Application Note. Raman Spectroscopy Analysis of Crystalline Polymorphs for Pharmaceutical Development

Similar documents
Application Note. Introduction. Analysis of crystal polymorphism by Raman Spectroscopy for Medicine Development

Laser Raman Spectrometer

The Raman effect, discovered in 1928 by C.V. Raman in his

TIME-RESOLVED PHOTOLUMINESCENCE SUPPRESSED RAMAN SPECTROSCOPY OF DRUGS

Zetasizer ZS Helix (DLS/Raman) For Characterization of Pharmaceuticals and Biopharmaceuticals

Insight into solid state properties during processing

CHAPTER 7 MICRO STRUCTURAL PROPERTIES OF CONCRETE WITH MANUFACTURED SAND

AFM-Raman Characterization of Pharmaceutical Tablets

An Investigation of Non-Crystalline Materials Using X-ray Powder Diffraction. PPXRD 12 Beijing May 2013 Simon Bates: Triclinic Labs

Quantifying the amorphous phase with nearinfrared and Raman spectroscopic techniques

Carbon Black At-line Characterization. Using a Portable Raman Spectrometer

Thermal Analysis. Dr. Lidia Tajber School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin

Preparation and properties of PTFE anti-friction coating

Thermo Scientific ARL EQUINOX 100. X-ray Diffractometers

Characterization of Li 3+ /Mg SO 4.7H 2 O Crystal

ELECTROLYTIC PHASE EXTRACTION: AN OLD TECHNIQUE TO EVALUATE PRECIPITATES IN NITINOL

Overall Conclusions and Future Projections OVERALL CONCLUSIONS

In situ semi-quantitative assessment of single cell viability by resonance

Material Identification Through Packages using 1064nm Excitation Raman Spectroscopy

Preface... iii Contents...vii Contributors...xv. 1 Introduction to Hot-Melt Extrusion, Continuous Manufacturing: Scale-up via Hot-Melt Extrusion...

It is instructive however for you to do a simple structure by hand. Rocksalt Structure. Quite common in nature. KCl, NaCl, MgO

Practical Guide to Hot-Melt Extrusion: Continuous Manufacturing and Scale-up

Spatially resolved crystal domain identification: Implementing Laue-mapping technique on the M4 TORNADO spectrometer

Study the Structure, Morphology and Vibration Modes for K 2 CrO 4 and K 2 Cr 2 O 7

Preparation and Characterization of Copper Oxide -Water Based Nanofluids by One Step Method for Heat Transfer Applications

New Methods for Preparing Cyclodextrin Inclusion Compounds. I. Heating in a Sealed Container

Structure Identification of Ni- Fe Oxide Mixture using Raman Spectroscopy, and X-ray Absorption Near-Edge Spectroscopy

PARTICULATE ANALYSES

Supporting Information. Selective Metallization Induced by Laser Activation: Fabricating

Characterization of amorphous pharmaceuticals what can you do in the home lab? Michael Evans, Christina Drathen Bruker AXS GmbH, Karlsruhe, Germany

Studying Amorphous Pharmaceutical Materials by Powder X-Ray Diffraction and other Solid-State Techniques

Supplementary Information

Particle size analysis of gadolinium doped sodium bismuth titanate ceramics

Raman Spectroscopy for Pharmaceutical Applications

Electron Probe Micro-Analysis (EPMA)

Synthesis calcium-titanate (CaTiO 3 )

CHAPTER 4 GROWTH AND CHARACTERIZATION OF 4-NITROPHENOL UREA SINGLE CRYSTALS

Europe. Benchtop X-Ray Diffractometer.

CHAPTER 5 GROWTH OF POTASSIUM TETRA BORATE (K 2 B 4 O 11 H 8 ) SINGLE CRYSTALS BY LOW TEMPERATURE SOLUTION GROWTH METHOD AND ITS CHARACTERISATION

Smithsonian Museum Conservation Institute

International Journal of

Quantitation of amorphous content

August 9, Jim Atkinson Sort Pro Services, LLC 901 Armstrong St. Algonquin, IL Report:

Supplementary Electronic Information for:

PROCESS OF DESTRUCTION OF TEREPHTHALIC ACID IN SUPERCRITICAL WATER

Dr Claire MacDonald Business Development Manager CMAC National Facility

CHAPTER 5. HIGH PRESSURE MICRO RAMAN STUDIES ON SINGLE CRYSTAL Yb 2 O 3

Introduction. History. Very brief history of technique Discovery; when it came into use Use today

APPLICATIONS OF XRD,DSC,DTA. Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy

OPTIMIZING XRD DATA. By: Matthew Rayner

In IR it is usual to express the wavelength in micrometers (microns), 1 micro = 10-6 m, or in wavenumbers, cm -1.

Growth Of TiO 2 Films By RF Magnetron Sputtering Studies On The Structural And Optical Properties

Guidelines for Pharmaceutical Equivalence Requirements

Nanoconfinement Crystallization of Frustrated Alkyl Groups: Crossover of Mesophase to Crystalline Structure

Supplement of The effects of nitrate on the heterogeneous uptake of sulfur dioxide on hematite

Seminar: Structural characterization of photonic crystals based on synthetic and natural opals. Olga Kavtreva. July 19, 2005

Soil Sampling, Preparation and Analysis

Lesson 1 Good Diffraction Data

CEMS study on diluted magneto titanium oxide films prepared by pulsed laser deposition

CHAPTER 4. SYNTHESIS OF ALUMINIUM SELENIDE (Al 2 Se 3 ) NANO PARTICLES, DEPOSITION AND CHARACTERIZATION

X-Ray Diffraction by Macromolecules

Thermo Scientific ARL EQUINOX X-ray Diffractometers

BLOCK COPOLYMERS ORGANIZATION AT INTERFACE

Supporting Online Material for

Introduction to Polymer-Dispersed Liquid Crystals

Earth & Planetary Science Applications of X-Ray Diffraction: Advances Available for Research with our New Systems

Physical pharmacy. dr basam al zayady

Preformulation. By: Ass. Prof. Gamal Shazly

Injection Moulding as a One-Stop-Production to Produce Pharmaceutical Dosage Forms

VOLUME FRACTION ANALYSIS

CHAPTER-2 HEAVY METAL OXIDE GLASSES CONTAINING BISMUTH AND LEAD

X-ray Diffraction and Vibrational Spectroscopy of Catalysts for Exhaust Aftertreatment

Supplementary Figures

X-Ray Analytical Methods

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT:

Microstructural Characterization of Materials

Preparation and characterization of Co BaTiO 3 nano-composite films by the pulsed laser deposition

Travaux Pratiques de Matériaux de Construction

PRECIS AND CONCLUSIONS

Supporting Information

Non-agglomerated iron oxyhydroxide akaganeite nanocrystals incorporating extraordinary high amounts of different dopants

Gemmology. -lutterworth E I N E M A N N. Second edition. P.G. Read OXFORD AUCKLAND BOSTON JOHANNESBURG MELBOURNE NEW DELHI

Introduction to Powder Diffraction/Practical Data Collection

New amorphous materials with applications in optics, optoelectronics, chemistry, medicine and biology prepared by pulsed laser deposition

Introduction. History. Single-Crystal vs. Powder

ATTACHMENTES FOR APD 2000 PRO POWDER X-RAY DIFFRACTOMETER. Monochromators

Rapid Imaging of Microstructure using Spatially Resolved Acoustic Spectroscopy

CHAPTER 3 PHYSIO-CHEMICAL CHARACTERISATION

PARACETAMOL MICRONIZATION BY PRECIPITATION WITH THE SAS / SEDS PROCESS: INFLUENCE OF PROCESS PARAMETERS

White Paper. Crystallization in Process Chemistry Applying Simple PAT Tools. Author: Des O'Grady PhD, METTLER TOLEDO

Crystal Growth, Optical and Thermal Studies of 4-Nitroaniline 4- Aminobenzoic Acid: A Fluorescent Material

VIBRATIONAL STUDIES OF Na 2 SO 4, K 2 SO 4, NaHSO 4 AND KHSO 4 CRYSTALS

SYNTHESIS, CHARACTERIZATION AND PHOTOCATALYTIC ACTIVITY OF MgO NANOPARTICLES

A SOLVENT-FREE COMPOSITE SOLID ELECTROLYTES OF Li 2 CO 3 Al 2 O 3 SYSTEM PREPARED VIA WATER BASED SOL GEL METHOD

X-Ray Diffraction Analysis

Solids SECTION Critical Thinking

One-step Solvothermal Synthesis of Highly Water-soluble, Negatively Charged Superparamagnetic Fe 3 O 4 Colloidal Nanocrystal Clusters

Amorphous Quantitation Strategy for Crystalline Drug Substance a GSK Perspective. Peter Varlashkin GSK, Durham, NC, USA PPXRD 11

Standard Practice for Identification of Polymer Layers or Inclusions by Fourier Transform Infrared Microspectroscopy (FT-IR) 1

Fe doped Magnetic Nanodiamonds made by Ion

Transcription:

Raman Applications in the Pharmaceutical Industry Impurity Analysis (Identification of micro impurities - sizes less than 1 µm) Evaluation of Synthetized Compounds (Structural analysis in combination with IR) Mapping (Evaluation of tablets for DDS research) Jasco NRS Series Raman Micro-spectrometers PAT (Real-time control in pharma production process) Evaluation of Crystal Polymorphs (Evaluation method instead of XRD and DSC) Keywords: NRS-5000, NRS-7000, dispersive Raman, Raman spectroscopy, Raman imaging, thermal melting, DSC, XRD, pharmaceutical analysis, Acetylsalicylic acid, aspirin, crystal polymorphism, crystal structure, trehalose, ampicilin, beta lactam, TiO2, Titanium dioxide, Indomethacin 28600 Mary s Court, Easton, MD 21601 USA Application Library: http://ww w.jascoinc.com/applications

2 / 12 What is a Crystal Polymorph.? Crystal polymorphism is a phenomenon where compounds with the same chemical formula can be crystallized into different crystalline structures. The crystal structure depends on the conditions (such as temperature and pressure) used in the crystal formation process. The resulting crystal structures are conveniently classified as Form I, II, III or T a and T b. In medicine, the solubility, stability and bio-availability will depend on the crystal polymorphism; compounds with different crystal structures may even be recognized as different compounds. Therefore, research into crystal polymorphism is widely used in areas such as basic studies, structure/function correlation of compounds and industrial applications such as patent applications. In the pharmaceutical industry, the study of crystal formation techniques is very important for the control of crystal structure and the manufacture of high quality medicines. Methods for Evaluation of Crystal Polymorphism Three analytical techniques are used in the evaluation of crystal polymorphism Instrument Principle Advantage Disadvantage XRD Evaluation of crystal structure by X-ray diffraction. Accurate distance between atoms in crystals. XRD is widely used for crystal structure analysis. Amorphous structure cannot be evaluated by XRD. DSC Stability and melting point of crystals are evaluated by endothermic/exothermic reaction of the crystal when heating/cooling the sample Properties of the crystal can be observed. Crystal structure cannot be determined by DSC. Raman Chemical structure is evaluated by detecting scattering light at low wavenumbers derived from lattice vibration, by laser irradiation of the sample. Both crystal and amorphous structures can be evaluated. Vibrational information of molecules can also be obtained from high wavenumber spectra. High spatial resolution and micro measurement can be done. Sample preparation is not required. It is difficult for Raman to evaluate the absolute configuration of a crystal. Raman Spectroscopy is one of the hot analytical techniques for the study of crystal polymorphism!

3 / 12 Features of Raman Spectroscopy for Evaluating Crystal Polymorphism (vs. XRD) The above spectra show results for both crystalline and amorphous structures of Indometacin using XRD and Raman spectroscopy. Generally it is difficult to measure samples with less reflection (less diffraction spot) such as amorphous and/or minute crystals using X-ray crystal analysis. Since the actual medicine formlations include amorphous and minute crystals in a mixture, Raman spectroscopy is more effective as shown in the right figure. Presently X-Ray crystal analysis is used for the basic study of crystal structure for patent registration, however due to the above reasons, Raman is expected to become a more widely used technique in the pharmaceutical industries for patent registration. Features of Raman Spectroscopy in Crystal Polymorph Evaluation (vs. DSC) It is known that Acetylsalicylic acid can exists in crystalline Forms I and II. XRD can be used for crystal structure analysis, but thermal stability cannot be evaluated and useful spectra cannot be obtained for amorphous structures at temperatures higher than the melting point. Conversely, DSC can be used to evaluate the thermal stability of a crystal, but structural information cannot be obtained.

4 / 12 Raman spectra of Acetylsalicylic acid of different particle size Commercial Acetylsalicylic acid with several different particle sizes were selected and measured using Raman. The results show a change in peak ratio observed in the higher wavenumber region, this is due to the differences in the crystal axis. In addition, differences in the Raman spectra were observed in the region below 200 cm-1 due to differences in particle size and measured position. These results indicates that the commercial medicine is in a mixed crystal state and it is therefore difficult to analyze using DSC due to the different melting points of the crystal forms. NRS-5000 system with heating stage By mounting temperature control system on NRS-5000 series, it is possible to monitor in-situ the structural changes in samples.

5 / 12 Raman spectra of Acetylsalicylic acid of different particle size Commercial Acetylsalicylic acid with several different particle sizes were selected and measured using Raman. The results show a change in peak ratio observed in the higher wavenumber region, this is due to the differences in the crystal axis. In addition, differences in the Raman spectra were observed in the region below 200 cm-1 due to differences in particle size and measured position. These results indicates that the commercial medicine is in a mixed crystal state and it is therefore difficult to analyze using DSC due to the different melting points of the crystal forms. NRS-5000 system with heating stage By mounting temperature control system on NRS-5000 series, it is possible to monitor in-situ the structural changes in samples.

6 / 12 Real-time Monitoring of Trehalose using a Heating Stage (1) In-situ monitoring of Trehalose 2H2O (which has high water retention and is used for foods and medicines) at 80 deg. C - spectra measured at one minute intervals. The results shows time-dependent changes in the spectra. Real-time Monitoring of Trehalose using a Heating Stage (2) The half bandwidth and the peak shift of two peaks which demonstrate the hydration feature in the previous page were analyzed. The results indicate that the changing process of the peak shift and half bandwidth was observed in three steps and by analyzing peaks in the region 1000-700 cm-1. It was confirmed that the crystal structure of Trehalose changes from a pre-stable structure (crystal or Amorphous) to a stable structure. The combination of Raman fitted with a temperature control system enables the analysis of kinetic structural changes with sample melting.

7 / 12 Features of the NRS-5200 in the evaluation of crystal polymorphism The above figure shows IR and Raman spectra of L-cystine. Raman spectroscopy enables measurement in the low wavenumber region below 400 cm -1 ; in addition, the NRS-5200 can provide information for the crystal lattice vibrations in the very low wavenumber region down to 10 cm -1. Since Raman scattering from aqueous solutions or glass is weak, sample pretreatment is not necessary and samples in glass or aqueous samples can be measured easily and non-destructively. One of the features of the NRS-5000 is that crystal polymorphism can be evaluated quantitatively and qualitatively at a high spatial resolution down to ~1 µm. Low Wavenumber Measurements using a Notch Filter NRS-5000 series allows not only measurement of the usual inorganic and organic samples, but also measurement in the low wavenumber range using the most suitable optical arrangement. It is possible for the user to easily adjust the optimal angle of the notch filter for low wavenumber measurement as required for each sample. In addition the NRS-7200 allows very low wavenumber measurement down to 5 cm -1 using the low wavenumber measurement unit. NRS-5100/7100 : down to 50 cm-1 NRS-5200 with low wavenumber measurement unit : down to 10 cm-1 NRS-7200 with low wavenumber measurement unit : down to 5 cm-1

8 / 12 Low Wavenumber Measurement of Bismuth Oxide by Adjusting the Notch Filter Angle Since peaks of minerals or lattice vibration derived from crystals are detected in the low wavenumber region, Raman measurement in the low wavenumber region is very important. Rejection of Rayleigh scattering is the key point to detect peaks in the low wavenumber region, so careful optimization is necessary to adjust the angle of the notch filter depending on the sample requirements. Low Wavenumber Measurement using a Notch Filter: Titanium Oxide with Crystal Polymorphs NRS-5000 series allows not only measurement of the usual inorganic and organic samples, but also measurement in the low wavenumber range using the most suitable optical arrangement. It is possible for the user to easily adjust the optimal angle of the notch filter for low wavenumber measurement as required for each sample. In addition the NRS-7200 allows very low wavenumber measurement down to 5 cm -1 using the low wavenumber measurement unit.

9 / 12 Measurement of Trehalose using the Low Wavenumber Measurement option on the NRS-7200 Sometimes important peaks are obscured by the notch filter when used with a single monochromator, however, the low wavenumber measurement unit fitted to the NRS-7200 enables clear measurements in the low wavenumber region. NRS-7200 with low wavenumber measurement unit Measurement of Acetylsalicylic acid using the NRS-7200 Low Wavenumber Measurement Unit Acetylsalicylic acid was measured with the NRS-7200. The upper spectrum was obtained using the NRS-7200 fitted with a low wavenumber measurement unit, the lower spectrum, without using the option. Using the low wavenumber measurement unit, peaks for the lattice vibrations in the analgesic compound can be clearly observed and important information for crystal polymorph identification can be obtained.

10 / 12 Measurement of Carbamazepine Polymorphs using the NRS-7200 Low Wavenumber Measurement Unit Since Raman spectroscopy can easily detect peaks in the wavenumber region below 100 cm -1, it is possible to identify the differences between Forms I and II of carbamazepine whose crystal structures are quite similar. However, the low wavenumber measurement unit is required to characterize the Form III polymorph. Measurement of Acetaminophen (Paracetamol) using the NRS-7200 Low Wavenumber Measurement Unit Commercially available Acetaminophen was measured using the NRS-7200. It is known that there are three crystal polymorphs of Paracetamol - Form I, II and III. The above spectra shows the Form I polymorph.

11 / 12 Measurement Indomethacin Polymorphs using the NRS-7200 Low Wavenumber Measurement Unit: Patent of Crystal Polymorphs The above spectra were obtained by measuring commercially available Indomethacin using the NRS-7200 with and without the low wavenumber measurement unit. It is known that Indomethacin exists as three different crystal polymorphs: alpha (acicular crystal), beta and gamma (plate crystal). Gamma is the most stable structure followed by the alpha structure. Recently, alpha has been selectively manufactured (and patented) to be used for external medicine for enhanced skin absorption and stability. The method for effective manufacturing of a specified crystal polymorph is extremely important. Research papers including low wavenumber measurement- Ampicillin which has several polymorphs-

12 / 12 Measurement Indomethacin Polymorphs using the NRS-7200 Low Wavenumber Measurement Unit: Patent of Crystal Polymorphs