Accuracy and Precision. Dilution Error in Error in Factor Accuracy Precision 200 <2% <2%

Similar documents
ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems

Analysis of wear metals and contaminants in engine oils using the 4100 MP-AES

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Increase productivity for environmental sample analysis using the SVS 2+ Switching Valve System for Agilent 5100 SVDV ICP-OES

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II AA Mercury Analyzer

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Guidelines for Troubleshooting and Maintenance of AA Systems

Analysis of Heavy Metals in Iron-based Fertilizers by HR ICP-OES

Functionality. Normal Operation

Evaluation of the Mercury Concentration Accessory for US EPA Methodology

NanoLC-Ultra system. data sheet. Introducing the NanoLC-Ultra family of high pressure HPLCs for proteomics research

ICP Expert software. Technical Overview. Introduction

Optima 8x00 Series. ICP Optical Emission Spectrometers

Composition Analysis of Animal Feed by HR ICP-OES

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

PinAAcle 500. Flame Atomic Absorption Spectrometer

USABILITY BY DESIGN Every component of the Agilent 7900 ICP-MS is engineered for performance and reliability

Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology

Agilent 7900 ICP-MS RAISE YOUR EXPECTATIONS WITH THE NEXT GENERATION OF ICP-MS

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Fields of Application / Industry:

Agilent 7900 ICP-MS RAISE YOUR EXPECTATIONS WITH THE NEXT GENERATION OF ICP-MS

PinAAcle 900 Series. Atomic Absorption Spectrometers

Automating EPA 6020 Compliant Analysis with the Agilent 7900 ICP-MS and ESI prepfast Autodilution System

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Introducing the new Agilent 7800 Solution-Ready ICP- MS. Agilent Technologies 2015

Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces

The CDS 7000 E Purge & Trap Concentrator

EXPAND YOUR RANGE EXTEND YOUR RESOURCES. Avio 500 ICP Optical Emission Spectrometer

Analysis of Toxic Trace Elements in Coffee Bean Products by HR ICP-OES

Optima 8x00 Series. ICP Optical Emission Spectrometers

Benefits of running organic matrices using the Agilent 5100 ICP-OES fast, robust, high performance analysis

Determination of 22 Elements Following US EPA Guidelines with a New Megapixel CCD ICP-OES

Amplifying ICPMS Productivity Using Discrete Sampling Technology

prepfast Autodilution Autocalibration Auto QC Dilution Elemental Scientific

Application Note. Abstract. Authors. Environmental

Microflow Liquid Chromatography Mass Spectrometry System. Nexera Mikros C146-E350

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

Agilent Atomic Spectroscopy Solutions for Energy & Chemicals AA, MP-AES, ICP-OES, ICP-MS.

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Maximizing Sample Recovery on the ACCQPrep HP125

Agilent SD-1 Purification System. Purify your way SD-1

Dynex DSX 4-Plate ELISA Processing System. Modular Flexible Reliable A Perfect Combination.

Multi-Element Analysis of Trace Metals in Animal Feed using ICP-OES

A Computer Controlled Multi-Analysis Titration System

Multidrop. The most precise and reliable reagent dispensing solution. Analyze Detect Measure Control TM

ultra why micro-lc? product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc

Cleaning Validation PRODUCT OVERVIEW

Preparative, Pilot & Process Columns

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Productive. Precise. Reliable. AGILENT ATOMIC ABSORPTION SPECTROMETERS

Flame Atomic Absorption Spectrometer (FAAS) Brand : PERKINALMER Model : PinAAcle 900T Custodian : PRADUP MESAWAT SOOKRUTHAI WONGSUBIN

PINAACLE 500/900 AA AND SUPPLIES CONSUMABLES. Consumables and Supplies Reference Guide

Tender Document. National Centre of Excellence in Analytical. Chemistry, University of Sindh, Jamshoro. Inductive Coupled Plasma (ICP -OES) ISSUED BY:

Avio 200 ICP-OES Flat Plate

TrueSense* for Cooling

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Solutions Guide. MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications

Product Descriptions and Offerings

Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES

Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES

Application Note PlasmaQuant PQ 9000 Elite. Analysis of Rare Earth Elements in Granite and Sandstone by HR ICP-OES. Challenge.

Soxtec TM 8000 Solvent Extraction Solution

Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION SPECTROMETERS

QbD1200 TOTAL ORGANIC CARBON ANALYZER RELIABLE MEASUREMENT MADE SIMPLE.

Agilent 7693A Series Automatic Liquid Sampler Inject new performance into your gas chromatography. Our measure is your success.

Sievers M9 TOC Analyzers

Soxtec TM 8000 Solvent Extraction Solution

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

How do you maximize purity and yield? 2 Continuous counter-current chromatography

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Atomic Absorption Spectrometry. Quality is the Difference novaa

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

Greater efficiency through on-demand paste production

Hichrom Limited 1 The Markham Centre, Station Road, Theale, Reading, Berkshire, RG7 4PE, UK Tel: +44 (0) Fax: +44 (0)

Soxtec/Hydrotec TM 8000 Total Fat Solution

RELIANCE HIGH THROUGHPUT AUTOSAMPLER

Analysis of Environmental Samples with the Agilent 730-ES Following US EPA Guidelines

FMA-80 Fluorescence Mercury Analyzer

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

PLC Purification Systems

MAX300-BIO PRODUCT NOTE. Bioreactor/Fermentation Control Process Efficiency Product Quality Analysis. Bioreactor/Fermentation Mass Spectrometer

High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

Correlation coefficient

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Trace Elements in Petrochemical Samples: Achieving Excellent Analytical Results

Dynex DS2 2-Plate ELISA Processing System. Compact Easy to Use Innovative A Perfect Combination.

Quick Reference Guide. Supplies for CTC GC and HPLC Autosamplers

PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Dt of Revision : Issue Dt. :

Millennium Excalibur MEASUREMENTS OF ARSENIC, SELENIUM, ANTIMONY, BISMUTH AND TELLURIUM. with the accuracy of atomic fluorescence

Eco Plasma Innovative Inductively Coupled Plasma Technology

DuMaster D-480 Technical data sheet

Transcription:

Specifications SDS-270 Sample Options Three sample racks, containing: 3 x 60 position x 16 mm OD (20 ml) (default configuration) or optionally: 3 x 90 position x 13 mm OD (13 ml) 3 x 40 position x 20 mm OD (30 ml) 3 x 24 position x 25 mm OD (50 ml) 3 x 21 position x 30 mm OD (80 ml) Rack types can be mixed. Standards Capacity Ten position x 25.6 mm OD (50 ml) IO Ports Four programmable relays One multi-function IO port Two RS-232 ports Host Computer External PC (needs at least two RS232 ports). Software control from GBC AAS, Cintra UV-Vis, or ICP-OES software. Dimensions 405 x 375 x 390 (WxDxH, mm) Extended height 600 mm Weight Unpacked: 13 kg Electrical Requirements 100 260 volts ac, 47 440 Hz, 30 VA. PS-270 Accuracy and Precision Dilution Error in Error in Factor Accuracy Precision 50 <1% <1% 200 <2% <2% Syringe 10 ml and 25 ml capacity. Borosilicate glass barrel, stainless steel plunger, virgin PTFE seal. Speed Solution pick-up: 100 m L/sec to 10,000 m L/sec Solution dispersion rate: 100 m L/sec to 10,000 m L/sec Volume Transfer Range 10 ml syringe 20 m L to 10,000 m L 25 ml syringe 50 m L to 25,000 m L Plunger Drive Stepper motor driven leadscrew with optical feedback. High resolution 24,000 step drive. IO Port One serial RS-232C port. Host Computer External PC (needs at least two RS232 ports). Software control from GBC AAS software. Dimensions 220 x 170 x 320 mm (WxDxH) Weight Unpacked: 5.2 kg Electrical Requirements 100 260 volts AC, 47 440 Hz, 30 VA.. HSA3000 Pump Ten roller peristaltic Switching Valve Six port, four way Sample Loop Volume 100 m L nominal Power Requirements 110/220 Vac, 50/60 Hz Dimensions 300 x 200 x 370 (WxHxD, mm) Control System GBC AAS models: 932/933, Avanta, Avanta S Weight Unpacked 5 kg, packed 11 kg

Ordering Information SDS-270 Sample Delivery System SDS-270 99-0326-x1 x- varies with local voltage requirement. Consult your agent for the correct suffix. Sample Racks 90 positions 81-1111-00 60 positions 81-1112-00 40 positions 81-1113-00 24 positions 81-1114-00 21 positions 81-1115-00 Standards rack (10 positions) 81-1116-00 PS-270 Prep Station PS-270 99-3533-00 Syringe Kits 10 ml syringe 95-0385-00 25 ml syringe 95-0386-00 GBC Scientific Equipment Pty Ltd A.C.N. 005 472 686 GBC reserves the right to change specifications without prior notice. GBC publication number 01-0883-00 Jul 1998 Australia GBC Scientific Equipment Manufacturer of premier scientific instrumentation AAS, ICP-OES, ICP-MS, UV-VIS and HPLC 12 Monterey Road Dandenong, Victoria 3175 Australia Telephone 61 3 9213 3666 Facsimile 61 3 9213 3677 Internet http:/www.gbcsci.com Email gbc@gbcsci.com 3930 Ventura Drive Arlington Heights, IL 60004, USA Telephone (847) 506 1900 Toll Free 1800 445 1902 Facsimile (847) 506 1901 HSA3000 High Solids Analyzer HSA3000, 220 V 99-0155-00 HSA3000, 110 V 99-0155-01 Supplied complete with rinse bottle, all tubing, cables and spare pump tubing (four pieces) Pump tubing and capillary tubing replacement kit 95-0120-00

SDS-270 Sample Delivery System random access, fully automated sample handling for greater accuracy and productivity The manual preparation of samples and standards can be a time-consuming, errorprone and costly exercise. Boost the productivity of your laboratory and the accuracy of your analysis with these robust, simple-to-operate sampling accessories for your GBC AAS. All are controlled by software functions which form an integrated part of GBC s AAS software, using the versatile Windows 95 platform. Operation could not be simpler. Accuracy is guaranteed. And so is peace of mind. High capacity x,y,z autosampler The GBC Sample Delivery System 270 complements the range of GBC atomic absorption, ICP-OES and UV-Vis spectrometers. Samples are contained in three separate test tube racks, allowing different tube sizes within a batch. With a maximum capacity of 270 samples, extensive unattended operation is possible. You can use existing standard lab racks for additional versatility. Automated functions Analyze the sample you want, when you want to. GBC software provides for fully automated or true random access operation. The SDS-270 supports standard addition analysis for complex matrices, and also has a micro-sampling mode for analysis when low sample volume would normally preclude autosampling. Sample integrity Sample integrity is assured, with a chemically inert PTFE coated and lined stainless steel sampling probe. Sample carry-over is further minimised by the provision of an efficient continuous flow probe wash with a turbulent fast-flowing action.

PS-270 Sample Prep Station fully automated solution treatment for faster, more efficient analysis Fast and efficient pre-treatment The GBC Prep Station 270 offers simple, fast and efficient pre-treatment for samples, standards, diluents, modifiers and rinse solutions for all flame and hydride atomic absorption methods. Reduce the cost of analysis The true cost of analysis can be hidden in long analysis times, tedious standards preparation, matrix modification, sample dilution, and inaccuracies introduced by manual solutions handling. In combination with the SDS-270 autosampler, the GBC PS-270 provides an effective alternative to high laboratory costs and difficulties by automating standards preparation, matrix modification, spike recovery and sample dilution. Save time and simplify laboratory tasks The benefits of faster analysis, lower maintenance and more effective use of laboratory staff time are just the beginning. Avoid the problems of peristaltic pumpbased systems, with their inherent liabilities of tubing wear, mixing loops, dead time and solution carry-over. Improve turn-around time Minimizing the labour component of solution treatment before the presentation of samples to your AAS will boost the productivity and profitability of your laboratory. Enable the addition of up to two separate chemical modifier solutions These might be ionization suppressants, release agents, an acid, or an anti-foaming agent for hydride analysis. Prepare working standards and standard additions However many calibration standards or additions you choose, this system will guarantee accurate and reproducible calibrations every time. This includes all calibration standards for use in Automatic Burner Rotation methods. The software is written in such a way as to prepare only those calibration standards which are required by the method. You can present a commercially available 1000 mg/ml elemental standard as, unlike other systems, there is no need to prepare the bulk standard. Dilute samples before measurement Samples can be diluted before being measured for the first time. This is ideal for digested solutions. Simply specify a dilution factor and start the analysis. Automatically dilute over-range samples If a sample gives an absorbance greater than that of the calibration standards, the sample is automatically diluted. Simply specify a dilution factor for the overrange samples. Perform a spike recovery Automatically prepare spike recovery samples, used as a check for possible interferences. If the spiked sample fails a pre-determined recovery range then the analysis will proceed according to the procedure specified by the operator. Use ABR and auto-dilution for over-range samples Automated Burner Rotation (ABR) is a technique applied on GBC AAS systems to provide fast and accurate compensation for over-range samples, improving the measurement range by a factor of forty, without operator intervention. Automated on-line dilution extends the capability still further, offering the widest dynamic range available in AA spectroscopy today. Preference is given to Automatic Burner Rotation. However, if the sample is still over-range after the last calibration burner angle, the system can be set to automatically dilute the sample. Dynamic range is extended by at least two orders of magnitude and samples never need to be manually diluted or re-analyzed, providing substantial gains in productivity.

HSA3000 High Solids Analyzer fast and simple analysis of high salts and high solids solutions without dilution The analysis of samples with a high dissolved solids content has always been a problem in flame AAS. There is a strong tendency for salts to crystallize and cause blockages in the nebulizer or burner system. Historically, the only way to avoid this problem has been to dilute the sample until the concentration of dissolved salts is about 2% or less. This is a tedious and time consuming process. Sample dilution does not solve the problem if the analyte element is present at low concentrations. In this case, sample dilution could reduce the concentration of the analyte to below the detection limit. With the GBC HSA3000 High Solids Analyzer, all of these problems are solved, while retaining sensitivity. The HSA3000 can be fitted in a few moments to the sample compartment of any GBC AAS without using additional bench space. Choice of flame types The HSA3000 can be used for AA measurements with either air-acetylene or nitrous oxide-acetylene flames. Excellent reproducibility was obtained with samples of Ba in 30% NaCl solution using the nitrous oxide-acetylene flame. Analysis Filename C:\Program Files\GBC Avanta Ver 1.31\Analysis1.anl Element Ba, Date Mon Jun 22 15:23:57 1998 Full Calibration Calibration Mode Conc Least Squares Max Error : 0.119 R : 1.000 Full Calibration ------------------------------------------------------------------------------------------------ Sample Label Conc. %RSD Mean Replicates (µg/ml) Abs. ------------------------------------------------------------------------------------------------ Cal Blank ----- 0.00 0.0000 0.0000 0.0000 0.0000 Standard 1 5.000 1.95 0.0783 0.0800 0.0780 0.0770 Standard 2 10.000 3.26 0.1543 0.1550 0.1590 0.1490 Standard 3 15.000 1.61 0.2240 0.2280 0.2210 0.2230 Standard 4 20.000 1.39 0.2880 0.2880 0.2920 0.2840 Simple operation The HSA3000 introduces the sample to the AAS nebulizer by injecting a small amount of undiluted sample into a continuous flow of rinse solution. The rinse solution ensures that the nebulizer is continually washed, and that nebulizer and burner do not become blocked with salt. A transient peak is generated by the trapped sample, and measured using either peak height or peak area mode. The operator simply places the sample capillary tube in the sample and initiates the reading. The HSA3000 does the rest. Computer control and automation All functions of the HSA3000 are fully controlled from the AAS computer. Timer settings and control of the valve and pump are implemented by simple menu selections. The HSA3000 is compatible with all GBC AA spectrometers. Rapid sample throughput The typical cycle time is 45 50 seconds per sample, with two readings on each sample. Allowing for calibrations, this gives a throughput of 60 80 samples per hour. Outstanding performance With conventional AA analysis, the maximum concentration of dissolved solids which can be tolerated is about 2%. With the HSA3000 it is possible to work with salt concentrations as high as 30%. In the experiment shown below, the analysis of a sample of Cu in 30% NaCl solution was repeated 50 times. There was no change in absorbance over the 50 readings, and the precision over the entire run was 2.4%.