STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

RESIDENTIAL STAIRWAYS, HANDRAILS,

Visual Interpretation Of The

CITY OF OCEANSIDE. Single Family Dwelling Stairways/Guards. Informational Bulletin

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax:

Guidelines for planning the construction of a porch.

Width (2012 IRC SectionR ) Exception: The width of spiral stairways shall be in accordance with the section for spiral stairways.

DECK CONSTRUCTION REQUIREMENTS

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

Inspecting the Means of Egress Course

Village of Algonquin

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

CITY OF BRISTOL DECK CONSTRUCTION GUIDE ACCORDING TO THE 2012 IRC WITH THE 2016 CT AMMENDMENTS

Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Campbell County Building Inspection Division Guideline to 2018 IRC Residential Construction for Decks

Stairs have many potential violations this Newsletter is Part 1 of two parts.

2003 International Residential Building Code

RESIDENTIAL BUILDING REQUIREMENTS

FACT SHEET #2 DECK INFORMATION

BENZIE COUNTY BUILDING SAFETY and CODE ENFORCEMENT DEPARTMENT 448 Court Place, Beulah, Michigan Ph Fax.

Residential Deck Guide

2. Plot plan showing deck scaled with stairs. 3. Building Permit Application signed by owner or licensed contractor and fee paid.

* RESIDENTIAL PLAN REVIEW *

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

DECKS CHAMPLIN BUILDING DEPARTMENT DECK PERMIT REQUIREMENTS:

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

Town of Chili. Building Department 3333 Chili Avenue, Rochester, NY (585) fax: (585) Decks: What You Need to Know

Work Group Item Stairways serving an occupant load of less than 50 shall have a width of not less than 36 inches (914 mm).

Administrative Changes

Residential Decks. NOTE: If you are in a development with a 2. Deck Plan (see below)

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

-=== Building Safety Departnlent 'Neil Avenue, Room 202 Cheyenne, WY Phone: (307) Fax: (307) RAMPS

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

14240 W. 151 st Street, Homer Glen, IL Phone Fax Deck Building Guide

EGRESS CHAPTER ,500 3 Over 2,500 4 OCCUPANT LOAD REQUIRED MEANS OF EGRESS

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

Deck Construction Guide

RESIDENTIAL REMODELING AND BASEMENT FINISH

Attached are examples of drawings which are intended as a GUIDE ONLY!!

RESIDENTIAL DECK INFOREMATION SHEETS

Standard for Bleachers, Folding and Telescopic Seating, and Grandstands

Residential Building Plans

Advanced FBC: Significant Changes to the 5 th Edition (2014) Florida Building Code, Building and Residential. presented by

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

DEVELOPMENT SERVICES BUILDING INSPECTIONS

1 & 2 Family Deck Permits City of Oshkosh Inspection Services Division

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

City of St. Peters Residential Deck Guide

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Manufactured decking (composite) may be used when approved by the building department

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

Why do we need to learn about Stairs

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

******************************************************************************

City of of Dauphin WOOD DECKS. Zoning and construction requirements for non-sheltered wood decks for residential dwellings.

CLEAR CREEK COUNTY BUILDING DEPARTMENT REQUIREMENTS FOR A SINGLE FAMILY RESIDENCE

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

FBC 5 th Edition. General. Update to the Florida Building and Residential Codes Updates to the Florida Building and Residential Codes

Wood Decks. Zoning and Construction requirements for open non-sheltered wood decks for residential dwellings.

COVERED AND SCREENED PORCHES: WHAT YOU NEED TO KNOW

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

RESIDENTIAL DETACHED ACCESSORY STRUCTURES

RESIDENTIAL BUILDING CODE HANDOUT REFERENCES: 2015 Michigan Residential Code

Building a Wood Deck, Gazebo, or Pergola

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

SAFEGUARDS DURING CONSTRUCTION

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings

DECK INFORMATION SHEET

Chapter WAC Construction Work

Uncovered Decks & Porches

TOWN OF ROTTERDAM BUILDING DEPARTMENT RESIDENTIAL ACCESSORY BUILDINGS AND STRUCTURE PERMIT APPLICATION Ext 395

Screen & 3-Season Porches

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Introduction 2 The Guidance Existing Buildings Technical Specifications Materials and Workmanship Interpretation. Part K : The Requirement 3

Residential Decks 1 & 2 Family Dwellings and Townhouses City of Owatonna BUILDING DEPARTMENT

North Strabane Township

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

The permit holder is ultimately responsible for compliance with all aspects of the building code.

Guide to Handrail. & Guard Railing. Building Codes. and Standards. Committed to Providing Superior Value to Our Customers PEOPLE PRODUCT PERFORMANCE

RESIDENTIAL DECK SUBMITTAL GUIDE

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Elko County Building & Safety Division

SFR SUBMITTAL REQUIREMENTS

Excerpts from: International Residential Code 2009

CITY OF BATAVIA DECK CONSTRUCTION REQUIREMENTS

This permit is issued under OAR Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days.

Oregon Building Officials Association

Decks & Patios Version 4/24/2015

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

Wood Decks. Please call for further information. Municipality of Roblin Planning Department st Ave. NW Roblin, Manitoba R0L 1P0

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

Transcription:

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017) It is the responsibility of the permit applicant to notify the building inspector when the work is ready for inspection. To request an inspection, call Eric Eneboe at (605) 321-4783 and leave a message if necessary. Allow 24 hours notice. Foundation inspection. Inspection of the foundation shall be made after the trenches or basement areas are excavated and any required forms erected and any required reinforcing steel is in place and prior to the placing of concrete. The foundation inspection shall include excavations for thickened slabs intended for the support of bearing walls, partitions, structural supports, poles or piers, and special requirements for wood foundations. Frame and masonry inspection. Inspection of framing and masonry construction shall be made after the roof, masonry, all framing, fire stopping, draft stopping and bracing are in place and after the rough plumbing, mechanical and electrical items are in place. Final inspection. Final inspection shall be made after the permitted work is complete and prior to occupancy. CERTIFICATE OF OCCUPANCY. No building or structure shall be used or occupied until the building official has issued a certificate of occupancy or final inspection tag. Unlawful acts. It shall be unlawful for any person, firm or corporation to occupy any building or structure regulated by code until Certificate of Occupancy is issued. The State of South Dakota also requires plumbing & electrical inspections. The following information is being provided to enable you the holder of the building permit to comply with the various required inspections. PLUMBING: Contact SD Plumbing Commission 1-605-773-3429 Homeowner plumbing permit: www.plumbing.sd.gov.homeownerplumbing ELECTRICAL: Contact SD Electrical Commission 1-800-233-7765 or 1-605-773-3573 Homeowner wiring permit: www.wiring.sd.gov.homeownerwiring Thank you for your participation and compliance with the inspection requirements. Questions pertaining to the above can receive a response by calling the undersigned at (605) 764-2938. Toby Brown Director, Planning and Zoning Other Important Phone Numbers: South Dakota One Call: 811 (In State) or 1-800-781-7474 (Outside SD) (Locates your underground lines) Lincoln County Rural Water: (605) 767-2966 *South Lincoln County Rural Water: (605) 372-4211 *Possible restrictions in effect

BUILDING PERMIT CHECKLIST Provide applicant with the handout stating the required inspections If permit is for commercial building (excluding single family dwellings and agriculture sheds), the following should be required: Classification: Assembly Group A A-1, A-2, A-3, A-4 & A-5 Business Group B Educational Group E Factory Group F F-1 & F-2 High-Hazard Group H H-1, H-2, H-3 & H-4 Institutional Group I I-1, I-2, I-3 & I-4 Mercantile Group M Residential Group R R-1, R-2, R-3 & R-4 (excludes single family) Storage Group S S-1 & S-2 Utility and Misc. Group U Fuel load for the building: This includes all solid, liquid, and gaseous combustibles that will be present in the building. Building plans showing egress exits: Generally, any area requiring more than one exit must have illuminated signs and pathways with an emergency 90 minute backup. Two exits are required if the exit travel distance is greater than 75 feet measured at right angles at any point in the building. These exits will generally be required to be accessible with no bolt locks. Buildings over 10,000 sq. ft. may require professionally engineered plans. This does not preclude the building department from requiring engineered plans for any project if deemed necessary. Townhouses, apartments, and other multi-family dwellings require approval of inspector before issuing permit. This will allow applicant to be aware of dwelling unit separation requirements before commencement of project.

STAIRS, HANDRAILS, & GUARDS Stair treads and risers. Riser height. The maximum riser height shall be 8 inches. The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Tread depth. The minimum tread depth shall be 10 inches. The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread s leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Winder treads shall have a minimum tread depth of 10 inches measured as above at a point 12 inches from the side where the treads are narrower. Winder treads shall have a minimum tread depth of 6 inches at any point. Within any flight of stairs, the greatest winder tread depth at the 12 inch walk line shall not exceed the smallest by more than 3/8 inch. Handrails. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches and not more than 38 inches. Continuity. Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly above lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1 ½ inch between the wall and the handrails. Exceptions: 1. Handrails shall be permitted to be interrupted by a newel post at the turn. 2. The use of a volute, turnout, starting easing or starting newel shall be allowed over the lowest tread. Handrail grip size. All required handrails shall be of one of the following types or provide equivalent grasp ability. 1. Type I. Handrails with a circular cross section shall have an outside diameter of at least 1 ¼ inches and not greater than 2 inches. If the handrail is not circular it shall have a perimeter dimension of at least 4 inches and not greater than 6 ¼ inches with a maximum cross section of dimension of 2 ¼ inches. 2. Type II. Handrails with a perimeter greater than 6 ¼ inches shall provide a graspable finger recess area on both sides of the profile. The finger recess shall begin within a distance of ¾ inch measured vertically from the tallest portion of the profile and achieve a depth of at least 5/16 inch within 7/8 inch below the widest portion of the profile. This required depth shall continue for at least 3/8 inch to a level that is not less than 1 ¾ inches below the tallest portion of the profile. The minimum width of the handrail above the recess shall be 1 ¼ inches to a maximum of 2 ¾ inches. Edges shall have a minimum radius of 0.01 inches.

GUARDS Guards required. Porches, balconies or raised floor surfaces located more than 30 inches above the floor or grad below shall have guards not less than 36 inches in height. Open sides of stairs with a total rise of more than 30 inches above the floor or grade below shall have guards not less than 34 inches in height measured vertically from the nosing of the treads. Porches and decks which are enclosed with insect screening shall be provided with guards where the walking surface is located more than 30 inches above the floor or grade below. Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 5 inches or more in diameter. Exception: The triangular opening formed by the riser, tread and bottom rail of a guard at the open side of a stairway are permitted to be of such a size that a sphere 6 inches cannot pass through.

CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA TABLE 2/R301.2(1) IRC Ground Snow Load. 40 psf Ground Snow Load (Figure R301.2(5) Ground Snow Load, P(g) for the United States IRC) for engineered designs. On roof systems that are not engineered, conventionally framed roof slopes with a rise of 3 inches or less to 12 inches shall be designed for a full or unbalanced snow load of not less than 30 pounds per square foot of horizontal projection. Where a roof system is designed to slope less than ¼ inch per 12 inches, a surcharge load of not less than 5 pounds per square foot in addition to the required live load due to snow shall be designed into the roof system. Roof slopes with over 3 inches of rise per 12 inches shall be designed for a full or unbalances snow load of not less than 25 pounds per square foot of horizontal projection. Potential unbalanced accumulation of snow at valleys, parapets, roof structures, and offsets in roofs of uneven configuration shall be considered. Wind Speed. 115 mph. (Figure R 301.2(4)A. Ultimate Design Wind Speed. IRC; When an engineered design is deemed necessary, the wind exposure category shall be determined on a site specific basis. Seismic Design Category. Seismic Zone A. (Figure R301.2(2) Seismic Design Categories in accordance with Section R 301.2.2.2 IRC. Weathering. Severe. (See Figure R 301.2(3), Weathering Probability Map IRC; Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of the code.) Frost Line Depth. 42 inches Termite Damage. Slight to Moderate. (Figure R 301.2(6) IRC) Winter Design Temperature. -11.5 degrees Fahrenheit (Ice shield underlayment required) Mean Annual Temperature. 46 degrees Fahrenheit.