ACOUSTIC SUPPLIES. For Acoustic Solutions you can SHOUT about

Similar documents
ACOUSTIC SUPPLIES. For Acoustic Solutions you can SHOUT about

Acoustic Cradle Levelling System

June Non - Residential Refurbishment Separating floors

June Residential Refurbishment Separating floors

April Section 4.3. Separating Floors

Specialist products. Proven expertise. Acoustic flooring systems to meet the 2010 Scottish Standards - Section 5

The Sound Choice for all Acoustic Insulation Projects

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Dwelling-houses and flats performance standards for separating walls, separating floors and stairs that have a separating function.

ROCKFLOOR. Thermal and acoustic stone wool insulation for ground and separating floors

Please Note: PhoneStar was previously branded as Phonewell

September Reflex Bearers

ACOUSTIC SYSTEMS PROFLOOR. effective solutions for impact and airborne noise INNOVATION BUILT ON EXPERIENCE

Suspended timber upper floors

FERMACELL DRY FLOORING ELEMENTS: IMPROVED LIVING CONDITIONS THROUGH BETTER ACOUSTIC AND THERMAL INSULATION. Dry Lining

SubPrimo. subprimo. Acoustic insulation for timber & laminate flooring. Uniclass L5395:N372 EPIC E485:Y45. CI/SfB (43) T (P2)

SIDERISE CBX flexible acoustic barriers for suspended ceilings

Specialists in Acoustic Flooring and House to Flat Conversions

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

ROCKWOOL FLEXI Insulation Application Guide

Part E robustdetails. robustdetails. September 2015 Update Pack. Dear Colleague,

Selecting floors and ceilings

URSA ACOUSTIC ROLL URSA GLASSWOOL.

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

Cement Particle Board

June Non - Residential New Build Partition walls

Part E robustdetails. robustdetails. January 2018 Update Pack

CI/SfB l l l Ym1 l (M2) l July Superior 4 in 1 insulation TIMBER FRAME SOLUTIONS GUIDE

CI/SfB (43) (Y) (P2) Issue 4.0 March building acoustics. acoustic floor & wall solutions

September Saddle Flooring Systems

Uniclass L531:N372. CI/SfB (23.4) R (P2) SoundDeck CLD System. A fast track acoustic floor and ceiling system

Monarfloor Acoustic Systems Product Guide

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

June Residential Refurbishment Separating walls

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

Independent twin frame high performance acoustic separating wall system

SIDERISE FLX flexible acoustic barriers for suspended ceilings

E-FT-5, E-FT-6 & FFT4

How glass or rock mineral wool works in a wall or floor cavity

E-Cousti Solutions Guide

Metal Web Floor System

Approved Document E Technical Design Report

An introduction to Part L U-values

URSA MINERAL WOOL URSA Acoustic Roll

SOUND INSULATION SLAB A family of fire resilient stone wool insulation products optimised for soundproofing

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

The SoundBar System HIGH PERFORMANCE ACOUSTIC FLOORING SOLUTION

RW SEMI-RIGID AND RIGID SLABS (RWA45, RW3, RW4, RW5 & RW6)

June Residential Refurbishment Exposed soffit floors

Acoustic Performance of Light Steel Framed Systems

Wet Areas Using Plasterboard

URSA Acoustic Roll Acoustic Insulation for Floors and Walls

Polyfoam Floorboard For thermal insulation of floors

Regupol CONSTRUCTION. Regupol BA. Heavy duty screed isolation. Regupol BA. Excellent impact performance.

Part E robustdetails. robustdetails. January 2019 Update Pack. Dear Colleague,

Introduction. Contents

April Section 4.1. Ground Floors

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

May Danskin. Thermal Saddle System. Level, insulate and reduce air leakage and all with one flooring system. Danskin

Contents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

SOUND INSULATION TESTING IN DWELLINGS

A. Proctor Group s Acoustic Credentials

Refurbishment site guidance for solid-walled houses ground floors

Internal walls. Creating perfect living spaces. Technical Advice Centre Tel:

June Residential Refurbishment Basements

Garage Conversion - Between and Under Joist Applications

C06. S05. P02 P12 GypFloor silent

C06. S05. P02 P12 GypFloor silent

Insitu Concrete Floors

Staggered stud acoustic partition system

June Non - Residential Refurbishment 5.5 Basements

Jabfloor High Performance (HP) 70 and 100

SOUND INSULATION TESTING SITE READINESS CHECKLIST

fire, thermal & acoustic insulation

The Passive Fire Protection Handbook

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

Regupol K225 5mm Impact Sound Acoustic Underlay for Bamboo Flooring

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

SOUND INSULATION DESIGN OF MODULAR CONSTRUCTION HOUSING

Loadbearing timber joist floors

Communal 51 Ceiling Systems by Vogl

T65 Impact Panels Floor System

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

Certificate No: EW687C

TIMBER FRAME HOUSING SOLUTIONS

Specifications for Insulation Board wall and ceiling applications

LEWIS Dovetailed sheeting. Dovetailed Sheeting

GypLyner IWL Independent wall lining system

Regupol K225 5mm Impact Sound Acoustic Underlay for Engineered Timber Floors

RESILIENT ACOUSTIC STUD

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

Cork, an exceptional raw material

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803

April Section Internal Walls

Multideck 146. Contents

Transcription:

ACOUSTIC SUPPLIES For Acoustic Solutions you can SHOUT about

Soundproofing and Sound Absorption Products for all types of Residential and Commercial Projects Whatever your acoustic problem, we have a solution. If it s meeting the Building Regulations, difficulties with noisy neighbours or simply the need for more peace and quiet, the JCW Acoustic Supplies range is the easy to install, cost effective answer. THE PRODUCTS Our JCW Acoustic Supplies products are suitable for new build, material change of use, refurbishment and home improvement situations. The comprehensive range includes: Acoustic Floors Acoustic Walls Acoustic Ceilings Acoustic Timber Doors Acoustic Barriers, Fencing and Gates for the outside Acoustic Ancillaries Sound Absorption Products THE BUILDING REGULATIONS Using products that have been extensively tried and tested for many years, the JCW Acoustic Supplies Range leads the way in meeting Approved Document E (England & Wales) and Section 5 (Scotland). A useful guide to the Acoustic Requirements of the Building Regulations is on Pages 4 of this brochure. SUSTAINABILITY JCW Acoustic Supplies is committed to caring for the environment and recycles material wherever possible. All JCW Acoustic Supplies timber products are bought from a sustainable, traceable source. ACOUSTIC SOLUTIONS AT A GLANCE See Pages 4 and 5 for a straightforward guide to the JCW Acoustic Supplies range and the products which comply with Robust Detail, Approved Document Part E for England, Wales and Scotland and which products to use for general acoustic improvements and refurbishment. See Page 6 for General Guidance to follow when installing our acoustic products. CE MARKING AND CONSTRUCTION PRODUCTS REGULATIONS Only products produced/supplied to a specific hen can be CE marked. Where a CE mark is required, all supporting documentation (CE mark and Declaration of Performance) can be found at www.acoustic-supplies.com as a pdf download option on the particular product page. HELP, ADVICE AND TECHNICAL SUPPORT ALL THE WAY We ll make it easy for you to get it right first time when you are installing an acoustic solution by JCW Acoustic Supplies. For larger projects or where needed, we can also offer: Easy CAD take-offs for battens and decking Installation Guides Bespoke CAD drawings for your project Indicative Acoustic Tests and UKAS Accredited Acoustic Tests For all Sales, Quotes or Technical Advice or to discuss your project and decide which of our acoustic products you'll need to achieve the required acoustic improvement or performance, contact the number shown at the base of each product page. Disclaimer: The product and installation information contained in this publication is to the best of our knowledge correct at the time of printing. We recommend you contact us direct, prior to starting works, for the latest Data Sheet information to enable confirmation of the specification. OVERVIEW What we offer 2 Building Regulations 4 Methods of Compliance 5 Installation Guidance 6 ROBUST DETAIL (FFT OVERLAYS ) Batten JCW 50C (FFT-3) Concrete 7 Batten JCW 80C (FFT-1) Concrete 8 Batten JCW 80T (FFT-1) Timber 9 Cradle & Batten System (FFT-2) Concrete 10 Impacta Mat 4.5mm (E-FC-8) Concrete 11 Deck 19 (FFT-5) Concrete 12 Deck 28 & 32 (FFT-5) Concrete 13 Perimeter Edging Strips 34 PCT/PT & REFURBISHMENT FLOORS Deck 28 & 32 Timber 14 Deck 33 Timber 15 Deck 37C 16 Deck 34 & Deck 37 17 Impactalay & Impactalay Plus 18 Acoustic Screed Foam Pack 19 Impacta Rubber 20 Acoustic Quilt 21 Perimeter Edging Strip 34 WALLS IMPROVEMENT Silent Board 22 Acoustic Quilt 23-24 Isolation Strips 25 Fire & Acoustic Socket Box Inserts 25 MULTI-PURPOSE PRODUCTS (WALLS, FLOORS & CEILINGS) Barrier Matting 26 RR20 Multi-Purpose Matting 27 Cement Board T&G (High Mass) 28 CEILINGS Acoustic Ceiling Pads 29 Thermal & Acoustic Ceiling Pads 30 Thermal Ceiling Pads 31 Noise Blocker Panel 32 Absorber Ceiling Tile 33 Fire & Acoustic Downlighter Covers 34 Sound Stop Pads 35 ABSORPTION, DOORS & FENCING Sound Absorption 36-37 Acoustic Doors 38 Acoustic Fencing 39

Acoustic Requirements Acoustic Solutions at a Glance APPROVED DOCUMENT E 20 (ENGLAND AND WALES) Dwelling-houses and flats - Performance standards for separating walls, separating floors and stairs that have a separating function between dwellings. New Build Airborne Sound Insulation Dnt,w + Ctr db (minimum values) Walls 45 Impact Sound Insulation L nt,w db (minimum values) Floors and stairs 45 62 Conversions - Material Change of Use Walls 43 Floors and stairs 43 64 Pre-completion Testing Sound insulation testing, to show compliance with the relevant performance standards should be conducted in accordance with: BS EN ISO 140-4:1998 (airborne) BS EN ISO 140-7:1998 (impact Robust Details The Robust Details Certification Scheme is a simple and reliable route to compliance. It is designed for separating walls and floors in new build dwellings only in England and Wales. For more information go to: www.robustdetails.com SECTION 5 (SCOTLAND) Airborne Sound Insulation Mean value Dnt,w db (minimum) Individual value Dnt,w db (minimum) - PCT/PT Approved Document E Timber & Concrete Floors Acoustic Batten JCW 80T timber frame. (bespoke batten depths available made to order) Acoustic Batten JCW 50C & JCW 80C See Robust Details for further options Cradle & Batten See Robust Details for further options New Build PCT req'd Conversion PCT req'd Refurbishment Remedial Floor Type (Refer to brochure for construction details) Timber PCT/PT or General Refurbishment Concrete PCT/PT or General Refurbishment Concrete PCT/PT or General Refurbishment - Robust Detail (New Build Dwellings only) Product Range Robust Detail Floor Type Batten JCW 50C (FFT 3) Batten JCW 80C (FFT 1) JCW 80T (FFT 1) Cradle & Batten (FFT 2) Deck 19 (FFT 5) E-FC-1, 2, 7 E-FS-1 E-FC-1, 2, 7 E-FS-1 E-FT-1, 2, 3 E-FS-2 E-FC-1, E-FC-2 & E-FS-1 E-FC-1, 2 E-FS-1 Rooms for residential purposes - Performance standards for separating walls, separating floors and stairs that have a separating function between dwellings. New Build Airborne Sound Insulation Dnt,w + Ctr db (minimum values) Walls 43 Impact Sound Insulation L nt,w db (minimum values) Floors and stairs 45 62 Conversions - Material Change of Use Walls 43 Floors and stairs 43 64 Walls 53 49 Floors and stairs 52 48 Airborne Sound Insulation Mean value L nt,w db (maximum) Individual value L nt,w db (maximum) Floors 61 65 Methods of Compliance Compliance to Section 5 can be shown by adherence to Specified Constructions or Performance Testing. Specified Constructions Standard Constructions that are listed in Section 5 of the Scottish Technical Handbooks. Impacta Rubber Under Screed Rubber Layer Acoustic Screed Foam Pack Under Screed Foam Layer Impacta Mat 3mm. Surface Impact Layer Impacta Mat 4.5mm Surface Impact Layer Concrete PCT/PT Concrete PCT/PT Deck 19 T&G Overlay Acoustic Deck 28 & 32 Overlay Deck 33 & Deck 37C Direct to joist option Deck 37 Cement Board Direct to joist option Impactalay 12mm. Surface Mat treatment Concrete & Timber Refurbishment Concrete PCT/PT/ Refurbishment Timber or Concrete General Refurbishment PCT/PT Timber or General Refurbishment PCT/PT Timber or General Refurbishment PCT/PT Timber or General Refurbishment Timber & Concrete or General Refurbishment Deck 28 & 32 (FFT 5) Impacta Mat (4.5mm) (Bonded Resilient Floor Cover) E-FC-1, 2 E-FS-1 E-FC-8 These products have been independently tested in a UKAS accredited laboratory and meet or exceed the minimum performance criteria as stipulated in the Robust Details handbook. Key to RD - Robust Details (Please refer to the RD Handbook for details of the required specification.) PCT - Pre-Completion Testing (England & Wales) PT - Performance Testing (Scotland) FFT - Floating Floor Treatment Laboratory values - For new internal walls and floors between all internal habitable rooms including bathroom/ w.c. within a residential property. Domestic (Non separating) Airborne Sound Insulation Rw db (minimum values) Performance Testing Sound insulation testing to show compliance with the relevant performance standards should be conducted in accordance with: BS EN ISO 140-4:1998 (airborne) BS EN ISO 140-7:1998 (impact) Impactalay Plus 15mm. Surface Mat treatment PCT/PT or General Refurbishment Walls Product Wall Type Timber Single Stud Solution Acoustic Quilt PCT/PT Walls 40 Floors and stairs 40 Methods of Compliance Compliance with Approved Document E can be shown by Pre-Completion Testing or site registration with Robust Details Ltd. Timber Double Stud Solution Metal Single Frame Solution Metal Twin Frame Solution Independent Wall Lining Solution Acoustic Liner Solution Acoustic Quilt PCT/PT Acoustic Quilt PCT/PT Acoustic Quilt PCT/PT Acoustic Quilt PCT/PT Acoustic Silent Board PCT/PT 4 5

Installation Guidance GENERAL GUIDANCE WHEN INSTALLING ACOUSTIC FLOATING FLOOR PRODUCTS The building should be watertight, with all major works completed including plastering, plumbing etc. prior to the installation of the acoustic floating floor. Floating acoustic flooring is always best installed towards the end of the project. This reduces the possibility of high moisture levels leading to expansion and contraction or general damage due to high floor loadings and on-going construction works. A brief installation guide for decking products is shown below. Full PDF installation guides are available for most products including Acoustic Battens, Cradles & Impactalay matting by calling 0845 340 2858. GENERAL INSTALLATION OF ACOUSTIC DECKING (DECK 19, 28, 32, 33, 34, 37, 37C) All acoustic floors are installed as a floating floor (NO mechanical fixings are allowed). The acoustic flooring must be isolated from the perimeter walls using either 5mm (d) foam Perimeter Edging or L Shaped Strip. Lay the acoustic boards in a staggered (brick bond) pattern and adhesive bond all joints *plus jointing screws. Cut and scribe the boards to butt up to the foam Perimeter Edging Strip using Acoustic Sealant to fill any minor gaps. Skirting boards must also be isolated from the acoustic floor surface; either maintain a clear 5mm gap or sandwich the excess foam Perimeter Edging strip between the acoustic floor and skirting board. To avoid sound transference and maintain isolation between rooms, the acoustic flooring should not be continuous. At doorways, leave a 5mm gap between adjoining boards and butt seal the boards together against a 10mm bead of Acoustic Sealant. To ensure that the acoustic floor installation is fully effective, extreme care should be taken to correctly detail and isolate the junctions between separating floors, walls & ceilings. If junctions are incorrectly detailed, the acoustic performance will be limited and the required improvements may not be achieved. The Laboratory Test Result indicated on the product data sheet is based on the structure shown. Penetrations through or within the separating elements (i.e. steels, down lighters, pipes, sockets etc.) will likely reduce the acoustic performance of any system. Please contact our Technical Helpline for further information. General Installation guidance for all other products is available on individual Data Sheets. DIRECT TO JOIST APPLICATIONS Where height is a major issue we suggest temporary decking be employed during the main building works. Direct to joist products can also be laid onto existing flat floorboards or decking. Acoustic boards should always be conditioned prior to installation. DECKING PRODUCTS AND JOIST CENTRES The following JCW Acoustic Decking products have been tested and are suitable for direct-to-flat joist application as indicated below: JCW Product Deck 28 Deck 32 Deck 33 Deck 37 Deck 37C Up to 450mm Joist Centres Up to 600mm Joist Centres GENERAL RULES FOR LAYING DECKING (DIRECT TO JOIST) 18mm chipboard and 22mm cement particle board surfaces suit a maximum 450mm joist width. 22mm chipboard surface suits a maximum joist width of 600mm. GUIDANCE FOR USING RESILIENT BARS Screw fix the pre-drilled section of the resilient bars at 400mm centres and perpendicular to the joists, battens or studs. Screw fix acoustic plasterboards to the flat underside of the resilient bars, allowing a clearance of 100mm of the supporting timbers. It is imperative that no screws penetrate through the resilient bar and into the supporting structure. 100mm minimum clearance Acoustic Batten JCW 50C CONCRETE FLOOR BATTEN FFT-3 Resilient Composite Standard Batten: Timber Batten laminated to a 9mm acoustic resilient layer Robust Detail (Registered Sites) that meets the Robust Detail requirements. Pre-completion testing is not required Acoustic Batten JCW 50C = FFT-3 Floating Floor Types; E-FC-1,2,7 and E-FS-1 (screed layer varies based on floor type. Refer to Robust Details Handbook for full specification) Size: 50mm x 42mm x 1800mm Weight: 1.2 kgs - Other batten sizes are available on request Robust Detail Performance: Reduction in Impact Sound Transmission: rd Lw = 28 db PCT/PT & Refurbishment is based on the floor structure illustrated above It is essential all components are correctly installed and detailed to meet the requirements where Pre-completion Sound Testing is required Raised floor space can be used for installing services (services between battens must not penetrate resilient layer) Ideal for good impact sound improvement where height permits In Refurbs: Overlaid onto flat timber or concrete floors Tests were carried out by Building Research Establishment Ltd, UKAS accredited test laboratory No. 78 on December 3rd 23. Test Report No. 291911. Robust Detail, PCT/PT (Scotland) See pages 4, 5 & 6 for more details and guidance 18mm t&g chipboard @ 400mm centres or 22mm t&g chipboard at 600mm centres Acoustic Batten JCW 50C JCW L Shaped or Flat Perimeter Edging Strip detail 40mm min directly applied sand & cement or proprietary screed (min 80kg/m 2 ) 150mm (min) Concrete Floor Metal Ceiling System with 100mm (min) void and 1 layer of 8kgs/m 2 gypsum based board Note: No mineral fibre quilt required between Battens on FFT-3 concrete floor types as illustrated. JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) Datasheet 21 6 7

Acoustic Batten JCW 80C CONCRETE FLOOR BATTEN Datasheet 21.1 Acoustic Batten JCW 80T TIMBER FLOOR BATTEN Datasheet 21.2 18mm t&g chipboard @ 400mm centres or 22mm t&g chipboard at 600mm centres 18mm t&g chipboard @ 400mm centres or 22 t&g chipboard at 600mm centres JCW Acoustic Batten 75 19mm Plasterboard Plank JCW L Shaped or Flat Perimeter Edging Strip detail 40mm min directly applied sand & cement or proprietary screed (min 80kg/m 2 ) 150mm (min) Concrete Floor Metal Ceiling System with 100mm (min) void and 1 layer of 8kgs/m 2 gypsum based board Note: No mineral fibre quilt required between the Battens on FFT-1 concrete floor types E-FC-1, E-FC-2, E-FC-7 and E-FS-1 Steel Deck and in-situ concrete floor type. 07 15mm OSB Board E-FT-1, E-FT-2, E-FT-3 & E-FS-2 (UltraBEAM) floor types require Mineral Wool Fibre between the battens of: either 13mm (min) 33-36 kg/m 3 or 25mm (min) 10-36 kg/m 3. E-FT-2 floor types require Mineral Wool Fibre between the battens of 60mm (min) 10-36 kg/m 3 JCW L Shaped or Flat Perimeter Edging Strip detail Resilient Bars and 2 layers x 15mm Acoustic Plasterboard 07 JCW 80T Acoustic Batten FFT-1 Resilient Composite Deep Batten System: Timber Batten laminated to a 9mm acoustic resilient layer FFT-1 Resilient Composite Deep Batten System Robust Detail (Registered Sites) that meets the Robust Detail requirements. Pre-completion testing is not required Acoustic Batten JCW 80C = FFT-1 Floating Floor Types; E-FC-1,2,7 and E-FS-1 (screed layer varies based on floor type. Refer to Robust Details Handbook for full specification) PCT/PT & Refurbishment is based on the floor structure illustrated above It is essential all components are correctly installed and detailed to meet the requirements where Pre-completion Sound Testing is required Raised floor space can be used for installing services Ideal for good impact sound improvement where height permits In Refurbishments: Overlaid onto flat timber or concrete floors Timber batten laminated to a 9mm acoustic resilient layer Robust Detail (Registered Sites) that meets the Robust Detail requirements. Pre-completion testing is not required Acoustic Batten JCW 80T = FFT-1 Floating Floor types: E-FT-1,2,3 & E-FS-2 (Refer to Robust Details Handbook for full specification) PCT/PT & Refurbishment is based on the floor structure illustrated above It is essential all components are correctly installed and detailed to meet the requirements where Pre-completion Sound Testing is required Size: 80mm x 42mm x 1800mm Weight: 1.9 kgs (JCW 80T) - Other batten sizes are available on request Size: 80mm x 42mm x 1800mm Weight: 1.7 kgs - Other batten sizes are available on request Robust Detail Performance: Reduction in Impact Sound Transmission: rd Lw = 31 db Tests were carried out by Building Research Establishment Ltd, UKAS accredited test laboratory No. 78 on December 3rd 23. Test Report No. 291911. Robust Detail, PCT/PT (Scotland) See pages 4, 5 & 6 for more details and guidance JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) Robust Detail Performance: Reduction in Impact Sound transmission; rd Lw = 16 db Improvement in Airborne Sound insulation; rd Rw + Ctr = 13 db Tests were carried out by Sound Research Laboratories, UKAS accredited test laboratory No. 44 on the 7th October 23. Test Report No. C/22610/T Robust Detail, PCT/PT (Scotland) See pages 4, 5 & 6 for more details and guidance At a glance details and general guidance pages 4,5 & 6 JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) JCW Fire & Acoustic Sealant (310ml) 8 9

Acoustic Cradle Levelling System CONCRETE FLOOR CRADLE & BATTEN Datasheet 52 Acoustic Impacta Mat 4551 CONCRETE FLOOR SOFT COVERING MAT Datasheet 30 18mm t&g chipboard @ 400mm centres JCW Acoustic Impacta Mat 40mm min directly applied sand & cement or proprietary screed (min 80kg/m 2 ) JCW Acoustic Cradle Levelling System 150mm (min) Concrete Floor 65mm sand & cement screed layer or 40mm proprietary screed (min 80kg/m 2 ) JCW L Shaped or Flat Perimeter Edging Strip detail Metal Ceiling System with 100mm (min) void and 1 layer of 8kgs/m 2 gypsum based board 150mm (min) Concrete Floor Note: Beam & Block floor type E-FC-7 requires Mineral Wool Fibre between the battens of 25mm (min) 10-36 kg/m 3. Metal Ceiling System with 100mm (min) void and 1 layer of 8kgs/m 2 gypsum based board JCW Acoustic Cradle Levelling System FFT-2 Resilient Cradle and Batten System Robust Detail (Registered Sites) Verified independent UKAS accredited laboratory test data meets the Robust Detail requirements. Pre-completion Testing is not required Acoustic Cradles = FFT-2 Floating Floor Types: E-FC-1, E-FC-2 & E-FS-1 (Beam & Block floor type E-FC-7 floor specification varies, refer to Robust Details Handbook for full specification) Refer to page 5 for further information Reduction in Impact Sound Transmission: rd Lw 28 db PCT/PT & Refurbishment Verified independent UKAS accredited laboratory test data is based on the floor structure illustrated above It is essential all components are correctly installed and detailed to meet the requirements where Pre-completion Sound Testing is required Refer to page 5 for further information 1. 2mm Packers 2. Acoustic Cradle 3. 20mm Stacker 4. 10mm Acoustic Foam 1. 2. 3. 4. 3.0mm & 4.5mm Recycled rubber bonded with cork granulate: Impact sound bonded surface layer for concrete floors Robust Detail (Registered Sites) that meets Robust Detail requirements. Pre-completion testing is not required Acoustic Impacta Mat 4.5mm = Bonded Resilient Floor Covering for floor type: E-FC-8 (Refer to Robust Details Handbook for full specification) Refer to page 5 for more information Roll Sizes: 3.0mm x 10mm x 20m (21.00 m 2 ) 4.5mm x 10mm x 10m (10.50 m 2 ) PCT/PT & Refurbishment is based on the floor structure illustrated above Impacta Mat 4.5mm when fully bonded to the sub-floor meets the Building Regulation requirements for Impact Reduction on all pre-cast concrete/beam & block floors that have a minimum mass of 300kg/m 2 Impacta Mat 3mm provides a good Impact Reduction for refurbishment projects Suitable beneath most floor finishes e.g. laminate, carpet, vinyls and ceramic tiles. Seek specialist advice for tiles and vinyls Reduction in Impact Sound transmission 4.5mm Lw = 21 db 3.0mm Lw = 18 db Robust Detail, PCT/PT (Scotland) See pages 4, 5 & 6 for more details and guidance JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) Robust Detail, PCT/PT (Scotland) See pages 4, 5 & 6 for more details and guidance JCW Impacta Adhesive 10 11

Acoustic Deck 19 CONCRETE FLOOR OVERLAY BOARD Datasheet 25 Acoustic Deck 28/32 CONCRETE FLOOR OVERLAY BOARD Datasheet 26.1 JCW Acoustic Deck 19 JCW Acoustic Deck 28/32 40mm min directly applied sand or proprietary screed (min 80kg.m 2 ) 40mm min directly applied sand & cement or proprietary screed (min 80kg/m 2 ) 150mm (min) Concrete Floor 150mm (min) Concrete Floor JCW L Shaped or Flat Perimeter Edging Strip detail Metal Ceiling System with 100mm (min) void and 1 layer x 8kgs/m 2 gypsum based board JCW L Shaped or Flat Perimeter Edging Strip detail Metal Ceiling System with 100mm (min) void and 1 layer of 8kgs/m 2 gypsum based board MDF based acoustic overlay board for concrete floors: 9mm t&g laminated to an acoustic resilient layer 18mm or 22mm P5 T&G Chipboard with a pre-bonded 10mm resilient foam layer Robust Detail (Registered Sites) that meets the Robust Detail requirements. Pre-completion testing is not required Acoustic Deck 19 = FFT-5 Floating Floor types E-FC-1,2 & E-FS-1 (screed layer varies, refer to Robust Details Handbook for full specification) Sheet Size: 19mm x 600mm x 1200mm (0.72 m 2 ) PCT/PT & Refurbishment is based on the floor structure illustrated above It is essential all components are correctly installed and detailed to meet the requirements where Pre-completion Sound Testing is required Offers good impact sound improvement Deck ready for final floor finish e.g.laminates, carpets and carpet tiles (vinyls may require additional floor preparation) In Refurbishments: Overlaid onto flat timber or concrete floors Robust Detail (Registered Sites) meets the Robust Detail requirements. Pre-completion Testing is not required Deck 28/32 = FFT-5 Floor Types: E-FC-1,2 & E-FS-1 (screed layer varies, refer to Robust Details Handbook for full specification) Deck 28 Sheet Size: 28mm x 600mm x 2400mm (1.44 m 2 ) Weight: 17.8 kgs Deck 32 Sheet Size: 32mm x 600mm x 2400mm (1.44 m 2 ) Weight: 21.8 kgs Reduction in Impact Sound Transmission Lw 18 db PCT/PT & Refurbishment is based on the floor structure illustrated above It is essential all components are correctly installed and detailed to meet the requirements where Pre-completion Sound Testing is required Reduction in Impact Sound Transmission as tested in UKAS accredited laboratory: Lw 18 db Robust Detail, PCT/PT (Scotland) See pages 4, 5 & 6 for more details and guidance JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) Robust Detail, PCT/PT (Scotland) See pages 4, 5 & 6 for more details and guidance JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) 12 13

Acoustic Deck 28/32 ECONOMICAL OVERLAY OR DIRECT TO JOIST BOARD Datasheet 26.2 Acoustic Deck 33 PREMIUM OVERLAY OR DIRECT TO JOIST BOARD Datasheet 12 JCW Acoustic Deck 28/32 JCW Acoustic Deck 33 Existing Subfloor Existing Subfloor JCW L Shaped or Flat Perimeter Edging Strip detail JCW L Shaped or Flat Perimeter Edging Strip detail 100mm x 45kgs/m 3 Mineral Wool Slab Resilient Bars and 2 layers x 15mm Acoustic Plasterboard Resilient Bars and 2 layers x 15mm Acoustic Plasterboard 100mm x 45kgs/m 3 Mineral Wool Slab 225mm depth Timber Joists 225mm depth Timber Joists Economical overlay or direct to joist board Acoustic Floating Floor: 18mm or 22mm T&G P5 chipboard with a pre-bonded 10mm foam resilient layer. Refurbishment Low cost product ideal for both general and new domestic separating floor upgrades in lofts and extensions etc Good Impact and Airborne sound reduction Ideal for floated wood, laminate, carpets/carpet tiles. Additional floor preparation may be required for tiling and vinyl overlays Refer to page 4, 5 & 6 for further information Deck 28 Sheet Size: 28mm x 600mm x 2400mm (1.44 m 2 ) Weight: 17.8 kgs Deck 32 Sheet Size: 32mm x 600mm x 2400mm (1.44 m 2 ) Weight: 21.8 kgs PCT/PT Economical system for Conversion projects It is essential the recommended components shown above are used and correctly installed/detailed to meet the requirements where Pre-completion Sound Testing is required Refer to page 4, 5, 6 & data sheet for further information refer UKAS laboratory test data based on Direct to Joist construction: Impact: 56 db Ln,w Airborne: Rw + Ctr 52 db Chipboard based premium acoustic overlay or direct to joist board for timber floors Acoustic Floating Floor: 18mm P5 t&g chipboard with a pre-bonded 15mm high performance resilient layer Refurbishment Ideal for both general and new domestic separating floor upgrades in lofts and extensions etc Enhanced Impact and Airborne sound reduction via superior 15mm barrier-foam-barrier pre-bonded backing Ideal decking for floated wood, laminate, carpet/carpet tiles. Additional floor preparation will be required for tiling and vinyl overlays Refer to page 4, 5 & 6 for further information Sheet Size: 33mm x 600mm x 2400mm (1.44 m 2 ) Weight: 26.5 kgs PCT/PT Economical system for both Conversion & New Build projects It is essential recommended components shown above are used and correctly installed/detailed to meet the requirements where Pre-completion Sound Testing is required Refer to page 4, 5 & 6 for further information UKAS laboratory test data based on Direct to Joist construction: Impact: 51 db Ln,w Airborne: Rw + Ctr 55 db PCT/PT (Scotland) JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) PCT/PT (Scotland) JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) 14 15

Acoustic Deck 37C PREMIUM OVERLAY OR DIRECT TO JOIST BOARD Datasheet 53 Acoustic Deck 34 & Deck 37 DECK 34 PREMIUM OVERLAY BOARD OR DECK 37 DIRECT TO JOIST BOARD Datasheet 19 JCW Acoustic Deck 37C JCW Acoustic Deck 34 & Deck 37 225mm depth Timber Joists JCW L Shaped or Flat Perimeter Edging Strip detail Resilient Bars and 2 layers x 15mm Acoustic Plasterboard 100mm x 45kgs/m 3 Mineral Wool Slab JCW L Shaped or Flat Perimeter Edging Strip detail Resilient Bars and 2 layers x 15mm Acoustic Plasterboard 225mm depth Timber Joists 100mm x 45kgs/m 3 Mineral Wool Slab Deck 34 Chipboard based acoustic deck for direct to joist fitment or onto an existing sub-floor Acoustic Floating Floor: 22mm P5 t&g chipboard with a pre-bonded 15mm high performance resilient layer Refurbishment Ideal for both general and new domestic separating floor upgrades in lofts and extensions etc Enhanced Impact and Airborne sound reduction via superior 15mm barrier-foam-barrier pre-bonded backing Ideal decking for floated wood, laminate, carpet/carpet tiles. Additional floor preparation will be required for tiling and vinyl overlays Refer to page 4, 5 & 6 for further information Sheet Size: 37mm x 600mm x 2400mm (1.44 m 2 ) Weight: 31 kgs PCT/PT Economical system for both Conversion & New Build projects It is essential recommended components shown above are used and correctly installed/detailed to meet the requirements where Pre-completion Sound Testing is required Refer to page 4, 5 & 6 for further information UKAS laboratory test data based on Direct to Joist construction: Impact 52 db Ln,w Airborne: Rw + Ctr 55 db Deck 34 Premium Overlay board or Deck 37 Premium Direct to Joist board Acoustic Floating Floor: Deck 34: 22mm t&g Cement Based Board with a pre-bonded 12mm high performance resilient layer Deck 37: 22mm t&g Cement Based Board with a pre-bonded 15mm high performance resilient layer Refurbishment Ideal for both general and new domestic separating floor upgrades in lofts and extensions etc Enhanced airborne sound reduction achieved via mass board weight, high performance barrier mat and foam pre-bonded Impact layer Ideal decking for tiling, floated wood, laminate, carpets/ carpet tiles. Additional floor preparation may be required for vinyl overlays Refer to page 4, 5 & 6 for further information PCT/PT Superior performance system for both Conversion & New Build projects It is essential recommended components shown above are used and correctly installed/detailed to meet the requirements where Pre-completion Sound Testing is required Refer to page 4,5 & 6 for further information PCT/PT (Scotland) JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) Sheet Sizes: Deck 34: 34mm x 600mm x 1200mm (0.72 m 2 ) Weight: 23 kgs Deck 37: 37mm x 600mm x 1200mm (0.72 m 2 ) Weight: 25.1 kgs UKAS laboratory test data based on Direct to Joist construction: Deck 37 Direct to Joist or Deck 34 overlaid onto Decking Deck 34 Impact: 49 db Lnt,w Airborne: 57 db Rw + Ctr, Deck 37 Impact: 50 db Lnt,w Airborne: 57 db Rw + Ctr PCT/PT (Scotland) JCW Universal L Shaped Strip (2 Lm x 53mm x 23mm) JCW Waterproof PVA Adhesive (1 Litre) 16 17

Acoustic Impactalay (Plus) PREMIUM RESILIENT OVERLAY MATTING Datasheet 10 Acoustic Screed Foam Pack CONCRETE FLOOR UNDER SCREED RESILIENT LAYER Datasheet 56 Existing Subfloor JCW Impactalay (Plus) JCW Impactalay Resilient Bars and 2 layers x 15mm Acoustic Plasterboard 65mm sand & cement screed can be laid directly on top of Screed Foam. 40mm proprietary screeds (min 80kg/m 2 ) require a Polythene layer above the Screed Foam covering the whole floor area with overlapped & taped joints JCW Acoustic Screed Foam 100mm x 45kgs/m 3 Mineral Wool Slab 225mm depth Timber Joists 150mm (min) Concrete Floor Overlap a minimum of 50mm and tape all joints JCW Acoustic Screed Foam perimeter edging strip detail. Foam Flanking Strip is scored for ease of use Acoustic Overlay Matting System for timber and concrete floors Impactalay Plus: two acoustic layers of barrier mat with a resilient chip foam core Impactalay: a single acoustic barrier mat layer with a resilient chip foam base Refurbishment Ideal domestic Impact and Airborne sound insulation product where height is restricted Easily cut, trimmed and shaped for fast installation Impactalay Matting can be loose laid with taped joints or fully bonded to the sub-floor. Carpets and Engineered Wood floor overlays can be laid directly on top. Gripper Edging Strips are required with carpet installations to raise and support the carpet gripper strips Due to the resilient nature of Impactalay & Plus, thin Wood Laminates will require a 6mm bonded ply layer. T&G 6mm or 9mm MDF is suggested when installing bonded carpet, carpet tiles, vinyl & rubber flooring to reduce point loading & joint creasing See data sheet for further guidance Refer to page 4, 5 & 6 for more information PCT/PT 15mm Impactalay Plus overlay system could be considered for Conversion projects based on the above structure It is essential the recommended components shown above are correctly installed and detailed when Pre-completion Sound Testing is required See data sheet for further guidance Refer to page 4, 5 & 6 for more information Sheet Size: Impactalay: 12mm x 1200mm x 1000mm (1.2 m 2 ) Weight m 2 : 8 kgs/m 2 Sheet Weight: 9.6 kgs Sheet Size: Impactalay Plus: 15mm x 600mm x 1200mm (0.72 m 2 ) Weight m 2 : 15 kgs/m 2 Sheet Weight: 10.80 kgs UKAS accredited laboratory test data for the Floor Construction above: Impactalay (12mm): Impact: 38 db Ln,w Airborne Rw + Ctr: 49 db Rw + Ctr Impactalay Plus (15mm): Impact: 39 db Ln,w Airborne Rw + Ctr: 51 db Rw + Ctr PCT/PT (Scotland) JCW Impactalay Plus Gripper Strip JCW Black Cloth Jointing Tape JCW Impacta Adhesive 1. 2. Concrete Floor Types Acoustic Screed Foam Pack can be used on pre-cast concrete plank floors that have a minimum mass of 300 kg/m 2 with a ceiling type illustrated above Suitable for underfloor heating Screed Foam Pack is economical and easy to install. Pack includes 150mm (h) pre-scored, flanking strip and black cloth jointing tape Acoustic Performance: Impact Ln,w = 54 db Airborne DnT,w + Ctr = 49 db PCT/PT (Scotland) 3. Metal Ceiling System with 150mm (min) void and 1 layer of 8kgs/m 2 gypsum based board Big value Acoustic Screed Foam Pack contains: 1. JCW Acoustic Flanking Strip 150mm x 50Lm x 8mm Foam Strip Roll Weight 0.4kg 2. JCW Acoustic Screed Foam 52 Lm x 1.2m x 10mm (62.4 m 2 per pack) Floor coverage 58.8m 2 appx 3. JCW Black Cloth Jointing Tape 50Lm x 50mm PCT & PT Scotland Acoustic Screed Foam under screed Impact layer for beneath sand & cement or proprietary screeds based on the floor and ceiling structure illustrated above It is essential all components are correctly installed and detailed to meet the requirements where Pre-completion Sound Testing is mandatory 18 19

Acoustic Impacta Rubber CONCRETE FLOOR UNDER SCREED RESILIENT LAYER Datasheet 29 Acoustic Quilt INDEPENDENT FLOOR/CEILING IMPROVEMENT Datasheet 51.1 65mm sand & cement screed can be laid directly on top of Impacta Rubber. 40mm proprietary screeds (min 80kg/m 2 ) require a Polythene layer above the Impacta Rubber covering the whole floor area with overlapped & taped joints JCW Acoustic Impacta Rubber 18mm (min) t&g Chipboard Existing Floor Joists 2 x layers x 15mm Acoustic Plasterboard Independent Joists 47mm x 100mm on hangers at 400mm centres JCW Acoustic Impacta Rubber perimeter edge detail. Foam Flanking Strip is scored for ease of use Acoustic Quilt can be fitted between existing joists or studwork to provide acoustic improvement 150mm (min) Concrete Floor Metal Ceiling System with 150mm (min) void and 1 layer of 8kgs/m 2 gypsum based board Overlap a minimum of 50mm and tape all joints Premium acoustic partition roll manufactured by sandwiching an acoustic barrier membrane between 2 layers of glass mineral wool JCW Acoustic Flanking Strip Under screed resilient Impact layer for all floor types shown when Pre-completion Sound Testing is required. Independent ceiling for optimal sound insulation Ideal where access is only possible from below Glass mineral wool layers complement the barrier membrane by absorbing sound Bonded recycled rubber granulate Concrete Floor Types Impacta Rubber can be used on all pre-cast concrete plank/beam & block floors that have a minimum mass of 300 kg/m 2 and a metal framed ceiling type as illustrated above Suitable for underfloor heating Impacta Rubber is economical and easy to install Accessories needed: 150mm (h) pre-scored Flanking Strip. Black Cloth Jointing tape PCT & PT Scotland Acoustic Impacta Rubber under screed Impact layer for beneath sand & cement or proprietary screeds is based on the floor structure illustrated above It is essential all components are correctly installed and detailed to meet the requirements for PCT and PT (Scotland) where Pre-completion Sound Testing is required Roll Size: 52mm x 600mm x 5m (3.00 m 2 ) Weight: 9 kgs 52mm x 1200mm x 5m (6.00 m 2 ) Weight: 18 kgs Typical Acoustic Performance of Ceiling Construction shown above Impact: 57 db Ln,w Airborne: 54 db Rw + Ctr Approved Document E/ Section 5 Scotland JCW Acoustic Isolation Strips JCW Fire & Acoustic Downlighter Covers Roll Size: 5mm x 1000mm x 10m (10.00 m 2 ) Roll Weight: 20.5 kgs Typical Acoustic Performance of Floor Construction shown above. Impact: L'nt,w 54 db Airborne: D'nt,w + Ctr 49 db Approved Document E/ Section 5 Scotland JCW Black Cloth Jointing Tape JCW Acoustic Flanking Strip 20 21

Acoustic Silent Board ACOUSTIC WALL LINER Datasheet 28 Acoustic Quilt SINGLE FRAME PARTITION WALL Datasheet 51.2 100mm Lightweight Block JCW Acoustic Silent Board All board jointing to be sealed with Acoustic Sealant. At wall, floor & ceiling edges either leave 5mm gap and fully fill with Acoustic Sealant or butt boards up to 5mm Isolating Strips and seal minor gaps with Acoustic Sealant. Use mechanical frame fixings on brick/ block walls and screw fixings on stud work 2 layers of staggered 15mm Acoustic Plasterboard 70mm Acoustic Metal Studs Resilient Bars JCW Acoustic Quilt 2 layers of staggered 15mm Acoustic Plasterboard Acoustic overlay improvement board for new and existing walls Acoustic plasterboard laminated to an acoustic resilient layer Can be fitted directly to existing brick, block and stud walls. Simple to fit Could be used as a remedial solution for sound test failures Plasterboard surface ready for decoration Sheet Size: 27.5mm x 1200mm x 1200mm (1.44 m 2 ) Weight: 24.7 kgs Typical Acoustic Performance of Wall Construction shown above Airborne: 45 db Rw + Ctr Approved Document E/ Section 5 Scotland JCW Acoustic Isolation Strips JCW Fire & Acoustic Socket Box Inserts Premium acoustic partition roll manufactured by sandwiching an acoustic barrier membrane between 2 layers of glass mineral wool Enhanced performance metal stud partition Easily fitted using dry lining skills Glass mineral wool layers complement the barrier membrane by absorbing sound Roll Size: 52mm x 600mm x 5m (3.00 m 2 ) Weight: 9 kgs 52mm x 1200mm x 5m (6.00 m 2 ) Weight: 18 kgs Typical Acoustic Performance of Wall Construction shown above Airborne: 50 db Rw + Ctr Approved Document E/ Section 5 Scotland JCW Acoustic Isolation Strips JCW Fire & Acoustic Socket Box Inserts 22 23

Acoustic Quilt INDEPENDENT WALL LINING Datasheet 51.3 Acoustic Isolation Strip ANCILLARY PRODUCTS Datasheet 09 Min 20mm Air Gap between wall and metal stud Stud fixed to surrounding wall/floor/ceiling not to offending wall 100mm Lightweight Block Wall JCW Acoustic Quilt JCW Acoustic Isolation Strips JCW Acoustic Isolation Strips Multi-Purpose Acoustic Isolation Strip Manufactured from bonded recycled rubber - for isolating parts of a structure where any point of contact could compromise its acoustic integrity 1 layer x 15mm Acoustic Plasterboard 50mm Independent Metal Stud Roll Size 5mm x 50mm x 10m 5mm x 75mm x 10m 5mm x 100mm x 10m 5mm x 150mm x 10m 5mm x 225mm x 10m 5mm x 300mm x 10m JCW Acoustic Isolation Strips Premium acoustic partition roll manufactured by sandwiching an acoustic barrier membrane between 2 layers of glass mineral wool Independent partition with 20mm air gap Easily fitted using dry lining skills Glass mineral wool layers complement the barrier membrane by absorbing sound Roll Size: 52mm x 600mm x 5m (3.00 m 2 ) Weight: 9 kgs 52mm x 1200mm x 5m (6.00 m 2 ) Weight: 18 kgs Typical Acoustic Performance of Wall Construction shown above Airborne: 49 db Rw + Ctr Fire & Acoustic Socket Box Inserts ANCILLARY PRODUCTS Datasheet 24 Designed to help maintain the fire resistance and acoustic integrity of walls suitable for both plastic and metal socket boxes easy to install putty pad alternative Approved Document E/ Section 5 Scotland JCW Acoustic Isolation Strips JCW Fire & Acoustic Socket Box Inserts Single x 35mm deep Double x 35mm deep Single x 47mm deep Double x 47mm deep 24 25

Acoustic Barrier Mat MULTI-PURPOSE SOLUTION Datasheet RR20 Multi- Purpose Matting POLYURETHANE BOUND RUBBER GRANULATE MATERIAL Datasheet 57 Thicknesses 1.2mm, 2mm, 3mm, 4mm Multi-purpose, dense acoustic barrier matting. Barrier Matting offers very good airborne performance across the frequency range. JCW RR20 is a high performance, cost effective polyurethane bound rubber granulate material. RR20 is different to other products as it is both recyclable and yet will retain its acoustic properties throughout a long and maintenance free lifespan. Mat Dimensions: 1m x 1m Standard Thickness: 20mm (other thicknesses available on request) Weight: RR20mm is 15.6 kgs/m 2 Noticeable improvements will be gained when bonding barrier matting between two layers of Plasterboard on walls & ceilings or pinning on to stud work or joists prior to plasterboard fixing Noticeable airborne improvement gain with minimal height loss when 2 x 2mm barrier matting layers are laid on the floor in opposite directions Hanging Curtain: Ideal as a separating curtain wall between offices above walls Perfect product for dampening steelwork, ducting and machinery casings etc Mean Sound Reduction Index 1.2mm (3.0 kgs/m 2 ): 16 db 2mm (5.0 kgs/m 2 ): 21 db 3mm (7.5 kgs/m 2 ): 24 db 4mm (10.0 kgs/m 2 ): 27 db See pages 4, 5 & 6 for more details and guidance Tested and rated according to BS EN ISO 717-1: 1997, BS EN ISO 140-3: 1995 and BS EN ISO 2750: Part 3 Transmission Loss Data: db Material/Frequency (Hz) 125 250 500 1k 2k 4k JCW B3 9 12 16 21 24 28 JCW B5 14 17 21 27 30 34 JCW B7.5 17 20 24 29 32 36 JCW B10 19 23 27 33 36 40 Product Roll Roll Weight Weight Size per roll 3.0 kgs/m 2 1.2mm x 1200mm x 5m 18 kgs 5.0 kgs/m 2 2mm x 1200mm x 5m 30 kgs 7.5 kgs/m 2 3mm x 1200mm x 4m 36 kgs 10.0 kgs/m 2 4mm x 1200mm x 2m 24 kgs Maximum Load Bearing Capacity: 0.N/mm 2 (5000kgs/m 2 ) Temperature Resistance: -40ºC up to +110 C Static Modulus of Elasticity*: 0.10-0.44N/mm 2 Compression Set to DIN 53572**: Approx. 4.10% Tensile Strength to DIN 53571: Min 0.30N/mm 2 Elongation at Break to DIN 53571: Min 60% Tear Resistance to DIN 53515: Min 3.0N/mm Flammability: Class B2 Thermal Conductivity: 0.14W/mK * Figures dependent upon load, natural frequency and material thickness ** Measured 30 minutes after decompression with 50% deformation @ 23 C after 72 hours Excellent dampening and isolation characteristics Quick and easy to cut, trim & lay Adhesive bonding reduces the need for mechanical fixing JCW RR20 has a multitude of applications including: airborne wall improvement, impact and vibration reduction through floors and sound dampening of enclosures and panels. The product is therefore typically suitable for: Airborne reduction: through walls & floors Impact reduction: through floors via vertical shock loads in Gyms, and machinery types such as power presses etc Vibration reduction: through floors & walls via Refrigeration units and compressors etc Dampening: Internal structures & panels WALL application: RR20 is most commonly applied to brick/ plastered walls that are virtually impervious; the suggested adhesive is a (double stick) Contact Adhesive applied to both surfaces. Due to the wide range of RR20 uses, the fixing method will vary depending on the application. Note: Where adhesive bonding is required the walls or floors must be dry, flat & prepared to enable the adhesive to bond correctly. 26 27

Calibrated Cement Particle Board MULTI-PURPOSE PARTICLE BOARD FOR FLOORS, WALLS AND CEILINGS Datasheet 58 Acoustic Ceiling Pads SUSPENDED CEILING INSULATION (PERFORATED TILES) Datasheet 31 18mm thick high mass cement particle board for floors walls and ceilings JCW Acoustic Calibrated Cement Particle Board is a high density overlay acoustic product suitable for floors, walls and ceilings, specially designed to add concentrated mass. They are used where there is a requirement for a high performance result in acoustic control and fire performance. Ceiling Improvement: JCW (Calibrated) 18mm T&G Cement Bonded Particle Boards will improve the overall acoustic performance based on the boards mass content and the ability to reduce sound leakage via T&G jointing. Resilient Bars: JCW (Calibrated) 18mm T&G Cement Bonded Particle Boards supported on Single Fix resilient bars (max weight approx 30kg.m 2 ) or Twin Fix resilient bars (max weight approx 50kg.m 2 ) will considerably improve the airborne and impact performance. Density (average): 1250kg/m 3 1. Thickness Tolerances Calibrated: 8-37mm+0.3mm 2. Length: +5mm 3. Width: +5mm 4. Squareness: -2.5mm on panel diagonal difference JCW Waterproof PVA Adhesive (1 ltr) JCW Universal L Shaped Edging Strip (2 Lm x 53mm x 23mm) JCW Acoustic Isolation Strips (various) Wall Improvement: Prior to starting, place JCW Acoustic Isolation Strips on the floor, perimeter walls and ceiling to isolate all boards from the structure. Install the wall boards onto resilient bars as per Ceilings above. Flooring with a resilient layer: see Deck 37 data sheet. Fire Rating: 30mins = 18mm (22.5kg m 2 ) / 60mins with an additional layer of 12.5mm Fire Rated board. Surface Alkalinity: ph between 11 and 13 Moisture Content (ex production): 9% + 3% by weight Thickness Swelling (24hrs immersion): 0.7% (average) Thermal Conductivity Coefficient: 0.26.W/m.k. See pages 4,5 & 6 for more details and guidance Reinforced foil wrapped backing with Black Tissue facing, filled with acoustic Rock Fibre Wool Slab. Class O to The Building Regulations Reduces room to room sound transfer Designed to absorb sound within the room Black Tissue shows through ceiling perforations Size Density Quantity 25mm x 600mm x 600mm 45 kgs/m 3 10 per pack 28 29

Thermal & Acoustic Ceiling Pads SUSPENDED CEILING INSULATION Datasheet 31.1 Thermal Ceiling Pads SUSPENDED CEILING INSULATION Datasheet 43 Black Polythene Enclosed Glass Mineral Wool Pads for the thermal insulation above a suspended mineral fibre or drop in ceiling tile Range of thicknesses to meet thermal performance Suitable for most suspended ceiling systems Allows easy access to the ceiling void Polythene enclosed for dust sensitive areas Polythene thickness: 160 Gauge Glass Mineral Wool Mat Fire Performance: Euroclass A1 to BS EN ISO 135-1 Black Polythene Enclosed Rock Mineral Wool Slab for thermal & acoustic insulation above a mineral fibre or drop in ceiling tile. Reduces room to room sound transfer Helps absorb sound within rooms Allows easy access to the ceiling void Size Density Quantity 25mm x 600mm x 600mm 45 kgs/m 3 10 per pack 25mm x 300mm x 1200mm 45 kgs/m 3 10 per pack 25mm x 600mm x 1200mm 45 kgs/m 3 5 per pack 50mm x 600mm x 600mm 45 kgs/m 3 10 per pack 25mm x 600mm x 600mm 60 kgs/m 3 10 per pack Thickness Size Density Pack Size Thermal R Values 25mm 600mm x 600mm 20kgs/m 3 10 pads per pack (3.60 m 2 ) 0.65 m 2 /KW 25mm 600mm x 1200mm 20kgs/m 3 5 pads per pack (3.60 m 2 ) 0.65 m 2 /KW 50mm 600mm x 600mm 16kgs/m 3 10 pads per pack (3.60 m 2 ) 1.35 m 2 /KW 50mm 600mm x 1200mm 16kgs/m 3 5 pads per pack (3.60m 2 ) 1.35 m 2 /KW 60mm 600mm x 600mm 10kgs/m 3 10 pads per pack (3.60 m 2 ) 1.50 m 2 /KW 60mm 600mm x 1200mm 10kgs/m 3 5 pads per pack (3.60 m 2 ) 1.50 m 2 /KW 80mm 600mm x 600mm 10kgs/m 3 10 pads per pack (3.60 m 2 ) 2.00 m 2 /KW 80mm 600mm x 1200mm 10kgs/m 3 5 pads per pack (3.60 m 2 ) 2.00 m 2 /KW 100mm 600mm x 600mm 10kgs/m 3 10 pads per pack (3.60 m 2 ) 2.50 m 2 /KW 100mm 600mm x 1200mm 10kgs/m 3 5 pads per pack (3.60 m 2 ) 2.50 m 2 /KW 150mm 600mm x 600mm 10kgs/m 3 10 pads per pack (3.60 m 2 ) 3.75 m 2 /KW 150mm 600mm x 1200mm 10kgs/m 3 5 pads per pack (3.60 m 2 ) 3.75 m 2 /KW 200mm 600mm x 600mm 10kgs/m 3 10 pads per pack (3.60 m 2 ) 5.00 m 2 /KW 200mm 600mm x 1200mm 10kgs/m 3 5 pads per pack (3.60 m 2 ) 5.00 m 2 /KW 250mm 600mm x 600mm 10kgs/m 3 10 pads per pack (3.60 m 2 ) 6.25 m 2 /KW 250mm 600mm x 1200mm 10kgs/m 3 5 pads per pack (3.60 m 2 ) 6.25 m 2 /KW All other sizes available Other sizes not shown above can be manufactured to order 30 31

Noise Blocker Panels SUSPENDED CEILING INSULATION Datasheet 54 Absorber Ceiling Tile ACOUSTIC CEILING TILE Datasheet 14 Class O Foam laminated to an acoustic plasterboard layer Noise Blocker Panel 16 Noise Blocker Panel 19 Noise Blocker Panel 25 Reduces room to room sound transfer Economical acoustic solution for new/retrofit installations Reduces sound transfer between the separating ceiling Cost effective acoustic solution Install with the foam facing upward into the void for grid systems with in-situ mineral fibre tiles OR on a perforated grid with a mineral wool tile (i.e. foil enclosed pads) installed. Install with the foam facing downward on perforated grids without mineral wool pads installed. Noise Blocker Panel 16 reduces room to room sound transfer in standard commercial office areas Noise Blocker Panel 19 offers enhanced levels of room to room sound reduction for more private areas Noise Blocker Panel 25 is designed for areas requiring higher levels of room to room sound reduction Sheet Size (to fit 600mm x 600mm grid) Noise Blocker Panel 16: 16mm x 595mm x 595mm Noise Blocker Panel 19: 19mm x 595mm x 595mm Noise Blocker Panel 25: 25mm x 595mm x 595mm Typical Sound Reduction through ceiling Noise Blocker Panel 16: 24 db Noise Blocker Panel 19: 26 db Noise Blocker Panel 25: 27 db Glass mineral fibre acoustic core board with white speckled surface finish and bevelled edges Can be direct bonded to existing ceiling Acoustic Performance Sound Absorption Co-efficient (tested to BS EN ISO 354:20) Can be fitted as a hanging acoustic absorber Spacers & corkscrew fitting optional extra 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz Tile Size: 20mm x 600mm x 1200mm Weight: 2.5kgs/m 2 0.10 0.30 0.80 1.00 1.00 0.85 32 33

Fire & Acoustic Downlighter Covers ANCILLARY PRODUCTS Datasheet 18 Sound Stop Pads ACOUSTIC CEILING PADS FOR SUSPENDED CEILINGS Datasheet 69 Designed to help maintain the fire resistance and acoustic integrity of ceilings they are ventilated to reduce heat build up 600x600x50mm 1200x600x50mm Cover Size Small 150mm x 150mm Medium 200mm x 200mm Large 250mm x 250mm X-Large 300mm x 170mm XX-Large 350mm x 230mm Ceiling Cutout Size 50mm - 75mm 75mm - 100mm 100mm - 140mm 140mm - 270mm 140mm - 270mm The Products JCW Sound Stop Acoustic Pads are an easy to install sound blocking pad designed to be laid on top of suspended ceiling grid tiles. Suspended ceilings are often common to offices/rooms separated by walls constructed beneath the ceiling grid allowing sound to penetrate the ceiling tiles and easily transfer between adjoining offices/rooms. Unfortunately in most situations due to the installation of services above the suspended ceiling it is not possible to extend internal walls up to the structural floor/ceiling above or even install a JCW Acoustic Flexible Barrier Curtain. The answer is the installation of JCW Sound Stop Acoustic Pads that simply sit on top of the existing ceiling tiles. The JCW Sound Stop Pads incorporate 2 layers of non-flammable sound absorbing acoustic mineral wool with a mineral loaded sound barrier mat core layer that is encapsulated within an aluminised, non-flammable Class 0 foil. The additional weight of the JCW Sound Stop Pads should not present a problem as to the stability of the ceiling. Acoustic Perimeter Edging Strip ANCILLARY PRODUCTS Datasheet 13 Benefits Easy application into any suspended ceiling system Lightweight solution with easy installation Effective soundproofing FR Class O fire rated foil finish Available in 2 sizes, 600 x 600mm or 1200 x 600 x 50mm Tile sizes: 600 x 600mm & 1200 x 600mm Thickness: nominal 50mm Weight per pad: 600mm x 600mm: 1.9Kg 1200mm x 600mm: 3.8Kg Weight per m 2 : nominal 5.3kg Colour: Silver Fire rating: Class 0 non-flammable Operating temperature: -30ºC to +65ºC. Thermally stable for temperatures up to +93ºC Acoustic performance: Mean average acoustic performance expected 14 db Note: This product is made to order (not held in stock) and should normally be ready within 7 10 working days from acceptance of order. Minimum order quantity may apply, please ask for details. 5mm thick foam strip to isolate acoustic flooring from perimeter walls and maintain the acoustic integrity of the structure. For use with Acoustic Battens, Acoustic Cradles and Acoustic Decks Roll Size: 5mm x 150mm x 50 Lm 100mm & 75mm wide options available L Shaped Strip Size: 2Lmx53mmx23mm pre-formed angle strips Available in 2 metre lengths - 6mm thick Installation Guidance for JCW Sound Stop Acoustic Ceiling Pads Preparation JCW Sound Stop Acoustic Ceiling Pads are designed to be installed on top of existing tiles within a suspended grid type ceiling. Although not heavy, the weight of each pad is equal to 5.3Kg/m 2 so it is important to ensure that the grid system is adequately and securely fixed and supported before installing the acoustic Pads on top. Additional suspension fixings may be required and consultation with the original installers may be worthwhile if there is any doubt. Installation Remove enough of the existing ceiling tiles to gain access to the roof space and then insert each JCW Sound Stop Ceiling Pad through the grid and place on top of adjacent tiles. Continue with this process until the entire ceiling has been covered. When installing the last Sound Stop Pad, place the pad on top of the last of the existing ceiling tiles, then carefully manoeuvre the last tile/ceiling pad into its place within the grid. If cutting of any pad is necessary this can be achieved with the aid of a suitably sized, sharp knife. If much cutting is required; the acoustic mineral wool element of the pad will quickly blunt knives so sharpening will be required on a regular basis. Your ceiling is now acoustically insulated. For best results, the ceilings in all adjoining rooms should be insulated with the JCW Sound Stop acoustic Pads. 34 35

Reflecta Sound SOUND ABSORBERS Datasheet 41 Gym Panel SOUND ABSORBERS Datasheet 36 The Products Decorative fabric covered wall and ceiling panels, specially designed to absorb high levels of reflective noise. Made from dense, sound absorbing mineral fibre board and available in standard Cara and Lucia fabrics which meet the requirements of Class 1 Surface Spread of Flame when tested to BS476:Part7 1997. Thermal conductivity: 0.3 Wm/k@10 C. The Products A high impact resistant acoustic ceiling and wall panel that is both robust and a good sound absorber of reverberant noise because of its high density mineral wool core. Normally fixed at high level to underside of roof or direct to walls and offering significant thermal resistance. Sizes, Colours and Finishes Standard and bespoke sizes available up to a maximum of 3m x 1.2m. Two standard fabric finishes (Cara and Lucia) are available in a wide choice of colours. Client s own fabric can be specified subject to compatibility of sample provided. Various thicknesses available in BS Absorber Classifications from A to D. Reflecta Sound can be customised as an Art Panel using a supplied graphic or photographic image (360DPi recommended) to a maximum size of 1.2m x 2.7m (min order 2 panels or 1m 2 ). Sizes, Colours and Finishes Various sizes and thicknesses available to a maximum 3m x 1.2m, all to BS Absorber Classification A. Standard panels are white, green or grey decorative glass cloth fabric to the front face and non-woven glass tissue to the reverse. Other colours available subject to discussion. Thermal conductivity: 0.6 W/mk @ 10 C. Achieves Euroclass Reaction to Fire Class A2-s1 when tested to BS EN 135-1. Typical Applications Schools, Theatres, Call Centres, Receptions, Conference Rooms, Retails, Public Buildings Typical Applications Sports Halls, Gyms, Changing Rooms, Leisure Halls, Playrooms, School and Village Halls. Techmel Foam SOUND ABSORBERS Datasheet 38 Acoustic Baffles SOUND ABSORBERS Datasheet 50 The Products These panels, made from Melamine Foam, are designed to aid speech intelligibility. Suitable for direct bonding onto well prepared vertical or horizontal surfaces they can also be vertically hung. Sizes, Colours and Finishes Techmel Foam Panels are available in raw form, fabric covered or PVC spray painted. The standard Cara and Lucia fabrics both meet the requirements of Class 1 Surface Spread of Flame when tested to BS476:Part 7 1997. Thermal conductivity: 0.5 W/mk @ 10 C. Standard and Bespoke sizes available to a maximum size of 2.5m x 1.25m. Various thicknesses available all to BS Absorber Classification C. The Products Sound absorbing acoustic baffles designed to achieve a wide range of desired reverberation reduction and aesthetic results. These panels, made from Melamine Foam, acoustic core board or mineral fibre board, are light to handle and effective sound absorbers in large spaces. Sizes, Colours and Finishes Available in a choice of sizes dependent on panel core required. The standard Cara and Lucia fabrics both meet the requirements of Class 1 Surface Spread of Flame when tested to BS476:Part 7 1997. Thermal conductivity: 0.5 W/mk @ 10 C. Various thicknesses available all to BS Absorber Classification C. Typical Applications Schools, Multi-purpose Halls and any large space where reducing reverberation and increasing speech intelligibility is important. Typical Applications Call Centres, Sports Halls, Children s Nurseries, High Hygiene Areas, Industrial and Manufacturing Plant Rooms, Engineering Workshops. 36 37

Acoustic Silent Doors ACOUSTIC DOORS Datasheet & 07 Reflective Sound Screen IDEAL FOR MOST RESIDENTIAL, COMMERCIAL AND INDUSTRIAL REQUIREMENTS (MAX HEIGHT 5M) Absorbent Sound Screen ACOUSTIC FENCING Highly effective sound barrier Available in various heights (max 5m) to suit specific locations. Complies with Highway Works Clause 25 and Highways Sector Scheme 2C. Conforms and tested to BS EN 1793 & BS EN 1794-2 (subject to professional advice). Featured on TV. Robust timber construction Pressure treated for lasting protection Resistant to shrinkage and expansion Capping and counter rail finish Suitable for residential, commercial & industrial applications Datasheet 46 Datasheet 44 Enhanced Acoustic Timber Fencing System Built to Highways Standards and fitted into timber or steel posts. Highly effective sound screens Acoustic Timber Doors Standard: 35 db rated Premium: 44 db rated Range of high performance acoustic timber doors - ideal for apartments, hotels, boardrooms, conference rooms, offices, theatres, cinemas, and music studios. Manufactured to size for a precise fit Wide choice of wood veneer of paint finishes Fire rated with fire and acoustic seals fitted Design and height to suit specific requirements Complies with Highways Sector Scheme 2 Conforms and tested to BS EN 1793. Tested and complies to BS EN 1794-1&2 Meets specification for Highways Works Clause 25 38 39