SSS003: Substrate Specification Sheet 3 - Brick, Block and Concrete

Similar documents
SSS001: Substrate Specification Sheet 1 - Plasterboard Drylining Installation and Finishing

SWI001: Squash Plaster Working Instructions 1 - New Build

SSS009: Substrate Specification Sheet 9 - Render Board

Document: Collection: Technical Data sheets Modified: 24/06/2016 Created: 24/06/2016

Building Construction 14. Dr Nabil El-Sawalhi Associate professor Engineering Projects Management

Plaster systems. Plaster systems.

Polymer bonding aid and mortar additive bonding agent for old and new concrete. Test method Typical result Control. Compressive strength (BS6319,Pt2)

Plaster systems. High quality lining solutions providing the perfect finish for your walls

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

Caparol System PRO Data sheet

PART A: JOB PROCDRE FOR PLASTERING

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

Plasters and plaster accessories - Products

TILING SPECIFICATIONS

PDS22. Product Data Sheet 22. Armourcoat SCULPTURAL Wall System. 1 Product Description. 5 Suitable Substrates. 2 Materials and Composition

TECHNICAL INFORMATION SCREED

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

CDK Neolith Reduced Thickness Porcelain Panel Installation Specification.

RESIN FLOORING. To be read with Preliminaries/ General Conditions TYPE(S) OF FLOORING

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

Plastering. Holiday Inn - Sultanate of Oman

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) MASONRY [BLOCKS] [BRICKS] [STONE]

Good Construction Practices Part II

SUPER multi purpose structural adhesive. Polymer admixture for cement systems

TECHNICAL INFORMATION CEMSCREED 5

Construction. Sikadur 31, Hi-Mod Gel. Application Instructions. Sika Corporation

All work in this section shall be the responsibility of the Main Contractor.

Method Statement. For RSA Cement Renders Over Masonry Substrates

SURFACE PREPARATION INSTRUCTIONS: CONCRETE

BACKSTOP NT - Texture A high performance, non-cementitious water-resistive membrane and air barrier. Backstop NT - Texture Application Instructions

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE

ARTEX AND PLASTER. 2 - Choosing the right product

Waterproofing Systems. Cementitious.

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

Application Guidelines for PPC Coatings Flooring

Construction. Sikadur 35, Hi-Mod LV. Application Instructions. Sika Corporation

Product: Ready mix brick slip adhesive

TECHNICAL DATA SHEET AUS-CRETE PREMIUM INDUSTRIAL

Satori Japanese Wall Finishes

Product Data Sheet PDS022: Sculptural Wall System

Ezarri JointPoint Glass Mosaic Tile Installation in Immersed Installations. 10 Year System Warranty.

Module 11: Plastered walls

SECTION UNIT MASONRY

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

External solid plastering: overview

SECTION RESILIENT SHEET FLOORING

STONE PRODUCT SPECIFICATION SANDSTONE. Some typical installation methods are: Pedestrian traffic only: reinforced concrete* 75mm thick

2. Subfloor Preparation - Removal of Existing Floor Coverings

Union County Vocational - Technical Schools Scotch Plains, New Jersey

NBS M50 ALTRO WHITEROCK DIGICLAD WALL CLADDING

TECHNICAL INFORMATION LIME SAND MORTARS

Ezarri JointPoint Glass Mosaic Tile Installation in Immersed Installations. 10 Year System Warranty.

FireCase. Frameless structural steel encasement system. FireCase.

System Recommendation SR0618

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

BRICKWORK 3.5 BRICKWORK 1 GENERAL

Kolorines Glass Mosaic Tiles Project Specification

TECHNICAL DATA SHEET AUS-BOND INDUSTRIAL LATEX ADMIX

RhinoPlast. RhinoWall. RhinoCeil. GypWall. DonnCeil. Saint-Gobain Construction Product Service Centres. Saint-Gobain Gyproc (Pty) Ltd

TECHNICAL DATA SHEET AUS-CRETE MPA

repairing the surface of concrete casting defects and minor damage

Desco Granite Flooring Specifications

INSTALLATION METHOD STATEMENT

LIQUID APPLIED WATERPROOF ROOF COATINGS

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

Concrete Wall & Floor Finishes

Limitations and Conditions

TECHNICAL INFORMATION

General Glass Mosaic Tile Fixing Specification for Immersed Installations.

GENERAL SPECIFICATION FOR SCREEDING / LEVELLING AN INTERIOR FLOOR USING TAL SCREEDMASTER SELF LEVELLING SCREEDING COMPOUND

Westbuild PRO. Rapid Drying Wet Area Waterproofing. Polyurethane (PU) modified, permanently flexible, rapid drying, class III waterproof membrane.

MANUFACTURER S SPECIFICATIONS Section LIMESTONE PLASTER

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

Mapetherm AR1 Light. Lightweight one-component cementitious mortar FOR THERMAL INSULATION WITH SUPERIOR LIGHTNESS AND ASTONISHING PERFORMANCE

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

INSULCLAD EXTERIOR CLADDING SYSTEMS

A100 SHOWERPROOF NON-SLIP CERAMIC TILE ADHESIVE

SECTION MORTAR

Method Statement. For RSA Coating Systems Over AAC Lightweight Blocks N.B. Please refer to separate Application Guidelines for AAC Lightweight Panels

Method Statement. For RSA Coating Systems Over AAC Lightweight Blocks N.B. Please refer to separate Application Guidelines for AAC Lightweight Panels

Method Statement. For RSA Coating Systems Over M Grade Expanded Polystyrene (EPS)

SECTION PORTLAND CEMENT TERRAZZO FLOORING

Intercrete 4802 Application Guidelines

Finishes. The visual quality of your finished wall or ceiling is dependent on the quality of workmanship and quality of the materials used.

WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

TECHNICAL DATA SHEET AUS-FLEX MULTI-LIGHT 9.5

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

850 SOLID LIGHTWEIGHT READYBLOCK

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

TECHNICAL DATA SHEET AUS-FLEX MULTI

TECHNICAL BULLETIN TB249 PATCHING AND RENDERING OF CONCRETE, CONCRETE BLOCKWORK & BRICKS, BEFORE TILING OR FAÇADE FINISH WATERPROOFING

EN R4 High Strength High Build Concrete Repair Mortar

ECO OUTDOOR INSTALLATION TIPS WALLING TRADITIONAL FORMAT MELBOURNE SYDNEY BRISBANE ADELAIDE PERTH T ECOOUTDOOR.COM.

SS202 Sto Concrete Block Plaster System 1

Lastogum X. Waterproof, flexible protective coating. Under ceramic coverings in showers and bathrooms

CONCRETE BLOCK MASONRY

Method Statement for Application Of Sikafloor Terrazzo EG SIKA EGYPT. Decorative Terrazzo System

Transcription:

SSS003: Substrate Specification Sheet 3 - Brick, Block and Concrete Page 1 of 6 Document: 70.5 Collection: 116: Substrate Specification Sheets (SSS) Modified: 3/01/017 14:56 Created: 7/05/016 17:0 Armourcoat Ltd Morewood Close Sevenoaks Kent TN13 HU T: +44(0)173 460 668 F: +44(0)173 450 30 UK Company 17888. VAT Reg: 445788013 www.armourcoat.com SSS003: Substrate Specification Sheet 3 - Brick, Block and Concrete Armourcoat (ASF) QA Working Specification For Plaster On Brick, Block Or Concrete Substrates 1 Introduction This specification, which particularly emphasises the considerations required on build quality and surface flatness, has not been written for Armourcoat's benefit but seeks to provide a quality of finish which will receive the long term approval of the client and meet or exceed the expectations of the Architect and Project Managers. The specification is for guidance only. It describes good working practice. It does not claim to be the right or only way of creating a satisfactory substrate and is made without responsibility for the execution of the work. Build quality is the responsibility of the builder. Polished Plaster does not shrink or crack when drying. It is a hard product and any cracks forming in the substrate will penetrate through the finish. Take particular care with lightweight blocks which will shrink and crack if blocks are wet when laid. Gypsum Plasters For Masonry and Concrete Substrates Plastered brick, blockwork or concrete substrates provide a good structural background for Venetian Polished Plaster. The following Gypsum plasters provide suitable undercoats. Plaster Grade For Ultimate Substrate Hardness: Armourcoat Squash Court Basecoat Armourcoat Squash Court Finish Thistle Hardwall Thistle Multi-Finish Thistle Browning Thistle Multi-Finish Thistle Bonding (Concrete) Thistle Multi-Finish Recommended Thickness (mm) All plasters shall be used in accordance with the recommendations of BS54 Code of Practice for Internal Plastering. 3 Movement Joints Movement beads as appropriate shall be installed flush with the line of the undercoat plaster, to coincide with the position of movement joints in the substrate. 4 Undercoat Plasters on Reinforced Concrete (RC) Substrates and Smooth Faced Concrete Blocks, Engineering Bricks and Lightweight Thermal Blocks Impurities in construction materials and on substrate surfaces cause problems. Substrates must be free of curing compounds, dust, laitance, and other impurities such as oil, grease, salts, and PVA (Polyvinyl Acetate) film resulting from priming agents used overstrength on dense non-porous brick, block or concrete. Ballast concrete backgrounds shall be given sufficient time to mature before dubbing out and plastering. Mature concrete shall be wetted approximately 10 minutes before plastering commences. Smooth Faced Concrete Blocks, Smooth Faced Engineering Bricks and Concrete Blocks made from limestone, granite and certain lightweight thermal blocks will require pre-treatment with a bonding agent. The following procedure should be adopted to prevent future delamination and to create a wall within tolerances.

5 Recommended Plastering Procedures Wet wall with clean water. Brush and stipple damp wall with a bonding coat comprising: 1. One part OP cement. Two parts washed medium (Zone ) sand, gauged with Armourcoat R13 Resin 1:1 with clean water Leave a coarse surface texture, and allow to cure for 4 hours. Set wall plane by plumb and dot procedures or guarantee flatness to specified tolerances. SSS003: Substrate Specification Sheet 3 - Brick, Block and Concrete Page of 6 To minimise the risk of delamination, when bonding coat is thoroughly dry, and before applying the undercoat plaster, brush bonded surface with a slurry of Armourcoat Squash Court plaster gauged with Armourcoat R13 Resin 1: with clean water This procedure starts the wet on wet application procedure. While slurry is still wet, working wet on wet, build to specified thickness over high spots. If the slurry coat dries out, re-coat before continuing Armourcoat Squash Court application. 6 Undercoat Plasters on Blockwork & Clay Bricks Aggregate concrete blocks and "common" clay brick substrates need no special bonding and the following procedure is recommended: Set wall plane by plumb and dot procedures or guarantee flatness to specified tolerances. Wet wall to reduce background suction. Apply plaster as a continuous operation, starting with a tight coat, well pressed into pores and fissures, leaving no voids. Working wet on wet, build to specified thickness (see table Ref ) over high spots. With a Feather Edge or Darby, straighten vertically and horizontally between levelling screeds to achieve a flat, true surface. Fill in slacks and hollows while the plaster is still tacky. 7 Finishing Plaster The appropriate Finishing Plaster shall be applied as a two-coat system, wet on wet, by firm trowelling. Ideally, the Finishing Plaster shall be applied on the same day as the Basecoat and as soon as the Basecoat has set hard. If this is not possible, the Basecoat must be re-wetted to control "suction" before the Finishing Plaster is applied. 8 Mixed Substrates Polished Plaster applications on walls built in mixed materials shall be avoided. Varying expansion and flexion characteristics between different substrate types will cause cracking, particularly in walls with brick or block infill, between RC beams and/or columns. Armourcoat Limited recommends that walls built in mixed materials are dry lined. Internal Angles All internal angles shall be jointed with jute scrim in an approved manner. 10 External Angles External angles shall be strengthened with stainless or galvanized steel angle beads set flush with the line of the undercoat plaster. In locations where corner damage may occur, pencil rounding the corners without angle beads or inserting wood or metal end posts or cappings shall be specified. Plastering beads are available from British Gypsum Ltd (Tel: 0800 55), Expamet (Tel: 014 866 688) or Cornercare (Tel: 0156 515 00). For detailing drawings please refer to the end of this document. 11 Priming Priming is only required when different materials other than the original has been used to repair the wall. Using different materials will result in different suctions therefore a primer should be used to equalise the different suctions. However Armourcoat recommend that a primer should be applied to high suction backgrounds ie Multi-Finish. 1 Drying Substrate must be allowed to fully dry (not just on the surface) If a substrate has been primed prior to the substrate being fully dry, water will be trapped in the substrate. Trapped moisture can cause discolouration in the Armourcoat finish.

SSS003: Substrate Specification Sheet 3 - Brick, Block and Concrete Page 3 of 6 0 degree corner detail for Armourcoat finishes on brick / block / concrete substrates

SSS003: Substrate Specification Sheet 3 - Brick, Block and Concrete Page 4 of 6 Shadow gap door junction detail for Armourcoat finishes on brick / block / concrete substrates

SSS003: Substrate Specification Sheet 3 - Brick, Block and Concrete Page 5 of 6 Stop bead detail for Armourcoat finishes on brick / block / concrete substrates

SSS003: Substrate Specification Sheet 3 - Brick, Block and Concrete Page 6 of 6 Stop bead door junction detail for Armourcoat finishes on brick / block / concrete substrates Whilst every attempt has been made to ensure the accuracy and reliability of the information contained in this document, the information should not be relied upon as a substitute for formal advice. Armourcoat Ltd, its employees and agents will not be liable for any loss or damage, of any kind, arising out of or in connection with the use of this document. Please refer to the company disclaimer for further details.