FRET Sensitized Emission

Similar documents
D e c N o. 2 8

Sep No.20 CONFOCAL APPLICATION LETTER. resolution. Emission. Wavelength LAS AF APPLICATION WIZARD FRET SENSITIZED EMISSION

Setup for LanthaScreen Terbium Assays on SpectraMax Paradigm Microplate Detection Platform with SoftMax Pro 6 software

How to use the SP5 confocal microscope

Special Techniques 1. Mark Scott FILM Facility

LanthaScreen Europium Assay Setup Guide on the BMG LABTECH CLARIOstar Microplate Readers

Setup for LanthaScreen Terbium Assays on SpectraMax M5/M5e Microplate Reader with SoftMax Pro 6 Software

Instruction Manual. Catalog # For use with Bio-Plex Manager Software Version 4.0 and MCV plate III

Confocal Microscopy Analyzes Cells

VIOLATION BATCH ACTIONS

Specifications of the Thermo Scientific CellInsight Personal Image Cytometer

Adapta Assay Setup Guide on the BioTek Instruments Synergy 2 Multi-Mode Microplate Reader

ARM-D Kits Data Acquisition and Analysis Guide. Real-Time PCR Platform: Applied Biosystems QuantStudio 7 Flex Real-Time PCR System

DATA LOGGER Model DL-SA11

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

Determining presence/absence threshold for your dataset

Multiplexed 3D FRET imaging in deep tissue of live embryos Ming Zhao, Xiaoyang Wan, Yu Li, Weibin Zhou and Leilei Peng

EDUCATION EXPERIMENT. Fluorescence of an Unknown Fluorophore. Introduction.

ENVI Tutorial: Using SMACC to Extract Endmembers

Application Note. Quench Correction for LANCE Time-Resolved Fluorescence Resonance Energy Transfer LANCE.

Theremino DNA Meter. Fluorometer for DNA Measurements. Ana Rodriguez (MUSE) - Lodovico Lappetito (Theremino)

Bio-Well GloveManual

Widefield Microscopy Bleed-Through

iq 5 Calibration: Contents.

Utility of Variable Bandwidth Monochromators for Quantification of Fluorescent Probes in Produced Effluent Water

Microscopy from Carl Zeiss

SUPPLEMENTARY INFORMATION

Omnia Assay Setup Guide on the Tecan Safire 2 Microplate Reader

SpectraMax Paradigm Microplate Reader

Applying Online with Conway Corp

NovoCyte Flow Cytometer

HID Real-Time PCR Analysis Software v1.3

Welcome! openmicberkeley.wordpress.com. Open Berkeley

Smaart v8.2 Quick Start

USER GUIDE FOR INTERNETBANKING SERVICE OF PPF banka a.s.

Bio-Well Sputnik Sensor Manual

Supplementary Figure 1. The normalized absorption and emission spectra of 605QD

Performance Analysis,Modeling & Capacity Planning with IBM Content Capacity Planner Tool

Bio-Well Water Sensor Manual

LET S TALK (916)

After clicking the link in the Broker Portal or Producer World, you will be prompted to enter your NPN #, then click Continue.

Department of Chemistry, Center for Photochemical Sciences, Bowling Green State University,

Fuel Fluorescence Logging using the Optical Image Profiler (OIP)

USER GUIDE FOR INTERNETBANKING OF PPF banka a.s.

1. Access Taleo by using the Search feature on your my.boisestate.edu page or via the Human Resources website Quick Links.

Real-Time PCR Principles and Applications

Welcome to the course on the working process with the Bank Statement Processing.

A photoprotection strategy for microsecond-resolution single-molecule fluorescence spectroscopy

Nodes of regulation in cellular systems

PureSense. Irrigation Manager. User Guide

Requisition Approver Quick Reference

ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT

Lead Scoring CRM Integration

SoftMax Pro 5 Software

Confocal Microscopy & Imaging Technology. Yan Wu

PALM/STORM, BALM, STED

Omnia Assay Setup Guide on the Thermo Scientific Varioskan Flash Multimode Reader

DOE Wizard Multilevel Factorial Designs

ARM-D Kits Data Acquisition and Analysis Guide

Setting up a Run of Real-time PCR cycler Rotor Gene 3000

Test Your Plate Reader Set-up Before Using LanthaScreen Eu Assays

Getting Started With Free CompFacts

Quick Start Guide. Support Support phone:

LightCycler 480 Instrument Quick Guide

imark Mobile Ordering System

FRET measurement between YFP and CFP

Bricks'n'Tiles. Easy Creation of Architectural Textures Tutorial Creating a seamless brick texture

static MM_Index snap(mm_index corect, MM_Index ligct, int imatch0, int *moleatoms, i

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode

Payroll and Demographics User Guide

The ingenious Fusion Optics in the Spark multimode reader

CALIBRATION AND INSTRUMENT TESTING INDUSTRIS WORKING STRUCTURE MODEL

Tutorial. Primer Design. Sample to Insight. November 27, 2015

204 Part 3.3 SUMMARY INTRODUCTION

Step-by-Step Instructions: Generating Time Summary Estimator and Time Card Approval Reports

Analog Arts High Performance Instruments Comprehensive Instruction Manual

High Resolution Melting Protocol

COBRA Employer Web Portal Tutorial

AquaFlash: Handheld Active Fluorometer. Pam Mayerfeld Vice President, Marketing & Sales April 6, 2017

CompeGPS Competition version 6 Manual. CompeGPS Competition version 6 Manual. CompeGPS Team S.L.

TRF. SpectraMax Paradigm Time Resolved Fluorescence (TRF) Detection Cartridge. User Guide

Evolution Payroll. User Guide (Basic Version) 2017 Payroll Solutions, Inc &

OXSAS. Product Specifications. X-Ray Fluorescence Analysis Software

Actual Count of Inventory

Productivity. PPS Cart: PulseNet Production Systems. Powerful Tools for Better Performance

General RF Scanner Instructions

FAST 1.0 USER TUTORIAL Copyright Phillip S. Pang, 2011

Appoint, Change and Terminate (ACT) Documentation Equity Increase

A quantitative protocol for intensity-based live cell FRET imaging.

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

SIWAREX WP231 Flexible weighing module for S and stand-alone operation. Calibrating SIWAREX WP231 with SIWATOOL V7

Compensation: Fundamental Principles

Creating a New Quote

Voucher Build Request

OXSAS Optical Emission Analysis Software

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

CASE STUDY. twenty. Stochastic Customer Forecasting. case study OVERVIEW. Application Overview and Model Development.

GUIDELINES AmpliSens Florocenosis / Aerobes-FRT AmpliSens

Exceed IRELAND Electronic Postage Computing Scale

Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents

Transcription:

Page 1 of 8 FRET Sensitized Emission Function The FRET Sensitized Emission wizard is used for measuring the FRET efficiency. For this purpose, the fluorescence emission of the acceptor that results from the radiation-free energy transfer of an excited donor molecule is measured. However, the accuracy of the measurements can be affected by optical crosstalk, excitation of the acceptor through the excitation wavelength of the donor or impact of the background on the signal. The use of this method under the guidance of the wizard allows for correcting these phenomena and thereby contribute to optimizing the image and the measurement of the FRET share. Three different types of cells (references) are required for the FRET experiment:! Cells containing only the donor dye.! Cells containing only the acceptor dye.! FRET cells containing donor as well as acceptor dyes and in which the FRET occurs. The first two samples provide the reference values that are required for correcting the optical crosstalk and the possible excitation of the acceptor through the wavelength of the donor. The third sample is the actual FRET sample on which the measurement is performed. The FRET Sensitized Emission wizard is divided into three steps:! In Step 1, the recording settings for donor, acceptor and FRET sample are defined or default values are loaded and adjusted.! In Step 2, three channel images are sequentially recorded "line by line" and the ROIs are plotted that are used for correcting the optical crosstalk and the background effect as reference: Channel A: Excitation with excitation wavelength of donor and detection with parameter settings of donor (donor channel) Channel B: Excitation with excitation wavelength of donor and detection with parameter settings of acceptor (FRET channel) Channel C: Excitation with excitation wavelength of acceptor and detection with parameter settings of acceptor (acceptor channel)! In Step 3, the FRET experiment and the analysis of the FRET efficiency are performed. In addition, several options are available to further optimize the resulting image and to save the measurement results. Procedure Step 1

Page 2 of 8 The complete experiment can be skipped if you are only interested in viewing the measurement results of saved data records. For this purpose, click the button: 1!Load the predefined settings for recording the donor and acceptor. Or:!Define the recording parameters for the donor and acceptor. + + : One channel and one excitation wavelength are used to record images of the donor and acceptor. 2!The integration rate of image recordings to improve signal/noise ratio. 3!If necessary, zoom in on and center a section of the specimen. 4 To determine the desired integration share for the image quality of donor and acceptor:!record an image of the donor (or acceptor and FRET sample)

Page 3 of 8 + for the Continuous Scan + for a single recording 5!If required, save the settings made for future FRET experiments. 6!Proceed to the next step. Step 2 1!Start the recording. The result will be three sequentially recorded channel images. Channel A: Excitation with excitation wavelength of donor and detection with parameter settings of donor (donor channel) Channel B: Excitation with excitation wavelength of donor and detection with parameter settings of acceptor (FRET channel) Channel C: Excitation with excitation wavelength of acceptor and detection with parameter settings of acceptor (acceptor channel) In this case, the Continuous button is used only for image optimization. The recorded images feature a digital resolution of 12 bit. For this reason, the dynamic range covers 4,096 different intensity values. However, the amount of data to be saved increases. a) Donor only!in the View window, change to the donor channel.

Page 4 of 8 1 2!In the Donor only field, click on the Signal button.!plot an ROI in the image where only donor dye (signal) is found. The capital letters A, B and C represent the three channels. the overall mean value of all ROIs in the respective channels. These are reference values that are used for the subsequent calibration and measurement. To accept the values for your measurements, click on the Apply button. 3!In the Donor only field, click on the Background button.!plot an ROI in the image where no signal is found (background). The capital letters A, B and C represent the three channels. the overall mean value of all ROIs in the respective channels. These numbers can be used to determine the amount of background effect in the different

Page 5 of 8 channels. These are reference values that are used for the subsequent calibration and measurement. To accept the values for your measurements, click on the Apply button. b) Acceptor only 1!In the View window, change to the acceptor channel. 2!In the Acceptor only field, click on the Signal button.!plot an ROI in the image where only acceptor dye is found. The capital letters A, B and C represent the three channels. the overall mean value of all ROIs in the respective channels. These are reference values that are used for the subsequent calibration and measurement. To accept the values for your measurements, click on the Apply button. 3!In the Acceptor only field, click on the Background button.!plot an ROI in the image where no signal is found (background).

Page 6 of 8 The capital letters A, B and C represent the three channels. the overall mean value of all ROIs in the respective channels. These numbers can be used to determine the amount of background effect in the different channels. These are reference values that are used for the subsequent calibration and measurement. To accept the values for your measurements, click on the Apply button. c) FRET Sample 1!In the View window, change to the FRET channel. 2!In the FRET Sample field, click on the Background button. the overall mean value of all ROIs in the respective channels. These numbers can be used to determine the amount of background effect in the different channels. These values are used for the FRET efficiency measurement. To accept the values for your measurements, click on the Apply button. 3!Proceed to the next step. Step 3 1!Adjust the necessary time parameters for live specimen: & see Recording time image series If no settings are performed, the default value is 1 frame.

Page 7 of 8 2!Start the FRET experiment. 3 The values in the Calibration Coefficients field represent the constants that the software calculated from the calibration measurement in Step 2. They describe the crosstalk between the channels. a = share of acceptor signal in the donor channel (channel A). Correction factor from the acceptor sample = donor emission (donor excitation) / acceptor emission (acceptor excitation) a = share of donor signal in the FRET channel (channel B). Correction factor from the donor sample = acceptor emission (donor excitation) / donor emission (donor excitation) c = share of acceptor signal in the FRET channel (channel B). Correction factor from the acceptor sample = acceptor emission (donor excitation) / acceptor emission (acceptor excitation) If you activate the Manual Correction check box, you can manually correct the values calculated by the software. 4 Finally, the FRET effectiveness is automatically calculated by the Leica Confocal software for the complete frame or the plotted ROIs. The calculated values are displayed in the Calibrated Results field. To learn about the meaning of the different formula components, click on the question mark in the corner ( ). Several options are also available in this step to further optimize the resulting image and to save the measurement results. This function creates an analysis graph that represents the time-based behavior of the median intensity during the data recording. You can save the complete FRET experiment in xml format. The file contains the image recording of donor, acceptor and FRET, the number of recorded frames and their analysis data, the measurement parameters and the hardware parameters defined for the experiment. Visualization factors The display of the FRET signal and the FRET effectiveness can be intensified

Page 8 of 8 here. Thresholds A threshold can be defined for each channel to perform a noise correction. Filter If the Filter source (Blur) check box is selected, a blur filter is applied. This filter type filters the high frequencies out of the image. That is, the distinctive transitions from low to high intensity values are reduced. This filter can be used to remove noise from an image. Apply-keys The Apply buttons are used to accept the optimized images in the experiment.