Top Ten List: What Gets Metal Roof Designers in Trouble?

Similar documents
TYPICAL ROOF CONDITION LAYOUT

Metal to the metal. by W. Lee Shoemaker, Ph.D., P.E. and Vincent E. Sagan, P.E. and Dale Nelson

Metal Roofing. The Devil is in the Details SSRLU3B. I LU/HSW Hour

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

the re-cover option, there are several elements to keep in mind to achieve proper longevity of the new roof system. Replacement vs.

Architectural Roof and Wall Products Guide Specifications

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

238T Aluminum Standing Seam Metal Roof System (SSMRS)

Architectural Wall Products Guide Specifications

SECTION METAL ROOF PANELS

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

Architectural Roof and Wall Products Guide Specifications

DL-200. Specifications

CONSTRUCTION DETAILS HANDBOOK

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS

SSL-175. Specifications

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

SECTION COPPER STANDING SEAM ROOFING

Tuscaloosa Police Station

Engineered Roof Solutions

a division of NCI Standing Seam Roof Systems

STANDING SEAM METAL ROOFING. Presented by MBCI Credit: 1 AIA LU/HSW AIA course number: SSRLU2B

Sheet Metal Flashing and Trim

Trusted Tested Tough Kalaeloa Blvd, Kapolei, Hawaii Phone (808) Fax (808) Neighbor Islands (800)

SECTION METAL ROOF AND SOFFIT PANELS

Hawthorne Fire Station Repairs Section Page 1 of 8

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

SECTION STANDING SEAM METAL ROOFING

Light-Metal Roof Edge, Raised

SECTION ROOF SPECIALTIES

SECTION STAINLESS STEEL WALL PANELS

New McElroy Metal retrofit systems price-competitive with single-ply

ROOF MITIGATION STRUCTURE EVALUATION FORM. For Single Family Residential Re-Roof Effective October 1, 2007 (Revised February 2, 2018)

SECTION STANDING-SEAM METAL ROOF PANEL

Metal Roof Panels

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

Update In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING

CS-100 Guide Specifications

UltraLok Roof System Product Application Guide INDEX

Roofing City of Owatonna BUILDING DEPARTMENT

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

Project Name Project # Project Information

SECTION 07530CP EPDM MEMBRANE ROOFING

DIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING

Metal Roof Installation Manual. Chapter 7: Panel Connections

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Metal Retrofit Systems from Royalty Roofing

ADDENDA #5- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services

SECTION BATTEN SEAM COPPER ROOFING

The Experts in Retrofit Design. Retrofit Solutions. Retro-R SSR NuRoof NuWall

Corium Brick Rainscreen System Specifications

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

North Hanover Township School District North Hanover Township, New Jersey

TRIAD CORRUGATED METAL, INC.

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

INSTALLATION GUIDE.

DIVISION 7 THERMAL AND MOISTURE PROTECTION

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

BASIC VENTILATION REQUIREMENTS

SRP-AirOutshield ROOF Issued:

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten

BUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3

SECTION PRE-ENGINEERED METAL BUILDING

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

Installation Guide. Mission Tile. Distributed by: BEST MATERIALS LLC, Phoenx AZ

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

Classic and NB Tile Counter Batten and Batten

DUKE UNIVERSITY CONSTRUCTION STANDARDS

University of New Hampshire Scholars' Repository

SL150 Guide Specification

ML150 Guide Specification

Page 1 of 5

SECTION AWNINGS

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

CRCA Education Series. Self-Adhering Membrane Roofing Systems for Low Slope Roofs

1 Exam Prep NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012 Tabs and Highlights

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

WeatherSmart Air Barrier Installation Guide

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011

STANDING SEAM ROOF SYSTEM. Nucor CFR

Product Guide Specification

TECHNICAL INFORMATION

CONTINUOUS VENTILATORS

SECTION ROOFING AND SIDING PANELS

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

Transcription:

Top Ten List: What Gets Metal Roof Designers in Trouble? Brian Gardiner, FRCI, RRC, CCS BMG Enterprises, LLC 180 elvira, Canyon lake, TX 78133 Phone: 512-784-3791 e-mail: brian.bmgent@gmail.com Charlie Smith McElroy Metal 1500 Hamilton Rd., bossier City, la 71111 Phone: 318-747-8000 E-mail: csmith@archmetalroof.com 3 2 n d R C I I n t e R n a t I o n a l C o n v e n t I o n a n d t R a d e S h o w M a R C h 1 6-2 1, 2 0 1 7 g a R d I n e R a n d S M I t h 2 1 7

Abstract Sheet metal is a unique roof system choice that continues to evolve into new systems applications. Metal roofs are gaining market share in both commercial residential markets. Building owners have a high performance aesthetic appeal expectation for metal roofs. This evolution comes with problems. The speakers will present their top ten problems for metal roof designers. This will include a description of the problem, why it may occur, ramifications, how to prevent it through proper design. The presenters draw from over 50 years of combined metal roofing experience. Speakers Brian Gardiner, FRCI, RRC, CCS BMG Enterprises, LLC, Canyon Lake, TX BRIAN GARDINER has practiced roof consulting for over 32 years. He is a past director of both RCI s Region IV (1995-1998) the Building Envelope Institute, Inc. (2005-2006). Gardiner has created presented numerous roofing-related seminars for RCI, including its two-day Metal Roofing course. He has specified, provided detail drawings, reviewed workmanship for millions of square feet of metal roofing. Gardiner s experience also includes several evaluations of failed metal roof systems. Charlie Smith McElroy Metal, Inc., Houston, TX CHARLIE SMITH founded Architectural Building Components in 1989. Over the next 23 years, the company grew into an industry-leading metal roofing wall system solution provider specializing in the use of metal to re-cover existing sloped roofs. In 2012, his company became a part of McElroy Metal. This enabled Smith to focus on educational product development efforts to help the roofing industry design creative solutions with metal. Smith holds several patents relating to metal re-cover recently co-wrote the new RCI Metal Roofing course with Brian Gardiner. 2 1 8 g a R d I n e R a n d S M I t h 3 2 n d R C I I n t e R n a t I o n a l C o n v e n t I o n a n d t R a d e S h o w M a R C h 1 6-2 1, 2 0 1 7

Top Ten List: What Gets Metal Roof Designers in Trouble? OvERvIEW Ever-greater dem for metal roofs has resulted in an increased need for education of designers who are not familiar with metal roofs, but now have been asked by their client to design one. Unfortunately, building owners frequently have a higher performance aesthetic expectation for metal roofs. Metal roof failures are typically more costly than failures associated with other commercial roof choices. This paper is intended to provide a review of the authors top ten list of problems for metal roof designers describe how to prevent problematic conditions. Consider adding these items to the agenda of a pre-roofing meeting, if one of these conditions exists on your particular project. Also consider the value of a roofing manufacturer-produced shop drawing a contractor-fabricated mock-up before work commences. INTERNAL GUT TER S Sloped crickets (aka saddles) are designed to slope to roof drains or scuppers on membrane roofs that slope to a wall. When a metal roof is designed, an internal gutter is installed at the wall, also known as a concealed gutter (Figure 1). This gutter is much more problematic should be deleted during the design phase of a new building eliminated in a reroof if feasible. If this is unavoidable, the utmost attention must be given to design, detailing, specification, quality assurance by the designer. Unlike conventional gutters, an internal gutter is commonly part of the thermal envelope, bringing the challenge of how to insulate prevent condensation problems on the underside of a gutter exposed to interior conditioned space. Consult with local contractors metal roof manufacturers in the building s geographic area. Consider specifying a heavy-gauge, welded, 300-series stainless steel, with welded endcaps, expansion joints, outlet tubes to connect to drain piping, welded scupper outlets for secondary drainage (Figure 2). Consider more robust primary secondary drainage provisions than the building code requires to prevent water debris accumulation. Insulate the underside to maintain the building s thermal envelope, install an air/vapor retarder to prevent condensation. Determine specify local proven methods to allow thawing in the gutter in ice snow regions. If a gutter liner or a membrane roof with saddles conventional drains is specified, design a method to allow removal replacement without having to remove upslope roof panels. The liner roof membrane will typically have a shorter life expectancy than the metal roof panels. Metal roofs over retail office space appear to be the most susceptible building types, as a storefront appearance is desired, roof height ( structural cost) are reduced by sloping metal roofs to a front wall, with a ridge in the mid-span. The same mindset that strived to save money on the building cost, unfortunately sometimes translates into trying to do the same with the internal gutter design. This is one potential problem worth walking (running!) away from if the building owner is not willing to invest in a sufficient design. valleys Often, valleys are the major source of water infiltration on metal roofs. Consider roof panel seam type choice when designing a roof with valleys. Roof panel seams that require a closure at eaves, such as trapezoidal, are more difficult to seal at an angle where it intersects valley flashing. Review manufacturers details for roof valley design related to closures, back-up plates, other accessories to incorporate into detail drawings. Figure 1 Internal gutter at parapet wall. Figure 2 Stainless internal gutter with welded scupper outlet tube. 3 2 n d R C I I n t e R n a t I o n a l C o n v e n t I o n a n d t R a d e S h o w M a R C h 1 6-2 1, 2 0 1 7 g a R d I n e R a n d S M I t h 2 1 9

Figure 3 One-piece stainless dormer valley transition. Figure 4 One-piece stainless steel dropped down, with curved valley flashing. It is important to divert water down out via the valley. Consider designing a diverter in the middle to help prevent water from crossing the valley to the other side. Usually, a 1.5- to 2-inch height of the valley diverter is sufficient, but certain designs may require a higher diverter when a large roof area drains onto a lower dormer valley. It is particularly difficult to provide a long-term design solution for a valley that terminates at a dormer into the lower roof. Consider a soldered or welded one-piece transition flashing at the intersection of the dormer valley with the main roof area (Figure 3). There are several designs of valley flashings for a metal roof: those with hems, those without. Discuss with contractors manufacturers what designs have been successful in your geographic area. Valleys that are fabricated with integral hems require a high degree of workmanship to fabricate the lap joint. They should be fabricated in full length or tapered so the 220 SMIth ends nest into one another without cutting out hems. It is recommended that the contractor provide a mock-up of the valley lap joint to ensure proper fabrication. Another design is to detail an offset cleat. The cleat can be set in sealant tape fastened through the valley into the deck or structure below. Another solution is a double cleat that allows the panel to be hooked into the valley trim with no penetrations, providing a simple lap joint. On valleys installed on open-frame applications, consider specifying a 48-inch-wide, heavy-gauge backup plate under the valley with a water-resistant, self-adhesive membrane on top. Allow for water that may enter to weep at valley eave terminations. On lower-slope jobs or retrofit applications, dropping the valley below the plane of the roof may help with drainage, in effect constructing a valley gutter. In cold-weather regions, this will help thaw the ice snow at the valley first. Water flow is controlled below the plane of the panels, which helps decreases the width of the valley pan. Figure 5 Stainless steel pipe penetration flashing base with welded end.

Figure 6 Cricket on uphill side of one-piece stainless curb. Figure 7 Transverse panels used on low-slope applications uphill of curbs. On curved valleys, consider specifying a welded or soldered stainless steel valley (Figure 4). Curved valleys make it difficult to construct a watertight flashing. Discuss with local contractors manufacturers to determine what has been successful locally. ROOF PENETRATIONS Although flashing roof penetrations is typically a simple process with the products available today, these flashings continue to be a potential leak source. Specify detail pipe penetrations in the middle of the panel with at least 2 in. of clearance between the seam the pipe boot to allow water flow prevent debris accumulation. If intersecting the seam is unavoidable, consider detailing a stainless steel pan that spans two roof panels, integrates into the adjoining seams, provides a flat surface to seal the pipe penetration flashing. Detail a welded end cap that goes over the panel seam(s) on the low side of the pan (Figure 5 ). Include provisions in the specifications to include the penetration flashing in the weathertightness warranty. Manufacturers may require a particular type of boot. Specify a high temperature-rated boot when flues or other hot pipes are flashed. Detail a stainless steel drawb to ensure a tight seal at boot intersection with vent pipe. CURBS Consult with the selected roofing manufacturer to determine which third-party curb manufacturers are acceptable have the ability to fabricate sting seams to integrate with a roof panel seam. Specify a one-piece, welded stainless steel or aluminum curb, detail a shingle-fashion installation, with no back-water joints. Determine anticipated loads on curbs the need for a structural curb separate from the roof curb that floats with the roof panels. Specify detail curbs with integral crickets on the upslope side to prevent debris ponding water accumulation (Figure 6 ). When numerous large curbs are located on a metal roof, consider detailing raised platforms behind the curbs with sting-seam roof panels that drain onto the lower main roof (Figure 7 ). SMIth 221

Figure 8 Retrofit frame being constructed on built-up roof. Figure 9 Compact retrofit assembly over existing R panel. RETROFITS Metal roof retrofits come in two varieties, each with their own design challenges. One version is a sloped metal structure over an existing low-sloped membrane roof when an attic space may be created (Figure 8). The other is a compact assembly in which the new metal roof is placed over the existing roof, usually with insulation in between (Figure 9). In both scenarios, the original structure needs to be evaluated by a licensed design professional for additional dead load wind uplift resistance. The existing building s structure may require enhancement to meet the current building code. A retrofit with a new framing system constructed to add slope should be reviewed by the designer for uniform loading across the existing structure, rigid attachment to the structure, to ensure that local fire codes are complied with related to creating a new attic space. Other design decisions include what to do with the existing roof Figure 10 Roof collapse of single ply over metal building retrofit. 222 SMIth membrane encapsulated rooftop equipment. Consult the owner s property insurer to determine what additional design features he or she recommends be implemented. Retrofit frames may need to be attached to every bar joist for uniform loading of the existing structure. In order to create a rigid attachment, it may be necessary to cut holes in the existing roof system to connect directly to the structure. This can create a waterproofing challenge during construction of the retrofit frame system. Include detailed temporary waterproofing specifications details that indicate how to keep the building interior dry. There are stories of entire schools being flooded by several unintended roof drains created by holes for structural attachment. Many pre-engineered metal buildings are designed for balanced loading across the entire structure. Purlins are run straight with no camber, so when they are installed, they naturally deflect downward between the main rafters. When

Figure 11 Previous repair attempts at roof pitch change. Figure 12 Roof panel endlap. there is a ribbed metal roof in place, water is controlled between the ribs of individual panels for equal loading on the structure. Re-covers over an existing metal roof with a smooth-surface membrane roof allow water to flow to purlin mid-span. Localized ponding over a deflected purlin increases over time as ponding water increases with increased deflection. As the deflection accumulates more more water forces the weak purlin down in the affected bay, the purlins in the two adjacent bays will rise. Eventually, this can divert water from adjacent bays into the affected bay. The result can be catastrophic (F igure 10 ). When designing a compact retrofit over an existing metal roof, it is important to consider the type of structure that is being re-covered. An existing metal building with spaced purlins performs differently than a structure with bar joists a steel deck. Bar joists a steel deck will distribute loads more evenly. Re-covering an existing metal roof over this kind of structure can be done by several methods. A metal roof on a metal building is attached directly to C- or Z-shaped purlins, which are lapped connected to each other over the top of each rafter. Equal loading across each purlin is critical to the proper functioning of metal building roof framing. specifications for a shop drawing. Consult with the manufacturer for warranted detail requirements for their particular roof panel system. Include a specification provision to review a mock-up before proceeding with installation. Detail redundancy, such as a double-closure water-resistant barrier backup, in extreme circumstances (i.e., a large roof area draining onto the flashing, or if the project is in a cold weather region). ENDLAPS Metal roof panel endlaps are a major source of leakage. Avoid roof panel endlaps by specifying continuous length panels where possible. Where endlaps are unavoidable, consult with the manufacturer for requirements, incorporate them into specifications detail drawings. Manufacturers will often have a very detailed procedure material list for endlaps to comply with their warranty ROOF SLOPE TRANSITIONS When a steep-sloped roof intersects a lower sloped roof, it is prone to leakage (F igure 11). If possible, reconfigure the roof design to eliminate slope transitions. If transitions are unavoidable, provide a detail drawing include a requirement in the Figure 13 Severe oil canning on curved roof. SMIth 223

then be used as a stard of care for the remaining roof areas. This in-situ mock-up can also be valuable in review of seaming, clip-spacing, attachment, insulation, underlayment, other items. This small area of roof can prove very beneficial if there is a question as to installation aesthetics on subsequent roof areas. ROOF PANEL SELECTION Figure 14 Planks pencil ribs help reduce oil canning. requirements (F igure 12 ). Specify a detailed shop drawing indicating endlap accessories, fastening patterns, sealant(s). Include in specifications the coordination necessary to review initial installation of endlaps by a roof observer in the presence of the roofing manufacturer s technical representative. Attempting to repair a roof with poorly constructed endlaps is very disruptive to roof panels will often shorten roof life expectancy. that has incorporated oil-canning reduction techniques to determine if they have resulted in an acceptable aesthetic for the architect owner. Specify an in-place 30-ft.-wide section of roof mock-up for review by the owner architect prior to installing remaining panels to review oil-canning. This can There are several roof panels available for the designer to choose from. Each has its own list of advantages disadvantages. A few of the many properties important to selection include roof slope, geographic area, wind-resistance, hydrokinetic vs. hydrostatic, structural vs. nonstructural, ease of repair/modifications, finishes, aesthetic qualities. Discuss with local contractors manufacturers what has performed well in the project s area. Review the project characteristics with roofing manufacturers to ensure that the selected panel(s) provide the desired characteristics. Choosing an incorrect roof panel can have significant ramifications, especially if not corrected prior to installation. OIL CANNING Building owners frequently have a higher performance aesthetic expectation for metal roofs, especially those on a steep slope. Oil-canning or waviness in the flat portion of the metal roof panel is inherent in the sheet metal used for metal roofs. It is somewhat subjective; what is acceptable to one person may not be to the next (F igure 13 ). Steps can be taken in the specifications to significantly reduce the amount of perceivable oil-canning, such as incorporation of striations, planks, or pencil ribs to help stiffen the flat portion of the roof panel (F igure 14). Discuss with the roof panel manufacturer how to reduce oil-canning in their particular roof panel, coordinate potential methods with architect owner. Visit a recently completed project Figure 15 Retrofit with enhanced attachment at perimeter. 224 SMIth

WIND UPLIFT Just as there are several roof panels to select from, there are also several methods to achieve code-compliant metal roof wind uplift resistance. Existing metal buildings may not have enhanced structures to accommodate current design wind pressures, especially if the building is classified as partially enclosed. Depending on slope configuration, metal roofs can have additional roof areas that are in the enhanced uplift zones. The design safety factor can also vary, depending on the authority having jurisdiction possibly the number of uplift tests by the manufacturer. Depending on particular project characteristics, consider specifying a structural engineer-sealed roof plan(s) submittal indicating purlin layout, wind uplift zones, roof panel layout. A particular roof panel wind uplift performance can vary depending on panel gauge, base metal properties, panel width, seam properties, type of clips, clip spacing, substrate characteristics. It is important to match all these properties that were laboratory tested with what is specified detailed. Review wind uplift design specifications with the roof panel manufacturer to determine what panels accessories would comply with each of the wind uplift zones (Figure 15 ). SUMMARY Metal roofing has several characteristics that are different than other commercial roof choices. RCI, Inc. SMACNA have recently produced a publication entitled the Architectural Sheet Metal Quality Assurance Guide that has design quality assurance information for both the metal roof designer the roof observer. RCI has a two-day metal roofing course that has several chapters involving metal roof design installation. Metal roofing manufacturers may offer training on their particular roof system that would be valuable for the observer. Experienced local metal roofing contractors can be a very valuable source of information for what has performed well in their area. The metal roof manufacturer may provide on-site technical assistance during construction, especially for systems intended to have a weathertightness warranty. A metal roof can certainly provide long-term service if well-designed installed according to proven techniques. 3 2 n d R C I I n t e R n a t I o n a l C o n v e n t I o n a n d t R a d e S h o w M a R C h 1 6-2 1, 2 0 1 7 g a R d I n e R a n d S M I t h 2 2 5