Donna Newman B.A. RT ( R) CNMT Director of Professional Practice ISRRT

Similar documents
Radiation Protection in Fluoroscopy

Radiation protection for theatre staff (refer guidelines) DISTANCE, TIME, SHIELDING principle should be applied

HARMONIZATION OF RADIATION SAFETY. Emerging challenges in the management of medical exposures Views from PAHO, WHO, EC, IAEA

New Joint Commission Requirements for Fluoroscopy Services

Types of Radiation Units

Improving Optimization in Occupational Radiation Protection in Medicine

FLUOROSCOPIC PATIENT & OPERATOR RISK REDUCTION

There are three general methods for reducing one's personal radiation exposure. The application of each when working around fluoroscopy units will be

How to Optimize Radiation Protection During Complex Peripheral

Fluoroscopic Radiation Safety

Radiation protection in the cath lab and interventional radiology: practical hints and tricks

What s the Issue? Radiation Dose in the OR. Exposure to OR Personnel. Effects of Proper Collimation. Image-guided procedures are increasingly complex

FLUOROSCOPIC SAFETY AND PATIENT AND OPERATOR RADIATION DOSE REDUCTION: CREATING A FOCUSED FLUOROSCOPIC CURRICULUM FOR RADIOLOGY RESIDENTS

Improving protocols and procedures for strengthened radiation protection in interventional procedures

Fluoroscopy Credentialing Training Program for Non-Radiologist Physicians. Department of Radiology

Radiation Exposure During Endovascular Procedures: Methods to Protect Patients, Physicians and OR Personnel

Minnesota Rules, Chapter 4732 X-ray Revision

1. Executive Summary

2017 ACR Computed Tomography Quality Control Manual FAQS

Interventional Fluoroscopy

Justification for Training

Instructions. Print out all three tabs of the guide to be used as a reference.

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Table of Contents. 1. Introduction. 2. Authorisation Process. 3. X-Ray Facility Design Considerations and Minimum Requirements. 3.

CALIFORNIA LAW AND RESPONSE + FIVE QUICK LESSONS ON CT DOSE OPTIMIZATION

Fluoroscopy units come in many different physical configurations but all consist of the main components shown in this slide.

Study of the Spatial Distribution of Scattered Radiation Dose Around a Surgical C-arm. Assessment of Radiation Exposure to Staff.

Radiation Physics and Safety Considerations in the EP Lab

The University of Texas Health Science Center at San Antonio Environmental Health & Safety Department Radiation Safety Division

AN ABSTRACT OF THE THESIS OF

Radiation Dose Index Monitoring (RDIM)

Introduction. FDA Approval. Breast Tomosynthesis From the Ground Up

Equipment Quality Control for Fluoroscopy February 22, Imaging Physics CancerCare Manitoba

Federal Authority for Nuclear Regulation UAE

The following 2 points present a particular concern for us:

Computed Tomography: Optimization of acquisition protocols & Justification of clinical referrals. Koos Geleijns, medical physicist

Radiation Safety Guide for Diagnostic Imaging. X-Ray Producing Equipment

Part 3 Oral Exam Content Guide

Compliance Guidance for FLUOROSCOPIC QUALITY CONTROL 2 nd Edition

مباحث :IAEA Training Material on Radiation Protection in Cardiology. List of Topics & Objectives١.doc

Radiography Curriculum Analysis

2 / 1. SUMMARY public, should be well documented, and should be reviewed on a regular basis to determine whether it continues to meet the operational

Function of this control

Implications of the implementation of the revised dose limit to the lens of the eye: the view of IRPA professionals

Dose management at Ziehm Imaging for 2D imaging

Robert Boyle Prof of Medical Physics Trinity College, g, Dublin IAEA, Vienna

4p All 2017 JUN 27 AN 11:29. Medical reportable event for radiation-producing diagnostic or. interventional X-ray procedures -

Healthcare. Philips DoseWise Portal. Radiation exposure management software

1. Executive Summary

Radiation Dose Terms Made Simple v1

DoseWise Portal. Take control of dose management. across your organization

THESIS OCCUPATIONAL RADIATION DOSE DURING THE TRANS-CATHETER AORTIC VALVE REPLACEMENT PROCEDURE. Submitted by. Omar Hani Shatila

Journal of Theoretical and Applied Information Technology.

Implications of the Implementation of the Revised Dose Limit to the Lens of the Eye: The view of the IRPA professionals

Take control of dose management

DEPARTMENT OF ENVIRONMENT, HEALTH & SAFETY RADIATION SAFETY DIVISION. University of California, Los Angeles RADIATION SAFETY GUIDANCE

RADIATION SAFETY Analytical X-Ray Systems Indiana University - Bloomington

Quality Assurance for particle beam therapy

Rajvir Singh; Scientific Officer H BSCS, BARC ;

Ethics of Radiation Protection in Medicine

Optimisation of Clinical Protocols

RADIATION DOSE MONITOR. The DACS for Building a Low-Dose Culture

A dosimetric trial for the clinical follow-up of potential skin injuries on patients undergoing interventional cardiology procedures

2018/7/31. Primary Objective

RADIATION DOSE MONITOR

New PET/CT from Siemens helps more patients benefit from premium technologies

Radioactive Material User Annual Refresher Training. Created by SU Environmental Health & Safety Services

Ceiling Mount, Floor Mount & Biplane. Hybrid Lab. *The system pictured is the INFX-8000C

SEMINAR 1. Radiological Protection Of Patients. Radiation Protection in Paediatric Cardiology. Dra. Patricia Miranda González

This is probably the kind of radiotherapy that you are used to delivering in your country.

SPECIFICATION CT SIMULATOR FOR BLACK LION HOSPITAL, ADDIS ABEBA, ETHIOPIA

UCSF MEDICAL CENTER JOB DESCRIPTION

Patient doses from CT examinations in region of Prishtina, Kosovo

2/14/2017. Introduction & Objectives. Radiation Safety Program Structure. Massachusetts DPH Radiation Control Program

More flexibility More performance Less dose

Joint Commission Medical Imaging Requirements. Laura Gruber, MBA, RT(R), RDMS, RVT Sr. Director Department of Medical Imaging SPR Annual Meeting

Imaging Systems. Gene Saragnese CEO Imaging Systems

Eric W. Abelquist, Ph.D., CHP President, Health Physics Society. August 2017

Reducing Unnecessary Medical Imaging Exposure

IMAGE GUIDANCE DOSES IN RADIOTHERAPY. Scott Crowe

Third WHO Global Forum on Medical Devices Geneva May 2017

The role of Diagnostic Reference Levels in Optimization

Data Mining to Aid Beam Angle Selection for IMRT

SPECIFICATION. SPECT/CT Gamma Camera System

The use of personal protective equipment in nuclear medicine

SPECIFICATION DIGITAL MAMMOGRAPHY UNIT AND ASSOCIATED SERVICES

Evaluation of the shielding efficiency and space dose of the tungsten shielding system

APPENDIX B INSTRUCTIONS AND SAMPLE APPLICATION FORMS FOR AUTHORIZATION

APPLICATION FOR AN X-RAY SAFETY CERTIFICATE

CQIE PET PROCEDURES. American College of Radiology Clinical Research Center. Centers for Quantitative Imaging Excellence LEARNING MODULE

Patient Dose Research in Interventional Radiology Suites in Rio de Janeiro, Brazil

X-ray Equipment Safety Orientation. May 4, 2018

Table of Contents. Adaptive Diagnostics...7 Integrated Dose Reduction Streamlined Workflow Clinical Images... 26

On the Importance of Computation in Clinical Radiology

Past Experience and Future Plan in Korea

Integrated Research Application System (IRAS) Question-specific guidance Part B Section 3. Exposure to ionising radiation

Dose Reduction during EVAR in Hybrid Room. Multicentric Study

Not for publication in the USA Erlangen, November 26, 2017

The Consistent Quality of Connected Radiology

White Paper. Dose Tracking System. Patient Skin Dose Estimates in Real Time

Transcription:

Donna Newman B.A. RT ( R) CNMT Director of Professional Practice ISRRT

Responsibilities Worker (BSS 3.83) Workers shall: follow any applicable rules for protection use properly the monitoring devices and the protective equipment and clothing provided co-operate with the licensee with respect to protection Factors affecting technologist exposure( Occupational Dose Exposure) How use x-ray system Whether protective measures used Optimization of patient dose Number of procedure performed Height of technologist New Multi Modality( Hybrid Imaging ) PET/CT, SPECT/CT, PET/MRI IAEA-13.1: Occupational exposure - Regulatory aspec

Occupational Radiation protection is a shared responsibility: Imaging Team( Radiologist, Medical Physicist, Radiologic Technologist ) What is the Technologist Role? ICRP 2008 Recommendations Justification, Dose Limitations,Optimization of protection Optimize Operating parameter of you Imaging System Quality Assurance Program and Quality Control Program Use recommended International guidelines that are available to assist in optimization of image quality and radiation dose Become familiar with Professional Organization s and website s that are internationally accepted for best practice for dose reduction Ensure Qualifications of Staff Initial and yearly Competency check list Radiation Protection guidelines in line with new scientific knowledge ( Hybrid Imaging- PET/CT, PET/MRI, SPECT/CT) ALARA=Time,Distance and Shield

Technologist Protection: By Modality Diagnostic Radiology Control Booth,Exposure button /connected to a cord, Lead glass, X-ray tube always pointing to the receptor/ SFOV for beam collimation Portable machine- 6 ft cord, lead apron ( 6 Ft and at 90 degree angle) Properly position patient reduce non targeted tissue and use tight collimation Effective Immobilization strategies young patients( age 5 under) more effective then manual physical restraints by staff, to avoid motion Shielding- Eye protection, Face protection, Thyroid protection, Hand protection

Technologist Protection: By Modality Nuclear Medicine/PET Protective clothing/use Syringe Shields, lab coat and gloves, absorbent pad Contamination monitor Shields-Bench top shield,vial shields,syringe shield forceps, tongs CT Adjust CT doses to patient size, Beam Ma Modulation Automatic dose reduction methods in CT scanners with optimal x-ray tube voltage Standardize CT protocols; periodic review Ct Collimation to reduce scatter Pitch Develop CT QC programs Special consideration for I-131 Therapy Post processing and real time noise reduction algorithms for DR, CT and Fluoro

3 Principles of Radiation Protection: Time, Distance and Shielding Applications Fluoro and C-arm ( Diagnostic, Interventional, OR Minimize Fluoro Time: last hold, tap instead of continuous Position patient /as far from x-ray tube tight collimation Protocol s with x-ray tube opposite the operator Personal protective gear/ lead apron, Thyroid shield, lead eye wear Equipment shielding/ Ceiling shields, table shield, patient shielded tarps, Wear personal Dosimeter/ Use lowest Dose possible

Lessons Learned : Radiation associated Cataracts Two separate studies in 2010 Studied Cataracts in Interventional procedure and concluded: Without proper eye protection health care professionals were at higher risk of developing cataract 2011(ICRP) Based this data 2011 the international commission on Radiological protection (ICRP) reduced the lens threshold value of absorbed dose for cataract form 3.0 Gy to.50 Gy Radiation cataract risk in interventional cardiology personnel, radiation Res.,Vano e. 2010:174(4):490-495 Risk for radiation induced cataract for staff in interventional cardiology: Is there a reason for concern?, Ciraj-Bjelac O, Catheter Cardiovasc Interv. 2010:76(6):826-834

Conclusion: Team approach(radiologist, Physicist and Technologist) Better QA and QC standardization needed in all countries Close the gap the exist in radiation protection programs world wide Ensure that all workers have access to radiation protection devices ( aprons, thyroid shield, lead eye wear) Non- traditional educational material available on the newest hybrid equipment ( PET/CT, PET/MRI, SPECT/CT ect. ) best practice information