Metering Simplified Ultrasonic Technology

Similar documents
New Electronic Billing Meter Standards Shocking Utilities & Customers

C Addressing Non-Revenue Water with Static Meters. Martin Casillas Director of Sales, US West Kamstrup

Gwinnett County, Georgia Improves Meter Program Through Science and Strategy

Commercial & Industrial Large Water Meters

Impact of Large Meter Sizing on Unaccounted For Water. Presented by:

Water Challenges WORKING TOGETHER TOWARDS SOLUTIONS California-Nevada AWWA Annual Fall Conference Large Meter Testing: Analysis and Calibration

Why Water Meters Matter The New York City Department of Environmental Protection s Operational Excellence Program (OpX)

Addressing Non-Revenue Water

Smarter Water Management

Clamp on Ultrasonic Flow Measurement Principal Transit Time Doppler What Distinguishes Flexim Technology

SPECIFICATION. Category: Cold Water Meter Type: Ultrasonic Transit-Time Size: 2 12 Applicable AWWA Standard: C750. Version 2.18

WHITE PAPER A New Approach to Accurate Water Flow Measurement - The Study of the FPI Mag Accuracy

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE

"Effective Water Resource Management using Modern Metering Technology and Systems." 3 April 2013

Choosing the Right Residential Water Metering Technology

Removing the Barriers to Efficient Water Leakage Management

NOTICE OF DISCONTINUATION,

Everett Water Department Rules. & Regulations. Notification Page 2. Public Water Mains Page 2. Private Water Mains Page 2. Water Conservation Page 3

OTCO 12/11/13 Water Audits Meter Testing & Leaks

Utility Funds. Department of Public Works Utilities. Fiscal Year 2017

WRF Webcast Case Studies to Identify Occurrence, Accuracy, and Causative Factors of Reverse Flow as Measured by Meters

North American Water Loss Conference 2017

METERS AMR/AMI CONTROL. Integrated Metering Technologies

Glossary Irrigation Terminology

Driving Operational Efficiency and Reducing Water Loss

Water Efficiency for Small Businesses

Water flow measurement in the oil and gas industry

Understanding Water Loss. Addressing Authorized /Unbilled Consumption and Apparent Water Loss

Water metering systems solutions

Smart Distribution System Applications

An Innovative Approach to DMA. October 2015

Testing Finished Water Meters A Low Tech Approach

EXHIBIT B. Notice of Non-Compliance

ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS. All rights reserved to thepetrostreet.com

ASM320. Distribution. Distribution

Water Audit and Water Loss Abatement Program

Case Studies to Identify Occurrence, Accuracy and Causes of Reverse Flow Using Meter Systems

We need to regulate the temperature and humidity of homes and buildings for comfortable living.

Water Conservation: Strategies, Pricing, Revenues

Fundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX

We are here only to share our experiences. No recommendations

Measuring Gravity Sewer Flow Accurately

Cross Connection Control Rules

Flow Measurement Structure Assessment

Biotube EasyPak Design Criteria

Monitoring and Data Collection

ORDINANCE NO NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF GARLAND, TEXAS: SECTION 1

System Flushing & It s Hazards

Less Loss is our Gain Water Loss Control in Los Angeles

Smart Water Infrastructure Solutions Overview. Craig Collins January 8, 2015

Streamflow Measurement

Backflow explained About backflow prevention containment. Backflow explained. About backflow prevention containment. Page 1

Guidelines for Design of Potable Water Distribution Facilities In New Developments

1. The sign in sheet from the Pre-Bid Meeting on February 13, 2018 at 1:00 P.M. is attached.

Americas Competitiveness Exchange on Innovation and Entrepreneurship Ontario s Water Sector

The Silent Thief Large Meter Accuracy Degradation Findings & Impacts

Ultrasonic Flow Meter Solutions. Time-saving Installation. Easy Flow Measurement.

66% 14% SOLUTION NEED. THE WE ARE AMERICAN WATER $5.5 BILLION IN 5 YEARS

First ask the question: What is mine water management and why do we care?

Reduction of Apparent Losses Using the UFR (Unmeasured-Flow Reducer) Case Studies

ONTARIO CENTRE FOR MUNICIPAL BEST PRACTICES 200 University Ave., Suite 801, Toronto, Ontario, M5H 3C6. BEST PRACTICE SUMMARY REPORT February, 2008

TAKING CLOSED PIPING FLOWMETERS TO THE NEXT LEVEL NEW TECHNOLOGIES SUPPORT TRENDS IN DATA LOGGING AND SCADA SYSTEMS

Data Integration Solutions for Effective Utility Management Progression towards Smart City Implementation

Smart Metering IS Metering Smart First

CALDON LEFM 380Ci Gas Ultrasonic Flowmeter

API Review. Copyright 2007, FMC Technologies Measurement Solutions, Inc. PR0A028I Issue/Rev. 0.0 (7/07) - Slide 1

Flow Measurement for Structure Assessment in Richmond Irrigation District

WATER DEPARTMENT POLICY Table of Contents

Discharge Measurement in Small Hydropower Stations using Acoustic Doppler Current Profiler

LNG workshop. Flow Metering. Peter Lucas and Nikola Pelevic

Advanced Metering Infrastructure (AMI) Pilot Studies Update

WATER SYSTEMS OPERATION AND MAINTENANCE VIDEO TRAINING SERIES COURSE OUTLINE

WATER CONSERVATION PLAN TOWNSHIP OF PENNSVILLE

Water Efficiency. Water Plant Operator. Association of Manitoba Municipalities Web:

Meeting the Water Efficiency Challenge

WATER LOSS CONTROL PROGRAMS

Water Conservation Partnering to Save Water Essex County Environmental Commission Verona, NJ. April 4, 2016

measurement sensor and data transmission technology innovation has reduced installation costs, simplified maintenance and enhanced plant performance

GUIDE TO WATER SERVICE APPLICATIONS

NOTICE OF PUBLIC HEARING WATER BUREAU OF THE METROPOLITAN DISTRICT PROPOSED 2019 WATER RATES AND REVISIONS TO WATER ORDINANCES

Backflow Irrigation Control Station

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

November 7, 2018 NOTICE OF PUBLIC HEARING WATER BUREAU OF THE METROPOLITAN DISTRICT PROPOSED 2019 WATER RATES AND REVISIONS TO WATER ORDINANCES

Large Meter Condition Assessment Using AMI Data City of Toronto. Carlo Casale Jeff Coulson Claude Williams

Controlling water flow speed and volume by using a Flow Management Valve control node at meter egress connection point.

Distribution System Basics Course Syllabus

WHERE INTELLIGENCE MEETS INFRASTRUCTURE. Intelligence that drives the network.

Municipal Water Experts Celebrated our 50 th Anniversary National Service Capability Part of a Global Group of Suez Companies Focused on Asset

LEASE AUTOMATIC CUSTODY TRANSFER UNITS (LACT UNITS)

PLUMBING SYSTEMS. Plumbing Systems

Why Smart Water Networks Boost Efficiency

Illinois Water Audit and Loss Control Training Workshop

Water Loss. Water Research Foundation How to use the Free Water Loss Audit Software v 5.0

Smart Water Management : Its application and case. May 30 th, 2017

PURCHASING SECTION Avenue, Surrey BC V3T 1V8 Tel: ADDENDUM #2

Implementation of Magnetic Meters for Irrigation Volumetric Measurement. Stuart W. Styles 1 and Lynn Groundwater 2

An innovative approach NRW

A M E M B E R O F T H E K E N D A L L G R O U P

Backflow prevention. Information for plumbers

Transcription:

Metering Simplified Ultrasonic Technology Mike Phillips- Master Meter, Inc. Brandon Begley- Fortiline Waterworks

Complicated Choice Match Game Propeller Multi-jet Mag Floating Ball Turbine Fire-Service Turbine Compound Single-jet Fire-Service Assembly Ultrasonic Positive Displacement

Legacy Products (still in use) Turbine / Propeller (introduced in the late 1700s)

Legacy Products (still in use) Compounds (introduced in 1914) Mainline turbine Low flow meter (Multi-jet or PD) Automatic valve for diverting flow rates Dual or single registers Master Meter DBC (Dual Body Compound)

Legacy Products (still in use) Fire Assembly Meters (introduced in 1908) Mainline meter (turbine or proportional type) Low flow meter (MJ, PD, turbine or compound) Automatic valve for diverting flow rates Master Meter FSC (Fire Service Compound)

Why it is important Unmetered consumption Inaccurate meters Damaged meters Frequent repairs All lead to lost revenue The 80/20 Rule Generally 20 % of a utilities total installed meter base measures 80% of the total billable volume 20% = Commercial and Industrial meters

How Ultrasonic Works Ultrasonic Technology Basic Operating Principle is Sound Two types Doppler-Effect Best suited for wastewater and slurries

How Ultrasonic Works Ultrasonic Technology Basic Operating Principle is Sound Two types: Transit Time (the Octave) Best suited for clean water. Sound waves are generated by a transmitter and are either reflected to, or sent across the pipe to a receiver. This same process happens in the opposite direction. (one with flow, one against flow). Upstream and downstream times are compared. The difference in time equates to the water velocity. No time difference = no flow

How Ultrasonic Works Transducers (4 total) Sonic Ports (4 total)

Measuring Principle Dual Beam Ultrasonic Transit Time Sing Around

Ultrasonic vs. Turbine 3 TURBINE 3 GPM Average Low Flow @ -5% - +1%. 5 GPM Normal Range @ + 1.5% 0.5-0.7 GPM Average Flow The 80/20 Rule Toilets ( 92): Up to 1.6 USG per flush Urinals ( 92): Up to 0.5 USG per flush

Ultrasonic vs. Turbine

Ultrasonic vs. Turbine Turbine Ultrasonic

Keep it Simple ELIMINATE: Installing the wrong meter type Excessive maintenance costs Gradual decrease in accuracy High overhead & inventory costs Decrease installation costs

Simplified Installation VS. Turbines up to 80% heavier Compounds up to 300% heavier Fire Assemblies up to 1800% heavier

Simplified Meter Selection Ultrasonic is Migrateable The Octave fits most meter installation services

Ultrasonic Meters Simplified Inventory The Octave eliminates the requirement to stock multiple meter types

Features & Benefits Ultrasonic Technology Overview No moving parts Sustained meter accuracy No strainer required Low flows similar to compounds and high flows similar to turbines FM Approval - one meter for all applications Reduced headloss Light-weight design No cross-over drop in accuracy

Improving Water System Operations AMI (Advanced Metering Infrastructure) Meter selection and accuracy Non Revenue Water Evaluation (DMA) System Leak Monitoring System Backflow Water Quality Monitoring

Smart Grid AMI refers to the full measurement, collection and processing of meter and other customer data AMI includes smart meters installed at each premise, a two way communications network, and data management systems AMI enables more granular measurement of consumption, the matching of consumption to price and more frequent transmittal of consumption data AMI enables a partnership between Utilities and their customers to help customers make better energy decisions

GIS Layered Mapping GIS / Layered Maping Fire Hydrants Water Valves Integrated, multiple GIS layers for Infrastructure presentment

Customer Engagement SMS Leak Budget ALERTS

Final Considerations Final Considerations o How will you use this massive amount of data to reach your goals? o Customer segmentation? o Creating value? o Which insights are you after? o What metrics are most helpful in your day-to-day operations? o How do you currently track Service Reliability? o Index customer satisfaction?

Thank You Mike Phillips- Master Meter Brandon Begley- Fortiline Waterworks