EuroFID Total Hydrocarbon Analyzer

Similar documents
Heated FID OVF Portable THC/TVOC Analyzer

S700 Modular Gas Analyzer. Measures more than 60 different gases

Volume Flow and Gas Flow Measuring Devices

Online data sheet MCS100E HW-C CEMS SOLUTIONS

GMS800 FIDOR Total hydrocarbon analyzer. Gas Analyzers

TVOC Heated FID VE 7

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

Online data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS

Online data sheet SMC209 C CEMS SOLUTIONS

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Online data sheet MCS300P HW PROCESS SOLUTIONS

8 stream capability with dual mode (H 2 S & total Sulphur)

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

OXITEC Oxygen Analyser Systems. Maximum Efficiency and Supreme Quality for the World Market ENOTEC

Data sheet HYGROPHIL H 4230 process hygrometer

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

MLT 2 Multi-Component Gas Analyzer

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

ACX Analyzer systems for emission monitoring, cement applications and process measurement

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

GAA330-M Emission monitoring system for marine applications

Online Infrared Flue Gas Analyzer Gasboard 3000

Robust flue gas probes for industrial emissions measurements.

Flameproof Zirconia Oxygen Analyzer ZS8C, ZS8D. Flameproof Zirconia Oxygen Analyzer ZS8C, ZS8D. Bulletin 11M07A03-02E.

System overview. Lambda Transmitter LT2 Lambda Probe LS2 (K) for measurement of oxygen (O 2 ) Sensors and Systems for Combustion Engineering

COMBIMASS Thermal Gas Flow

Process Analytics. Reliability and efficiency in continuous gas analysis. A strong family for your success. usa.siemens.com/cga

Professional flue gas analyzer Testo AG LPG

Online Gas Analyzer / Monitor

Analyzer Module Wet Chemiluminescence Detection (WCLD)

PRODUCT CONFORMITY CERTIFICATE

Measurement Systems for Oxygen and Combustibles

For Safe and Delicious Water

ABSORPTION MEASURING INSTRUMENT

Reference flue gas analyzer

OXITEC O 2. InSitu analyser systems DEVELOPED AND MANUFACTURED IN GERMANY

CEMTEC Patented self cleaning gas sampling probe for continuous measurement in any high dust and high temperature process

SERVOMEX PRODUCT OVERVIEW

Fpollutant-free zero air for analytical

Professional flue gas analyzer

RC400G FC400G RESIDUAL CHLORINE ANALYZER RC400G NON-REAGENT FREE CHLORINE ANALYZER FC400G RESIDUAL CHLORINE ANALYZER

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Professional flue gas analyzer

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

REFERENCE MEASURING INSTRUMENT

Model Product Description and Specifications

PRODUCT CONFORMITY CERTIFICATE

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

GAS 3050P NDIR FLUE GAS

Fine particle measuring system

New Measurement Engineering for Heating Technicians and Inspectors

ON-LINE OIL TRACE MONITOR

Model Product Description and Specifications

GAS ANALYZERS. Digital Manometer

HILASE - QUALITY CONTROL INSTRUMENT

Flue Gas Analysing System

Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC

( ppm ) ( ppm ) ( ppm ) History :46:43

Compact flue gas analyser: testo 300 M-I

Total Solution for Syngas Analysis

Raw gas sampling and conditioning for particle characterization.

PRODUCT CONFORMITY CERTIFICATE

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

New Measurement Engineering for Heating Fitters and Technicians

Using the PPM2 Portable Trace Moisture Transmitter

Fine particle measuring system

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

Raw gas sampling and conditioning for particle characterization.

MAX300-AIR PRODUCT NOTE. Ambient Air Monitoring Flare Gas Analysis Industrial Health and Safety. Environmental Mass Spectrometer

Continuous Emissions Monitoring in Support of the Cement MACT

testo 340 Speed, power & precision in industrial combustion analysis.

Just a few clicks away from a heating system diagnosis.

Just a few clicks away from a heating system

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001

Just a few clicks away from a heating system diagnosis.

Type Type 2000 Transducers. I/P & E/P Transducers

COMTEC O 2. InSitu analyzer systems. / CO e DEVELOPED AND MANUFACTURED IN GERMANY

Just a few clicks away from a heating system

OXITEC O 2. InSitu analyzer systems DEVELOPED AND MANUFACTURED IN GERMANY

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

UniGas Hand-held combustion gas analyzer with 4 sensors

Measuring moisture in ultra-high-purity gases

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

AS950 REFRIGERATED SAMPLER

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

FTIR Analyser BROCHURE

AS950 ALL-WEATHER REFRIGERATED SAMPLER

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Thermogravimetric Analyzer

PROCEAS H2 IN NEARLY PURE CL2

Oxygen & Other Gases Measurement and Analysis

New Measurement Engineering for the Domestic Installer and Heating Contractor

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity

testo 340 Speed, power & precision in industrial combustion analysis.

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

TRACE ANALYTICAL. ta7000 Series UHP Gas Purity Monitors At the critical link in your manufacturing process. Features /Benefits

Transcription:

Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Analyzers and Process Instrumentation

Proven Analyzer Technology Measuring total hydrocarbons The EuroFID measures total hydrocarbons in air, in corrosive as well as in condensing gases at process temperatures up to 600 C 1). In trace concentrations up to 100 vol%. EuroFID is modular and can be put together in a system using the best components (analyzer, terminal box, control unit) for the particular installation. 1) The temperature on entering the probe pipe of the in-line unit must not exceed 400 C and the dew point temperature must not exceed 220 C. Typical applications Exhaust gas measurement of hydrocarbon emissions in raw and clean gas Emission measurement in power stations and waste incineration plants Emission measurement after thermal, catalytic and biological oxidation units and after activated charcoal exhaust air cleaning systems Monitoring raw gas concentrations prior to exhaust gas cleaning units LEL measurement of potentially explosive gas mixtures during manufacturing of solvent-based products Cleanliness and quality control of solvent-based coated products Monitoring of workplace environments Monitoring carbon content in ambient air for leak detection from containers filled with solvent-based products Exhaust gas analysis from combustion engines 2 SICK MAIHAK EurOFID

Measuring Principle, Customer Advantages Measuring principle The gas concentration is converted into an electrical signal by means of a flame ionization detector (FID). In the FID a hydrogen flame burns in the presence of hydrocarbon-free combustion air. When the sample containing hydrocarbon molecules reaches the center of the flame, the molecules are cracked and stripped causing CH fragments to form. These fragments are oxidized by the oxygen in the combustion air and the CHO+ ions form. The ion current is measured and is proportional to the carbon ratio in the organic compounds in the sample. The sample gas is extracted from the process through the sample gas filter by means of a dual-stage jet. Sample gas is then diluted and compressed and passed on to the bypass. All parts in contact with the sample gas are heated in the sensor block to a constant temperature. The dilution rate depends only on the pressures in the jet device. These values are measured continuously by pressure sensors P1, P2 and P3. The propellant pressure of the jet device is set to a specific value. An ejector characteristic field is used to calculate the dilution from the pressure ratios. A portion of the diluted sample gas flows to the FID detector which continuously measures the gas concentration. Bypass Sample gas Filter FID Secondary nozzle Primary nozzle P1 P2 P3 Key features and advantages: Integrated sample gas dilution reduces maintenance and increases uptime. This is especially important when measuring high concentration gas mixtures which, under normal conditions, can solidify causing clogging problems. No moving parts no wear and tear, through the use of an ejector pump instead of a mechanical diaphragm pump to transport sample gas. Low maintenance because only the easily accessible sample gas filter needs to be replaced. Ideal detector geometry rigid symmetrical construction of the jet and the cylinder limits the formation of deposits within the analyzer assembly to a large extent. Heating of all of the gas contacted parts insures the prevention of condensation within the analyzer assembly. EU Type Approval according to 94/9/EU as an on-site gas warning instrument to measure hydrocarbon and derivatives in a mixture together with air in the measuring range of 0 100% LEL. BVS 05 ATEX G 005 X Heated sensor block Pressure controller Computer 3 SICK MAIHAK EurOFID

System Component Overview EuroFID modular system Analyzer unit The EuroFID system is both mechanically and electrically modular and comprises the analyzer unit, terminal box and control unit (optional: I/O terminal module). In-line version Panel version (wall mounting) Analyzer unit selection 42 V AC RS422 Terminal box Power supply 24 V DC Control unit 230/115 V AC RS422 I/O module Power supply 230/115 V AC Digital and analog inputs/outputs Process control system (Host) Printer RS232 RS232 Analog inputs/outputs: 4 x 0...10 V; 2 x 0/4...20 ma Digital inputs/outputs: 3 x 24 V DC/10 ma; 8 x 24 V AC/100 ma 4 SICK MAIHAK EurOFID

EuroFID Analyzer Unit The analyzer unit contains the heated sensor block, pneumatic supply and control electronics. The pneumatic supply provides operating gases for ignition, ensures continuous operation of the detector flame and dilution of the sample gas as well as delivery of calibration gases to set H 2 Instrument air Calibration gas the zero and end points. The control electronics include an electrically isolated mains adapter that supplies the required operating voltages The analog and digital input and output signals in the analyzer unit are processed by a micro-controller and electronically isolated for data transfer via a serial RS422 interface. All instrument-specific data from the analyzer unit such as the characteristic curve of the two-stage jet device is stored in the non-volatile memory. The analyzer unit is connected to the control unit via the serial interface. Pneumatic control Process FID Pressure and solenoid valve control FID amplifier Flame control Ignition Pressure monitor Heating Power supply 42 V AC Memory Microcontroller RS422 Heated sensor block Control electronics Analyzer unit in wall (panel) mounting enclosure This type is usually fitted on the mounting plate inside of the measuring cabinet. Sample gas is supplied through a heated line. This configuration provides a cost-effective extractive emission measuring unit. In-line analyzer unit The in-line version is flanged directly to the sampling point. All of the other typical sample conditioning components such as heated lines, gas sampling probe and filter are not required. Short gas paths provide a quick response time of < 1.5 seconds. 5 SICK MAIHAK EurOFID

Control Unit and Analyzer Unit in 19" Design Control unit The control unit is designed according to the recommendations of the Standardization Commission of the European Chemical Industry (NAMUR). It combines all the required features such as self-explainatory menu controlled operation where additional information is available in clear text via the help key. The large backlit liquid crystal display and four light-emitting diodes (Alarm, Failure, Maintenance and OK) provide the operator with a quick overview of the measured values and instrument status. Apart from the interface to the analyzer unit, the control unit also has three additional serial interfaces to connect the I/O termi- nal strip and a laptop, a modem or any other computer or to another control unit. The following operating modes are available for instrument functions: Manual operation Fully automatic operation External control via I/O terminal module The control unit is mounted in a 19 rack with 3 height units (133.5 mm) or optionally a half-size 19 rack with 4 height units. 19" rack (3 HU) Half-size 19" rack (4 HU) Analyzer unit in 19" rack: Example: Standard system cabinet The analyzer unit is integrated in a 19" rack which can be fitted in standard system cabinets. Together with the terminal box integrated in the control unit, the overall height of the complete analyzer is 7 height units. Industrial housing for Ex Zone 1 The In-line EuroFID in stainless steel housing is approved for use in potentially explosive areas in Zone1 (II2G EEx p IIB+H2 XXX C (XXX = 170...220 C)). Terminal box, heating (optional) and /or process gas lock-out are integrated in the pressurized housing. 6 SICK MAIHAK EurOFID

Technical Data Overview EuroFID Technical Data Measured Data Inline Wall housing 19" rack Industrial housing Ex Zone 1 Measurements LEL Process, emission Process emission Process emission Process LEL Measured value display 4 ½ digit and analog as bar graph Measuring range: Smallest measuring range Largest measuring range 6 measuring ranges selectable 10 ppm relative to C 3 H 8 100 vol% Linear range Depends on measuring range, ±1 % within one decade, ±5 % over the whole measuring range. Detection limit 1) 3) < 3 % of measuring range limit value Response time (T 90 ) < 1.5 s (LEL); < 2.5 s (emission) < 2.5 s < 2.5 s < 1.5 s Zero drift < 0.5 % of measuring range end value/month 1) Sensitivity drift < 3% of measuring range end value/month 1) Flow 2) Min. 0.5 l/min, max. 6.2 l/min Connection Stainless steel tube, OD 6 mm, ID 5 mm Pressure range Atmospheric, ± 50 hpa Protection class IP 54 (outer housing) IP 20 IP 20 IP 65 Approvals Gas warning device BVS 05 ATEX G005 X 17 th BImSchV 17 th BImSchV (EN2000/76/EC) 17 th BImSchV (EN2000/76/EC) Gas warning device BVS 05 ATEX G005 X EX approvals II 2 G EEx p IIB+H2 XXX C with XXX = 170... 220 C Influencing parameters Ambient pressure < 0.5 % of measuring range end value 1) /10 hpa Sample gas pressure < 1.0 % of measuring range end value 1) /10 hpa Zero point < 2 % of measuring range end value 1) /10 K Sensitivity < 1 % of measuring range end value 1) /10 K Start-up time < 1.5 hours Analog outputs 2 outputs: 0/4... 20 ma potential-free, load resistance: 500 Ω maximum Auxiliary gases Calibration gas Depending on the measuring task, approximately 80 % hydrocarbon concentration of the measuring range used relative to the propane equivalent in synthetic air Pressure: 3,000 hpa 2), consumption 2) : approx. 3 l/min (only during the calibration process) Instrument air From compressed air lines with a residual hydrocarbon content < 1 % measuring range, max. 4 ppm, without variations, free of condensate. (Dew point at least 10 C under the lowest possible outside temperature to avoid condensation in lines.) Pressure: Min. 4,000 hpa ±500 hpa, consumption 2) : min. 6 l/min, max. 17 l/min Fuel gas Pure hydrogen H 2 or H 2 /He 5.0 or better; residual hydrocarbon content < 0.5 ppm Pressure: 3,000 hpa; consumption: continuously approx. 1.8 l/h H 2 or 3.5 l/h H 2 /He Auxiliary gas connections Clamping ring screw connection for 6 mm pipes Power supply 230 V AC/48... 63 Hz or 115 V AC/48... 63 Hz; Power inputs: Approx. 330 VA during start-up, 280 VA during continuous operation 1) Measuring range limit value = 10 ppm C 3 2) Depending on equipment fitted 3) Under field conditions 7 SICK MAIHAK EurOFID

Analyzers and Process Instrumentation At home in the industrial sector We offer you a choice Around the world to your service SICK Group We can build on years of experience in the field of Analyzers and Process Instrumentation. That is why we are at home in the world of cement and power plants as well as in the chemical and petrochemical sector. Be it emission control at the waste treatment or process optimization for steel manufacturing, SICK MAIHAK offers tailor-made solutions. SICK MAIHAK offers a number of sensor-based techniques for analysis, ranging from the continuous gas and dust measurement to specialized applications for water and liquid analysis. Within the process measurement technology SICK MAIHAK products play a central role in determining volume flow of gases and level of bulk materials. Whereever you are, our global network of subsidiaries and representatives is able to supply qualified support when you need it. We deliver the equipment for your measuring tasks, provide documentation and training. Our highly skilled service staff offers support during installation, commissioning and maintenance of the appliances. SICK MAIHAK represents the process automation segment of the SICK group, one of the worlds leading manufacturer of intelligent sensors and sensor solutions. With its 4,000 em- ploy ees, SICK offers an extensive portfolio of products and services on the market of factory and process automation. www.sick.com 8009777/2006-07 DIV03/KE Printed in Germany (2007-07) Subject to change without prior notice SICK MAIHAK GmbH Analyzers and Process Instrumentation Nimburger Str. 11 79276 Reute Germany www.sick-maihak.com Phone +49 7641 469-0 Fax +49 7641 469-1149 info.sick-maihak@sick.de Analyzers and Process Instrumentation