mdi Micro Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

Similar documents
mdi Nano Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

mdi Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

mdi Stool Genomic DNA Miniprep Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

mdi Medi-R Total RNA PLUS Miniprep Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies

mdi Quanta Midi Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

mdi Endotoxin Free Quanta Maxi Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

mdi Quanta Giga Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

mdi Endotoxin Free Quanta Mega Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

mdi Genomic DNA Miniprep Kit User Guide >> Animal (Mammalian) Tissue >> Bacterial Cells >> Blood >> Cultured Cells ADVANCED MICRODEVICES PVT. LTD.

BIO BASIC. Gel Extraction Kit. 9K s (10 preps) 9K (100 preps) 9K (200 preps) For Research Use Only

Gel/PCR Extraction Kit

TIANgel Mini DNA Purification Kit

Product # Specifications. Kit Specifications Column Binding Capacity. 10 g Maximum Weight of Gel Slice Average DNA Recovery 70 90%

PureSpin. Gel DNA Purification Kit. Micro Columns INSTRUCTION MANUAL. KIT COMPONENTS For Research Use Only. PureSpin.

Description...1 Components...1 Storage... 1 Technical Information...1 Protocol...2 Examples using the kit...4 Troubleshooting...

Bead Type (NaI) Gel Extraction Kits

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

Plus DNA Clean/Extraction Kit

EZ-10 SPIN COLUMN HANDBOOK

GeneJET Gel Extraction Kit #K0691, #K0692. }!tc!!!#!!h~ PA-K069

BIO BASIC. PCR Purification Kit. 9K s (10 preps) 9K (100 preps) 9K (200 preps) For Research Use Only

User Bulletin. Shipping & Storage. Gel/PCR DNA Isolation System. Protocol. WARNING: strong acids and oxidants (such as bleach) should not

Gel Extraction & PCR Purification Combo Kit (Spin-column)

Gene-Spin DNA Purification Kit - V3

Introduction. Kit components. 50 Preps GF-PC-050. Product Catalog No. 200 Preps GF-PC Preps GF-PC Preps SAMPLE

Kit for total DNA isolation from agarose gels

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

Kit for total DNA isolation from agarose gels

GenepHlow Gel Extraction Kit

TaKaRa MiniBEST Agarose Gel DNA Extraction Kit Ver.4.0

Kit for total DNA purification and isolation from agarose gels

Sequencing Reaction Clean-Up Kit Product # 34500

PureLink Quick Gel Extraction Kit

Genomic DNA Extraction Kit (Tissue)2.0

Micro-Elute DNA Clean/Extraction Kit

DNA Visualizer Extraction Kit

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085

Gel Extraction Mini Spin Column Kit. UltraPrep Gel-Ex. Purification of DNA fragments and plasmids from agarose gels

Genomic DNA Extraction kit (Cultured Cell) 2.0

TIANquick Mini Purification Kit

Unzipping Genes MB563 HiPurA TM PCR Product and Gel Purification Combo Kit

Thermo Scientific GeneJET NGS Cleanup Kit

FavorPrep Blood / Cultured Cell Genomic DNA Extraction Maxi Kit. User Manual

Large DNA Fragments Extraction Kit

June MinElute Handbook. For. MinElute PCR Purification Kit MinElute Gel Extraction Kit MinElute Reaction Cleanup Kit

INDEX KIT COMPONENTS 1 STORAGE AND STABILITY 1 INTRODUCTION 1 BENEFITS

foodproof Sample Preparation Kit III

Size-Select Kit for NGS Library Preparation Product # 53600

Plasmid DNA Isolation Column Kit Instruction Manual Catalog No. SA-40012: 50 reactions SA-40011: 100 reactions

HiPer Gel Extraction Teaching Kit (Column Based)

Presto Mini Plasmid Kit

Zymoclean Large Fragment DNA Recovery Kit

E.Z.N.A. Gel Extraction Kit

Monarch DNA Gel Extraction Kit

Instructions for Use

Geneaid Maxi Plasmid Kit & Geneaid Maxi Plasmid Kit (Endotoxin Free)

Presto Food DNA Extraction Kit

AxyPrep PCR Clean-up Kit AxyPrep-96 PCR Clean-up Kit

EZ-10 SPIN COLUMN GENOMIC DNA MINIPREPS KIT HANDBOOK

TIANamp Marine Animals DNA Kit

FavorPrep Viral Nucleic Acid Extraction Kit I. User Manual. For Research Use Only

PCR and Sequencing Reaction Clean-Up 96-Well Kit (Magnetic Bead System) Product # 62700

PureColumn DNA Extraction Kit

Viral Nucleic Acid Isolation

User manual. Invisorb Spin DNA Extraction Kit ** Invisorb Fragment CleanUp***

PureColumn DNA Extraction Kit

Zymoclean Large Fragment DNA Recovery Kit Catalog Nos. D4045 & D4046

Soil DNA Extraction Kit

Genomic DNA Extraction Mini Kit (Blood and Urine)

Geneaid DNA Isolation Kit (Yeast)

PureSpin DNA Clean Up Kit

Fast and reliable purification of up to 100 µg of transfection-grade plasmid DNA using a spin-column.

Genomic DNA Clean & Concentrator -25 Catalog Nos. D4064 & D4065

PureColumn DNA Extraction Kit

ISOLATE II Blood DNA Kit. Product Manual

Instructions for Use Life Science Kits & Assays

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

Presto Mini gdna Bacteria Kit

I-Blue Midi Plasmid Kit. I-Blue Midi Plasmid Kit. (Endotoxin Free) IBI SCIENTIFIC. Instruction Manual Ver For Research Use Only.

Presto Stool DNA Extraction Kit

Eluted DNA is high quality and inhibitor-free making it ideal for PCR and genotyping.

Chromatrap 96 DNA Micro Elution Purification Kit

India Contact: Life Technologies (India) Pvt. Ltd.

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Sequencing Reaction Clean-Up 96-Well Kit Product # 34400

Blood DNA Extraction Kit

MD60002 MD MD62002

Thermo Scientific GeneJET Plant Genomic DNA Purification Mini Kit #K0791, #K0792

Product # Specifications. Kit Specifications Binding Capacity Per Well. 15 g Maximum Loading Volume Per Well 500 L

FavorPrep Soil RNA Isolation Mini Kit

Plasmid DNA Extraction Miniprep Kit

For Research Use Only Ver

Presto Soil DNA Extraction Kit

SPEEDTOOLS PLASMID DNA PURIFICATION KIT

RayBio Genomic DNA Magnetic Beads Kit

Thermo Scientific GeneJET Whole Blood RNA Purification Mini Kit #K0761

Specifications. Kit Specifications. Alcohol Precipitation: Up to 100 ml Column Purification: Up to 5 ml Column Binding Capacity 25 µg

Transcription:

Micro Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. 21, Industrial Area, Ambala Cantt - 133001 (INDIA) ADVANCED Tel: 0171-2699290, MICRODEVICES 2699471, 2699274 PVT. LTD. 21, Fax: Industrial +91-171-2699221, Area, Ambala 2699008 Cantt - 133006 (INDIA) Tel: Email: 0171-2699290, mdi@vsnl.com 2699471, 2699274, Fax: +91-171-2699221, 2699008 Email: Website: info@mdimembrane.com, www.mdimembrane.comwebsite: www.mdimembrane.com mdi Membrane Technologies

Table of Contents Page 1. Introduction 3 2. Applications 3 3. Storage Conditions 3 4. Quality Assurance 4 5. Safety Information 4 6. Lot Release Criteria 4 7. Technical Support 5 8. Kit contents 5 9. Specifications 6 10. Principle 7 11. Important Points to be Considered 8 12. mdi Micro Gel Extraction Procedure 9 13. Protocol 10-11 14. Trouble Shooting Guide 12-13 15. Product Use Limitations 14 16. Product Warranty and Satisfaction Guarantee 15 17. Ordering Information 16 Page 2 of 16

1. Introduction mdi Micro Gel Extraction Kit is a quick, convenient and economical tool to obtain highly concentrated DNA fragments (70bp-4kb) after gel analysis from standard or low melt Agarose gel. The buffer system provided in the kit facilitates efficient binding of DNA fragments from solublised gel slice onto the spin column. Washing is done with help of wash buffers in order to remove agarose gel, salts, and other impurities from DNA samples. Purified DNA is eluted in small volumes (10µl) of low salt buffer or water for variety of downstream applications. 2. Applications 1. Automated Fluorescent Sequencing 2. Radioactive Sequencing 3. Restriction Digestion 4. Ligation 5. Transformation 6. Cloning 7. PCR 3. Storage Conditions As soon as you receive the kit, open it and store Extraction spin columns at 2-8 C. mdi Micro Gel The remaining kit components can be stored at room temperature. The kit is stable for 1 year at given storage conditions. If precipitates appear in buffers re-dissolve at 37 C for few minutes. Page 3 of 16

4. Quality Assurance The mdi Micro Gel Extraction kit is designed for various pre-determined specifications and user requirements such as yield, purity, ruggedness, shelf life and functional convenience. These are produced through a well defined quality management system certified by Underwriters Laboratories, USA for ISO 9001: 2008 which ensures intra lot as well as lot to lot consistency. 5. Safety Information The buffers and the reagents may contain irritants, so wear lab coat, disposable gloves and protective goggles while working with themicro Gel Extraction kit. 6. Lot Release Criteria Each lot of Micro Gel Extraction kit is tested against predetermined specifications to ensure consistent product quality. Page 4 of 16

7. Technical Support At mdi, customers are our priority. We will share our experiences to assist you to overcome problems in general product usage as well as customize products for special applications. We will * Stimulate problems, and suggest alternative methods to solve them. * Make changes/ improvements in our existing products/protocols. * Develop special new products and system especially to satisfy your needs. We welcome your feedback to improve our products. 8. Kit Contents Spin Columns Contents Collection Tubes Buffer MMG Buffer GW Buffer GE Hand Book 50 100ml 60 15 Quantity 250 500ml 300 75 1000 50 250 1000 1 2000ml 1200 300 Storage Temperature 2-8 C Certificate of Quality 1 1 1 1 1 RT RT RT RT Page 5 of 16

9. Specifications Capacity of column reservoir 800µl Binding capacity of membrane (ds DNA) 5µg Recovery of DNA (70bp-4kb) 80% Maximum weight of gel slice 400mg Minimum elution volume for conc. DNA 10µl Total eluate volume 9µl Page 6 of 16

10. Principle The mdi Micro Gel Extraction kit allows isolation of high ultra pure DNA fragments from solublised agarose gel which involves: 1. Capturing of DNA from solublised gel slice on spin column 2. Washing 3. Elution 1. Capturing of DNA from solublised gel slice on spin column In order to facilitate adsorption of DNA fragment on to the spin column, suitable ph and salt concentration are required which is achieved by addition of binding buffer MMG. 2. Washing Subsequent to DNA binding from solubilised gel slice on spin column unwanted components like dyes, salts and agarose are washed away. Washing is done by buffer GW. 3. Elution Salt concentration and ph of elution buffer is important for elution efficiency, elution occurs at basic conditions and low salt concentration in small volumes. Elution is done with buffer GE. Page 7 of 16

11. Important Points to be Considered Optimization of Binding Buffers The binding buffers should posses appropriate salt concentration and ph to facilitate the efficient binding of single or double stranded DNA (70bp - 4kb) from solublized gel slice on spin column. Centrifugation * All centrifugation steps should be carried out at room temperature at > 10,000 rpm in a conventional table top microcentrifuge. In case of choking of spin column, increase centrifugation time and centrifugation speed to 12000rpm. Check the dissolution of the gel before addition to the column to avoid choking of the spin column Washing * To remove residual wash buffer spin the column for 1-2 minutes at >10,000 rpm. * Flow through should be properly discarded before additional centrifugation step otherwise it will not be removed & may inhibit enzymatic reactions. Elution * Elution buffer should be dispensed on to the center of column for maximum elution efficiency. If eluate volume is lower, then centrifuge for one minute extra at > 10,000 rpm. Yield DNA yield depends on following factors: 1. Volume of elution buffer 2. Amount of starting material Page 8 of 16

12. mdi Micro Gel Extraction Procedure Solubilized Gel Slice Bind Wash Dry Elute Ultra Pure DNA Fragment Page 9 of 16

13. Protocol 1. Excise the DNA fragment from the agarose gel with a clean, sharp scalpel or blade. (Minimize the size of the gel slice by removing extra agarose). 2. Weigh the gel slice in a colorless tube. Add 3 volumes of buffer MMG to 1 volume of gel. (100mg ~ 100µl) For example, add 300µl of buffer MMG to each 100mg of gel. 3. Incubate at 50 C in a water bath for 10 minutes (or untill the gel slice has completely dissolved). To help dissolve the gel, mix by vortexing the tube every 2-3 minutes, during incubation. 4. After the gel slice has dissolved completely, add 1 gel volume of Isopropanol to the sample and mix by inverting the tube. For example, if the agarose gel weight is 100 mg, add 100µl isopropanol. 5. Place the spin column in the collection tube in a suitable rack. To bind DNA, load the sample to the spin column and centrifuge for 1 minute at >10,000 rpm. The maximum volume of the column reservoir is 800µl. For sample volumes of more than 800µl, simply load, balance micro centrifuge and spin again. 6. Discard the flowthrough, and using the same collection tube, wash the spin column with 500µl of buffer MMG by centrifuging for 1 minute at >10,000 rpm. 7. Discard the flowthrough, and using the same collection tube, wash the spin column with 750µl of buffer GW by centrifuging for 1 minute at >10,000 rpm. 8. Discard the flowthrough, place the spin column in the same collection tube and centrifuge for 1-2 minutes at >10,000 rpm. Page 10 of 16

Important: This step is necessary to remove residual wash buffer. Residual wash buffer will not be completely removed unless the flow through is discarded before this additional centrifugation. Residual wash buffer may inhibit subsequent enzymatic reactions. 9. Place the spin column in a fresh 1.5ml microfuge tube (Not provided). Elute the DNA by dispensing 10µl of elution buffer GE directly on to the center of the column membrane, allow it to stand for 1 minute and centrifuge for 1 minute at >10,000 rpm. Note: The elution buffer should be dispensed on to the center of the column membrane for maximum recovery. The average eluate volume is 9µl from 10µl elution buffer. If the eluate volume is lower, then centrifuge for one minute extra at >10,000 rpm. Page 11 of 16

14. Trouble Shooting Guide A. Little or no Yield of DNA 1. Gel slice not solubilized Mix thoroughly with buffer MMG by completely vortexing the tube every 2-3minutes during 50 C incubation. Increase incubation time to 15 minutes. Preferably incubation should be done in a water bath instead of an oven. 2. Gel slice >400 mg Use multiple columns for gel slices > 400 mg. 3. ph of electrophoresis buffer too high Check the ph of electrophoresis buffer before use. In case it is > 8, prepare fresh buffer. The electrophoresis buffer, if incorrectly prepared or used repeatedly, results in sample ph that exceeds the buffering capacity of buffer MMG and leads to inefficient DNA binding. 4. Improper dispensing of elution buffer Elution buffer must be dispensed on to the center of the column membrane for maximum elution efficiency. 5. Insufficient incubation of elution buffer in the spin column Increase incubation time 2-3 minutes more. Page 12 of 16

B. DNA does not perform well 1. Eluate contaminated with Agarose The gel slice is not properly solubilized or is more than 400mg in weight. Vortex every 2-3 minutes during incubation time. Increase total incubation time. 2. Elution contains residual wash buffer Spin the column for 1-2 minutes extra at > 10,000 rpm to remove t h e r e s i d u a l w a s h b u f f e r completely. Page 13 of 16

15. Product Use Limitations mdi kits are developed and manufactured for research purpose only. The products are not recommended to be used for human, diagnostics or drug purposes for which these should be cleared by the concerned regulatory bodies in the country of use. Page 14 of 16

16. Product Warranty and Satisfaction Guarantee All mdi products are guaranteed and are backed by our a. Technical expertise and experience of over 30 years. b. Special mdi process for consistency and repeatability. c. Strict quality control and quality assurance regimen. d. Certificate of quality accompanied with each product. mdi provides an unconditional guarantee to replace the kit if it does not perform for any reasons other than misuse. However, the user needs to validate the performance of the kit for its specific use. Page 15 of 16

17. Ordering Information To order please specify as below: Type XX XX XX X Pack Size Type Code Pack Size Code MGEK MGEK 50 0050 250 0250 1000 1000 Example: MGEK XX XX XX X 0250 mdi Membrane Technologies UGLMGEKKIT1505A