AREA SEPARATION WALL SYSTEMS

Similar documents
STRONGER THAN STEEL SṂ

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

2012 & 2015 International Building Code. Section Section Section Section Section Section 713.4

2012 & 2015 International Building Code. Section Section Section 713.4

LISTING INFORMATION OF ClarkDietrich Wall Assembly Design No. CD/WA SPEC ID: 26053

SHAFTWALL & AREA SEPARATION WALL SYSTEMS PRODUCT CATALOG

SECTION NON-STRUCTURAL METAL FRAMING

The GlasRoc Shaftliner Type X advantage...

SHAFTWALL AND AREA SEPARATION WALL SYSTEMS

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

ARCHITECT PRODUCT SPEC GUIDE

Area Separation Walls

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

SECTION COLD-FORMED METAL FRAMING

Code Compliance Research Report CCRR-0205

THE STEELFORM GOLD STANDARD. Product Data Sheet. Non-loadbearing Steel Studs (NLB)

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

SECTION NON-STRUCTURAL METAL FRAMING

SECTION COLD-FORMED METAL FRAMING

Full-Line Product Catalog from PHILLIPSmfg.com. Download a FREE

I-STUD Shaftwall System

138 H-STUD AREA SEPARATION WALL SYSTEM

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

SECTION SOUND ISOLATION

A. AISI Specifications for Design of Cold-Formed Steel Structural Members

Shaftwall and Area Separation Wall Systems.

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

ASTM STANDARDS FOR COLD-FORMED STEEL

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

Product Guide Specification

***************************************************************************************************************

LEGACY REPORT Reissued October 1, Legacy report on the BOCA National Building Code/1999

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

Product Guide Specification

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Product Guide Specification

GA APPLICATION OF GYPSUM SHEATHING

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

NON-LOAD BEARING STEEL FRAMING

NON-LOAD BEARING STEEL FRAMING

I-STUD Shaftwall System

A. Section Metal Decking. (05300 in MF95) B. Section Cold Formed Metal Framing. (05400 in MF95)

Product Guide Specification

research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP REVISION 2007

SECTION NON--STRUCTURAL METAL FRAMING

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

RSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP

Fire protection for townhouses that share a common wall. AreaSeparationWall Systems

Product Designation As specified in the AISI standard for cold formed steel framing General provisions A5.2.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

For Best Non-Structural Steel Stud Specifications, Stay Apprised of Industry Standard Requirements

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Area Separation Walls

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION CEMENTITIOUS SHEATHING

Building Reputations Together. DensGlass. Shaftliner for Area Separation Walls

SECTION CEMENTITIOUS WOOD FIBER DECKS

SECTION COLD-FORMED METAL FRAMING

SSL-175. Specifications

SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

BEARING METAL STUD FRAMING

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

Union County Vocational - Technical Schools Scotch Plains, New Jersey

WALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems

SECTION COLD-FORMED METAL TRUSSES

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

CEMCO is Proud to Introduce an Innovative Steel Floor Joist System

When demanding consistent quality, specify FIRM-FILL SCM-250 to assist in achieving highly improved IIC sound performance in multifamily

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

SECTION GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION WALL AND DOOR PROTECTION

ThermaSteel Corporation ASSEMBLY MANUAL

FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system.

ENVIROBEAM SECTION ENVIRO-ROOF CURBS

Report No Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Make Waves. Topo 3-Dimensional System

1350 E. Lexington Ave. Pomona, CA 91766

Stark Truss Company, Inc. Revised December 14, 2018

Image courtesy of KTGY, Inc. ENGINEERED FOR FIRE CODE COMPLIANCE AND DESIGN FLEXIBILITY

SECTION GYPSUM BOARD

Image courtesy of KTGY, Inc. ENGINEERED FOR FIRE CODE COMPLIANCE AND DESIGN FLEXIBILITY

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

UL Design System HW-D-1012 continued

USG LEVELROCK BRAND SOUND REDUCTION BOARD SRB

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

8"'0.., ~f' ~'" NOTICE OF ACCEPTANCE (NOA) Petersen Aluminum Corporation 1005 Tonne Road Elk Village, Illinois 60007

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

RedHeader PRO product catalog STRONGER THAN STEEL. INTERIOR AND EXTERIOR FRAMING

Transcription:

13 AREA SEPARATION WALL SYSTEMS Fire-resistance protects lives and property. Area separation walls are non-load bearing, 2-hour and 3-hour rated vertical wall assemblies that provide fire-resistant protection between adjacent living units in apartment buildings, condominiums and townhouses. They are also referred to as party walls, firewalls, multi-family walls and H-stud assemblies. Assembled between two independent walls, area separation walls form a commonly shared party wall that extends from the foundation through the roofline. The walls are assembled with two 1" thick gypsum panel liners vertically installed between 2" H-studs spaced 24" o.c. At the top and bottom of the walls, C-runners are installed back-to-back between vertically stacked panels. Overall stacked area separation wall assemblies cannot exceed 50 feet or the limits of the applicable UL Fire Assembly. A photo of an area separation wall system after a fire is shown below. Although this was a tragic event, it clearly proves the effectiveness of the system. It performed as designed by maintaining the integrity of the firewall, protecting the lives and property of the adjacent units. Photo courtesy National Gypsum.

14 H-STUD ClarkDietrich H-studs are nominal 2" wide vertical members used to secure two 1" thick pieces of gypsum shaftliner in area separation wall assemblies. H-studs are inserted into C-runners and slid over gypsum panel liner edges, repeating until the desired wall length is achieved. Once the wall is plumbed, it is secured with aluminum burn clips. Product code Gauge Thickness Mils Design thickness Width HSN 25 18 0.0188 2-1/8 Size Length (ft) 8 10 12 C-RUNNER ClarkDietrich C-runner (or H-track) is used to secure H-stud and gypsum shaftliner panels in area separation wall assemblies. Attached to the foundation with power-actuated fasteners, C-runner is also used as top track to cap the H-stud and 1" gypsum shaftliner panels, with a second track screwed back-to-back to the lower runner, to hold the next level of assembly. Product code Gauge Thickness Mils Design thickness Width HRN1 25 18 0.0188 2-1/8 Size Length (ft) 8 10 ALUMINUM BURN CLIP ClarkDietrich aluminum burn clips are used as part of the H-stud area separation wall assembly and are designed to melt when exposed to fire. The clips hold the area separation wall assemblies in place at the floor, roof and truss line between adjacent units. In a fire, the aluminum burn clips on the fire-ridden side of the wall will melt, allowing the wall structure for that side to collapse. Product code Thickness Size Packaging Pcs./Bucket AB 0.050 2 x 2 x 2-1/2 500 AB63 0.063 2 x 2 x 2-1/2 AB40* 0.063 2 x 2 x 4 250 *For use with 3-hour Design Assembly based on GA File No. ASW 2600 other custom breakaway clip lengths available. Note: Check listed fire assembly for details of construction, thickness and length of required burn clips. Pub. No. CD-SHAFTWALL 10/17 The technical content of this literature is effective 10/10/17 and supersedes all previous information.

15 INSTALLATION PROCEDURES 1. Install C-runner along the floor in the desired position. 2. An additional track is installed vertically at the end of the wall. 3. Two 1" thick shaftliner panels are then inserted into the bottom and side tracks. 4. An H-stud is inserted into the lower track and slid over the edges of the shaftliner. 5. Repeat steps 3 and 4 until the desired wall length is achieved. 6. Cap the end and top of the wall with C-runner. 7. Confirm that the wall is plumb and then secure the assembly to the adjacent wall using aluminum burn clips on both sides of the wall. Make sure to leave a 3/4" gap between the area separation wall and adjacent wall. Clip spacing is dependent on the height of the wall. Wall assemblies can be stacked to a maximum height of 50' or per the details of the applicable UL assembly. NOTE: Check listed Fire Assembly for details of construction, thickness and length of required burn clips. Conforms to the follwing UL Assemblies: UL U336 UL U347 UL U366 UL U375

16 ALUMINUM BURN CLIP Clips melt away under intense heat. ClarkDietrich aluminum burn clips are used as part of the H-stud area-separation wall assembly and are designed to melt and break away when exposed to fire. The clips are used to hold the area-separation wall assembly in place at the floor, roof, and truss line between adjacent units. Should a fire break out in one unit, the Aluminum Burn Clips on the fire-ridden side of the area-separation wall will melt, allowing the wall structure for that side to collapse. The burn clips on the non-fire side will remain intact and hold the area-separation wall in place as a barrier to contain the fire within the unit of origin. Note: Check listed fire assembly for details of construction, thickness and length of required burn clips. INSTALLATION PROCEDURES 1. Attach an aluminum burn clip to the completed area-separation wall assembly. 2. One clip should be located at each H-stud on both sides of the wall. 3. Attach the aluminum burn clip to the H-stud with a screw. 4. Attach to the adjacent framing with a screw or a nail, as applicable. Pub. No. CD-SHAFTWALL 10/17 The technical content of this literature is effective 10/10/17 and supersedes all previous information.

17 CODE APPROVALS AND PERFORMANCE STANDARDS ClarkDietrich products meet or exceed these applicable performance standards. AISI "North American Specification for the Design of Cold-Formed Steel Structural Members", 2012 edition ASTM American Society for Testing and Materials A653 "Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process" A1003 C645 C754 C1002 E119 E72 E90 "Standard Specification for Steel Sheet, Carbon, Metallic- and Nonmetallic-Coated for Cold-Formed Framing Members" "Standard Specification for Nonstructural Steel Framing Members" "Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products" "Standard Specification for Steel Self Piercing Tapping Screw for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs" "Standard Test Methods for Fire Tests of Building Construction and Materials" "Standard Test Methods of Conducting Strength Tests of Panels for Building Construction" "Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements" UL Underwriters Laboratories testing standard UL 263 "Fire Tests of Building Construction and Materials" Multiple UL design listings Additional code approvals PEI AER-12061 (Shaftwall) Independent product testing and certification Sound ratings: (RAL) ClarkDietrich Building Systems is a proud member of the Steel Framing Industry Association (SFIA). LEED Services BUILD GREEN with ClarkDietrich Building Systems ClarkDietrich Building Systems is an active member of the U.S. Green Building Council and is committed to supplying quality products that are environmentally responsible. We are continually working to develop greener building products and sustainable business practices. ClarkDietrich steel framing helps contribute points toward LEED certification. For more details contact Technical Services at 888-437-3244 or visit www./leed. ClarkDietrich Building Systems has prepared this literature with the utmost diligence and care for accuracy and conformance to standards. ClarkDietrich intends this information to be accurate, informative, and helpful as a selection guide for choosing ClarkDietrich Building System products. However, this information is only to be used for guidance and is not intended to replace the design, drawings, specifications, and decisions of a professional architect or engineer. ClarkDietrich Building Systems or its affiliates shall not be responsible for incidental or consequential damages, directly or indirectly sustained, nor for loss caused by application of our products for other than their intended uses. Our liability is limited to replacement of defective products. Claims shall be deemed waived unless they are made to us in writing within thirty (30) days of the date a problem was or reasonably should have been discovered. ClarkDietrich Building Systems reserves the right to modify or change any information contained in this literature without notification. Scan for the most up-to-date ClarkDietrich literature. USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. LOCATIONS ClarkDietrich Building Systems Manufacturing and Sales Locations: ClarkDietrich Engineering Services. A full spectrum of solutions. CALIFORNIA Riverside GEORGIA McDonough P 678.304.5500 F 678.304.5555 CALIFORNIA Sacramento HAWAII Kapolei CONNECTICUT Bristol P 866.921.0023 F 860.584.6899 ILLINOIS Rochelle P 800.659.0745 F 513.645.0750 FLORIDA Dade City P 352.518.4400 F 352.518.4450 MARYLAND Baltimore P 410.477.4000 F 410.477.1550 Toll-Free Phone: 877.832.3206 Toll-Free Fax: 877.832.3208 Technical Services: 888.437.3244 Email: engineering@ CENTRAL Crown Point, IN NORTHEAST Bristol, CT SOUTHEAST McDonough, GA WEST Carlsbad, CA OHIO Vienna P 330.372.4014 F 330.372.1945 OHIO Warren-East P 330.372.5564 F 330.372.4055 TEXAS Baytown P 281.383.1617 F 281.573.1679 TEXAS Dallas P 214.350.1716 F 214.350.7252 CLIP EXPRESS SM P 866.638.1908 F 330.372.4055 VINYL CORP. P 800.648.4695 F 305.477.4108 STRAIT-FLEX P 888.747.0220