CTBUH Technical Paper

Similar documents
Cyclic Loading Tests Of Steel Dampers Utilizing Flexure-Analogy of Deformation

Seismic behaviour of HSC beam-column joints with high-yield strength steel reinforcement

Hybrid-steel concrete connections under reversed cyclic loadings

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

Original Publication: International Journal of High-Rise Buildings Volume 5 Number 3

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

CYCLIC BEHAVIOR OF AN INNOVATIVE STEEL SHEAR WALL SYSTEM

Improving Seismic Performance of Steel Knee Braced Frame Structures

ctbuh.org/papers CTBUH Recommendations for the Seismic Design of High-Rise Buildings

Experimental Evaluation of The Seismic Behavior of Steel- Braced RC Frames

Seismic Performance of Flange Plate Connections to Built-up Box Columns

Masonry infills with window openings and influence on reinforced concrete frame constructions

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

BRACED FRAME USING ASYMMETRICAL FRICTION CONNECTIONS (AFC)

The Structural Performance of RC Coupling Beam. Using Cold-Formed Steel Channel Sections for. Alternative Detail

SHEAR STRENGTH CAPACITY OF PRESTRESSED CONCRETE BEAM- COLUMN JOINT FOCUSING ON TENDON ANCHORAGE LOCATION

TESTS ON A POST TENSIONED MOMENT RESISTING CONNECTION FOR PRECAST CONCRETE STRUCTURES

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Hysteretic Characteristics of Braced Frames in Modular Steel Buildings

Seismic Behaviour Of A Soft Storey Building With & Without Viscous Dampers

SEISMIC PERFORMANCE OF SCBF BRACED FRAME GUSSET PLATE CONNECTIONS

SEISMIC RETROFITTING OF LOW-RISE NONDUCTILE REINFORCED CONCRETE BUILDINGS BY BUCKLING-RESTRAINED BRACES

USING ACCORDION THIN-WALLED TUBE AS A HYSTERETIC METALLIC DAMPER

Retrofitting methods

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

Seismic performance of RC frames with concentric internal steel bracing

SEISMIC DESIGN OF STRUCTURE

Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings

RETROFITTING METHOD OF EXISTING REINFORCED CONCRETE BUILDINGS USING ELASTO-PLASTIC STEEL DAMPERS

EXPERIMENTAL INVESTIGATION OF PRECAST CONCRETE BEAM TO COLUMN CONNECTIONS SUBJECTED TO REVERSED CYCLIC LOADS

Exploring the Implication of Multi-plastic Hinge Design Concept of Structural Walls in Dual Systems

EXPERIMENTAL RESULTS

Truss Analysis for Evaluating the Behavior of Reinforced Concrete Moment-Resisting Frames with Poorly Reinforcing Details

Dual earthquake resistant frames

Experimental research on reduced beam section to concrete-filled steel tubular column joints with RC slab

D. Y. Abebe 1, J. W. Kim 2, and J. H. Choi 3

Original Publication: International Journal of High-Rise Buildings Volume 4 Number 3

DE-BONDED DIAGONALLY REINFORCED BEAM FOR GOOD REPAIRABILITY

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Numerical study of shear wall behavior coupled with HPFRCC beam and diagonal reinforcements

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

Modeling of Shear Walls for Nonlinear and Pushover Analysis of Tall Buildings

In-plane testing of precast concrete wall panels with grouted sleeve

MODELLING OF SHEAR WALLS FOR NON-LINEAR AND PUSH OVER ANALYSIS OF TALL BUILDINGS

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

APPLICATIONS OF STRESS FIELDS TO ASSESS THE BEHAVIOR AND STRENGTH OF COUPLING BEAMS SUBJECTED TO SEISMIC ACTIONS

Aluminium Shear Yielding Damper (Al-SYD) as an Energy Dissipation Device in Truss Moment Frames (TMFs)

PERFORMANCE OF EXTERIOR PRECAST UNDER CYCLIC LOADING. R. Vidjeapriya & K.P. Jaya Anna University, Chennai , India 1.

Offering a step-change in seismic technology

Seismic Evaluation of Steel Moment Resisting Frame Buildings with Different Hysteresis and Stiffness Models

Research on Seismic Behavior of honeycomb composite beamcolumn

Southeast University, Nanjing, Jiangsu , China. *Corresponding author

CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN CONNECTIONS

Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting

DESIGN OF A SHEAR CONNECTOR FOR A NEW SELF-CENTERING WALL SYSTEM

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor

Shaking Table Model Test of a HWS Tall Building

STUDY ON SHEAR PANEL DAMPERS USING LOW YIELD STRENGTH STEEL APPLIED TO REINFORCED CONCRETE BUILDINGS

PEER Tall Building Seismic Design Guidelines

INELASTIC SEISMIC PERFORMANCE OF RC TALL PIERS WITH HOLLOW SECTION

SEISMIC BEHAVIOR OF RC COLUMNS WITH VARIOUS TIE CONFIGURATIONS

Determining the Optimum Slip Load of the Friction Damped Concentrically Braced Multi-Storey Timber Frame

Inelastic Behavior of Hollow Reinforced Concrete Bridge Columns

EARTHQUAKE-RESISTANT DESIGN OF RC FRAME WITH DUAL FUNCTIONS METALLIC DAMPERS

SEISMIC FORCE RESISTING MECHANISM OF THE MULTI-STORY PRECAST CONCRETE SHEAR WALL SUPPORTED ON PILES

A F.E.M. MODEL FOR THE EVALUATION OF THE SEISMIC BEHAVIOR OF INTERNAL JOINTS IN REINFORCED CONCRETE FRAMES.

Heriot-Watt University

IDEA OF HYBRID COLUMN WITH ENERGY ABSORPTION ELEMENT

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

Full-scale Testing of the Cast Steel Yielding Brace System

ABSTRACT. Keywords: Resilience, Public Apartment Buildings, Wing Wall, Performance-Based Design. 1. INTRODUCTION

Seismic Performance of Residential Buildings with Staggered Walls

Effect of beam dimensions on structural performance of wide beam-column joints

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

Lateral Force-Resisting Capacities of Reduced Web-Section Beams: FEM Simulations

Pushover Analysis of Reinforced Concrete Structures with Coupled Shear Wall and Moment Frame. *Yungon Kim 1)

Seismic Performance and Application of Sandwiched Buckling-Restrained Braces and Dual-Core Self-Centering Braces

Seismic behavior of concrete structures equipped with ADAS devices

Seismic Evaluation of the Historic East-Memorial Building Retrofitted with Friction Dampers, Ottawa, Canada

Comparing Seismic Parameters of SSW and Concentrically Braced Steel Frames (CBF) by ABAQUS Software

Research on the Seismic Performance of an Externally Prestressed Rocking Reinforced Concrete Frame

Seismic performance evaluation of tall and nonseismic-designed wall-type structures by shaking table tests

Behavior of Reinforced Concrete Walls with Mesh Reinforcement Subjected to Cyclic Loading

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

PLASTIC DEFORMATION CAPACITY AND HYSTERETIC BEHAVIOR OF U-SHAPED STEEL DAMPERS FOR SEISMIC ISOLATED-BUILDINGS UNDER DYNAMIC CYCLIC LOADINGS

PUSHOVER ANALYSIS (NON-LINEAR STATIC ANALYSIS) OF RC BUILDINGS USING SAP SOFTWARE

Ductile Design of Steel Structures

SEISMIC PERFORMANCE OF AAC INFILL AND BEARING WALLS WITH DIFFERENT REINFORCEMENT SOLUTIONS ANDREA PENNA

SEISMIC RESPONSE OF LINEAR, FLANGED, AND CONFINED MASONRY SHEAR WALLS

SEISMIC BEHAVIOR OF PRECAST REINFORCED CONCRETE WALLS

1844. Seismic evaluation of asymmetric wall systems using a modified three-dimensional capacity spectrum method

Effect of lintel on horizontal load-carrying capacity in post-beam structure

EFFECTS OF END REGION CONFINEMENT ON SEISMIC PERFORMANCE OF RC CANTILEVER WALLS

THE DESIGN AND INSTALLATION OF A FIVE-STORY NEW TIMBER BUILDING IN JAPAN

EXPERIMENTAL STUDY OF THE DEFORMATION CAPACITY OF STRUCTURAL MASONRY

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

EXPERIMENTAL STUDY ON HYSTERETIC DAMPER WITH LOW YIELD STRENGTH STEEL UNDER DYNAMIC LOADING

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

Ductile Fiber Reinforced Panels for Seismic Retrofit

Transcription:

CTBUH Technical Paper http://technicalpapers.ctbuh.org Subject: Paper Title: Structural Engineering Seismic Performance of Coupling Beam Damper System Author(s): Ahn, Taesang 1 Kim, YoungJu 1 Kim, SangDae 2 Hwang, Intae 2 Affiliation(s): 1 Dongil Rubber Belt (DRB) Co., Ltd. 2 Korea University, Seoul Publication Date: 211 Original Publication: CTBUH Conference, Seoul. October 1-12, 211 Paper Type: 1. Book chapter/part chapter 2. Journal paper 3. Conference proceeding 4. Unpublished conference paper 5. Magazine article 6. Unpublished Council on Tall Buildings and Urban Habitat/Author(s)

MS3-1 Seismic Performance of Coupling Beam Damper System TAESANG AHN 1, YOUNGJU KIM 2, SANGDAE KIM 3, INTAE HWANG 4 Dongil Rubber Belt (DRB) Co., Ltd., Seoul, Korea, ahn.tae.sang@drbworld.com 1 Dongil Rubber Belt (DRB) Co., Ltd., Seoul, Korea, kim.young.ju@drbworld.com 2 Korea University, Seoul, Korea, sdk@korea.ac.kr 3 Korea University, Seoul, Korea, jegal2@lycos.co.kr 4 TAESANG AHN Biography Tae-sang AHN has a bachelor's degree in architectural engineering and a master's degree in building construction from Seoul National University of Science and Technology. And he is pursuing a doctorate in building construction at the KOREA University. Tae-sang AHN got a certification for structural engineer in 22. And he worked the company of structural design for 12years. Now he is a director of research in seismic isolation and vibration control engineering center from 27. Abstract This paper describes an experimental investigation on the hysteresis behavior of new type of reinforced concrete coupling beam systems with energy dissipation devices, such as a steel damper and a friction damper. The coupling beam considered in this research is located between shear walls. The new system offers important advantages over the conventional systems: simpler detailing for the beams and the walls; increasing energy dissipative capacity, reducing damage to the structure. Metallic damper or friction damper are installed within beam to provide energy dissipation. Under lateral load, damper is in shear or bending. Test programs are carried out to investigate the hysteresis behavior and to evaluate the energy dissipation capacity. Test results show that the proposed systems show an excellent hysteretic behavior. In addition, the energy dissipation in these systems is concentrated only at the energy dissipation devices, while the inelastic behavior of the beams and walls is prevented through appropriate capacity design. Keywords: Coupling beam, Energy dissipation devices, Hysteresis behavior, Energy dissipation capacity 71

1. INTRODUCTION The behavior of coupled shear walls is influenced by the stiffness, strength and ductility of coupling beams. Paulay (1971) showed that the failure of coupling beams with small length to depth ratios and conventional reinforcements is almost brittle. To improve the ductility of the coupling beams, using diagonal reinforcement in the beams has been proposed. However, diagonal reinforcement may increase the construction problems due to the congestion of reinforcement in some parts of the beams. In the recent years, hybrid coupled shear wall system is used for a coupled shear wall with steel coupling beams and reinforced concrete shear walls (Harries, 21). However, the load transfer of steel coupling beam-wall connections with bearing failure has not been thoroughly investigated. It has also shown that the connection details of hybrid coupled shear wall system are exceedingly complex. In addition, recent research (Kurama et al., 24) on steel coupling beams has shown that post-tensioning is an effective method to couple reinforced concrete walls in seismic regions. This paper investigates new type of reinforced concrete coupling beam systems with energy dissipation devices, such as a metallic damper and a friction damper. The principal function of this system is to reduce the inelastic energy dissipation demand on the framing system of a structure and to decrease damage to the framing system. Test programs for the proposed coupled shear wall system are carried out to investigate the hysteresis behavior and to evaluate the energy dissipation capacity. 2. Test Program 2. 1. Test specimens The overall specimens used in this research are summarized in Table 1, which presents beam type, target story drift and shear capacity of damper inserted in beam. The dimensions of specimens and damper details are shown in Figure 1. Specimen is composed of the concrete shear walls and beam with conventional reinforcements, of which dimensions and details are typically used in apartment houses of Korea. Specimen is the reference specimen to compare test result to other specimens. Specimens D1 and D2 are the coupled shear wall specimens with damping systems in beams. These two specimens are same details except for damper types. Specimen D1 has metallic damper as shown in Figure 1. The geometry of damper is an hourglass shape. The geometrical configuration of the plates is such that the bending moments produce a uniform flexural stress distribution over the full length of the plates. The hysteresis behavior of the proposed damper is similar to that of an ADAS damper (Whitaker et al., 1991). As the floor level above deforms laterally with respect to the coupled shear wall, the metallic yielding damper is subjected to a shear force. The shear forces induce bending moment and shear force over the length of the plates, with bending and shear occurring about the weak axis of the plate cross section. Specimen D2 is equipped with a friction damper in beam as shown in Figure 1. Friction dampers dissipate energy via sliding friction across the interface between two solid bodies, which include slotted-holed plates wherein a series of steel plates are bolted together with a specified clamping force. The clamping force is such that slip occurs at a prespecified friction force. Table 7: Test specimen matrix Specimen Beam type Target story drift Damper shear capacity Reinforced concrete beam - - - D1 Steel damper 1.5 % 1 kn Yield strength based on test result of steel material D2 Friction damper 1.5% 1 kn Friction strength 2. 2. Test setup A schematic diagram of test apparatus is shown in Figure 2. As shown in Figure 2, top and bottom of specimen was pinned to the strong beam and floor by hinge devices, respectively. The test specimens are loaded with a 1kN hydraulic actuator to apply load to the strong beam. The displacement of all the specimens is controlled to follow similar displacement histories with progressively increasing amplitude. The loading protocol is shown in Figure 3, which is planned to load 3 cycles at each level. Target story drift of 1.5% was decided that as results of seismic analyses for typical apartment houses, the maximum drift ratios were observed under about.8% ~ 1%. This is because seismic level of Korea is the laterally low and medium. 711

Figure 27: Details of coupled shear wall specimens (unit: mm) 1kN Actuator Strong Beam Strong Frame Hinge Left Wall Coupling Beam Hinge Right Wall H=3455mm Strong Floor Figure 2: Test setup and loading protocol 712

3. Test results 3. 1. Global behavior and failure mode Hysteretic responses and the failure modes are shown in Figure 3. Diagonal cracks occurred in the conventional coupled shear wall specimen. Diagonal cracks of beam and wall opened widely during successive loading. Load-story drift relationship of Specimen illustrated a deterioration effect in their hysteresis loops. The pinching effect is also apparent in its loops. The pinching effect occurred after the concrete cracks, and the stiffness increases when the cracks close due to compression of concrete. Lastly, the beam of Specimen diagonally failed in brittle manner by shear force upon the negative loading of first cycle of fifth step (1.5% drift ratio). These shear failures were examined by shear strain distributions. Figure 4 shows shear strain profiles of beam and wall for all specimens. This strain result exhibited that the shear strain of was significantly larger than those of D1 and D2, resulting in the brittle failure of beam of Specimen. As observed in Figure 3, the Specimen D1 exhibited stable hysteretic behavior until the ultimate state was reached during 1.5% story drift cycles. During loading, although crack was shown at the beam end region connected to shear wall, the crack size was very fine. This result shows that specimen D1 sustained plastic deformation only at the metallic damper without any signs of damage to other parts of the structures. Strength degradation started to appear when cracks slowly formed at the end of steel plates due to stress concentration. The test was stopped after almost all the steel plates in the damper were completely fractured and when the sustained load was significantly reduced. Applied load [kn] 25 2 15 1 5-5 -1-15 -2 Brittle shear failure of lintel beam -25-2 -1 1 2 Story drift [%] Q max = 26.9 kn Applied load [kn] 15 1 5-5 D1 Damper crack propagation -1 Damper crack initiation NQ max = -19.6 kn -15-2 -1 1 2 Stroy drift [%] PQ max = 13.6 kn Damper failure Applied load [kn] 8 4-4 D2 PQ max = 58.87 kn NQ max = -56.8 kn -8-2 -1 1 2 Story drift [%] Load increase due to contact slot end Figure 3: Hysteretic responses and failure modes of specimens Specimen D2 also exhibited stable hysteretic behavior up to 1.5% story drift cycles by sliding mechanism of friction pad. Figure 3 shows that hysteresis loop of Specimen D2 is not rectangular but parallelogram, which means that this hysteresis loop contains the elastic stiffness of RC shear wall and beam. Test result of Specimen D2 reveals that the force output is very stable and has the same value for each direction of sliding, indicating that significant energy was dissipated per cycle of motion during successive loading. Likewise Specimen D1, micro-crack was observed at the beam end region connected to shear wall. The test was stopped at 1.7% story drift since the high strength bolt was in contact with slot end of slotted steel plate, resulting in strength increase directly after contact. 713

4 3 2 SSD D1 GSFD D2 4 3 2 D1 SSD D2 GSFD Shear force[kn] 1-1 Shear wall Beam Shear force [kn] 1-1 -2-2 -3-3 -4-1 -.5.5 1 Wall shear strain [%] -4-1 -.5.5 1 Beam shear strain [%] Figure 4: Shear strains in wall and beam 3. 2. Elastic stiffness and dissipated energy Figure 5 and 6 show response curves and dissipated energy of all specimens, respectively, for comparison of the hysteretic behavior and dissipated energy of each specimen. It was observed that the elastic stiffness of Specimen was almost equal to that of Specimen D1, while the elastic stiffness of Specimen D2 was significantly higher than those of and D1. This result shows that in the case of Specimen D2, the elastic stiffness is governed by the rectangular shape of hysteresis loop of friction pad. The elastic stiffness of metallic damper can be adjusted by altering the method of design. The elastic stiffness of the coupled shear wall system with metallic damper can thus be increased equal to the target stiffness, although elastic stiffness of and D1 are much almost the same in present study. Figure 6 shows the dissipated energy of each specimen in relation to accumulative story drift from test result. The energy obtained from load-displacement hysteresis loop. This plot exhibits that the dissipated energy of specimen with damper is much higher than that of the conventional RC specimen. This result also shows that the energy dissipation of coupled shear wall with damper are concentrated only at the metallic damper or the friction damper, while the inelastic behavior of the shear wall and beam is prevented through appropriate capacity design. Normalized load, Q / Q y 2 1-1 D1 D2-2 -2-1 1 2 Story drift [%] Figure 5: Comparison of response curve Figure 6: Distribution of dissipated energy CONCLUSIONS In this research, a new coupled shear wall system is proposed that features superior energy dissipative capacity. The proposed system is a coupled shear wall system where metallic damper or friction damper is inserted to beam. To verify the performance of the proposed system, quasi-static cyclic tests were conducted on three full-scaled specimens. The conventional RC coupled shear wall specimen showed poor hysteresis loop with pinching effect. However, the proposed coupled shear wall system with dampers exhibited stable hysteretic behavior to target story drift. Damage of these systems are concentrated only at the dampers rather than at the shear 714

wall and beam. ACKNOWLEDGMENTS The author gratefully acknowledges the support of GS Engineering & Construction for financially supporting this research. References Harries, K.A.(21) Ductility and Deformability of Coupling Beams in Reinforced concrete shear walls, Earthquake Spectra, 17(3), pp.457-478. Kurama, Y. and Shen, Q(24). Post-Tensioned Hybrid Coupled Walls under Lateral Loads, Journal of Structural Engineering, ASCE, 13(2), pp.297-39. Paulay, T.(1971) Coupling Beams of Reinforced Concrete shear wall, Journal of Structural Division, ASCE, 97(ST3), pp.843-862. Whittaker, A.S., Bertero, V.V., Thomson, C.L., and Alonso, L.J.(1991) Seismic Testing of Steel-Plate Energy Dissipating Devices. Earthquake Spectra, 7(4), pp.563-64. 715