High-Rate Stormwater Treatment with Up-Flow Filtration

Similar documents
High-Rate Stormwater Treatment with Up-Flow Filtration

FIELD PERFORMANCE FOR UP FLOW FILTRATION DEVICE

Full Scale Up Flo Filter Field Performance Verification Tests

Wet Detention Ponds, MCTTs, and other Options for Critical Area Stormwater Control. Robert Pitt University of Alabama, Tuscaloosa, AL

Full Scale Up-Flo Filter Field Verification Tests

Field Verification Report for the Up-Flo Filter

WEFTEC 2006, Dallas, Texas FULL SCALE EVALUATION OF THE UPFLO TM FILTER - A CATCHBASIN INSERT FOR THE TREATMENT OF STORMWATER AT CRITICAL SOURCE AREAS

Background to Research Leading to Development of Upflow Filtration

Aesthetic (Floatables) and Gross Solids Characteristics of Stormwater

NJCAT TECHNOLOGY VERIFICATION. Up-Flo Filter Hydro International

Conservation Design Approach for New Development

Particulate Transport in Grass Swales

Laboratory Testing Guidelines for Certification of Manufactured Stormwater BMPs

VERIFICATION STATEMENT

Solids Characteristics of Stormwater

VERIFICATION STATEMENT

Evaluating Scour Potential in Stormwater Catchbasin Sumps Using a Full-Scale Physical Model and CFD Modeling. Humberto Avila.

STORMWATER TREATMENT FIELD DEMONSTRATION AND EVALUATION

Capability of the Aqua-Swirl Concentrator to Remove Trash from Stormwater Runoff

PERKFILTER. Design Guide

Errors associated with sampling and measurement of solids: Application to the evaluation of stormwater treatment devices

STORMWATER MANAGEMENT

Table 1: Water Quality Event (WQE) Design Intensities. i 1 (t c 5 min) (in/hr) a b. tc c

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

FULL SCALE LABORATORY EVALUATION OF STORMCEPTOR MODEL STC 450 FOR REMOVAL OF TSS

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

Monitoring. Stormwater NPDES Data Collection and Evaluation Project. Communities Included in NSQD version 3

SmartDrain TM for Enhanced Biofiltration Controls

Chemical and Microbiological Quality of Stormwater Runoff Affected by Dry Wells; A Case Study in Millburn, NJ

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND

Need to Verify Model TSS Reduction Estimates

ENGINEERED SOLUTIONS. CDS Guide Operation, Design, Performance and Maintenance

Treatability of Organic and Radioactive Emerging Contaminants in Stormwater Runoff

Observed infiltration and clogging characteristics for tested media.

Stormwater Manufactured Treatment Devices (MTDs)

Protocol for Total Suspended Solids Removal Based on Field Testing Amendments to TARP Protocol August 5, 2009

NJCAT TECHNOLOGY VERIFICATION. Up-Flo Filter. Hydro International

CHALLENGING URBAN BMP ASSUMMPTIONS. John Moll, CEO

Figure 1. Inlet particle size distributions observed at the Monroe St. (Madison, WI) wet detention pond (WI DNR and USGS).

Don t Throw the Baby Out with the Bathwater Sample Collection and Processing Issues Associated with Particulate Solids in Stormwater

EXHIBIT 2:Optional Online Installation Re-entrainment/scour testing of the Terre Kleen18 Hydrodynamic Separator Stormwater Treatment unit per NJDEP

Introduction. Module 15: Unit Processes for Stormwater Treatment and the Development of Critical Source Area Controls

Integrated Watershed Management in Urban Areas

Conditional Interim Certification Findings

Purification of Stormwater Using Sand Filter

A signed statement from the manufacturer listing the protocol requirements and indicating that all of the requirements were met or exceeded.

Field Evaluation of a Stormceptor Model STC 1200 Westwood, Massachusetts. Prepared by: Stormceptor Group of Companies

Presented at the Water Environment Federation Technical Exposition and Conference, Orlando, FL, 1998.

A Forterra Company Kraken Filter

Fremont Tree Well Filters LID Performance on a Redeveloped Urban Roadway

ACTIVITY: Water Quality Inlets and Media Filtration Inlets ST 06

BMP 6.4.7: Constructed Filter

Best Management Practices for Stormwater Quality Treatment in Urban Settings. Lower Mississippi River WMO September 2017

FABCO INDUSTRIES, Inc STORMBASIN FILTER CARTRIDGE TEST REPORT: CLEAN FLOW RATE OILS AND GREASE EFFECTIVENESS. Prepared by:

VERIFICATION TESTING OF THE HYDROGUARD HG6 HYDRODYNAMIC SEPARATOR STORMWATER TREATMENT UNIT FINAL REPORT. By James T. Mailloux Amie N.

BMP #: Water Quality Inserts

INCLINED PLATE SETTLERS TO TREAT STORMWATER SOLIDS

COMPARISON OF STORMWATER QUALITY TREATMENT GUIDELINES AND CRITICAL STRUCTURAL BEST MANAGEMENT PERFORMANCE FACTORS AND PARAMETERS TO CONSIDER

Vortex Separator. May be more cost-effective pre-treatment devices than traditional wet or dry basins.

Characterizing the Distribution of Particle Sizes in Stormwater Runoff from Ohio s Roadways

WQ-06 SAND FILTER. 1.0 Sand Filter. Greenville County Technical Specification for: 1.1 Description

Dual Media Filtration System for Reducing Pollutants in Storm Water Runoff

STORMFILTER THE MOST PROVEN. stormwater filtration system

Turning Water Around. August 25, Robert Cooper Virginia Department of Environmental Quality 629 Main Street Richmond, VA 23219

Jensen Deflective Separator (JDS) Stormwater Treatment Unit

Evapotranspiration Calculations for Stormwater Quality Models

Evapotranspiration Calculations for Stormwater Quality Models

The Cost of Bias: Redefining Urban Sediment through Improved Sampling Technology

Modeling Green Infrastructure Compared with Large-Scale Monitoring at Kansas City, MO

NJCAT TECHNOLOGY VERIFICATION. Debris Separating Baffle Box (DSBB ) Stormwater Treatment System. Bio Clean Environmental Services Inc.

Attachment 1. Manufactured Treatment Device (MTD) Registration

Stormwater Effects. The Selection of an Urban Runoff Control Program using Decision Analysis. Birmingham, AL, rains from 1952 through 1989

Turning Water Around. August 27, Robert Cooper Virginia Department of Environmental Quality 629 Main Street Richmond, VA 23219

EVALUATION OF UPFLOW FILTERATION FOR THE TREATMENT OF STORMWATER UDAY KHAMBHAMMETTU A THESIS

NJCAT TECHNOLOGY VERIFICATION. Cascade Separator Contech Engineered Solutions

Attachment 1. Manufactured Treatment Device (MTD) Registration

NJCAT TECHNOLOGY VERIFICATION. Bio Clean Environmental Services, Inc. (With April 2016 Addendum)

Removal of Metals from Storm Water Runoff at Industrial Activities

NJCAT TECHNOLOGY VERIFICATION. First Defense HC Stormwater Treatment Device. Hydro International

Aqua-Swirl Stormwater Treatment System

Aqua-Swirl Stormwater Treatment System

Inlet Protection. Fe= (Depends on soil type)

BIOPOD TM BIOFILTER. with StormMix Biofiltration Media. Inspection and Maintenance Guide

4.8. Subsurface Infiltration

Permeable Pavement for Stormwater Management Porous Pavement

Addendum to the Hydro International s Downstream Defender Conditional Interim Certification

Subsurface Infiltration SMP One-Sheet - download a summary of this tool, with quick reference facts for. clients and developers.

Chapter 12 - Emerging Technologies

Chapter 15 Catch Basin Inserts

CEE 371 Water and Wastewater Systems

Turning Water Around. June 4, Robert Cooper Virginia Department of Environmental Quality 629 Main Street Richmond, VA 23219

Urban runoff takes many forms and has highly variable characteristics

Review For Final Exam. Review For Final Exam

DRAFT PTP-06. Activity: Water Quality Units

SAFL Baffle Research Summary

NJCAT TECHNOLOGY VERIFICATION. Hydro International. August, 2015 (Revised Table A-2 January 2017)

CENTRALIZED BMPS TYPICALLY PUBLICLY OWNED & MAINTAINED BMPS, TREATING A LARGE (>20 ACRES) URBAN DRAINAGE WITH MULTIPLE LAND

NJCAT TECHNOLOGY VERIFICATION. Filterra Bioretention System. Americast Inc.

Transcription:

1 High-Rate Stormwater Treatment with Up-Flow Filtration Noboru Togawa and Robert Pitt The objective of this research is to examine the removal capacities of a highrate stormwater filtration device, in part developed by engineers at the University of Alabama through a Small Business Innovative Research grant from the U.S. Environmental Protection Agency. The Up-Flo Filter is an efficient high-rate stormwater filtration technology designed for the removal of trash, sediments, nutrients, metals and hydrocarbons from stormwater runoff. Compared with traditional downflow filtration treatment, upflow filtration can minimize clogging problems while providing a high rate of flow. The Up-Flo filter was developed to remove a broad range of stormwater pollutants, especially those associated with particulates. The high flow rate capacities of the Up-Flo filter are accomplished through controlled fluidization of the filtration media, while still capturing very small particulates, that is located in a flexible, but constraining, media container. The Up-Flo filter also drains down between rain events which minimizes anaerobic conditions in the media and which also partially flushes captured particulates from the media to the storage sump, decreasing clogging and increasing run times between maintenance. Gross floatables are captured through the use of an angled screen before the media and a hood on the overflow siphon, while the sump captures bed load particulates. Monograph 14. Authors, ISBN, copyright and website Leave as is to maintain correct page dimensions

Leave header as is 1.1 Introduction Many types of stormwater controls are available, but most are relatively large or insufficient in their treatment capacity for a range of sediment sizes. Adequate treatment of runoff requires the removal of many types of pollutants, as well as large amounts of debris and floatable materials, over a wide range of flows. Traditional downflow filters, which can provide high levels of treatment, can quickly clog, which reduces their treatment flow rate and overall treatment capacity (Urbonas, 1999). They also usually operate at a low treatment flow rate requiring a large area to treat substantial portions of the runoff from a site. The Up-Flo filter is designed to treat stormwater runoff from critical source areas that discharge especially high levels of pollutants. The commercialized Up-Flo filter minimizes clogging and was developed to remove a broad range of stormwater pollutants at a relatively high rate, and can be easily retrofitted into existing stormwater drainage. This chapter presents the results from a controlled full-scale field evaluation located at a parking lot in Tuscaloosa, Alabama. Treatment flow rates, particle size controls, and suspended solid concentration reductions will be stressed in this presentation. 1.2 Location and Size of Filter A 2.1 m (7 ft) tall, 1.2 m (4 ft) diameter standard inlet containing a six module Up-Flo Filter has been installed at the Riverwalk parking lot near the riverboat Bama Belle on the Black Warrior River in Tuscaloosa, Alabama. The chamber is a conventional concrete manhole with a sump, with the Up- Flo filter components installed. The filter receives surface runoff from a parking lot, road, sidewalks, and a small landscaped area, as shown in Table 1.1. The total drainage area tributary to the device is approximately 359 m 2 (.9 acres). Figure 1.1 shows the drainage area and the location of the test site.

Leave header as is Table 1.1 Drainage area land use. Land Use Area (m 2 ) % of Land Use Parking Area 11 3.5 Other Paved 121 3.4 Side Walks 194 5.4 Entrance Road 12 28. 5 Green Space 116 32.2 Total 359 1. Inlet Location Figure 1.1 Site map and drainage area. 1.3 Description of Filter The full-scale filter system (having a full complement of 6 filter modules) was installed and is being tested to confirm the initial pilot-scale test results under actual rain conditions. Hydraulic capacity and pollutant removal capabilities in the full-scale field installation are being monitored under both controlled and actual runoff conditions. Figure 1.2 shows the main features of the Up-Flo filter, while Figure 1.3 shows the installation of the full-scale

Leave header as is test filter at Tuscaloosa. Depending on the selected media, the filtration treatment flow rate varies from 25 L/min/m 2 to 12 L/min/m 2 (5 to 25 gal/min/ft 2 ). With 6 modules, each having about.9 m 2 (1 ft 2 ) of filter surface, the total treatment flow rate for this installation is expected to be at least 38 L/min (1 gal/min). Figure 1.4 shows the treatment flow rate requirements for typical southeastern US conditions, based on continuous simulations (Pitt and Khambhammettu 26). The 38 L/min (1 gal/min) for the test site is expected to treat about 9% of the annual flow for a typical rain year, with about 1% of the annual flow bypassing filtration. Figure 1.2 Up-Flo Filter components (drawing from Hydro International).

Leave header as is Figure 1.3 Installation of Tuscaloosa Up-Flo Filter. 1 Percent of Annual Flow Treated (Atlanta 1999) 9 8 7 6 5 4 3 2 1 1 1 1 Treatment Flow Rate (gpm per acre of pavement) Figure 1.4 Treatment flow rate requirements for southeast US paved conditions (example shown for continuous simulation results for Atlanta, Georgia).

Leave header as is 1.4 Controlled Flow Test and Controlled Particle Capture Test This section describes the initial controlled performance monitoring that was conducted at the Riverwalk parking lot near the Bama Belle in Tuscaloosa, Alabama. The first flow test was conducted for the purpose of determining the hydraulic capacity and the pollutant removal capabilities in a full-scale field installation under controlled conditions. In the test, the filtration rate of the CPZ Mix filter medium, a proprietary mixture of bone char activated carbon, peat moss, and manganese-coated zeolite was evaluated. Based on results of prior lab scale testing, the mixed medium is expected to have high pollutant removal at relatively high filtration rates (Clark and Pitt 1999). The Up-Flo Filter was fitted with two media bags in each of the 6 chambers, for a total of 12 bags, as well as the flow distribution material placed above and below the media bags. 1.5 Methodology for the Evaluation of Filtration Rate Flow tests were conducted in the field with the cooperation of the Tuscaloosa Department of Transportation by using a pump to deliver Black Warrior River water to a flow splitter/flow controlling barrel. The water flow rate was measured by recording the time needed to fill a known volume (Figure 1.5). When the rate was established, the volume tray was removed, directing the known and steady flow to the gutter immediately above the Up- Flo intake. For each flow rate, measurements were taken of the steady-state water depth in the filter and the reported flow rate from the area-velocity sensor that was used to monitor the flow during rain events. The measurements were repeated 5 times for each flow to reduce the errors. Figure 1.6 shows a flow vs. head graph developed during these tests.

Leave header as is Figure 1.5 Pumped river water is discharged from splitter barrel to the 42 L (11 gal) plastic tray. Head (in) vs. Flow Rate (gal/min) Flow Rate (gal/min) Upper Confidence in 95% Lower Confidence in 95% Actual Data Linear (Actual Data) 65 6 55 y = 2.865x R 2 =.9646 5 45 4 35 3 25 2 15 5 7 9 11 13 15 17 19 21 Head (in) Figure 1.6 Example of a flow vs. head graph for mixed media filters, showing repeatable measurements.

Leave header as is 1.6 Particle Size Distribution of Tested Media and Test Sediment The test sediment in the stormwater simulation used a mixture of SIL-CO- SIL 25, SIL-CO-SIL 16 (both from U.S. Silica Co.), and coarse and fine concrete sands. The mixture was made by mixing the four components in specific ratios to obtain a relatively even particle size distribution representing the complete range from about 2 to 2, μm. This mixture was not intended to represent actual stormwater (which usually has a smaller median particle size), but to ensure sufficient amounts of large particles so they could be accurately monitored to quantify their removal. As shown later, all of the results of these controlled tests were presented based on many narrow particle size ranges so they could be applied to any expected particle size distribution of the flowing water. Since the samples were all analyzed using sieves and a Coulter Counter, the results are much more useful than if total event SSC (suspended sediment concentration) analyses alone were conducted representing all sizes combined. If a single analysis was conducted, then the particle size distribution (PSD) of the challenge water would have to match the stormwater PSD, a difficult objective given the highly variable particle size characteristics of stormwater, and the results could not be easily extrapolated to other PSD conditions. Figure 1.7 shows the particle size distributions of two of the test mixtures that were used during the tests. Mixture Particle Distribution Mixture 5 PSD for 25 gal/min 1 8 % Finer (%) 6 4 2 1 1 1 1 Sieve Size (µm) Figure 1.7 Particle size distribution of mixture used for the flow test.

Leave header as is 1.7 Test Methodology for Controlled Sediment Capture Tests The tests described below used several known concentrations of particulate solids over a wide range of particle sizes and an influent flow rate that averaged 91 L/min (24 gal/min) (having a standard deviation of.3 gal/min). Each experiment was conducted for 3 minutes, during which time measured aliquots of the dry sediment were constantly poured into the pumped influent river flow from the Black Warrior River. River water was also collected before any sediment was added to measure the background solids in the test water to determine the background conditions. Effluent samples were collected using a dipper grab sampler every 1 minute and composited in a churn sample splitter during the 3 minutes test period. The effluent was sampled at a completely mixed cascading flow exiting the filter in a specially constructed sampling chamber. Using the churn splitter, two samples of 1 ml each were placed in sample bottles for duplicate laboratory PSD and SSC analyses for each test. In preparation for the tests, test sediment portions were pre-weighed in 5 ml polyethylene bottles. The sediment was manually fed into the influent water over the whole period of each experiment, according to the desired particulate solids concentration for the specific flow rate for each test (Figure 1.8). This method ensured that all of the sediment and all particle sizes entered the test chamber. Depth readings of the water levels were also taken during each experiment to determine the head loss during the Up-Flo Filter operation. Also, after completion of each experiment, additional multiple flow and depth readings were taken to determine the final flow rate and available head to detect any change in filtration rate during the test. During these tests, four different influent sediment concentrations were tested: 5 mg/l, 1 mg/l, 25 mg/l and 5 mg/l. Later tests also examined other flow rates and other treatment media.

Leave header as is Figure 1.8 Sediment mixture was manually and consistently added to the Influent water over the 3 minutes test period. 1.8 Initial Controlled Test Result of Filter Controlled tests can measure the filter behavior under known conditions. Mixtures of ground silica available from U.S. Silica Co. were used for these initial tests, reflecting filter performance for a variety of particle sizes. Figures 1.9 to 1.18 show the influent and effluent concentrations during tests using 5 to 5 mg/l influent conditions. Further controlled tests are being conducted, along with measurements conducted during actual rain conditions. Tables 1.2 and 1.3 summarize the average influent and effluent concentrations, along with the percentage reductions for 1 and 5 mg/l influent conditions (including river water additions). Table 1.4 shows the average influent and effluent concentration of total dissolved solids (TDS) concentrations.

Leave header as is 5 mg/l 1 mg/l Total Suspended Solids (mg/l) 6 5 4 3 2 1 Influent Concentration 25 mg/l 5 mg/l Effluent Concentration Figure 1.9 Performance Plot for Mixed Media on Total Suspended Solids for 25 gallon/min Flow Rate. 5 mg/l 1 mg/l.45~3 μm Solids (mg/l) 3 25 2 15 1 5 Influent Concentration 25 mg/l 5 mg/l Effluent Concentration Figure 1.1 Performance Plot for Mixed Media on.45~3 μm Particulate Solids for 25 gallon/min Flow Rate.

Leave header as is 5 mg/l 1 mg/l 3~12 μm Solids (mg/l) 1 9 8 7 6 5 4 3 2 1 Influent Concentration 25 mg/l 5 mg/l Effluent Concentration Figure 1.11 Performance Plot for Mixed Media on 3~12 μm Particulate Solids for 25 gallon/min Flow Rate. 5 mg/l 1 mg/l 12~3 μm Solids (mg/l) 16 14 12 1 8 6 4 2 Influent Concentration 25 mg/l 5 mg/l Effluent Concentration Figure 1.12 Performance Plot for Mixed Media on 12~3 μm Particulate Solids for 25 gallon/min Flow Rate.

Leave header as is 5 mg/l 1 mg/l 3~6 μm Solids (mg/l) 9 8 7 6 5 4 3 2 1 Influent Concentration 25 mg/l 5 mg/l Effluent Concentration Figure 1.13 Performance Plot for Mixed Media on 3~6 μm Particulate Solids for 25 gallon/min Flow Rate. 5 mg/l 1 mg/l 6 25 mg/l 5 mg/l 6~12 μm Solids (mg/l) 5 4 3 2 1 Influent Concentration Effluent Concentration Figure 1.14 Performance Plot for Mixed Media on 6~12 μm Particulate Solids for 25 gallon/min Flow Rate.

Leave header as is 5 mg/l 1 mg/l 12~25 μm Solids (mg/l) 1.8 1.6 1.4 1.2 1..8.6.4.2. Influent Concentration 25 mg/l 5 mg/l Effluent Concentration Figure 1.15 Performance Plot for Mixed Media on 12~25 μm Particulate Solids for 25 gallon/min Flow Rate. 25~118 μm Solids (mg/l) 16 14 12 1 8 6 4 2 5 mg/l 1 mg/l 25 mg/l 5 mg/l Influent Concentration Effluent Concentration Figure 1.16 Performance Plot for Mixed Media on 25~118 μm Particulate Solids for 25 gallon/min Flow Rate.

Leave header as is > 118 μm Suspended Solids (mg/l) 35 3 25 2 15 1 5 5 mg/l 1 mg/l 25 mg/l 5 mg/l Influent Concentration Effluent Concentration Figure 1.17 Performance Plot for Mixed Media on > 118 μm Particulate Solids for 25 gallon/min Flow Rate. 5 mg/l 1 mg/l Total Dissolved Solids (mg/l) 3 25 2 15 1 5 Influent Concentration 25 mg/l 5 mg/l Effluent Concentration Figure 1.18 Performance Plot for Mixed Media on Total Dissolved Solids for 25 gallon/min Flow Rate.

Leave header as is Table 1.2 Average influent and effluent concentration for 25 gal/min and 1 mg/l concentration. Particle Size (μm) Average Influent Concentration (mg/l) Average Effluent Concentration (mg/l) Average Reduction (%) <.45 22 16 27.45 to 3 5.2 1.1 78 3 to 12 19 11 38 12 to 3 26 8.3 68 3 to 12 16 1.3 92 12 to 118 28.18 99 > 118 5.7 1 sum >.45 μm 99 21.9 78 Table 1.3 Average influent and effluent concentration for 25 gal/min and 5 mg/l concentration. Particle Size (μm) Average Influent Concentration (mg/l) Average Effluent Concentration (mg/l) Average Reduction (%) <.45 24 12 49.45 to 3 26 3.2 88 3 to 12 92 32 65 12 to 3 13 28 79 3 to 12 81 3.9 95 12 to 118 142.55 1 > 118 3 1 sum >.45 μm 5 67.7 86 Table 1.4 Average influent and effluent concentration for 25 gal/min and total dissolved solids. Test (SSC Concent.) Average Influent TDS Concent. (mg/l) Average Effluent TDS Concent. (mg/l) Average Reduction (%) Maximum Reduction (%) Minimum Reduction (%) 5 23 19 19 28 13 1 22 16 27 42 15 25 23 17 25 35 13 5 24 12 49 55 39

Leave header as is 1.9 Conclusion The Up-Flo filter is an efficient high-rate filtration device designed for the treatment of stormwater runoff from critical source areas. In this chapter, the hydraulic capacity and the particulate removal capabilities under controlled conditions are examined. During the controlled sediment tests of the full-sized treatment system, 9 to 1% of the particles larger than 3 µm, and from 4 to 9% of the smaller particles were captured, irrespective of the influent concentrations. These are similar results to those observed during the prior pilot-scale tests during actual rains (Pitt and Khambhammettu 26). During the tests having about 1 mg/l influent SSC, the effluent averaged about 2 mg/l, with removal rates of about 8%. During tests using 5 mg/l SSC influent, the effluent averaged about 65 mg/l, with about 85% removal rates. During these initial tests, the treatment flow rates vs. head were very repeatable, with maximum flows being about 55 gal/min with 2 inches of head with the tested media mixture. Later tests examined treatment flow rates greater than 1 gpm with similar particulate removal results. Additional controlled tests have been conducted using other media, SSC concentrations, and flow rates, but the results are not available to present in this paper. In the future, pollutant removal including sediment, particle sizes, metals, nutrients, and bacteria will be tested during actual storm events. References Clark, S. and Pitt, R. (1999). Stormwater Treatment at Critical Areas, Vol. 3: Evaluation of Filtration Media for Stormwater Treatment. U.S. Environmental Protection Agency, Water Supply and Water Resources Division, National Risk Management Research Laboratory. EPA/6/R-/16, Cincinnati, Ohio. 442 pgs. October 1999. Pitt, R. and Khambhammettu, U. (26). Field Verification Report for the Up-Flo Filter. Small Business Innovative Research, Phase 2 (SBIR2) Report. U.S. Environmental Protection Agency, Edison, NJ. 275 pages. March 26. Urbonas, B. (1999). Design of a Sand Filter for Stormwater Quality Enhancement. Water Environment Research, 71(1), 12-113.