[ VION IMS QTOF ] BEYOND RESOLUTION

Similar documents
PESTICIDE SCREENING APPLICATION SOLUTION

[ MS IMAGING ] FULL SPECTRUM MOLECULAR IMAGING COMPLETE VISUALIZATION OF MOLECULAR DISTRIBUTIONS

MAXIMIZE YOUR LABORATORY RESOURCES FOR INCREASED PRODUCTIVITY

BIOANALYTICAL STRATEGY FOR IN VITRO METABOLITE SCREENING WITH EXACT MASS USING THE Q-Tof micro. Jose M. Castro-Perez 1, Carina Leandersson 2

ENHANCED MS WITH THE TURN OF A KEY

ENSURING QUALITY THROUGH COMPLIANCE [ COMPLIANCE ]

[ PURIFICATION SOLUTIONS ] Pure at Heart

TechnicalNOTE METABOLYNX EXACT MASS DEFECT FILTER: RAPIDLY DISCRIMINATE BETWEEN TRUE METABOLITES AND FALSE POSITIVES INTRODUCTION

Microflow LC-MS with the turn of a key

[ ANALYTICAL SERVICES SOLUTIONS ] constant DEADLINES... FASTER THAN EVER BEFORE.

FRACTIONLYNX APPLICATION MANAGER

ANALYTICAL STANDARDS AND REAGENTS

Step up to the challenge with a step change. [ xevo TQ-S ]

of peptide mapping chemistries, 130Å or 300Å with tunable UV, photodiode array, or mass spectrometry

Overview. Tools for Protein Sample Preparation, 2-D Electrophoresis, and Imaging and Analysis

BIOANALYSIS CONSUMABLE SOLUTIONS. Sample Preparation and Liquid Chromatography Solutions for Quantitative BIOANALYSIS

[ EMPOWER 3 SOFTWARE ] MORE CAPABILITIES FOR YOUR LAB, MORE VALUE FOR YOUR ENTERPRISE

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

for water and beverage analysis

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION

Metabolite Identification Workflows: A Flexible Approach to Data Analysis and Reporting

ALLIANCE SYSTEM FOR CARBAMATE ANALYSIS

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

ApplicationNOTE THE USE OF A NANOLOCKSPRAY ELECTROSPRAY INTERFACE FOR EXACT MASS PROTEOMICS STUDIES

Faster, easier, flexible proteomics solutions

PrimePCR Pricing and Bulk Discounts

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

ProteoMiner Protein Enrichment Technology

PrimePCR Pricing and Bulk Discounts

PrimePCR Pricing and Bulk Discounts

From routine to research, always the right answers.

New Core-Shell Technology

Lawson Talent Management

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Discover the Importance of Third Party Quality Control

Siemens Partner Program

thermo scientific Find out more at thermofisher.com/lims TECHNICAL INFORMATION BULLETIN

Staples & OB10. Conference Presentation. Kevin Bourke & Joachim Eckerle Date: Presented by:

IMPROVING SALES EFFECTIVENESS. John Kieffer Business Transformation Director

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

Detailed Data from the 2010 OECD Survey on Public Procurement

Informatics and High Resolution QTof MS. How can we ask better questions and get better answers in DMPK? Mark D. Wrona

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

Optimize Your Process Operations by Improving Process Monitoring

Waters Pesticide Screening Solutions: Nuove Frontiere nell Analisi di pesticidi Miguel Ángel Cortés, Waters Manuela Cuccurullo, Waters

Impact of MRCT after ICH E17 fully implement -Industry perspective-

3 Italy Takes Its Innovation Strategy to a New Level with Collaborative Go-to-Market Plan for SMBs

The Benefits of SOLAμ Technology in Sample Preparation. Jon Bardsley and Ken Meadows Thermo Fisher Scientific, Runcorn, UK

Simplifying Complex Multi-Residue Pesticide Methodology in GC-MS/MS

RESISTING INERTIA: Auditing and Benchmarking Your Global Mobility Program. By Steve Nurney, Principal at Mercer

Employee Assistance Programmes Global coverage, local delivery

BioPlex 2200 Syphilis Total & RPR Assay

Chromatography Column Performance and Data Analysis Success Guide. Hints and Tips for Better Purifications

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Solution Partner Program Global Perspective

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Thermo Scientific Q Exactive HF Orbitrap LC-MS/MS System. Higher-Quality Data, Faster Than Ever. Speed Productivity Confidence

Thermo Scientific TSQ Quantiva Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative performance. with unprecedented ease

For Routine Applications

COMPENSATION REVIEW AND ANALYSIS SERVICES TAKING THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

PRODUCT INFORMATION PLR 3D LOCALIZATION OF PARTS IN CARRIERS. Robot guidance systems

QIAcube HT Your Purification Expert

SGS Delivering Excellence in Compliant Extractables and Leachables Testing

Agilent N6171A MATLAB Data Analysis Software for X-Series and PSA Series Signal and Spectrum Analyzers

Imaging and Electrophoresis. Gel Doc EZ Imager. Accelerate your research. Push-button imaging in just 10 seconds.

Process Maturity Profile

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

Streamlined and Complete LC-MS Workflow for MAM

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

[ Care and Use Manual ] Waters AccellPlus QMA and CM Bulk Media. I. calculating bulk media needs. II. packed column use. IIi.

safetyiq: THE NEW DIMENSIONS OF SAFETY DISCOVER INTELLIGENT PROTECTION FOR MORE PRODUCTIVITY Forward-thinking safety products, systems and services

Agilent solutions for contract research and manufacturing organizations

WORKFORCE METRICS BENCHMARK REPORT

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

hp hardware support onsite global next day response

Introduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications

Product Catalog # Description List Price (JPY) Primer Assays (desalted)

Bio-Rad Laboratories BIOPLEX 2200 SYSTEM. BioPlex 2200 ANA Screen with MDSS. The first and only fully-automated, multiplexed ANA Screen

MERCER EXECUTIVE REMUNERATION GUIDE THE KEY TO DESIGNING COMPETITIVE EXECUTIVE REMUNERATION IN THE MIDDLE EAST

[ MARKET SOLUTION ] Chromatography Data System Solutions for the Agrochemical Industry

[ product solution ] Waters Oasis µ Elution PlateS. Patented Innovation. Elution volume as low as 25 μl. No evaporation and reconstitution

Thermo Scientific EASY-Spray Technology. Plug-and-spray with. State-of-the-art performance

Microsoft Dynamics CRM Online. Pricing & Licensing. Frequently Asked Questions

International management system: ISO on environmental management

5 REASONS TEKTRONIX OSCILLOSCOPES ARE RELIABLE AND TRUSTED TECHNICAL BRIEF

GLOBAL VIDEO-ON- DEMAND (VOD)

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

IFS CLOUD ON MICROSOFT AZURE YOU RE ALWAYS READY TO POUNCE

WHITE PAPER 5 TIPS FOR MANAGING FOOD AND BEVERAGE SUPPLY CHAIN

Dimension Data Managed Cloud Services for Microsoft

SCIEX OS Software One Touch Productivity

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Developing a Global Workforce January 26, 2012

Simultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis

ApplicationNOTE Introduction

Bio-Plex Pro Mouse Cytokine, Chemokine, and Growth Factor Assays

MetaXpress High-Content Image Acquisition and Analysis Software

Agilent 6000 Series LC/MS Solutions. Confidence in Quantitative and Qualitative Analysis

Transcription:

[ VION IMS QTOF ] BEYOND RESOLUTION

THE BENEFITS ARE CLEAR and routinely available, Complex samples give complex data with overlapping spectra and background interferences, making compound identification difficult and method development costly and time consuming. Sometimes resolution and accurate mass are not enough to identify analytes, so additional experiments are needed, making even routine analysis slow and inefficient. Vion IMS QTof moves ion mobility mass spectrometry from research to routine. Rely on ion mobility to clean up and simplify every spectrum, so interpreting your data is easier than ever before. Find, identify and quantify your analytes confidently, enabling faster method development and higher sample throughput. Waters innovation and commitment to ion mobility brings you our most exciting benchtop platform: Vion IMS QTof, a high resolution benchtop QTof mass spectrometer that delivers the selectivity of ion mobility to every scientist, for every analysis. The ion mobility capability of Vion IMS QTof is powered by T-Wave technology, which means it has higher transmission than any other form of ion mobility. QuanTof2 technology delivers the dynamic range to make ion mobility quantitative and routinely usable.

[ VION IMS QTOF ] seamlessly from samples to answers. Just press start You ll have more time to focus on the things that matter to you. It couldn t be simpler; just press start and Vion IMS QTof is calibrated and ready for you to acquire data. Simply acquire Vion IMS QTof delivers high resolution, high sensitivity, sub 1 ppm mass accuracy, and enhanced quantitative performance without any compromises. Data acquisition methods use ion mobility as standard and are simple and straightforward to set up. Vion IMS QTof does the work you need it to do freeing up more of your time. Get to the answers UNIFI Scientific Information System automates processing, enables data visualisation, and produces reports, presenting the data so that you can quickly and easily get to the answers you need.

BEYOND resolution How much resolution do you need when sample variation and complexity cause common analytical challenges? Retention time shifts, isobaric analytes, and spectral interferences: only when ion mobility is a routine part of your analyses can you confidently overcome these challenges. Detect more compounds Ion mobility cleans up and simplifies your spectra, enabling identification of all the compounds in your sample. Discover analytes you didn t even know were there. Fully characterize your sample with confidence and make informed decisions. Confidently identify your compounds With CCS values available for every ion in every analysis, you have new levels of confidence in your identifications. Retention time is prone to vary with different chromatographic conditions and changing matrices. However, identifications based on CCS and m/z are precise and independent of retention time. Analyte identifications are right first time, every time. LC Run (min) Matrix Observed (m/z) Mass error (mda) Mass error (ppm) Observed RT (min) Observed CCS (Å 2 ) 3 Solvent 609.2808 0.2 0.32 1.17 248.38 10 Plasma 609.2807 0.1 0.15 3.18 248.15 30 Urine 609.2803-0.3-0.56 7.64 247.69 RMS ppm error = 0.38 %RSD Observed CCS = 0.14 The data presented above demonstrates that CCS values obtained for reserpine are precise and are matrix and retention time independent. A. B. Retention time aligned LC-MS E data obtained for a protonated desmethyl glucuronide metabolite detected in rat bile after the administration of verapamil. (A) shows the precursor ion spectrum and (B) shows the associated higher energy fragment ion spectrum. C. D. HDMS E adds clarity to your data. The addition of drift time alignment enables detection of (C) a single component precursor ion spectrum for the protonated desmethyl glucuronide metabolite detected in rat bile after the administration of verapamil and (D) the associated product ion spectrum. This level of clarity aids data interpretation and cannot be achieved with mass resolution alone.

[ VION IMS QTOF ] HDMS E : unlimit ed p roduct ion acquisition Have confidence in your data. HDMS E Unlimited Product Ion data independent acquisition combines the information content of high resolution MS/MS with the selectivity of ion mobility separation. Ion mobility separation not only allows chromatographically coeluting compounds, but also structural isomers, to be resolved. This enables single component precursor/product ion spectra to be generated as ion mobility allows drift and retention time alignment of product ions and their respective precursors. This provides unparalleled specificity for a data independent acquisition. Two analytes at the same retention time, but at different drift times, result in product ion spectra that are fully separated from one another, enabling easier, automated data interpretation. The data collected are comprehensive with retention time and drift time aligned precursor and product ion spectra for all ions. If you need to know more, simply re-interrogate your data. High resolution IMS enabled LC-HDMS spectrum yields two peptide ID s that differ only by observed CCS High resolution LC-MS spectrum yields one peptide ID More resolution does not always give you more information. The data here illustrates that only with ion mobility can you see all the components in your sample.

UNIFI taking data to know ledge UNIFI Scientific Information System drives Vion IMS QTof to deliver the most comprehensive analytical workflows. Target, identify, quantify, review, and report using streamlined analytical workflows that enable more confident results across a wide range of applications. Make better decisions faster when CCS values are incorporated into your workflow, to reduce both false positives and false negatives, increase throughput, and boost laboratory productivity. Simplify your workflow. The latest version of UNIFI incorporates all the tools you need to confidently identify all drug metabolites. CCS values are available for every metabolite since IMS /CCS data reduction is embedded in UNIFI processing. Take advantage of the IMS dimension when HDMS E is your routine acquisition method. BE ASSURED. CHOOSE WATERS GLOBAL SERVICES. Waters Global Services focuses on optimizing Waters products with superior service, support, upgrades, training, and Waters Quality Parts. PROVEN SATISFACTION For 14 consecutive years, an independent quality auditing firm has ranked Waters Global Services as Best-in-Class in providing expert technical knowledge, quick resolution of system issues, and process support. 1 1. Achievement in Customer Excellence Award, Comfirmit/CustomerSat, Inc., 2007-2014; NorthFace ScoreBoard Awards șm Omega Management Group Corporation, 2001-2003.

[ VION IMS QTOF ] VION working for you Screening Screening and quantification are daily activities for many scientists across a wide range of scientific disciplines. Meeting legislative and regulatory demands requires the utmost confidence in your data. UNIFI informatics workflows integrate the value of CCS, reducing false positives and false negatives driving laboratory efficiency. Pharma The pharmaceutical industry is driven by the need to improve health and quality of life. The combination of UNIFI and Vion IMS QTof brings ion mobility to your drug discovery experiments while maintaining the ease and efficiency you need for your routine Met ID processes. Use CCS for confidence in component identification and structural characterization from cleaner product ion spectra. Omics Increasing requirements to improve understanding of biological processes are driving the rapidly evolving analytical approaches applied in life and health sciences omics research. A recurring challenge for these omics studies is the identification and structural elucidation of metabolites, lipids, and peptides of interest. Incorporating Vion IMS QTof into your workflow gives you not only CCS data for every component, but also increased analytical space and resolution. Using this additional information increases the identification confidence compared to traditional analytical approaches. False positive False negative Screening for known Pesticides with CCS in a small scale proficiency test. Using CCS values as an additional filter for molecular identification enables false positive and false negative identifications to be minimized, improving confidence and efficiency of the analysis. The additional specificity afforded by CCS measurements minimizes false negatives by allowing m/z and/or rt tolerances to be relaxed.

SALES OFFICES: Australia 61 2 9933 1777 Austria 43 1 877 18 07 Belgium and Luxembourg 32 2 726 1000 Brazil 55 11 4134 3788 Canada 1 800 252 4752 China 86 21 6156 2666 Czech Republic 420 2 617 11384 Denmark 45 46 59 8080 Finland 358 9 5659 6288 France 33 1 30 48 72 00 Germany 49 6196 400 600 Hong Kong 852 2964 1800 Hungary 36 1 350 5086 India 91 080 49292200 03 Ireland 353 1 448 1500 Israel 9723 3731391 Italy 39 02 265 0983 Japan 81 3 3471 7191 Korea 82 2 6300 9200 Malaysia 603 7841 1688 Mexico 52 55 52 00 1860 The Netherlands 31 76 508 7200 Norway 47 6 384 6050 Poland 48 22 101 5900 Portugal 351 21 893 61 77 Puerto Rico 1 787 747 8445 Singapore 65 6593 7100 Spain 34 93 600 9300 Sweden 46 8 555 115 00 Switzerland 41 56 676 7000 Taiwan 886 2 2508 5500 UAE 971 4 214 62 38 UK 44 208 238 6100 US 1 800 252 4752 www.waters.com/vion Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 508 478 2000 F: 508 872 1990 www.waters.com Waters, The Science of What s Possible, UNIFI, and Waters Quality Parts are registered trademarks of Waters Corporation. Vion, T-Wave and QuanTof2 are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2016 Waters Corporation. Printed/Produced in the U.S.A. October 2016 720005373EN TC-SIG