Chloramphenicol in Malaysia Waste Water and Its Residues in Animal Husbandaries Products

Similar documents
ApplicationNOTE Introduction

Application Note. Abstract. Authors. Food Safety

Application Note. Abstract. Authors. Introduction. Environmental

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

LC/MS/MS Determination of PFOS and PFOA in Water and Soil Matrices

A RAPID METHOD FOR THE DETERMINATION OF CHLORAMPHENICOL RESIDUES IN BLACK TIGER SHRIMP

Supporting Information

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2

Analysis of Trace Organic Contaminants in Water by Direct Injection Using Agilent 6490 LC/MS/MS with Pos/Neg Switching

Evaluation by Competent Authorities

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Quantitation of cyanotoxins in drinking water according to EPA 544 guidelines

EFFECTIVE SPE STRATEGIES FOR LC/MS DETERMINATION OF SUDAN DYES IN CHILI PRODUCTS

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

Application Note. Abstract. Authors. Environmental

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

A Generic Approach to the Extraction of Multi-functional Drugs using Mixed-mode SPE with LC-MS/MS Analysis

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

Additional guidance on: TNsG on Data Requirements, Part A, Chapter 2, Point 4. Analytical Methods for Detection and Identification.

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Automation for Improving the Workflows for LC-MS/MS. Francois Espourteille, Ph.D. Manager, Applications

Application Note. Abstract. Introduction. Experimental Instrument Conditions. Evaluation of Prohibited Dyes in Food : By An Automated Extraction

Extraction of Vitamin B7 (Biotin) from Serum Using EVOLUTE

Analysis of the Massachusetts Cannabis Pesticides List Using the SCIEX QTRAP System

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

EPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS

Chemicals Branch United Nations Environment Programme (UNEP) Division of Technology, Industry and Economics. Geneva

Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System

Illicit Drug Analysis in Urine Using 2D LC-MS/MS for Forensic Toxicology

ApplicationNOTE. Introduction. Liquid Chromatography. Method. Sample preparation

Determination of Chloramphenicol and Thiamphenicol Residues in Fish, Shrimp and Milk by ESI-LCMSMS

A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

Tender Specifications for High Sensitive Triple Quadrupole LCMSMS System

Method of determination of phthalates by gas chromatography / mass spectrometry in wines

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Nonylphenols and Ethoxylates in Water by LC/MS/MS

Strategies for Phospholipid Removal using Polymer-based SPE

The Agilent Metabolomics Dynamic MRM Database and Method

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

Validated Multi-Residue Method for Extraction and Analysis of Trace-Level Pesticides in Surface Water Application

VICH Topic GL49. at step 4 GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS USED IN RESIDUE DEPLETION STUDIES

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Rapid Extraction of Therapeutic Oligonucleotides from Primary Tissues for LC/ MS Analysis Using Clarity OTX, an Oligonucleotide Extraction Cartridge

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Certified Reference Material - Certificate of Analysis

Determination of Table 3 Compounds by LC/MS/MS Chemours Fluoroproducts Analytical Method Revision date: 4/26/2018

for water and beverage analysis

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

Multi-Residue Pesticide Analysis in Ginseng Powder: Optimized Cleanup After QuEChERS Extraction for UPLC-MS/MS And GC-MS/MS Analysis

Converting a Liquid-Liquid Extraction Method for Vitamin D to a 96-Well Plate Supported Liquid Extraction Format

Certified Reference Material - Certificate of Analysis

Revision of 30 April 2013 draft, 4 November 2013

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

UPLC with On-line-SPE Technology for the Analysis of Pesticides and Pharmaceuticals in Drinking Water

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

[ APPLICATION NOTE ] Determination of Acidic Herbicides in Water Using Liquid Chromatography-Tandem Quadrupole Mass Spectrometry APPLICATION BENEFITS

Enhanced biodegradation of carbamazepine after UV/H 2 O 2 advanced. oxidation

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

Automation for Improving the Workflows for LC-MS/MS

EVALUATION OF D DIFFERENT EXTRACTION METHODS OF PESTICIDE RESIDUES IN SPICES BY

Development and evaluation of Nano-ESI coupled to a triple quadrupole mass spectrometer for quantitative proteomics research

A Rapid imethod TM Test for Analysis of Four Immunosuppressants

Validation Data for the Analysis of Chlorotalonil in Leek Using Mini-Luke Method Followed by GC-QqQ-MS/MS

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Q40. This automated platform will streamline the two part QuEChERS method from the liquid extraction through the cleanup.

Quantitative analysis of illegal dyes in eggs using LC/MS/MS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Certified Reference Material - Certificate of Analysis

DETERMINATION OF MYCOTOXINE DEOXYNIVALENOL IN WHEAT FLOUR AND WHEAT BRAN

DETERMINATION OF ENDECTOCIDES IN ANIMAL TISSUES, MILK AND EGGS BY LC WITH FLUORESCENCE DETECTION

SCREENING OF HONEY FOR RESIDUES OF ANTIBIOTICS BY AN OPTICAL BIOSENSOR

Key Words Pesticides analysis, food safety, TSQ Endura, TraceFinder, MRL, tsrm, residue analysis

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Ultrapure water: LC-MS suitability tests

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

Improving the Detection Limits for Highly Basic Neuropeptides Using CESI-MS

Impurity Control in the European Pharmacopoeia

Increasing Throughput and Efficiency with Exactive LC/MS and Triple Quadrupole LC/MS/MS

Certified Reference Material - Certificate of Analysis

Validation Report 19

ANALYSIS OF MYCOTOXINS IN FOOD MATRICES

CLSI C60: Assay Validation & Post-Validation Monitoring

METHOD FOR SIMULTANEOUS DETERMINATION OF FOLPET AND CYMOXANIL ACTIVE INGREDIENTS (COMBINATION PRODUCTS) IN AQUEOUS MEDIA

Certified Reference Material - Certificate of Analysis

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Agreed by VICH Steering Committee January Adoption by CVMP 12 February Date for coming into effect January 2016

Multiresidue Screening of Agricultural Chemicals in a Food Matrix using Varian SPE and Triple Quadrupole LC-MS/MS

Agilent 6430 Triple Quadrupole LC/MS System

Ultra-Sensitive Quantification of Trastuzumab Emtansine in Mouse Plasma using Trap-Elute MicroLC MS Method

Transcription:

Chloramphenicol in Malaysia Waste Water and Its Residues in Animal Husbandaries Products Marni S. a, Malintan NT., Faridah I., Mustafa AM. b a Veterinary Public Health Laboratory, Department of Veterinary Services, Bandar Baru Salak Tinggi, Sepang, Selangor a Faculty of Medicine, University of Malaya, Kuala Lumpur ABSTRACT: A simple and rapid liquid chromatography-mass spectrometry with electrospray ionisation (LC- (ESI)-MS) confirmatory method for the analysis of chloramphenicol (CAP) in poultry tissues has been developed. The method was applied to investigate the occurrence of CAP in poultry samples. A total of 448 samples from 12 poultry processing plants were analysed, covering eight states in Malaysia. Waste water samples (influent and effluent) from animal husbandaries collected from rivers in the state of Perak, Malacca and Selangor were analysed for chloramphenicol. The detectable levels of chloramphenicol in the water were between 10 to 90 ng/litres. Samples were extracted by using liquid-liquid extraction steps with ethyl acetate. LC separation was achieved by a C-18 column and methanol-water as a mobile phase. The mass spectrometer was operated in multiple reactions monitoring mode (MRM) with negative electrospray interface. Three transition ions monitored were m/z 321 > 257, m/z 321 >152 and m/z 326>157 (IS). For quantification, m/z 321 >152 was chosen. Validation parameter includes specification, linearity, precision, accuracy, decision limit and detection capability. Samples were fortified at CAP levels of 0.1, 0.2 and 0.3 µgkg -1 with D 5 -CAP as internal standard. The limit of decision and detection capability was calculated at 0.032 and 0.054 µgkg -1 respectively. Keywords: chloramphenicol, antibiotic, chicken, poultry, health Introduction Chloramphenicol is a highly effective antibiotic, used widely to treat food-producing animals. However, chloramphenicol were banned in the European Union (European Commission 1994) because of evidence that it may cause serious adverse health effects in humans (World Health Organization 1988). In veterinary practices, runoff and leaching from feedlots or from the facilities themselves could carry these substances into the aquatic environment. Transformed and unmetabolised antibiotics are released into the aquatic system through manure or urine in waste water. In the environment, their conjugates are easily cleaved, thus they are released almost unchanged. Furthermore, as reported by Ternes; 1998 (1), Daughton and Ternes; 1999 (2) and Zwiener et al; 2000, (3) pharmaceuticals are not completely eliminated during waste water treatment and also not biodegraded in the environment. Thus, antibiotics for veterinary use or as growth promoters are excreted by the animals and end up in the waste. Corresponding Author: Marni S. Veterinary Public Health Laboratory Department of Veterinary Services Bandar Baru Salak Tinggi, Sepang, Selangor Published 12 January 2010 In Malaysia, where integrated animal and fish/vegetable farming is a common practice, manure readily available low cost fertilizer of good quality. This practice of manure disposal on land or incorporation into soil allows antibiotics to seep through the land system hence reaching the water source. Materials and Method Reagents and chemicals Chloramphenicol (CAP) was supplied by Sigma- Aldrich, USA. Deuterated chloramphenicol (D 5 - CAP), 99.6% isotopic purity was purchased from Cambridge Isotope Laboratories (Andover, MA, USA). All chemical and chromatographic reagents used were of either HPLC or analytical grade. Ultrapure water was filtered through a Millipore Rios system followed by a Milli-Q Biocell system (18.2 M cm -1 resistivity) (Millipore, Bedford, MA, USA). Nitrogen (99.999%) as desolvation and nebuliser gas was generated through a nitrogen generator from Whatman (Haverhill, MA, USA). Argon (99.999%) (MS MS collision gas) was obtained from Malaysian Oxygen (MOX). Sample collection and preparation for water sample A total of 50 waste water samples were collected from three selected swine production facilities from 41

Malacca, Selangor and Perak, respectively. The samples were collected in pre-cleaned 1 L polypropylene bottles. The waste water was collected at the influent and effluent points of each farm. The waste water samples were filtered using cotton wool to remove the suspended particles and then filtered with the 0.2 µm membrane filter (Whatman, UK). The samples were stored at 4 ºC until analysis. Extraction and cleanup for chicken tissue An amount of 2.0 ± 0.02 g of finely minced tissue was weighed into a 50 ml Falcon polypropylene tube. The sample was fortified with 200 l of 20 ng/ml internal standard D 5 -CAP (equivalent to 2 µg kg -1 ). The sample was mixed with 800 l HPLC grade water and homogenized for 15 s. CAP was extracted with 6 ml ethyl acetate by firstly mixing with endover-end rotator for 10 min followed by centrifugation at 3000 rpm for 5 min (+4 o C). After centrifugation, approximately 5 ml of the ethyl acetate layer from the upper phase was transferred to a clean test tube. The sample was evaporated to dryness under stream of nitrogen on a sample concentrator at 45-50 o C. The residue was reconstituted in 0.5 ml iso-octane and mixed by vortexing for 25 s. 0.5 ml of water was added and was mixed gently by shaking. The sample was centrifuged at 3000 rpm for 5 min (+4 o C). Approximate 0.2 ml of the aqueous phase (lower layer) was transferred into clean glass tube using a pasteur pipette or micropipette. The lipid layer that was located on top of the solution was avoided to ensure getting a clean sample. The aqueous phase was filtered through a 0.22 µm nylon filter directly into a HPLC vial. Instrumentation The LC system consisted of a 2695 Alliance Separations Module (Waters, Manchester, UK). Separations of the compounds were performed using HPLC Column: Luna C 18 (150 mm 2 mm; 3 m particle diameter) from Phenomenex, Torrance, CA. The LC separation of the CAP was achieved using a gradient elution mixture of water and methanol. The ESI-MS/MS detection of the CAP was carried out with a Quattro Ultima Pt triple-quadrupole mass spectrometer from Micromass Co. Inc. (Manchester, UK). The MS detector was operated with an electrospray ionisation (ESI) interface in the negative ion mode. The following tune parameters were used: capillary, 3.50 kv; cone, 35 Volts; source temperature, 120 o C; desolvation temperature, 350 o C; cone gas flow, 63 L h -1 ; desolvation gas flow, 595 L h -1 ; resolution (LM1, HM1) 13.0; resolution (LM2, HM2), 14.0; ion energy 1, 0.5; ion energy 2, 1.0; entrance, -1; exit, 0; photomultiplier, 650V; collision gas: argon (Pirani pressure, 2.52 10-3 mbar). Results and Discussion LC-MS/MS Analytes were detected by negative multiple reaction monitoring, after transition of the precursor ion into two product ions. MS-scan of CAP showed that the most abundant molecule for CAP is 321 and the most intense fragment ions from this molecular ion are 152 and 257 where 152 is the major fragment ion. The transitions monitored for D 5 -CAP was 325 > 157. Calibration, linearity and quantification CAP was quantified by an internal standard procedure based on matrix calibration curves. The calibration curves were constructed from five points spanning the concentration range from 0 to 0.5 µg kg -1. The calibration curve was based on the transition m/z 321 > 157 i.e. the daughter ion with higher intensity. The concentration of the deuterated internal standard was fixed at 2 g kg -1. The calibration curve obtained for the chromatographic peak areas ratio of CAP/IS versus known concentrations of CAP was found to be linear in the range of 0.1 to 0.5 µg kg 1. The correlation coefficients, R 2 for the curve was 0.9996. The mean slope was 1.0453 with a 3.58% variation coefficient and the mean intercept was 0.0247. Specificity The specificity of the method was evaluated from the 20 blank matrix samples. The samples were collected from different sources to prove if other substances can interfere with the retention time of CAP. HPLCchromatograms of blank and spiked sample of poultry muscle are shown in FIG. 1 and FIG. 2. The result shows that there was no interferences at the same retention time as chloramphenicol were found in all the blank matrix samples at all transition ion. This confirms the good specificity of the method. Precision and accuracy The precision of the method was tested by repeatedly analysing the spiked chicken samples. The accuracy and within-day precision of the method were determined in chicken muscle using seven determinations (n = 7) at three concentration levels: at 1/3 x MRPL, 2/3 MRPL and 1 MRPL. The withinday precision analysis was done on the same day. The between-day precision was determined by repeating the study for two consecutive days. The precision of the entire method was expressed by the 42

RSD of multiple analyses at different concentration level. The accuracy of the method was expressed as the mean recoveries of spiked analytes in chicken muscle at three concentration levels. TABLE 1 showed the recovery data that ranged from 94 % to 104%. The recovery values obtained in this study exceeded the acceptable Decision No. 2002/657/CE (4) for the analysis of residues at ppb-level indicating good accuracy of the method. Data in TABLE 2 showed a narrow spread of the RSD values of within-day and between-day precision. All R.S.D.s were below 7%. FIG.1- MRM chromatogram of blank chicken muscle FIG. 2- MRM chromatogram of chicken muscle spiked with 0.1 µgkg -1 CAP TABLE 1- Accuracy of the methodology expressed as recovery of spiked chicken samples Performance criteria Fortification level (µg kg -1 ) 0.1 0.2 0.3 Accuracy (%) Assay 1 100 99 97 Assay 2 104 103 99 Assay 3 101 99 94 Overall 102 100 97 TABLE 2- Method precision expressed as RSD of spiked chicken samples Performance criteria Fortification level (µg kg -1 ) 0.1 0.2 0.3 Precision CV (%) Assay 1 8.16 8.65 4.17 Assay 2 7.54 2.60 1.92 Assay 3 3.73 5.38 7.23 Intra-assay a 6.77 5.99 4.84 Inter-assay b 5.67 6.06 8.45 a Intra-assay precision of data analysed within the same day (n = 7) b Intermediate precision of data analysed on different day (n = 3) Limits of detection and limit of quantification The limit of detection (LOD) was defined as the concentration giving a signal to noise ratio of 3. The limit of quantification (LOQ) was considered as the concentration for which S/N was 10 (5). An estimate of LOD and LOQ was performed by extrapolating the S/N ratio of the peak areas obtained from a chicken meat sample fortified at 0.1 µgkg -1. The LOD and LOQ were estimated at 0.015 and 0.05 for m/z 321>257. 43

Application of the method The Veterninary Public Health Laborotary Salak Tinggi (VPHL), Department of Veterinary Services Malaysia, provided chicken tissue samples used in this study. The samples were collected by the veterinary meat inspectors from the Meat Inspection and Food Safety Unit. Chicken samples were collected as the government approved and certified poultry processing plant. All the plants operated for the commercial poultry production, where the production levels ranged from 2,000 to 90,000 birds per day. The sample source was from 12 processing plants located in Perak, Pulau Pinang, Kuala Lumpur, Selangor, Negeri Sembilan, Melaka, Terengganu and Sarawak. Samples were transported under cooled or frozen conditions to the laboratory and stored at temperature of -20 o C prior to analysis. Results of samples tested are shown in TABLE 3. From 448 samples analysed, 2 samples were detected to contain CAP at concentrations of 0.05 and 0.06 µg kg - 1. These concentrations exceeded LOQ value. The source of the positive samples was from Plant B. For the waste water analysis, fifty bottles of waste water samples (influent and effluent) were collected from each state of Perak, Malacca and Selangor then analysed. In this study, following HPLC analysis, LCMS was used to reconfirm the results. The results of HPLC analysis were summarised in TABLE 4. All the samples were then quantified using LCMS. Processing Plant ID TABLE 3- Results of CAP Detection in Chicken Samples Number of samples analysed Number of samples >LOD LOD <Number of samples <LOQ Number of samples LOQ A 52 0 0 0 B 104 0 0 2 (0.05 & 0.06 µgkg-1) C 130 0 0 0 D 32 0 0 0 E 12 0 0 0 F 7 0 0 0 G 62 0 0 0 H 8 0 0 0 I 7 0 0 0 J 7 0 0 0 K 5 0 0 0 L 22 0 0 0 TABLE 4- The detection frequency in the influent and effluent collected from the swine facilities in selected states in Malaysia. Forty-five were found to be positive from the total of 150 samples analysed. State Influent Effluent Concentration (ngl -1 ) Perak 1 0 10.02 Malacca 9 6 90.31 / 47.43 Selangor 2 1 12.75/10/58 a The concentrations displayed in the table were the highest concentrations detected in the samples. The levels detected in the influent precede the levels detected in the effluent. From the results, 12 influent samples and 7 effluent samples were found positive for CAP out of the total 150 waste water samples. The concentration ranged from 9.04 ng/l to 90.31 ng/l in the influent samples and 8.81 ng/l to 47.43 ng/l in the effluent samples. Based on the results, detection of CAP in the influent samples were higher than in the effluent samples (FIG. 3). The levels of CAP detected in each positive sample were summed to assist interpretation. This was expected as CAP would be in its most concentrated at the influent point as this is the entry point of the waste water from the farm into the waste lagoons. The distance between the influent and effluent points could have affect the concentration of CAP in the effluent samples. Thus, it could have been diluted over the distance and the concentration becomes lesser until it is too low to be detected. Furthermore, many environmental factors could have affected the antibiotic while it travelled from the entry (influent) to the exit (effluent) point such as rainfall, ph, temperature and organisms content. We are convinced at some point in the waste lagoons, CAP could be degraded or adsorbed into soil although this could not be proven unless point measurements at certain distance or analysis on the soil for CAP are done. Since chloramphenicol and also other antibiotics biodegradation varies according to temperature, ph, bacterial activity, chemical composition, water flow and/or distance between facility and sedimentation area, it is difficult to predict the bioaccumulation fate of antibiotics. This complicates the estimation of environmental exposure and also risk assessment. 44

Concentration (ng/l) Health and the Environment Journal, 2010, Vol. 1, No. 1 Chloramphenicol detected in the waste water samples 350 300 250 200 150 100 50 0 Perak Malacca Selangor Influent Effluent FIG. 3- Chloramphenicol detection in the waste water samples collected from the swine facilities in Perak, Malacca and Selangor Conclusion The method applied for determination of chloramphenicol in chicken is very simple and fulfils required sensitivity limit. It allows analysis of 20 30 samples per day. The performance of the method is in accordance with the requirements for the analysis of veterinary drug residues. Studies on waste water from animal husbandries showed that there is certain extent of contamination of these antibiotics in the Malaysian aquatic system. References 1. Ternes T. A. (1998). Occurrence of drugs in german sewage treatment plants and rivers. Water Research. 32: 3245-3260. 2. Daughton C. G., Ternes T. A. (1999). Pharmaceuticals and personal care products in the environment: agents of subtle change? Environ. Health Perspects. 107 (suppl. 6), 907-938. 3. Zwiener C., Glauner T., Frimmel F. H. (2000). Biodegradation of pharmaceutical residues investigated by SPE-GC/ITD-MS and on-line derivatisation. HRC-J. High Res. Chromatography. 23: 474-478. 4. Commision Decision of 12 august 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results, Off. J. Eur. Commun. 2002/657/EC, 2002. 5. Pozo O. J., Guerrero C., Sancho J. V., Ibanez M., Pitarch E., Hogendoorn E., Hernandez F. (2006) J Chromatogr A. 1103:83 93. 45