ontario

WHY SHOULD PROJECT OWNERS PROVIDE A LIST OF DESIGNATED SUBSTANCES?

InAIR Environmental Ltd.

Reference: OTCD B 17 September Soil Sampling Program th Line Road, Metcalfe, ON

OWNER S DUTIES. Designated Substances on construction projects BEFORE CONTRACTS ARE FINALIZED, THE PROJECT OWNER MUST DO THE FOLLOWING

Pre-Demolition Hazardous Building Materials Survey

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY

REAL ESTATE & FACILITIES MANAGEMENT Facilities Planning & Development

ANNUAL SURVEY FOR DESIGNATED SUBSTANCES AND HAZARDOUS MATERIALS

Designated Substances Survey Guelph Greyhound Station 141 Macdonell Street Guelph, Ontario

Submitted to: Ms. Susanne Poltrok Morguard Investments Limited 55 City Centre Drive Suite 800 Mississauga, Ontario L5B 1M3

Asbestos Analytical Services Ltd East Kent Avenue N., Vancouver, BC, V5S 3T9

Ontario Inc. March 10, Jardin Des Sapins Orleans, ON

patersongroup Consulting Engineers October 7, 2010 File: PE2100-LET.01 Springcress Properties Inc. 6 Gurdwara Road, Suite 200 Ottawa, Ontario K2E 8A3

DESIGNATED SUBSTANCE SURVEY. Laurentian University Science Building 2B MOD Project Sudbury, Ontario

Lead Management Program for Building Maintenance and Construction Projects. Office of Environmental Health and Safety University of Toronto

DESIGNATED SUBSTANCE SURVEY REPORT PERTH & DISTRICT COLLEGIATE INSTITUTE PERTH, ONTARIO

DESIGNATED SUBSTANCES SURVEY 30 Carrier Drive Toronto, ON

Mr. Charles Michal Weller & Michal Architects, Inc. 71 Main Street, Mill #2 Claremont, New Hampshire TLG File Number

REAL ESTATE & FACILITIES MANAGEMENT Facilities Planning & Development

PROJECT NO REPORT TO CITY OF STRATFORD ASBESTOS CONTAINING MATERIALS SURVEY ROW HOUSES STRATFORD, ONTARIO CONDUCTED BY:

Hazardous Building Materials Assessment St. Louis Elementary School 75 Allen Street Waterloo, Ontario

ADDENDUM NO. 1 TENDER CALL NO FOR THE RENOVATION OF BUILDING B AT 320 BERING AVE., TORONTO.

Ensure policy is adhered to by all employees. Follow policy requirements.

Roseville OFFICE* 1911 Douglas Blvd, ste * Roseville, CA Phone (916) * Fax (916) *

BUILDING ENVIRONMENTAL AUDIT. Good Neighbours Club Community Centre 170 Jarvis Street Toronto, Ontario

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY

Project & Environmental Review. Guidelines Demolition. May 2016

202 Pitt Street, Cornwall, ON Designated Substances Survey APPENDIX E. Pinchin Report (2006, 2008 & 2009)

ASBESTOS MANAGEMENT PLAN PROCEDURE

REAL ESTATE & FACILITIES MANAGEMENT Facilities Planning & Development

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY

Hazardous Building Materials Assessment 240 Manor Road East, Toronto, Ontario

Rowan University Asbestos Management Program

PCB DELINEATION AND SOURCE BULK SAMPLING REPORT

MIE - H&S WHMIS

LEAD HAZARD CONTROL PROGRAM

INVITATION TO TENDER ITT NO. PS KITSILANO ARENA CHILLER REPLACEMENT AMENDMENT No. 1

LIMITED POTENTIALLY HAZARDOUS MATERIAL BUILDING INSPECTION REPORT AND ASBESTOS BUILDING INSPECTION REPORT. for

Targeted Designated Substance Report J. Alphonse Dulude Arena Clyde Ave., Ottawa, ON

REPORT. Asbestos-Containing Building Materials Assessment Report - Nutana Lawn Bowling Storage Garage CITY OF SASKATOON.

Construction Products (Toxic [6.7A]) Group Standard HSR002545

ASBESTOS ASSESSMENT Curtis House Memorial University of Newfoundland St. John s, NL

Asbestos Consulting Radon Measurements Lead Assessments Indoor Air Quality Testing Mold Investigations. Project Number: Page 1 of 22

202 Pitt Street, Cornwall, ON Designated Substances Survey APPENDIX E. Pinchin Report (2006, 2008 & 2009)

This addendum is to be read with and constitutes part of the bid document.

FINAL Hazardous Building Materials Assessment Chebucto Road, Halifax, Nova Scotia

In general, the management plan development process consisted of:

ASBESTOS CONTAINING MATERIALS (ACM) REFERENCE GUIDE. Environmental Health & Safety Office

HAZARDOUS BUILDING MATERIALS SURVEY

DIVISION 02 SELECTIVE DEMOLITION

Hazardous Materials G

25, 2017 CITY OF SASKATOON

Engineers and. Limited Asbestos and Lead Containing Materials Evaluation 273 D Street & 244 Athens Street Boston, Massachusetts

Limited Asbestos Demolition Survey

TABLE OF CONTENTS 4. PREPARATION, COMMUNICATIONS, AND CONTROLS

Hazardous Building Materials Assessment 20 Westgate Street, Winnipeg, Manitoba

Office of Environmental Health and Safety 1.0 INTRODUCTION

Regulated Material Investigation Lead Base Paint Sampling. KVAL Broadcasting Eugene, Oregon. April 30, 2018

Document Number: SILICA CONTROL ZSD-S-MSAFEca Issue Date: August 28, 2017 Revision #: 4 Next Review Date: May 28, 2022

CHAPTER 34 ASBESTOS. Where is it Found? 34 ASBESTOS. What is Asbestos?

REAL ESTATE & FACILITIES MANAGEMENT Facilities Planning & Development

EXECUTIVE SUMMARY. The following paint samples submitted for analysis were found to exceed the criteria for lead in paint (600ppm).

Asbestos and Lead Considerations in Construction Projects. Sean Purcer Senior Consultant Anthony Price Senior Consultant

ETERNAL MEMORIALS ASBESTOS SURVEY REPORT

*************************************************************************** SECTION F20 SELECTIVE BUILDING DEMOLITION 09/16

FINAL Hazardous Building Materials Assessment 801 Low Level Road, North Vancouver, BC

AWS 1500 October 19, Karen Maloney, Assistant Superintendent Novato Unified School District 1015 Seventh Street Novato, CA 94945

NORWELL PUBLIC LIBRARY 64 South St, Norwell, MA 02061

ASBESTOS INSPECTION REPORT 3801 HARNEY STREET OMAHA, NEBRASKA 68132

ASBESTOS SURVEY. Old Detective s Building Wadesboro, NC INSPECTED &PREPARED BY:

NESHAP Pre-Demolition Asbestos Survey

S (Blacksburg Hwy) Bridge over I-85 (Exit 100) Cherokee County, South Carolina Asbestos and Lead-Based Paint Survey Report - Revised

BuildingName The Description of the Project P DOCUMENTS

PIER 26 and 28 BULKHEAD LIMITED ASBESTOS and LEAD SURVEY NTE Project No.: NT-3278

POTENTIALLY HAZARDOUS MATERIALS BUILDING INSPECTION REPORT. for

APPENDIX I. DST Hazardous Material Assessment. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX I

EPA s Lead Program Rule At-A-Glance

Read Health Canada s Tools for schools Action Kit s Introduction, Backgrounder and pages 14-3 to

Bucknell University. Lewisburg, Pennsylvania HUNT HALL IMPROVEMENTS 2017 PROJECT LOCATION MAP CS-1 DRAWING TITLE: PROJECT:

Dr. Gerhard Herzberg Park Aquatic Rec-Unit Asbestos Survey Report

Pre-Renovation Hazardous Building Materials Survey

Cosmo Senior Center Asbestos Survey Report

SECTION SELECTIVE DEMOLITION

2650 Queensview Drive Ottawa, Ontario, K2B 8H6, CANADA T: Proposed Development, 1158 Second Line Road, Ottawa, ON

Certification Number: NAT Lead Renovation, Repair and Painting Program

HMIS Quick Reference Guide

City of Saskatoon #9 450 Ontario Avenue Asbestos Survey Report

FINAL Hazardous Building Materials Assessment Windsor Street, Halifax, Nova Scotia

PROCEDURE (Essex) / Linked SOP (Kent) Asbestos Management. Number: U 1005 Date Published: 22 July 2015

AMENDMENT NO.: 3 TO THE TENDER DOCUMENTS

CITY OF SASKATOON SURVEYOR S BUILDING ASBESTOS SURVEY REPORT

PRE-DEMOLITION HAZARDOUS BUILDING MATERIALS SURVEY

Prepared for Florida State University Facilities Planning& Construction By Environmental Health & Safety Tallahassee, Fl

PCB DELINEATION SAMPLING

FINAL Hazardous Building Materials Assessment Windsor Street, Halifax, Nova Scotia

Transcription:

Replacement of Hangers Doors Ottawa, Ontario Page 1 of 4 PART 1 GENERAL 1.1 Regulatory Requirements.1 The following Designated Substances Report (DSR) was prepared in order to meet the owners or engineer s requirements under:.1 Section 30, of the Occupational Health and Safety Act, Revised Statutes of Ontario, 1990, Chapter 0.1..2 The Canada Labour Code, Part II, Sections 124 & 125..3 Ontario Regulation 347/90 General Waste Management, as amended to O. Reg. 326/03..2 The designated substances identified in the Occupational Health and Safety Act and its corresponding regulations are:.1 Acrylonitrile: O. Reg. 835/90 as amended by O. Reg. 101/04..2 Arsenic: O. Reg. 836/90 as amended by O. Reg. 102/04..3 Asbestos:.1 O. Reg. 837 as amended by O. Reg. 279/05..2 O. Reg. 278/05..4 Benzene: O. Reg. 839/90 as amended by O. Reg. 105/04..5 Coke Oven Emissions: O. Reg. 840/90 as amended by O. Reg. 106/04..6 Ethylene Oxide: O. Reg. 841/90 as amended by O. Reg. 107/04..7 Isocyanates: O. Reg. 842/90 as amended by O. Reg. 108/04..8 Lead: O. Reg. 843/90 as amended by O. Reg. 109/04..9 Mercury: O. Reg. 844/90 as amended by O. Reg. 110/04..10 Silica: O. Reg. 845/90 as amended by O. Reg. 606/05..11 Vinyl Chloride: O. Reg. 846/90 as amended by O. Reg. 112/04..3 The Guide to Green Government sets out the policy requirements for the federal government to comply with the most stringent environmental regulations, federal or provincial. Also, under the Code of Environmental Stewardship, the federal government has committed to meet or exceed the letter and spirit of federal environmental laws. Within the Guide to Green Government, pollution prevention efforts are required in federal projects. Pollution prevention is defined as the use of processes, practices, materials, products or energy that avoids or minimizes the creation of pollutants and waste, and reduces overall risk to human health and the environment. These policies must be adhered to throughout the duration of any projects performed at 3257 Carp Road, Ottawa..4 Disposal of construction debris and waste are controlled by Regulation 347/90 as amended to O. Reg. 326/03 under the Environmental Protection Act..5 Notification:.1 All contractors requesting tenders from subcontractors shall provide this report to subcontractors..2 Contractors are required, on the Ontario Ministry of Labour Notice of Project form, to list all Designated Substances that may be used, handled or disturbed by work on the project. This includes Designated Substances already present as part of the structure or finishes as well as Designated Substances brought to the project site by the contractor.

Replacement of Hangers Doors Ottawa, Ontario Page 2 of 4 1.2 Scope and Validity Date PART 2 DESIGNATED SUBSTANCES.3 Submit to the Engineer a copy of all notifications prior to the start of work..1 The following report was prepared to provide an overall view of designated substances that were confirmed or potentially present in the following locations of 3257 Carp Road, Ottawa, Ontario:.1 West interior and exterior walls of Hanger.2 An assessment must be made prior to commencing any project to ensure that the information presented herein reflects the scope of work and the requirements of the proposed project. It is important to note that more specific sampling may be required depending on the scope of work and the area affected by the proposed project(s)..3 The following report was prepared by Kiama Engineering Inc. (KEI) by conducting a survey on January 12, 2012. Since that time, designated substances may have been removed from or added to the project area..4 The scope of work for this report involved a visual inspection of all accessible areas of the select room, which may present designated substance within the building s material and finish. Included in the scope of work was the survey for polychlorinated biphenyls (PCBs) and ozone depleting substances (ODS)..1 On the basis of this inspection suspected lead based paint samples were collected for analysis. The samples were submitted to Paracel Laboratories Ltd. in Ottawa, Ontario (an accredited NVLAP laboratory)..2 Summary tables of the analytical test results (paint) are presented at the end of this section..3 The surveys, visual inspections and sampling were limited to readily accessible areas by non-destructive means. Destructive testing was not included in the investigation, however, is recommended prior to any major demolition. Due to the nature of building construction, some inherent limitations exist as to the possible thoroughness of the designated substances surveys. The surveys did not include the demolition of floors, floor finishes, plaster ceilings or walls or other areas to examine concealed conditions..6 It is possible that the designated substances mentioned above are present in non-accessed areas and concealed spaces (i.e., wall and ceiling cavities)..7 In addition, the survey does not refer to substances that may be present in the day-to-day usage for other specialized equipment or area in the building (i.e. portable equipment, lead shields, fume hoods, etc.). There is a possibility that materials may exist which could not be reasonably identified within the scope of this assessment, or which were not apparent during previous site visits..5 Prior to beginning work, confirm with Engineer that additional designated substances have not been brought to the project area. 2.1 SURVEY RESULTS.1 ACRYLONITRILE: Not Identified.2 ARSENIC: Not Identified.3 ASBESTOS: Not identified.4 BENZENE: Not Identified.5 COKE OVEN EMISSIONS: Not Identified.6 ETHYLENE OXIDE: Not Identified

Replacement of Hangers Doors Ottawa, Ontario Page 3 of 4.7 ISOCYANATES: Not Identified.8 LEAD: Identified According to the proposed Lead in Paint and Dust Guidelines, Revision 4, March 2001, by Health Canada s Occupational Health and Safety Agency, paint is considered to be a lead-based if the concentration of lead in the paint is equal to or greater than 0.5 percent by weight, which is equivalent to 5000 ppm. The Ontario Ministry of Labour (MOL) Draft Proposed Lead Regula tion on Construction Projects, made under the Occupational Health and Safety Act, May 5, 1995, states that the removal of lead paint is not required unless work on these materials are likely to produce airborne lead dust or fumes. For example, this could occur during welding, torch cutting, sanding or sand blasting..1 Test results of suspected lead based paint and materials collected from the painted surfaces within the building are located at the end of this section. Copies of the laboratory analysis are included in Annex A. These are for general information only and are not representative of all the painted surfaces or paint coats contained within the scope of the proposed project..2 Three (3) paint samples were collected from the areas surveyed. Test results revealed that the samples analysed contain levels of lead below the regulated concentration of 5000 ppm (ug/g)..3 Based on the historic use of lead in building construction, lead is also presumed to be present in the solder joints on copper plumbing and drainpipe joint caulking throughout work area. Table 1 Summary of paint sample collected and laboratory analysis Location Description Sample Number Lead Concentration (ppm) Interior wall, on ply-wood between canvas doors Grey P1 84 On metal beams at floor and ceiling adjacent to canvas doors Red P2 2260 Exterior wall, on ply-wood between canvas doors White P3 39.9 MERCURY: Not identified.10 SILICA: Identified Based on the history of the composition of building materials, crystalline silica is expected to be present in the following building materials as part of the scope of this project:.1 Concrete and cement;.2 Masonry blocks and mortar..11 VINYL CHLORIDE: Not Identified.12 POLYCHLORINATED BIPHENYLS (PCBs): Not identified.13 OZONE DEPLETING SUBSTANCES (ODS): Not Identified

Replacement of Hangers Doors Ottawa, Ontario Page 4 of 4 2.2 RECOMMENDATIONS.1 LEAD Ontario Ministry of Labour draft Proposed Lead Regulation on Construction Projects, made under the Occupational Health and Safety Act, May 5, 1995, states that the removal of lead paint is not required unless work on these materials are likely to produce airborne lead dust or fumes (i.e. from welding, torch cutting, sanding and sand blasting). If these operations are likely to occur during renovation or demolition projects, the removal of lead-based paint will be required in accordance with the procedures outlined in the proposed regulation as well as outlined under Ontario Regulation 843/90 as amended by O. Reg. 519/92, O. Reg. 389/00 and O. Reg. 109/04.2 SILICA PART 3 CONTRACTOR DUTIES Silica occurs naturally as crystalline material in cement. Crystalline silica is significantly more toxic than amorphous silica, therefore for health reasons; only crystalline varieties are regulated under O. Reg. 845/90 as amended by O. Reg. 111/04 of the Occupational Health and Safety Act. Silica dust can be generated through such processes as blasting, grinding, crushing and sandblasting silica-containing material identified in Section 2.1.10. Therefore, appropriate respiratory protection, and ventilation must be utilized during the demolition and modification of these structures. The MOL s document Guideline Silica on Construction Projects has become an industry standard for protecting workers from silica exposure. This document outlines method for controlling silica hazard and offers classification criteria and measures and procedures for different types of operations..1 The contractor must review the designated substance report and take the necessary precautions to protect the health and safety of the workers and the environment. As per s.30 (4) of the Ontario Occupational Health and Safety Act, the party hiring the contractor (i.e. the Engineer) shall ensure that the contractor and subcontractor (if any) for the project has received a copy of the designated substance report prior to entering a binding contract for the supply of work on the project. As per s. 27 (2) (a,b,c) of the Ontario Occupational Health and Safety Act and s. 124 of Canada Labour Code, Part II, while on site, the contractor supervisor shall take every reasonable precaution in the protection of a worker. If you have any questions about the designated substance report, please contact the Engineer..2 If potentially hazardous materials are identified that are not identified in the survey, work should stop immediately until the materials are sampled to properly identify them and determine their means of disposal. PART 4 - EXECUTION Not Applicable ****************END OF SECTION***************

Replacement of Hanger Doors Ottawa, Ontario ANNEX A LEAD PAINT ANALYSIS RESULTS

Certificate of Analysis Levac Robichaud Leclerc Associates 1-2884 Chamberland St. Rockland, ON K4K1M6 Attn: Jessica Arthurs Phone: (613) 446-7777 Fax: (613) 446-1427 Client PO: Project: K11021 Custody: 1429 Report Date: 13-Jan-2012 Order Date: 12-Jan-2012 This Certificate of Analysis contains analytical data applicable to the following samples submitted: Paracel ID Client ID 1202145-01 P1 1202145-02 P2 1202145-03 P3 Order #: 1202145 Approved B Mark Foto, M.Sc. For Dale Robertson, BSc Laboratory Director Any use of these results implies your agreement that our total liabilty in connection with this work, however arising shall be limited to the amount paid by you for this work, and that our employees or agents shall not under circumstances be liable to you in connection with this work Page 1 of 3

Certificate of Analysis Client: Levac Robichaud Leclerc Associates Order #: 1202145 Report Date: 13-Jan-2012 Order Date:12-Jan-2012 Client PO: Project Description: K11021 Analysis Summary Table Analysis Method Reference/Description Extraction Date Analysis Date Metals EPA 6020 - Digestion, ICP-MS 13-Jan-12 13-Jan-12 Sample Data Revisions None Work Order Revisions / Comments : None Other Report Notes : n/a: not applicable MDL: Method Detection Limit Source Result: Data used as source for matrix and duplicate samples %REC: Percent recovery. RPD: Relative percent difference. Page 2 of 3

Certificate of Analysis Client: Levac Robichaud Leclerc Associates Client PO: Project Description: K11021 Sample Results Lead Order #: 1202145 Report Date: 13-Jan-2012 Order Date:12-Jan-2012 Matrix: Paint Sample Date: 12-Jan-12 Paracel ID Client ID Units MDL Result 1202145-01 P1 ug/g 5 84 1202145-02 P2 ug/g 5 2260 1202145-03 P3 ug/g 5 39 Laboratory Internal QA/QC Analyte Result Reporting Limit Units Source Result Matrix Blank Lead ND 5 ug/g Matrix Duplicate Lead 278 5 ug/g 292 4.8 50 Matrix Spike Lead 60.3 ug/l 11.7 97.2 70-130 %REC %REC Limit RPD RPD Limit Notes Page 3 of 3