Red Dot. Rigid Fittings. Table of Contents

Similar documents
(For Vertical Conduit) ENY-2 (Fixture Hanger) (See Page L146) (Drain/Seal for Vertical Conduit)

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

I-2 Unions, Sealing Fittings, Flexible Couplings, Elbows, Drain/Breather, Close-Up Plugs: Explosionproof UNILETS for Use with Threaded Metal Conduit

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

GLENWOOD PLACE 2 MAR 2015

Design Standard Conduit for Electrical Systems

Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit

SECTION RACEWAYS

SECTION OUTLET, PULL, AND JUNCTION BOXES

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

Specifications Electrical Metallic Tubing (EMT)

Material/Finish Aluminum Copper-free aluminum (less than 4/10 of 1%) Electrostatically applied powder coating

Raceway and Boxes for Electrical Systems Page 1 of 7

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

SECTION RACEWAYS AND BOXES

Mogul Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

Features: Single-Gang Two-Gang Three-Gang Four-Gang Hubless Receptacles. Compliance: CSA Listed. B Index. February Master Index. Cat. No.

Youngstown State University

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Scepter PVC Molded Junction Boxes

Student Services & Classroom Addition

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

TUFF-SEAL RSR SERIES ALUMINUM CORD GRIPS. Toll Free Fax RSR Series Straight Aluminum Cord Grips G 1

SECTION CONDUITS AND BOXES

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

ALUMINUM OR IRON CONDUIT BODIES

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

Service Entrance Cable Fittings

ALUMINUM OR MALLEABLE IRON CONDUIT BODIES

Section 2 Index PAGE 2-I. Metal Sheath and Ceramic Thermocouple Assemblies. AccuTru Sensor Technologies 2-1. Spring Loaded Hex Nipple w/ Head 2-2

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

SECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.

A. Coordinate arrangement, mounting, and support of electrical equipment:

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

IRON CONDUIT BODIES 5-5/16 (135) 6-9/16 (167) 7-9/16 (192) 8-7/16 (214) 10-3/8 (264) 12-3/8 (314) 15-5/8 (397) 15-5/8 (397)

Steel Octagon Boxes & Ceiling Pans

Flush Service Floor Boxes

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

Procurement Services SVC East Fowler Avenue Tampa, Florida (813)

SECTION RACEWAYS AND BOXES

TUFF-SEAL RSF SERIES ALUMINUM CORD GRIPS. Toll Free Fax RSF Series Aluminum Flat Cable Cord Grips G 16

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

CONDUIT ACCESSORIES AND FIXINGS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION CONDUIT AND FITTINGS

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS

Thermal Solutions Worldwide SECTION C. Industrial Thermocouples and RTDs. Straight Thermocouples Assemblies with Metal Protection Tubes C-5

GUC LNG Facility Phase IIB Expansion 6/20/14 INSTRUMENTATION SPECIFICATION. A. This Section includes instrumentation for process piping systems.

TUFF-SEAL RSSS SERIES STAINLESS STEEL CORD GRIPS. Toll Free Fax

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION RACEWAYS AND BOXES FOR ELECTRONIC SAFETY AND SECURITY

EXBLT Series for Harsh and Hazardous Environments

Myers Hubs. Applications: Features: Standard Materials: Certifications and Compliances: Standard Finishes: Options: Conduit Hubs.

ELECTRICAL SECTION 2

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SECTION BASIC FIRE SUPPRESSION MATERIALS AND METHODS. A. Section includes pipe, fittings, valves, and connections for sprinkler systems.

Flextray - Accessories

SECTION ELECTRICAL SYSTEM RACEWAY and BOXES

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Com-Tray. Under Floor

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

Raceway Solutions TM. Conventional Underfloor Duct. Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS. A. ANSI C Electrical Rigid Steel Conduit, Zinc Coated.

Standard Tube & Pipe Adapters


ADDENDUM 2. Lockwood Hall Renovation Project. July 9, The bidders are to take notice and acknowledge the following:

5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE

Kaf-Tech Product Specification

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

1. Hangers and supports for electrical equipment and systems.

Bore-Gard. Boreable Multi-Gard Assembly Multi-Gard Trenchless Raceway

Duct Wrap Flexible Wraps

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

AccuTru ExL High Temperature Thermocouples

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0528 Pathways. Page 1 of 6

BASIC ELECTRICAL MATERIALS AND METHODS

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

SECTION ELECTRICAL MATERIALS AND METHODS

Concrete Framing Systems - Walls and Columns

UNDERGROUND SERVICES SECONDARY

Transcription:

Table of Contents Conduit Unions Hazardous Locations... C2 C3 Conduit Fittings Hazardous Locations... C4 C5 Sealing Fittings Hazardous Locations... C6 C7 Conduit Hubs Raintight for Threaded Rigid Conduits... C8 C9 Concrete Slab Inserts... C10 C11 C1

Conduit Unions Hazardous Locations Applications Unions are used as connecting elements between enclosures, fittings or boxes which permitfuture changes to the system in both hazardous and non-hazardous areas. Features/Benefits Copper-free (less than.004 copper content) aluminum provides increased corrosion resistance Precision cast and machined surfaces permit safer wire pulling Precision NPT threaded hubs allow trouble-free field installation for rigid or IMC conduit Clear UL, CSA and cubic content markings speed approval by inspectors Unique concentric ring design insures critical flame path control Standard Materials Die cast aluminum alloy A360 (less than 0.004 copper content) EXMU nipples are galvanized steel Standard Finish Aluminum lacquer finish Compliances Compliances as noted on each page of the catalogue include: CSA Certified UL Listed Class I, Div. 1 and 2, Groups C, D Explosionproof Class II,Div. 1, Groups E, F, G Dust-Ignitionproof Class III, Div. 1 and 2 Raintight NEMA 3, 4, 7 CD, 9 EFG Wet Locations Smooth conduit stops Precision machined threads Unique concentric ring design Copper-free aluminum (less than 0.004 copper content) C2

Conduit Unions Hazardous Locations Male and Female Conduit Unions A B C Female to Female Union (Cast Aluminum) EXFU-1 1/2 EXFU-2 3/4 1-3/4 1-9/32 1-15/16 EXFU-3 1 2 1-19/32 2-3/16 EXFU-4 1-1-7/8 2-3/4 EXFU-5 1-1/2 2-2-5/32 3 EXFU-6 2 2-21/32 3-1/2 EXFU-7 2-1/2 3-3/16 3-3/16 4- EXFU-8 3 3-3-15/16 5 EXFU-9 3-1/2 3-1/2 4-17/32 5-5/8 EXFU-10 4 3-5/8 5-1/8 6-9/32 A B C D Female to Female Union (Cast Aluminum) EXMU-1 1/2 2-15/32 1-3/4 1-9/32 1-15/16 EXMU-2 3/4 2-9/16 EXMU-3 1 2 1-19/32 2-3/16 2-11/16 C3

Conduit Unions Hazardous Locations Applications Junction for branch conduits Accessible wiring chamber provides a convenient location to pull conductors Features/Benefits Copper-free (less than.004 copper content) aluminum provides increased corrosion resistance Precision cast and machined surfaces permit safer wire pulling Precision NPT threaded hubs allow trouble-free field installation for rigid or IMC conduit Deep slotted cover screws for faster installation Clear UL, CSA and cubic content markings speed approval by inspectors Standard Materials Die cast aluminum alloy A360 (less than 0.004 copper content) Standard Finish Aluminum lacquer finish Compliances Compliances as noted on each page of the catalogue include: CSA Certified UL Listed Class I, Div. 1 and 2, Groups C, D Explosionproof Class II,Div. 1, Groups E, F, G Dust-Ignitionproof Class III, Div. 1 and 2 Raintight NEMA 3, 4, 7 CD, 9 EFG Wet Locations Precision machined threads and surfaces Heavy wall construction Deep slotted screws Smooth conduit stops Copper-free aluminum (less than 0.004 copper content) C4

Conduit Unions Hazardous Locations Conduit Elbows and Capped Elbows A B C D E LB Style Conduit Body (Cast Aluminum) EXLB-1 1/2 4-3/16 3-1-3/4 1-11/16 1-9/32 EXLB-2 3/4 4-5/8 3-5/8 1-15/16 1-13/16 EXLB-3 1 5-3/8 4-1/2 2-5/16 2-1/32 2-3/16 A B C D E F T Style Conduit (Cast Aluminum) EXLB-1 1/2 4-1-3/8 2-1/8 1/2 1-11/16 1-1/16 EXLB-2 3/4 4-3/4 1-1/2 2-3/8 9/16 1-13/16 1-1/32 EXLB-3 1 5-1/2 1-7/8 2-11/16 7/16 2-3/16 7/16 A B C Capped Elbow Female to Female (Cast Aluminum) GYF-1 1/2 1-13/16 1-1/8 2 GYF-2 3/4 2-9/32 1-9/16 2-7/16 GYF-3 1 C5

Sealing Fittings Hazardous Locations Applications: Limits flames and/or explosions to area within electrical system where they originate Limits pressure piling Required for conduit systems in hazardous locations 18 in. from an enclosure housing a heat producing or arcing device; on 2 in. and larger system which enters an enclosure containing splices; wherever conduit leaves a Class I, Division I area and enters a non-hazardous area Features/Benefits: Copper-free (less than 0.004 copper content) aluminum provides increased corrosion resistance Precision cast and machined surfaces permit safer wire pulling Precision NPT threaded hubs allow trouble-free field installation for rigid or IMC conduit Large opening provides maximum working room for creating dam and seal pouring to speed up installation Compact design permits close construction of parallel conduit runs Standard Materials: Sealing Fittings: Die cast aluminum alloy A360 (less than 0.004 copper content) Sealing Cement Fiber: Flame retardant Kaowool Type A fiber Standard Finish: Aluminum lacquer finish Compliances: Compliances as noted on each page of the catalogue include: CSA Certified UL Listed Class I, Div. 1 and 2, Groups C, D Explosionproof Class II,Div. 1, Groups E, F, G Dust-Ignitionproof Class III, Div. 1 and 2 Raintight NEMA 3, 4, 7 CD, 9 EFG Wet Locations Smooth conduit stops Copper-free aluminum (less than 0.004 copper content) Large aperture for easy installation Precision machined threads C6

Sealing Fittings Hazardous Locations Cement Qty Fiber Qty A B C D Vertical Sealing Fittings (Cast Aluminum) EYVF-1* 1/2 2-3/4 1-3/16 1/2 1-5/16 EYVF-2* 3/4 2-7/8 1-3/8 2-13/16 EYVF-3* 1 3-7/16 1-5/8 1-9/16 3-5/16 EYVF-11 ф 1/2 2 oz. 1/32 oz. 2-3/4 1-3/16 1/2 1-5/16 EYVF-22 ф 3/4 3 oz. 1/16 oz. 2-7/8 1-3/8 2-13/16 EYVF-33 ф 1 4 oz. 1/8 oz. 3-7/16 1-5/8 1-9/16 3-5/16 * Packaged with an adequate amount of sealing compound close-up plugs installed. ф Approximate amount of cement and fiber required in oz. per hub EVHF-1 through 3 EVHF-4 through 6 Cement Qty Fiber Qty A B C D Vertical / Horizontal Sealing (Cast Aluminum) EVHF-1 ф 1/2 2 oz. 4-1/32 1-5/32 1-7/8 1/32 oz. EVHF-2 ф 3/4 3 oz. 4-3/32 1-3/8 1-1/64 2-3/32 EVHF-3 ф 1 4 oz. 4-3/8 13-9/64 2-5/16 oz. EVHF-4 ф 1-4 oz. 2-1/16 2-7/8 EVHF-5 ф 1-1/2 6 oz. 1/2 oz. 5 2-7/16 1-1/8 3- EVHF-6 ф 2 12 oz. 1 oz. 2-15/16 3-3/4 ф Approximate amount of cement and fiber required in oz. per hub Quantity Volume (Cu. in.) Sealing Cement EXSC-2 3.2 oz. 2 oz. EXSC-8 13 oz. 3 oz. EXSC-16 1 lb, 10 oz. 4 oz. Packing Fiber EXPF-16 CSA not applicable Quantity 1 lb C7

Conduit Hubs Raintight for Threaded Rigid Metal Conduits Applications: A fitting for connecting junction box to junction box, or junction box to the conduit system. The resulting connection maintaining ground continuity is raintight. Suitable for use where the system is normally hosed down (NEMA 4) for cleaning Features/Benefits: Plastic insulated throat, precision cast and machined surfaces permit safer wire pulling Special flush locking nipple design provides maximum space for wiring in the box Captive O-Ring fits snugly in groove preventing loss and fumbling with parts Knurled inner face of locking nipple provides 360 degrees of locking and bites through box paint to ensure grounding Locking nipple has tightening lugs on two planes for easier assembly in hard to reach field conditions Grounding hubs have a ground screw located within the enclosure providing a tamper-proof ground for device Locking nipple design permits replacement of the box without disassembling the installation Standard Materials: HTZ Series: Certified die cast zinc alloy ZAMAK 3 HT Series: Die cast aluminum alloy A360 (less than 0.004 copper content) Standard Finish: Aluminum lacquer finish Compliances: Compliances as noted on each page of the catalogue include: CSA Certified UL Listed Class I, Div. 1 and 2, Groups C, D Explosionproof Class II,Div. 1, Groups E, F, G Dust-Ignitionproof Class III, Div. 1 and 2 Raintight NEMA 3, 4, 7 CD, 9 EFG Wet Locations Smooth conduit stops Plastic insulated throat Precision machined threads Knurled teeth bite box Captive O-ring Convenient ground screw option Space saving design C8

Conduit Hubs Raintight for Threaded Rigid Metal Conduits Mntg. Hole (Thread) NPT A B C D Panel Thickness E F G Min. G Max. J O-Ring Size Insulated Throat (Cast Zinc) HTZ1 1/2 1-3/8 1-13/32 1/2 14 55/64 59/64 214 3/16 HTZ2 3/4 1-21/32 3/4 14 1-3/32 1-11/64 218 HTZ3 1 1-19/32 1-7/8 1 11-1/2 1-5/16 1-27/64 222 60 HTZ4 1-1-23/32 2-5/16 1-, 11-1/2 1-43/64 1-51/64 225 HTZ5 1-1/2 1-3/4 2-5/8 1-1/2, 11-1/2 1-29/32 2-13/64 227 HTZ6 2 1-25/32 3-5/32 2 11-1/2 2-3/8 2-21/32 231 HTZ7 2-1/2 2-2-45/64 2-1/2, 8 2-7/8 3-5/32 236 HTZ8 3 2-21/64 4-5/16 3 8 3-1/2 3-49/64 241 3/8 45 HTZ9 3-1/2 2-23/64 4-13/16 3-1/2, 8 4 4-7/16 245 HTZ10 4 2-3/8 5-5/16 4 8 4-1/2 4-63/64 248 A B C D Panel Thickness E F G Min. G Max. J O-Ring Size Insulated Throat and Ground Screw (Cast Zinc) HTGZ1 1/2 1-3/8 1-13/32 1/2 14 55/64 59/64 214 3/16 HTGZ2 3/4 1-21/32 3/4 14 1-3/32 1-11/64 218 HTGZ3 1 1-19/32 1-7/8 1 11-1/2 1-5/16 1-27/64 222 60 HTGZ4 1-1-23/32 2-5/16 1-, 11-1/2 1-43/64 1-51/64 225 HTGZ5 1-1/2 1-3/4 2-5/8 1-1/2, 11-1/2 1-29/32 2-13/64 227 HTGZ6 2 1-25/32 3-5/32 2 11-1/2 2-3/8 2-21/32 231 HTGZ7 2-1/2 2-2-45/64 2-1/2, 8 2-7/8 3-5/32 236 3/8 45 HTGZ8 3 2-21/64 4-5/16 3 8 3-1/2 3-49/64 241 A B C D Panel Thickness E F G Min. G Max. J O-Ring Size Insulated Throat (Cast Aluminum) HT1 1/2 1-13/32 1/2 14 55/64 59/64 214 1-3/8 3/16 HT2 3/4 1-21/32 3/4 14 1-3/32 1-11/64 218 HT3 1 1-19/32 1-7/8 1 11-1/2 1-5/16 1-27/64 222 60 HT4 1-1-23/32 2-5/16 1-, 11-1/2 1-43/64 1-51/64 225 HT5 1-1/2 1-3/4 2-5/8 1-1/2, 11-1/2 1-29/32 2-13/64 227 HT6 2 1-25/32 3-5/32 2 11-1/2 2-3/8 2-21/32 231 HT7 2-1/2 2-2-45/64 2-1/2, 8 2-7/8 3-5/32 236 HT8 3 2-21/64 4-5/16 3 8 3-1/2 3-49/64 241 3/8 45 HT9 3-1/2 2-23/64 4-13/16 3-1/2, 8 4 4-7/16 245 HT10 4 2-3/8 5-5/16 4 8 4-1/2 4-63/64 248 C9

Concrete Slab Inserts Applications: Permits in-slab ceiling drops and floor mounts in poured concrete Provides flush threaded conduit hub for mounting, pulling and future access to conduit systems Design permits prefabrication of in-slab conduit system Features/Benefits: Flush design leaves no broken or bent stubs for easy removal of undamaged forms Flush design permits simplified in-slab work Flush design leaves a neat, uncluttered job Offered in straight ES configuration for straight through conduit runs and mounting of floor boxes in slabs over 6 in. thick Offered in ESL configuration to eliminate bending of conduit in slabs over 4 in. thick Precision cast and machined surfaces permit safer wire pulling ZAMAK 3 Zinc can be embedded in concrete Standard Materials: Die cast zinc alloy ZAMAK 3. Certified by the Certified Zinc Alloy Plan (CZAP) Standard Finish: Natural Compliances: Compliances as noted on each page of the catalogue include: CSA Certified UL Listed Old Way Conduit running in a cement slab is bent 90º to run through a hole drilled in the form. Drilling takes time and damages the form. Stripping form often damages conduit stubs. Varying length of stubs requires individual measuring and cutting of conduit drops. Red Dot Way ESL 4" Slab Conduit running in a cement slab is attached to a 90º concrete slab insert, or conduit is bent 90º and is threaded to a straight insert. Nail or screw fitting to wood or metal forms. After concrete is poured and forms stripped, conduit drops quickly into fittings. Drops are easily measured from ceiling line to switch or outlet height and cut in uniform lengths. 6" Slab ES C10

Concrete Slab Inserts Concrete Tight Conduit Inserts A B C D E Straight Conduit Inserts (Zinc) ES-1 1/2 1-59/64 1-9/16 1-23/32 1-1/32 ES-2 3/4 2-11/64 1-5/8 1-31/32 1- ES-3 1 2-9/16 2 2-5/16 1-17/32 A B C D E F G 90º Angle Conduit Inserts (Zinc) ESL-1 1/2 4-27/32 3-45/64 3-29/32 3-3/16 1-7/8 1-1/32 ESL-2 3/4 5-11/64 3-23/32 4-1/8 4-1/8 2-1/8 1- ESL-3 1 5-5/32 3-3/4 3-15/16 3-15/16 2-7/16 1-17/32 C11

C12