Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Similar documents
TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

TRICOR Series TCM Coriolis Mass Flow Meters

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet

CLASSIC Series TRICOR Coriolis Mass Flow Meters

CLASSIC Series TRICOR Coriolis Mass Flow Meters

Quality Management (QM)

Quality Management (QM)

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Field case for temperature transmitter Model TIF11

Coriolis Mass Flow Meter

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

Turbine Meter. P e

Continuous Level Sensor CONDURIX 31.1

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Dense Medium Controller Specification (F revision 1.2)

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Coriolis Mass Flow Measurement System promass 63

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

SITRANS P measuring instruments for pressure

Degassed Cation Conductivity

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

OPTIMASS 7400 Technical Datasheet

makes sense! CO2 Sensor CO 2 in-situ measurement BlueSens.com

TURBINE METER RQ Series 1 and 2

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

602VFM MULTIVARIABLE VORTEX MASS FLOWMETER

Micro Motion TA-Series Flow and Density Meters

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

PanaFlow MV82. Insertion Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

FLOMID FX Electromagnetic Flowmeter

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Flow measurement of Liquids and Gases

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

602VFM MULTIVARIABLE VORTEX MASS FLOWMETER

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Micro Motion LNG Series Meters

Thermocouple for Flue Gas Temperature Measurements,

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

CALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

Presented By. NicolScales.com Contact Us

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

LIQUID METER TYPE FMO

SECTION Inline ULTRASONIC FLOW METERS

Presented By. NicolScales.com Contact Us

Pressure transducers DMU 02 Vario (flush)

Welding Force Calibration Transmitter

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

Drinking Water Monitoring. Ready-to-use systems for monitoring of quality relevant parameters in

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

Diaphragm pressure gauge

CIRRUS MAGNETIC FLOW METER CLA1-MF

SENSOR MUT1000EL. Electromagnetic flowmeter. The wafer electromagnetic flowmeter DS120-2-ENG

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

COMPANY VARIABLE AREA FLOW METERS

F-2200 Series Steam Meter

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Glycerine filled Bourdon tube pressure gauges EN 837-1

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

OPTIMASS 7400 Technical Datasheet

Miniature I/P, E/P Transducer

Mechatronic pressure measurement. Applications. Special features. Description

Micro Motion Technical Overview and Specification Summary

Standard Bourdon tube pressure gauges EN 837-1

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

VLM10 In-line Vortex Mass Flow Meter

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY IECEx BKI Page 1 of 8

RHM 100. Coriolis Mass Flowmeter for High Flow Applications. Applications. Features. Advantages

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

BOD 21M Distance Sensors. Effortless performance High efficiency

DVH. Multivariable Vortex Flowmeter

ABB MEASUREMENT & ANALYTICS DATA SHEET. SCK Sampling system for dry gas sampling at rotary cement kiln gas exit and calciner gas exit

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / /

CombiTemp TCR6 Standard RTD temperature sensor

Transcription:

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Description The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different measuring instruments. Due to a construction free of dead spots the meters are well flushable and can be easily sterilized. The Tricor Mass Flow Meters do not contain any moving parts and consequently are suited for polluted media as well. According to the requirements the Tricor Mass Flow Meters are available as compact version with on site display and remote version with electronis in a wall mount or panel mount housing. For the compact version an additional remote display (TRD 8001) is available, designed for cable lengths up to 1 km. Principle Two parallel flow tubes inside the TCM Flow Meter are vibrating at their resonant frequency in opposite direction. Any mass flow passing through the tubes will delay the vibration at the incoming side and accelerate the vibration at the outgoing side. This causes a small time delay between both ends of the tube. This time delay is measured and used to calculate the mass flow through the tubes. By measuring the resonant frequency of the tubes the mass of the medium and - given a constant volume inside the tubes - the density of the medium can be calculated. As both effects are temperature dependent, the temperature is measured via a precise sensor for correcting the temperature effects of flow and density measurement. As a consequence a Tricor Mass Flow Meter directly measures mass flow, density and temperature of the medium. Knowing the mass flow and the specific cravity, also the volume flow can be calculated. Application Flow measurement of PU components and paints Flow measurement of aggressive and contaminated media Measurement of mass flow, density, temperature and volume flow Besonderheiten Pmax. 350 bar Short response time DKD calibration Excellent puring and sterilization qualities due to a construction free of dead spots Up to +150 C medium temperature Individual 8-point-calibration including report Ex protected as per ATEX and EMC tested Cycle of excursion (simplified) Rotation and deformation of two parallel looped pipes by the Coriolis force Fc. Movement to the inside no flow Movement to the inside with flow Movement to the ouside no flow Movement to the outside with flow 2

Overview Compact version Remote Display TRD 8001 Exd housing for wall-mounting (separated version, also with flange ends) Remote panel-mounted housing (separated version, also with flange ends) 3

Technical Data - TCM Transducer TCM7900 TCM28k TCM65k Max. flow (kg/h) 7900 28 800 65 000 Min. flow (kg/h) 79 288 650 Max. flow (lb/min) 209 1060 2390 Min. flow (lb/min) 2.90 10,6 23.90 Basic Accuracy (% of flow reading) 0.1 0.1 0.1 Zero Stability (% of full scale) 0.01 0.01 0.01 Zero Drift (% f.s. per C) 0.001 0.001 0.001 Repeatability (% of flow) 0.1 0.1 0.1 Density measuring range Density accuracy 0-4500 kg/m³ ± 0.002 kg/ltr Temperature accuracy ±1 C ±0.5% of reading Process and Ambient Process connections flanges EN1092, ANSI B16.5, DIN2512 Max. pressure 100 bar Max. pressure (Option) on request Pressure Drop at max. flow H 2 0 see diagramm Operating Density range 100-2500 kg/m³ (lower densities on request) Process temperature -20... +100 C (options: -100... 150 C) Ambient temperture -40... +100 C Storage temperature -40... +80 C Electr. connections remote screw type terminals Electr. connections compact. none (internally connected to the electronics) Ingress Protection IP67 General Tube arrangement 2 parallel 2 parallel 2 parallel tube inner diameter 12mm 18mm 34mm tube material ss 1.4404 / 1.4571 housing material stainless steel Dimensions see drawings 4

Technical Data - TCE 8000 Transmitter General Display: Supply votage: Programming: Interface: Graphic, 132 x 32 dot 24 VDC, ± 20% and / or 100-240 VAC (version dependent) via front keyboard RS 485, Option HART, option Foundation Fieldbus EMC: according to EN 61000-6-4 und 61000-6-2 Power consumption: Exd housing: Dimensions: max. 4 W see drawing Connections: internal clamp terminals cable gland for 7-13 mm cables Material: aluminium diecast Protection class IP 67 Weight: approx. 2 kg Temperature: operating: - 20 up to 70 C (up to + 80 C on request) storage and transport: -40 up to 80 C Panel-mounted housing: Dimensions: 96 x 96 x 83mm (h x w x d) Connections: rear clamp terminals Material: Noryl Protection class: front: IP 40, rear: IP 30 Weight: approx. 500g Temperature: operation: 0 to 60 C storage and transport: -20 up to 70 C Analog Outputs Two current outputs: Resolution: Linearity: Temperature drift: Load: Output value: Pulse Output Frequency range: Output signal: Status In-and Output Status output Control input 4-20 ma passive, two-wire, isolated 14 bit ± 0.05% of full scale 0.05% per 10K < 800 Ώ programmable: flow, total, density, temperature 0.5-10,000 Hz active push pull output for flow rate push pull programmable programmable 5

Technical Data - TRD 8001 Remote Display Display Supply voltage: Programming: Graphic, 132 x 32 dot via interface Interface to TCM: RS 485 via front keyboard EMC: according to EN 61000-6-4 und 61000-6-2 Dimensions: 90 x 120 x 50 mm3 (h x w x d) Connections: Material: connector M12, B coded ABS-FR Protection class: IP 64 Weight: approx. 500g Temperature: operation: 0 to 60 C storage and transport: -20 up to 80 C Wall mount ATEX IECEx hidden screws Zone 1: different versions Ex d or Ex i Zone 2: available in Preparation Accuracy % 1,5 1 0,5 Accuracy Basic Accuracy + Zero Stability max. Flow Current Flow 0-0,5-1 -1,5 0 10 20 30 40 50 60 70 80 90 100 Flow % 6

Dimensional drawing (mm) TCM 28k to TCM 65k M C H P S D N L B Sensor Type A B C H L* Connection** TCM 7900 197 61 204 260 460 a. N. TCM 28k 218 80 253 315 625 a. N. TCM 65k 360 151 387 480 830 a. N. * further lengths on request ** flange types on request Elektronic Type D M N P S - Housing C 110 205 118 188 218 - Housing E 130 240 111 217 243-7

Dimensional drawing (mm) TCE 80xx - W 8

Dimensional drawing (mm) TCE 80xx - E with cable connection 189 147 265 4x Ø 5,7 45 8 45 Ø 132 186 238 9

Dimensional drawing (mm) TCE 80xx - E with Junction Box 189 147 265 4x Ø 5,7 45 Ø 132 8 45 318 238 10

Dimensional drawing (mm) Panel-Mounted Housing (drawing not to scale) Type A B - - - - - TCE 80** - S 96 96 - - - - - TCE 80** - L 96 144 - - - - - Dimensional drawing (mm) Remote Display TRD 8001 90 16 48 A B 83 8 144 120 11

Contact KEM Headquarter Liebigstraße 5 85757 Karlsfeld Germany T. +49 8131 59391-0 F. +49 8131 92604 info@kem-kueppers.com KEM Service & Repairs Wettzeller Straße 22 93444 Bad Kötzting Germany T. +49 9941 9423-0 F. +49 9941 9423-23 info@kem-kueppers.com More distributors & partners can be found at: www.kem-kueppers.com Your local partner: www.kem-kueppers.com info@kem-kueppers.com KEM Küppers Elektromechanik GmbH Liebigstraße 5 D-85757 Karlsfeld Tel +49 8131 59391-0 Fax +49 8131 92604 Copyright KEM, Subject to change without notice, ES Rev. 009-16/06/2012