TOC SYSTEMS INC. On-Line TOC Analyzer. Features -CHOICE OF PLATFORMS- Options. Combustion ON - LINE HIGH TEMPERATURE COMBUSTION

Similar documents
TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Process Total Organic Carbon Analyzer

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Fusion UV/Persulfate TOC Analyzer

1080 Total Organic Carbon Analyzer

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Torch Combustion TOC Analyzer

Fusion UV/Persulfate TOC Analyzer

QuickTOC condensate. Online TOC for steam and condensate circuits. Analysing hot samples accurately. Precise. Fast. Reliable.

ADI 7010 TOC Analyzer. Continuous monitoring of total organic carbon

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

QuickTOC condensate. Online TOC for steam and condensate circuits. Analysing hot samples accurately. Precise. Fast. Reliable.

7010 TOC Analyzer. Continuous monitoring of total organic carbon

Fpollutant-free zero air for analytical

BIOTECTOR SERIES 4 ON-LINE TOC ANALYZER

HACH BioTector 3500c ANALYZER FOR TOC, TC, TIC and VOC ANALYSIS

ONLINE TOC ANALYZER B-Series

BIOTECTOR TOC Analysers

RELIABILITY OF TOC RESULTS IN ULTRAPURE WATER ANALYSIS

Advanced Spectroscopic Solutions for Fuel Cell Hydrogen Analysis

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

BioTector System-C. Online TOC Analyzer for Clean Water Applications

Cl500/Cl1000 BROCHURE

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

APPLIED. OiW-100 Oil in Water Analyzer

Microbial Detection. Continuous At-Line Microbial Monitoring For Pharmaceutical Waters

ABSORPTION MEASURING INSTRUMENT

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

QbD1200 TOTAL ORGANIC CARBON ANALYZER RELIABLE MEASUREMENT MADE SIMPLE.

Analyzer Module Wet Chemiluminescence Detection (WCLD)

ACRP. Fact Sheets. On-Site Monitoring Methods AIRPORT COOPERATIVE RESEARCH PROGRAM. Sponsored by the Federal Aviation Administration

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Carbon. Carbon. Carbon parameters: Carbon

MAX300-BIO PRODUCT NOTE. Bioreactor/Fermentation Control Process Efficiency Product Quality Analysis. Bioreactor/Fermentation Mass Spectrometer

EQUIPMENT AND SERVICE COMPANY, INCORPORATED FX- 300 ISE Ammonia, Nitrate, Nitrite Measurement

6. TOC process analysis

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Drinking Water Monitoring. Ready-to-use systems for monitoring of quality relevant parameters in

A brief about online monitoring system. By Ajit Joshi & Amol Malode

HILASE - QUALITY CONTROL INSTRUMENT

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

Sievers M9 TOC Analyzers

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

Comparison Continuous Emission Monitoring Techniques

Monitoring Algae Growth in Marine Water Culture Solutions Using TOC/TN ACS - NERM - Dan Davis Shimadzu Scientific Instruments

On-Line Total Organic Carbon Analyzer TOC-4200 C391-E083B

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

EuroFID Total Hydrocarbon Analyzer

ON-LINE OIL TRACE MONITOR

Thermo Scientific Orion Versa Star Pro Benchtop Meters

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy

Triton TR8 Turbidity Analyzer

AUTOMATED ONLINE WATER QUALITY MONITORING. From ZAPS Technologies Product Brochure

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity

The LiquID Station AUTOMATED ONLINE WATER QUALITY MONITORING. From ZAPS Technologies, Inc Product Brochure

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Petroleum Fuels. ogen process analyzers 6000 SERIES

// XPLORER-NS. Total Nitrogen and Sulfur Analyzer

ScreenMaster RVG200 Paperless recorder

TOCII CA72TOC. Technical Information. Analyzer for online-determination of TOC in aqueous media using thermic catalytic combustion

Technical Information TOCII CA72TOC

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Proceedings of the 43 rd Annual ISA Analysis Division Symposium

Saltwater Analysis Using A High Temperature Total Organic Carbon (TOC) Analyzer with Static Pressure Concentration

QuickTOC ultra. Online TRUE TOC for every kind of water. Especially for the rough stuff. Fast. Precise. Reliable. TOC-ANALYSis

REVERSE OSMOSIS WATER TREATMENT

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

Del-Monox Breathing Air Purifiers DM Series

8 stream capability with dual mode (H 2 S & total Sulphur)

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

News. Power Generation 11. ph Control Reduces Acid Consumption in Neutralization Process up to 90 % Perspectives in Pure Water Analytics THORNTON

INVITATION FOR QUOTATION. ESE/2015/ Dated: 09/12/2015

GE Analytical Instruments (GEAI) Process TOC Applications

Sampling guide for determination of dissolved organic carbon and total dissolved nitrogen in seawater

Turbidity and Suspended Solids

Heated FID OVF Portable THC/TVOC Analyzer

TVOC Heated FID VE 7

ABB MEASUREMENT & ANALYTICS. AlSCAN and AlSCAN Argon Hydrogen analysis in liquid aluminum

Model Product Description and Specifications

Royce Parts Per Million Dissolved Oxygen Systems. Water & Wastewater

GAS DETECTION SYSTEMS

TURBIDITY WATER QUALITY

Product catalogue LAR Process Analysers AG

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

Online Gas Analyzer / Monitor

MRU FOR PROFESSIONAL MEASUREMENTS

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

NPOC, VOC, TC-IC and TDN using Shimadzu TOC-V Protocols. Water Quality Analysis Laboratory at the University of New Hampshire

GAS CHROMATOGRAPH FOR MULTIPLE IMPURITIES

Transcription:

TOC SYSTEMS INC StarTOC TM Combustion On-Line TOC Analyzer Features ON - LINE HIGH TEMPERATURE COMBUSTION TOC-True NPOC or Microsoft Windows Touch Screen Computer Digital Injection 2 Alarm Levels 1 Master Fault Alarm 4-20 ma Outputs RS-232C Output Separate Electronics & Liquid Compartments -CHOICE OF PLATFORMS- Powder Coated Steel Options Stainless Steel Enclosure Dual NDIR Analyzers Correlated BOD/COD Benchmark/Auto Validation Auto-Cal/Auto-Clean Automatic Multi-Range Multi-Stream Analysis Microprocessor Interactive Menus Description Windows CE Computer with Touch Screen Control Touch Screen VGA Color Network Ready Paperless Chart Recorder PCMCIA Slot Solid State Data Storage TOC Systems, Inc. uniquely offers all methods of TOC analysis* and recommends High Temperature Combustion as the method of choice for certain applications. Only the StarTOC analyzers offer the features and reliability of operation associated with its team s pioneering experience in TOC analysis since 1969**. RS-485 output Network Ready Because we offer a full line of High Temperature Combustion, UV/Heated Persulfate, Ozone Promoted and Ultra-Pure TOC Analyzers, we are able to offer you objective, unbiased advice and can therefore fully commit our total resources to providing you the best possible installation. 12508

Network Enabled Utilization of an onboard Windows CE computer allows direct networking. Central control of analyzer operation and data management are easily facilitated. Preferred Applications Excellent TOC accuracy from parts-per-billion to moderate concentration levels of salt-free samples, with minimum maintenance. Standard Method 5310 C/D EPA 415.1 EPA 9060 ASTM D 4839-88 ASTM D 4779-88 Wastewater Heavy Particulated Liquids Difficult to Oxidize Samples Process Streams Oil in Water Regulatory Compliance Guaranteed * Visit our website to view our entire family of TOC analyzers. (2) The Pitfalls of Process TOC Analysis and How to Avoid Them (1999 Instrument Society of America Tutorial)

Air/O 2 TIC(CO 2 Over-flow Sample Acid Sparger MFC Reactor NPOC Printer output Communications Contact NDIR-1 Data Processing Display/ Paperless Chart. Recorder Touch Screen NPOC Analysis NPOC (Non-Purgeable Organic Carbon) mode is preferred for accuracy when no volatile organics are in the sample. The Digital Injector delivers the sample to the sparger, where it is mixed with acid to lower its ph to approximately 2.0. At this ph, the inorganic carbon in the sample is converted to dissolved CO 2 and is stripped (sparged) from the sample by air/o 2 and vented to atmosphere, along with any purgeable/ volatile organics. The carbonatefree sample is drawn from the sparger by the Digital Injector and delivered to the Reactor, where the remaining NPOC is oxidized to CO 2, which is measured by the NDIR (Non-Dispersive Infrared Analyzer) as a direct correlation of NPOC in the sample. NPOC is often erroneously reported as TOC. Air/O 2 Over-flow Sample Acid Sparger MFC TIC TC Reactor all species of organic carbon are measured, not just the NPOC. Benchmark/Auto-Validation NDIR-2 NDIR-1 TOC-TRUE TOC-True Analysis TOC-True mode is the preferred method of use if any volatile hydrocarbons are present in the sample, which would be lost in the Inorganic Carbon removal sparging stage in an NPOC analysis. The TOC-True method measures both TC (Total Carbon) and TIC (Total Inorganic Carbon) for a more accurate and complete analysis of the total organics in the sample, including the purgeable/volatile organic carbon. By subtracting the TIC from the Total Carbon in the sample, Benchmark (2) is the validation technique, whereby on command a chemical calibration standard is automatically introduced to the analyzer and the response is compared to the previous analyzer calibration. If the response falls within a certain specified limit, the computer/output indicates Benchmark Passed. If the response falls outside specified performance limits, either a Maintenance Request or a Fault alarm is activated, depending on preset tolerances. Thus, in cases of process spills, when the analyzer performance is questioned, Benchmark can rapidly and automatically validate analyzer performance. It eliminates time consuming and unnecessary recalibration cycles, which take the analyzer out of service just when it is most critically needed. Benchmark may be on-demand, or operator programmed for designated day and time activation on a repetitive basis. Auto-Cal and Auto-Clean utilities are also available. Printer Output Communications Contact Data Processing Display/ Paperless Chart. Recorder Touch Screen

NDIR (The key component for reliable TOC analysis.) IR Detectors Sample Cell IR Source Specific, Interference-Free CO 2 Detection Dual-Wavelength Ratioing Compensates for Drift Computer-Controlled for Accuracy Sapphire Protected Optics Non Corrosive, Non-Reflective Sample Cell (Borosilicate) No Moving Parts or tools required for Easy Maintenance and Service No Critical Realignment Required Detection Technique The NDIR CO 2 detector uses a solid-state, dual-wavelength system with a single borosilicate glass sample cell that requires no wall reflectivity. There is a reference and a CO 2 specific detector in the sample path. Use of the true zero filter eliminates water vapor interference and the requirement for chemically removing acid gases prior to detection. An infrared source is cycled on and off to avoid mechanical choppers required in alternate NDIRs. The StarTOC NDIR has no moving parts. Automatic gain control (AGC) is employed during the reference/sample cycle to compensate for such factors as NDIR source deterioration, dirty optical windows, and detector gain changes. When the AGC level reaches a predetermined threshold, the output alerts the Operator to check the NDIR. Malfunctions of major NDIR components are detected as an alarm, providing fail-safe operation. Signal detection is completely synchronous and, because of the differential technique of ratioing the Zero and CO 2 outputs, zero drift is virtually eliminated. All critical optics are protected by sapphire windows. The sample cell can be easily removed and the windows cleaned within 15 minutes, without realignment or the use of any tools. This absolute measuring, dual-line spectra comparison NDIR provides simple, direct measurement of all CO 2 contributing factors (including background) for a true and accurate calibration and precisely offsets these effects for very accurate TOC determinations. The consequences of water vapor interferences in lowlevel precision TOC analysis are avoided.

POWDER COATED STEEL ENCLOSURE High Temperature Combustion Module Control Module Stainless Steel (option) Specifications Nominal at 25 C. Subject to custom application requirements. Measuring Range (Std.) 0-100 ppm through 0-20,000 ppm without dilutio n R e p e a t a b i l i t y +/- 2% of Full Scale D r i f t Compensated, self-calibrated NDIR (+/- 2% non-accumulative) Response Time T9 0 Analog Outputs Relay Outputs Computer/Display From 6 minutes, depending on range 4-20 ma (1 each per Stream ) 2 TOC adjustable level alarms 1 master fault alarm Microsoft Windows CE Touch Screen Computer: Color VGA Display, Solid-State Data Storage, Paperless Chart Recorder, PCMCIA Slot, Network-Ready & Optional RS-485 Or Modbus Power Supply 110/220 VAC 10 Amp service recommende d Enclosure Dimensions (HxWxD) W e i g h t Powder Coated Steel or Stainless Steel 61x81x41 (cm) 24x32x16 (in) 34 Kg. 75 Lbs. The analysis range and precision are affected by sample introduction, chemical standards preparations, gas purity and operator skill. sample homogeneity, sample container cleanliness, reagent purity,

Installation Requirements The StarTOC TM On-Line High Temperature Combustion model can handle suspended solids up to 1,000 microns without filtration, thus providing a truly representative sample. TOC Systems, Inc. furnishes recommended installation drawings. The user must provide the following: 1. Electrical Source (110/220 VAC 10 Amp service with cutoff switch) 2. Sample flow of a minimum of 10 ml / minute. A fast bypass loop is recommended. 3. Gravity fed drain with air break. 4. A source of CO 2 -free air, or oxygen with a maximum flow rate of 300 cc/minute at 15 psig. (Optional Star Oxygen Generator requires electricity only.) Purchase Specifications The Analyzer shall use the EPA, ASTM and Standard Approved Methods for TOC analysis. It shall utilize the High Temperature Combustion method capable of either catalytic or non-catalytic oxidation. An onboard Windows CE Computer shall be used to control all analyzer functions automatically and be configured with a touch screen, paperless chart recorder and be network-ready. It shall store time/date stamped historical data records up to one (1) year. CO 2 detection shall be by a solid-state, single path length non-dispersive infrared analyzer (NDIR), having no moving parts. It shall be self-calibrated and interference-free. A computer controlled Mass Flow Controller shall be used to provide maximum analytic stability and reliability of results. The Analyzer shall be housed in a ( specify: epoxy powder coated painted steel, or FRP, or stainless) enclosure to avoid corrosion and have separate compartments for liquid handling and electrical systems. The Analyzer shall be a TOC Systems, Inc. Star TOC High Temperature Combustion Analyzer, suitable for the on-line designated application. Ordering Information Description Specify Configuration Microsoft Windows-CE Computer based, Single Stream Analyzer, Benchmark, Auto-Calibrate, Auto-Clean, Paperless Chart Display, Historical Records Digitally Stored Up to One Year TOC Configuration TOC Configuration TC Configuration Multi-Stream Sequencer to Multiplex Up to 4 Streams, Std. (Requires Microsoft Windows Computer) NPOC TOC-TRUE TC 2-Stream Sequencer with indpendent 4-20 ma 3-Stream Sequencer with indpendent 4-20 ma 4-Stream Sequencer with indpendent 4-20 ma ( 1) Microsoft is a Registered Trade Mark of Microsoft Corporatio n

We also Offer Complete, Turn-Key, Analyzer & Sample Systems Pre-engineered and custom packages, including small shelters with all utilities installed and ready to be delivered to your site. Effluent Monitoring Waste Treatment Drinking Water Process Monitoring Panels & Small Shelters Custom Packages TOC BODc CODc Total Nitrogen Phosphorus Alkalinity Turbidity ph Probes & Transmitters Sample Systems

SAMPLE SYSTEMS BASF PROJECT CENTER FOR DISEASE CONTROL PROJECT

CORRELATED PROCESS COD/BOD (option available for all StarTOC on-line models) Benefits Excellent Correlation (Requires initial correlation of Lab analysis with grab samples ). Procedure Collect representative grab samples from analyzer & press Save TOC button. Send grab samples to lab for BOD or COD analysis. After receipt of lab analysis, enter BOD or COD analysis values as prompted by the Microsoft Windows CE Computer. This automatically correlates in time with the TOC measurement previously taken. Thereafter organic values are displayed in units of choice (BODc, CODc or TOC).

StarTOC Family of TOC Analyzers (Partial). FOR THE LAB / BENCHTOP Automatic Semi-Automatic Solids, Slurries, Liquids FOR THE ON - LINE / PROCESS UV/ Persulfate Ozone / Total HC Combustion Ultra-Pure Hydroxyl Radical Oil-in-Water TOC/TN TOC Systems, Inc. 100 Park Avenue League City, TX 77573 USA Phone (281) 338-1388 Fax (281)332-5609 email: sales@tocsystemsinc.com