LanthaScreen Terbium-Labeled TR-FRET Anti-Epitope Tag Reagents - User Guide

Similar documents
LanthaScreen Terbium Labeled TR-FRET Secondary Antibody Reagents-User Guide

6. Assessing Data Quality in Ratiometric Measurements Related Products References Notice to Purchaser... 8

LanthaScreen TR-FRET Retinoic X Receptor alpha Coactivator Assay

LanthaScreen TR-FRET Liver X Receptor alpha Coactivator Assay

LanthaScreen TR-FRET Estrogen Receptor beta Coactivator Assay

LanthaScreen TR-FRET Androgen Receptor T877A Coactivator Assay

Adapta Universal Kinase Assay User Guide

Technical Manual. Transcreener KINASE TR-FRET Assay

LanthaScreen TR-FRET Coregulator Protocol and Assay Conditions Revised 31-Jul-2017

LanthaScreen TR-FRET Estrogen Receptor alpha Competitive Binding Assay

ADP TR-FRET Green Assay

LanthaScreen TR-FRET Retinoid-Related Orphan Receptor alpha Coactivator Assay

LanthaScreen TR-FRET Retinoid-Related Orphan Receptor gamma Coactivator Assay

LyticBLAzer -FRET B/G Kit Protocol

Z -LYTE KINASE ASSAY KIT TYR 3 PEPTIDE PROTOCOL

Transcreener PDE Assay

FAR RED FP. GDP FP Assay. Technical Manual. v071814

Test Your Plate Reader Set-up Before Using LanthaScreen Eu Assays

Comparison of LANCE Ultra TR-FRET to PerkinElmer s Classical LANCE TR-FRET Platform for Kinase Applications

Z -LYTE KINASE ASSAY KIT SER/THR 9 PEPTIDE PROTOCOL

Technical Manual. Transcreener KINASE Assay Transcreener KINASE Plus Assay

FAR RED FP. UDP FP Assay. Technical Manual. v042809

SAH Methyltransferase TR-FRET Assay

PolarScreen Tyrosine Kinase Assay Kit, Far Red Protocol

SAH Methyltransferase TR-FRET Assay

E1/E2 LITE - Ubiquitin Transfer Assay Kit. Catalog Number UC106

LanthaScreen Europium Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers

A Comparison of PerkinElmer s LANCE camp Assay Performance to that of State of the Art Competitive Technologies

DELFIA, LANCE and TruPoint technologies Sensitivity and dynamic range using PerkinElmer instrumentation and microplates

Goat Anti Rabbit IgG Antibodies

Z -LYTE fluorescent kinase assay technology. Z -LYTE Kinase Assay Platform

E1 LITE - UBE1 Activity Assay Kit. Catalog Number UC105

EnzChek Phospholipase A 2 Assay Kit

Synergy NEO HTS Multi-Mode Microplate Reader and Life Technologies Reagents

CD47 / SIRP ALPHA BINDING ASSAY KITS

Optimization of a LanthaScreen Kinase assay for DNA-PK

Measure-iT Thiol Assay Kit (M30550)

Comparison of HTRF compatible microplate readers from Tecan Ultra Evolution, GENios Pro & Safire² - camp HiRange kit

FAR RED FP. ADP 2 FP Assay. Technical Manual. v100708

LANCE TR-FRET IMMUNOASSAY CONVERSION. LANCE TR-FRET Immunoassay Conversion Guide

IMAP TR-FRET Phosphodiesterase Evaluation Assay Kit With Progressive Binding System Quantity: 800 test points (20 L reactions)

Adapta Assay Setup Guide on the BioTek Instruments Synergy 2 Multi-Mode Microplate Reader

Optimization of a LanthaScreen Kinase assay for BRAF V599E

HTRF (Cisbio) Human Interleukin beta (IL1β) assay Tecan Infinite F500, TR-FRET (HTRF )

Fluo-4 NW Calcium Assay Kits (F36205, F36206)

Zenon Goat IgG Labeling Kits

Developing a Time-Resolved Fluorescence Resonance Energy Transfer (TR-FRET) Assay

HTRF KinEASE STK discovery kit

Optimization of an Adapta Kinase Assay for Cdk9/cyclin T1

AlphaLISA C-tag Acceptor Beads

Setup for LanthaScreen Terbium Assays on SpectraMax M5/M5e Microplate Reader with SoftMax Pro 6 Software

Quant-iT dsdna Broad-Range Assay Kit

HTRF KinEASE-STK S3 kit

Application Note. Quench Correction for LANCE Time-Resolved Fluorescence Resonance Energy Transfer LANCE.

EGF and EGFR (Human) Binding LANCE Ultra Kit

Biochemical Binding ADCC Assays Utilizing LANCE Toolbox Reagents for the Characterization of higgs and FcγR1A

Zen Myeloperoxidase (MPO) ELISA Kit

ThiolTracker Violet (Glutathione Detection Reagent)

Calcium Assay Kit. Technical Data Sheet. Product Information. Description. Storage. Materials not included

Generic DELFIA Reagents

How to run Alpha assay: How to setup an Alpha assay Make your own assay!

Tyrosine Kinase Assay Kit, Red*

Table of Contents. BacMam ERK2 [pthr185/ptyr187] Cellular Assay User Guide. Catalog no. A12888 Shipping: Varies Storage: Varies

Violet Chromatin Condensation/Dead Cell Apoptosis Kit with Vybrant DyeCycle Violet and SYTOX AADvanced for Flow Cytometry

Development of an AlphaLISA Assay for Screening Inhibitors of the TIM-3/Gal-9 Interaction

CellSensor Lentiviral Vectors User Guide

Amplex UltraRed Reagent

LANCE Ultra Lambda Light Chain (Human) Detection Kit

LANCE Ultra Kappa Light Chain (Human) Detection Kit

Vybrant DyeCycle Green and Orange Stains

Anti-6xHis AlphaLISA Acceptor Beads

Anti-6xHis AlphaLISA Acceptor Beads

Development of an AlphaLISA MEK1 Kinase Assay Using Full-Length ERK2 Substrate

LANCE Ultra Cortisol Detection Kit

ADP 2 TR-FRET Red Assay

Anti-V5 AlphaLISA Acceptor Beads

Vybrant DyeCycle Violet stain

Chinese Hamster Ovary Cell Host Cell Proteins (CHO HCP) (broad reactivity) LANCE Ultra Detection kit

Protocol part no. PV5116.pps Rev. date: 14 April 2008

Part. no. PV4319.pps Rev. date 29 June 2006

HUMAN PRO-COLLAGEN TYPE I KITS

High Throughput Quantitation of Cytokine Biomarkers using LANCE Ultra TR-FRET Assays

The Flagship for High-Throughput Screening

TAF1 bromodomain 1 TR-FRET Assay Kit. Item No

RED FI. ADP 2 FI Assay. Technical Manual. Instructions for Part Numbers 3013-A, K, and K TM#133 Rev

Research Reagents. Anti-Mouse IgG Acceptor Beads

AlphaScreen SureFire STAT3 Total Assay Kits. Manual

TAF1 bromodomain 1 TR-FRET Assay Kit

Human Transferrin LANCE Ultra Detection kit

Human C-Reactive Protein (CRP) LANCE Ultra Detection Kit

Human α-synuclein Aggregation Kit 500 tests

SelectFX Alexa Fluor 488 Peroxisome Labeling Kit

AlphaScreen SureFire IKK β (p-ser177/181) Assay Kits. Quick Guide

CORTISOL KITS PROTOCOL

AlphaScreen SureFire Histone H3 (p-ser10) Assay Kits. Manual

Simple Conversion of ELISA to PerkinElmer s High Sensitivity DELFIA Technology

AlphaScreen SureFire EGF Receptor (p-tyr1068) Assay Kits. Manual

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Biochemical Binding ADCC Assays Utilizing AlphaLISA Toolbox Reagents for the Characterization of higgs and FcγR1A

Transcription:

LanthaScreen Terbium-Labeled TR-FRET Anti-Epitope Tag Reagents - User Guide Cat. nos. PV3568, PV3569, PV4216, PV4217 Shipping Condition: Frozen Storage: -20 C Lit. no. PV421X.pps Rev. Date: 30 Aug 2005 Table of Contents Table of Contents... 1 Reagents Available... 1 Introduction... 2 Principle of FRET and TR-FRET...2 Difference Between FRET and TR-FRET...2 Use of Terbium as Donor Species...2 Instrument Settings... 3 Excitation and Emission Spectra...3 Excitation Filter...3 Fluorescein Emission Filter...3 Terbium Emission Filter...3 Other Instrument Settings...3 Applications of Anti-Epitope Tag Antibodies to Nuclear Receptor Assays... 4 Using and Detecting Epitope Tags...4 Determining Antibody concentration...4 Assay stability and read window...5 First Time User... 5 Assessing Data Quality in Ratiometric Measurements... 5 Related Products... 6 Notice to Purchaser... 7 Limited Use Label License No. 176: Lanthanide Chelates...7 Limited Use Label License No. 178: Lifetime-resolved assay procedures...7 Reagents Available Reagents Size Cat. no. LanthaScreen Tb-anti-His-Tag Antibody Kit LanthaScreen Tb-anti-GST Antibody Kit 25 µg PV3568 1 mg PV3569 25 µg PV4216 1 mg PV4217 For a list of components in each kit, please refer to the certificate of analysis provided with each kit. The performance of this product is guaranteed for six months from the date of purchase if stored and handled properly.

Invitrogen LanthaScreen Terbium-Labeled TR-FRET Anti-Epitope Tag Reagents - User Guide PV421X.pps Rev. 08/05 Page 2 of 7 Introduction Principle of FRET and TR-FRET For screening libraries of compounds, time-resolved fluorescence resonance energy transfer (TR-FRET) is a recognized method for overcoming interference from compound autofluorescence or light scatter from precipitated compounds. The premise of a TR-FRET assay is the same as that of a standard FRET assay: when a suitable pair of fluorophores are brought within close proximity of one another, excitation of the first fluorophore (the donor) results in energy transfer to the second fluorophore (the acceptor). An increase in the fluorescence emission of the acceptor coupled with a decrease in the fluorescence emission of the donor demonstrates energy transfer between the donor and acceptor. In high throughput screening (HTS) assays, using a ratio of the intensities of the acceptor and donor fluorophores corrects for differences in assay volumes between wells, and corrects for quenching effects because of colored compounds. Difference Between FRET and TR-FRET TR-FRET assays use a long-lifetime lanthanide chelate as the donor species. Lanthanide chelates are unique in that their excited state lifetime (the average time that the molecule spends in the excited state after accepting a photon) is a millisecond or longer. This is in sharp contrast to the lifetime of common fluorophores used in standard FRET assays, which are typically in the nanosecond range. Because interference from autofluorescent compounds or scattered light is also on the nanosecond timescale, these factors negatively impact standard FRET assays. To overcome these interferences, perform TR-FRET assays by measuring FRET after a suitable delay, typically 50 to 100 microseconds, after excitation by a flashlamp excitation source in a microtiter plate reader. This delay not only overcomes interference from background fluorescence or light scatter, but also avoids interference from direct excitation because of the noninstantaneous nature of the flashlamp excitation source. Use of Terbium as Donor Species The most common lanthanides used in TR-FRET assays for HTS are terbium and europium. Terbium offers unique advantages over europium when used as the donor species in a TR-FRET assay. In contrast to europium-based systems that use allophycocyanin (APC) as the acceptor, terbium-based TR-FRET assays use common fluorophores such as fluorescein as the acceptor. Because it is straightforward (and inexpensive) to label a molecule such as a peptide with fluorescein, directly labeled biomolecules may be used in terbium-based TR-FRET assays, rather than biotinylated molecules that must then be indirectly labeled via streptavidin-mediated recruitment of APC. The use of directly labeled molecules in a terbium-based TR-FRET assay reduces costs, improves kinetics, avoids problems because of steric interactions involving large APC conjugates, and simplifies assay development since there are fewer independent variables requiring optimization in a directly labeled system.

Invitrogen LanthaScreen Terbium-Labeled TR-FRET Anti-Epitope Tag Reagents - User Guide PV421X.pps Rev. 08/05 Page 3 of 7 Instrument Settings Excitation and Emission Spectra The excitation and emission spectra of terbium and fluorescein are shown below in Figure 1. Four sharp emission peaks characterize the terbium emission spectrum, with silent regions between each peak. The first terbium emission peak (centered between approximately 485 and 505 nm) overlaps with the maximum excitation peak of fluorescein. Energy transfer to fluorescein is then measured in the silent region between the first two terbium emission peaks. 110 100 90 Fluorescein 80 Terbium 70 60 50 40 30 20 10 0 300 350 400 450 500 550 600 650 Wavelength (nm) Figure 1: Excitation and emission spectra of fluorescein and terbium. Excitation/Emission Spectra of Terbium and Fluorescein Excitation Filter The terbium donor is excited using a 340 nm excitation filter with a 30 nm bandpass. However, the exact specifications of the excitation filter are not critical, and filters with similar specifications will work well. In general, excitation filters that work with europium-based TR-FRET systems will perform well with the LanthaScreen terbium chelates. Fluorescein Emission Filter The specifications of this emission filter are more critical than those of the excitation filter. To measure energy transfer to fluorescein without interference from terbium, use a filter centered at 520 nm with a 25 nm bandpass. We do not recommend standard fluorescein filters because such filters also pass light associated with the terbium spectrum. Terbium Emission Filter In addition, the emission of fluorescein because of FRET is referenced (or ratioed ) to the emission of the first terbium peak using a filter that isolates this peak. Use a filter centered at 490 or 495 nm, with a 10 nm bandpass. In general, a 490 nm filter will reduce the amount of fluorescein emission that bleeds through into this measurement, although instrument dichroic mirror choices (such as those on the Tecan Ultra Evolution instrument) may necessitate the use of a 495 nm filter. The effect on the quality of the resulting measurements is minimal in either case. Filters suitable for LanthaScreen assays are available from Chroma (www.chroma.com) as filter set PV001, or from other vendors. A LanthaScreen filter module for the BMG LABTECH PHERAStar is available direct from BMG. Other Instrument Settings Other instrument settings are typical to the settings used with europium-based technologies. Use the guidelines provided by the instrument manufacturer as a starting point for optimization. For a LanthaScreen assay, a delay time of 100 µs, followed by a 200 µs integration time, are typical. The number of flashes or measurements per well is highly instrumentdependent and is set as advised by your instrument manufacturer. Most filter-based instruments capable of timeresolved FRET, such as the Tecan Ultra Evolution, BMG PHERAStar, Molecular Devices Analyst, or PerkinElmer EnVision are suitable for LanthaScreen assays. In addition, monochromator-based instruments such as the Tecan Safire 2TM are also suitable for LanthaScreen assays. Contact Technical Support for instrument-specific setup guidelines.

Invitrogen LanthaScreen Terbium-Labeled TR-FRET Anti-Epitope Tag Reagents - User Guide PV421X.pps Rev. 08/05 Page 4 of 7 Applications of Anti-Epitope Tag Antibodies to Nuclear Receptor Assays Using and Detecting Epitope Tags Epitope tags facilitate the purification of proteins for use in many different applications. In addition, such tags indirectly label proteins through the use of LanthaScreen terbium-labeled anti-epitope tag antibodies. Indirect labeling of a protein through the use of an anti-epitope tag antibody is advantageous when working with partially purified protein, or in cases in which direct labeling of the protein using amine-reactive terbium (Tb) chelates negatively impacts protein activity. An example of an application using such a labeling strategy is shown schematically in Figure 2. Tb-labeled anti-gst antibody indirectly labels the GST-tagged RXR-beta ligand-binding domain. Titrating the receptor with the agonist 9-cis retinoic acid recruits a fluorescein labeled peptide, PGC1a, which binds to the receptor upon 9-cis retinoic acid-induced conformational changes. Figure 2: Schematic illustration of the use of a terbium-labeled anti-gst antibody in a nuclear hormone receptor assay. The binding of the fluorescein labeled peptide causes an increase in the TR-FRET signal, as is illustrated in the data shown in Figure 3. Such a system characterizes agonist affinity for the receptor or could be configured to identify additional agonists or antagonists. 2.0 1.5 520/495 1.0 0.5 +9-cis RA 0.0 0.001 0.01 0.1 1 10 100 1000 10000 log [9-cis RA] (nm) Figure 3: Titration of the agonist 9-cis retinoic acid into 10 nm RXR-β, 5 nm Tb-anti-GST Antibody and 350 nm Fluorescein-PGC1a peptide with a 1 hour incubation. Read on a Tecan Ultra Evolution. There is a range of variables associated with developing a TR-FRET assay utilizing Tb-labeled anti-epitope antibodies. Determine the reagent concentrations, order of reagent addition, incubation times, etc., for each application. Determining Antibody Concentration The optimal amount of antibody used will depend on the amount of tagged protein in the assay. Too little terbiumlabeled antibody causes lack of signal while too much antibody increases background. Either too much or too little antibody may decrease the read window. We recommend determining the optimal concentration of antibody by using 0.5, 1, 2, and 4 X concentrations of the epitope-tagged protein.

Invitrogen LanthaScreen Terbium-Labeled TR-FRET Anti-Epitope Tag Reagents - User Guide PV421X.pps Rev. 08/05 Page 5 of 7 Assay Stability and Read Window For a given assay system, assess signal stability and read window. In general, many assays will reach equilibrium within 2 hours, and will show a stable signal for at least 8 hours. However, depending on assay configuration and the specific demands of the assay, these times may vary and must be determined experimentally for the given assay system. First Time User Included in each terbium-labeled anti-epitope tag antibody kit is a corresponding fluorescein-labeled positive control. To verify proper instrument settings to run the LanthaScreen assay, we recommend that a dilution series of the fluoresceinlabeled positive control be titrated against a fixed concentration of terbium-labeled antibody to generate a binding curve. The certificate of analysis provided with each antibody kit shows a binding curve that is representative of the data obtained in conducting such an experiment. For example, Figure 4 shows the result of a titration of Fluorescein-GST- Maltose Binding Protein (MBP) against 2 nm Tb-labeled Anti-GST Antibody. The plate was read on a Tecan Ultra Evolution plate reader after a 1 hour room temperature incubation. 2.0 TR-FRET Ratio 1.5 1.0 0.5 0.0 0.001 0.01 0.1 1 10 100 1000 Fl-GST-MBP (nm) Figure 4: Titration of Fluorescein-GST MBP into Tb-Anti-GST antibody on a Tecan Ultra Evolution. Assessing Data Quality in Ratiometric Measurements The TR-FRET value is a unitless ratio derived from the underlying donor and acceptor signals, which are dependent on instrument settings (such as instrument gain). The TR-FRET ratio and the resulting top and bottom of an assay window will depend on these settings as well, and will vary from instrument to instrument. Figure 5 below demonstrates the pitfalls of simply relying on the assay window as a measure of data quality. Normalizing the ratiometric data on the left and re-plotting the data on the right shows that the data is identical in quality (despite vastly different assay windows). What is important in determining the quality of an assay is not the size of the window as much as the size of the errors in the data relative to the difference in the maximum and minimum values. For this reason, the Z prime (Z ) value proposed by Zhang and colleagues (J Biomol Screen 1999: 4(2) pp 67-73), which takes these factors into account, is the correct way to assess data quality in a TR-FRET assay. Typically, our assays have Z values of greater than 0.70. A 520:495 Ratio 1.25 1.00 0.75 0.50 0.25 Ratiometric Data Instrument 1 Instrument 2 Instrument 3 B % TR-FRET 100 75 50 25 Normalized Data 0.00 0.001 0.01 0.1 1 10 100 Tracer (nm) 0 0.001 0.01 0.1 1 10 100 Tracer (nm) Figure 5: Assay window variability because of instrument type (A) does not affect the resulting data. Upon normalization, the above three curves are identical (B).

Invitrogen LanthaScreen Terbium-Labeled TR-FRET Anti-Epitope Tag Reagents - User Guide PV421X.pps Rev. 08/05 Page 6 of 7 Related Products Reagents Amount Cat. No. 25 µg PV3765 LanthaScreen Tb-anti-Mouse Antibody 1 mg PV3767 LanthaScreen Tb-anti-Goat Antibody LanthaScreen Tb-anti-Rabbit Antibody LanthaScreen Tb-anti-Human Antibody LanthaScreen Tb-PY20 Antibody LanthaScreen Tb-PY72 Antibody LanthaScreen Tb-PY100 Antibody LanthaScreen Tb-PT66 Antibody LanthaScreen Tb-pSer (PKC) Antibody LanthaScreen Tb-IκB pser32 Antibody LanthaScreen Tb-pCrosstide Antibody LanthaScreen Tb-CREB pser133 Antibody LanthaScreen Tb-Streptavidin, 1 mg/ml 25 µg PV3769 1 mg PV3771 25 µg PV3773 1 mg PV3775 25 µg PV3777 1 mg PV3779 25 µg PV3552 1 mg PV3553 25 µg PV3554 1 mg PV3555 25 µg PV3556 1 mg PV3557 25 µg PV3558 1 mg PV3559 25 µg PV3560 1 mg PV3561 25 µg PV3562 1 mg PV3563 25 µg PV3564 1 mg PV3565 25 µg PV3566 1 mg PV3567 50 µg PV3576 1 mg PV3577 Fluorescein-PKC Substrate, 1 mg/ml 1 mg PV3506 Fluorescein-IKK Substrate, 1 mg/ml 1 mg PV3507 Fluorescein-CREBtide Substrate, 1 mg/ml 1 mg PV3508 Fluorescein-Crosstide Substrate, 1 mg/ml 1 mg PV3509 Fluorescein-PTK Substrate 1, 1 mg/ml 1 mg PV3513 Fluorescein-PTK Substrate 2, 1 mg/ml 1 mg PV3511 Fluorescein-Poly GT, 30 µm 1 ml PV3610 Fluorescein-Poly GAT, 30 µm 1 ml PV3611 LanthaScreen Amine Reactive Tb Chelate LanthaScreen Thiol Reactive Tb Chelate 10 µg PV3583 100 µg PV3582 1 mg PV3581 10 µg PV3580 100 µg PV3579 1 mg PV3578

Invitrogen LanthaScreen Terbium-Labeled TR-FRET Anti-Epitope Tag Reagents - User Guide PV421X.pps Rev. 08/05 Page 7 of 7 Notice to Purchaser Limited Use Label License No. 176: Lanthanide Chelates This product is the subject of one or more of US Patents 5,622,821 5,639,615, and 5,656,433 and foreign equivalents. The purchase of this product conveys to the buyer the non-transferable right to use the purchased amount of the product and components of the product in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The buyer cannot sell or otherwise transfer (a) this product (b) its components or (c) materials made using this product or its components to a third party or otherwise use this product or its components or materials made using this product or its components for Commercial Purposes. The buyer may transfer information or materials made through the use of this product to a scientific collaborator, provided that such transfer is not for any Commercial Purpose, and that such collaborator agrees in writing (a) not to transfer such materials to any third party, and (b) to use such transferred materials and/or information solely for research and not for Commercial Purposes. Commercial Purposes means any activity by a party for consideration and may include, but is not limited to: (1) use of the product or its components in manufacturing; (2) use of the product or its components to provide a service, information, or data; (3) use of the product or its components for therapeutic, diagnostic or prophylactic purposes; or (4) resale of the product or its components, whether or not such product or its components are resold for use in research. Invitrogen Corporation will not assert a claim against the buyer of infringement of the above patents based upon the manufacture, use or sale of a therapeutic, clinical diagnostic, vaccine or prophylactic product developed in research by the buyer in which this product or its components was employed, provided that neither this product nor any of its components was used in the manufacture of such product. If the purchaser is not willing to accept the limitations of this limited use statement, Invitrogen is willing to accept return of the product with a full refund. For information on purchasing a license to this product for purposes other than research, contact Licensing Department, Invitrogen Corporation, 1600 Faraday Avenue, Carlsbad, California 92008. Phone (760) 603-7200. Fax (760) 602-6500. Limited Use Label License No. 178: Lifetime-resolved assay procedures This product is sold under license to U.S. Patent 4,822,733 from Vysis, an Abbott Laboratories company. This product is licensed for research use only and may not be used for in vitro diagnostics. This product and/or the use of this product is covered under one or more of the following US patents: 5,622,821, 5,639,615, 5,656,433, and 4,822,733, as well as pending patent applications owned by or licensed by Invitrogen Corporation. LanthaScreen is a trademark of Invitrogen Corporation. Ultra Evolution and Safire 2 are trademarks of Tecan Group Ltd. Analyst is a registered trademark of Molecular Devices Corporation EnVision is a trademark of PerkinElmer Life and Analytical Sciences 2004-2005 Invitrogen Corporation. All rights reserved. For research use only. Not intended for any animal or human therapeutic or diagnostic use.