Ion exchange chromatography

Similar documents
Ion Exchange Chromatography. Teaching Kit Manual. GeNei TM. Cat No. New Cat No. KT Revision No.:

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

G-Sep Ion Exchange Agarose Fast Flow

G-Sep Ion Exchange Agarose Fast Flow

(Refer Slide Time: 00:16)

Chapter 6. Techniques of Protein and Nucleic Acid Purification

G Trap Ion Exchange Selection Kit

Protein Techniques 1 APPENDIX TO CHAPTER 5

Isolation of Protein

Ion Exchange Chromatography. Learning Objectives:

Chapter 1 Principles of ion exchange

Types of chromatography

2 Liquid chromatography of biomolecules

BIOC 463A Expt. 4: Column Chromatographic Methods Column Chromatography

The above media is designed to purify antibodies from aggregates and other impurities.

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

White Paper. Ion Exchange with PureSpeed Tips A Powerful Chromatography Tool

The above media is designed to capture antibodies or other molecules of similar size.

Hydrophobic Chromatography

Protein analysis. Dr. Mamoun Ahram Summer semester, Resources This lecture Campbell and Farrell s Biochemistry, Chapters 5

CM Affi-Gel Blue Gel Instruction Manual. Catalog Number

University of Guelph 3570 Analytical Biochemistry Fall 2004 In-class Quiz #1 Thursday, October 14, 2004 Instructor: Prof. David Josephy Solutions

WorkBeads Protein A INSTRUCTIONS IN

Extracting Pure Proteins from Cells

Red Sepharose CL-6B INSTRUCTIONS

Micro-Elute DNA Clean/Extraction Kit

Purification of oligonucleotides by anion exchange chromatography

TSK-GEL BioAssist Series Ion Exchange Columns

Fast protein separations with ion exchange columns

Q SepFast HighRes. DEAE SepFast TM HighRes S SepFast TM HighRes CM SepFast TM HighRes

Purification of (recombinant) proteins. Pekka Lappalainen, Institute of Biotechnology, University of Helsinki

AFFINITY HIS-TAG PURIFICATION

DEAE Affi-Gel Blue Gel Instruction Manual

Sartobind TM Membrane Adsorbers Discs and Cassettes

PROCEDURE FOR USE NICKEL NTA Magnetic Agarose Beads (5%)

Size Exclusion Chromatography

PLASMID DNA EXTRACTION FROM BACTERIAL CELLS 1

Protein Purification and Characterization Techniques. Nafith Abu Tarboush, DDS, MSc, PhD

PROTEIN L AGAROSE BEADS

G Sep Size Exclusion Columns

Lecture 5: 8/31. CHAPTER 5 Techniques in Protein Biochemistry

Chapter 3. Exploring Proteins and Proteomes. Dr. Jaroslava Miksovska

ION EXCHANGE KIT FOR MAB SEPARATIONS

Nickel-NTA Agarose Suspension

Cellufine MAX Q-r, Cellufine MAX Q-h

TECHNICAL BULLETIN. HIS-Select HF Nickel Affinity Gel. Catalog Number H0537 Storage Temperature 2 8 C

! R f = (dist. traveled by sample)/(dist. to solv. front) ! The closer R f is to 1, the faster the migration

Principles of Gel Filtration Chromatography

Announcements. Next week s discussion will have a quiz on Chapter 3fg and Chapter 11ab Computer Lab (Chapter 11ab): 10/17 10/22

INSTRUCTIONS The resins are adapted to work mainly in native conditions like denaturing.

AFFINITY HIS-TAG PURIFICATION

Why purify proteins?

1. Connect the column to the chromatography system, syringe or pump.

SERVA Ni-NTA Magnetic Beads

Module 16: Gel filtration: Principle, Methodology & applications. Dr. Savita Yadav Professor Department of Biophysics AIIMS, New Delhi

Affinity Chromatography. Teaching Kit Manual. GeNei TM. Cat No. New Cat No. KT Revision No.:

Userguide: SepFast Gel Filtration columns

Next Generation Zirconia-Based Antibody Purification Media

Use Ultra-high Pressure Homogenizer for Cell Rupture to do the disruption, stop cycling the suspension till

Biology 2180 Laboratory # 4 Name. Size Exclusion Chromatography and Microconcentration

NHS-Activated Agarose (Dry Form)

Phenyl Membrane Adsorber for Bioprocessing

Solutions to 7.02 Quiz II 10/27/05

Operating Instructions Heparin Mimetic Affinity

The Agilent 1260 Infinity BioInert Quaternary Pump. Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities

Plus DNA Clean/Extraction Kit

Protein Characterization/ Purification. Dr. Kevin Ahern

Protein Structure and Function! Lecture 4: ph, pka and pi!

Phenyl Membrane Adsorber for Bioprocessing

ProteIndex Chemical-Tolerant Ni-Penta Agarose. Prepacked Cartridge. 6 FF Prepacked Cartridge, 5 x 1 ml settled resin

Lecture 8: Affinity Chromatography-III

Vivapure Ion Exchange Chromatography Products

Size Exclusion Chromatography

CX-1 ph Gradient Buffer

Sartobind IEX nano 3 ml

Computer Software Virtual Protein Purification: A Simple Exercise to Introduce ph as a Parameter that Effects Ion Exchange Chromatography ws

Application Manual ProteoSpin Abundant Serum Protein Depletion Kit

Code No. Designation Type of Gel No. supplied Connectors Description Column

Phenyl Sepharose CL-4B

! R f = (dist. traveled by sample)/(dist. to solv. front) ! The closer R f is to 1, the faster the migration

Capture of mouse monoclonal antibodies

BabyBio S BabyBio Q BabyBio DEAE

Principles of Gel Filtration Chromatography

Production of FITC conjugate

AFFINITY HIS-TAG PURIFICATION

ProteoEnrich CAT-X SEC Kit Merck: Lichrospher Composition. Silica Particle size. 25 µm particles with 6 nm pore size Ligand SO 3

GST Fusion Protein Purification Kit

TECHNICAL BULLETIN. Ni-CAM HC Resin High Capacity Nickel Chelate Affinity Matrix. Product No. N 3158 Storage Temperature 2 8 C

TOYOPEARL GigaCap Series

INSTRUCTION IN

G-Sep Ni-NTA Agarose Fast Flow

Rhinophase -AB, Zirconia-based Monoclonal Antibody Purification System

Gelatin Sepharose. instructions

E.Z.N.A. Soil DNA Kit. D preps D preps D preps

Gel Filtration Chromatography. Teaching Kit Manual. GeNei TM. Cat No. New Cat No. KT Revision No.:

His-Spin Protein Miniprep

G-Sep IDA Agarose Fast Flow

Transcription:

Ion exchange chromatography

Objectives: 1- The objective of this experiment is to learn the principles of ion exchange chromatography by separating the charged molecules using buffer and salt. 2- A practical experience on ion exchange chromatography in the laboratory 3- Importance of ion exchange chromatography and procedures in purification.

Protein Isolation and Purification Protein purification is a series of processes intended to isolate one or a few proteins from a complex mixture, usually cells, tissues or whole organisms. Whole Tissue Tissue homogenization Cell debris and other proteins are removed by centrifugation and other protein could be removed by salting out You will have a mixture of proteins that have different charges, Sizes, and other properties Gel filtration chromatography You will have a mixture of proteins that have ionizable molecule similar Sizes,

Ion exchange chromatography Ion exchange chromatography involves the separation of ionizable molecules based on their total charge. This technique enables the separation of similar types of molecules that would be difficult to separate by other techniques because the charge carried by the molecule of interest can be readily manipulated by changing buffer ph.

Ion exchange chromatography Separate molecules according to charge; actually other features of the molecule are usually important so that the chromatographic behavior is sensitive to the charge density, charge distribution.

Types of ion exchanger chromatography A cation exchanger: Have negative charge and exchanges cations An anion exchanger: Have positive charge and exchanges anoins Ion exchange chromatography is a type of adsorption chromatography Charged molecules adsorb to ion exchangers reversibly so, the molecules can be bounded or eluted by changing the ionic environment.

Stationary Phase Stationary phase material is a resin or gel matrix beads with covalently bonded charged functional groups. [differ from gel filtration chromatography]. harged molecules (including proteins) bind electrostatically (non covalently) to oppositely charged groups of (stationary phase) that have been bound covalently on the matrix (support). - - Target molecule - - + + + + support Stationary phase

- Target molecule - - - + + + + support Stationary phase 1-Support(inert): materials that can be used are dextran, cellulose, and agarose. 2-Stationary phase: is the charged groups which bound covalently to support, Anion exchangers have positive charge group: such as diethylaminoethyl (DEAE), DEAE: matrix-ch2-ch2-n+h(ch2ch3) Cation exchanger have negative charge group: such as carboxymethyl group(cm) CM: matrix- CH 2 COO - 3-mobile phase: buffer or salt

How to choose the suitable ion exchanger To choose whether the ion exchanger is to be anionic or cationic depend on the material to be separated. If the material to be bound to the column have a single charge (i.e., either plus or minus), the choice is clear.

How to choose the suitable ion exchanger However, many substances (e.g., proteins), carry both negative and positive charges and the net charge depends on the ph. Net charge is positive Net charge is zero Net charge is negative

How to choose the suitable ion exchanger In such cases, the primary factor is the stability of the substance at various ph values. Most proteins have a ph range of stability (i.e., in which they don t denature) in which they are either positively or negatively charged. So, if a protein is stable at ph value above the isoelectric point, an anoinic exchanger should be used; but if stable at values below the isoelectric point, a cation exchanger is required. Some proteins are stable both above and below their pi. These proteins can be purified with either an anion or cation exchanger.

How to choose the suitable ion exchanger Also, make sure that the targeted protein that you want to be separated have different charge from other proteins Thus, if a protein has a negative net charge at a given ph, an anion exchange matrix should be used for its purification.

How to choose the suitable ion exchanger http://www.bio-rad.com/en-ca/applications-technologies/liquid-chromatography-principles/ionexchange-chromatography

Molecules Separation using ion exchanger chromatography Separation on ion exchangers is usually accomplished in two stages: First, the substances to be separated are bound to the exchanger by using conditions that give stable and tight binding also unwanted materials should have different charge if possible. Second, the target molecule then must be eluted (dissociated) either by: 1. By applying ionic strength(eg,nacl) so that there will be competition between the salt and target protein to bind with stationary phase 2. Or by changing ph so the charge of the protein will change

1-Example for elution of the analyte by using salts (increase ionic strength): -In cation exchange chromatography, to elute the positively charged analyte we could elute the positively charged analyte by the addition of NaCl. -The sodium ions[+] of NaCl, will compete with the analyte[+] to bind to the charged stationary phase[-]. -This will cause the elution of the analyte from the column.

2-Elution of the analyte by using buffers: at a given ph a protein will possess an overall net charge. -At ph of buffer lower than pi of the analyte, the net charge will be more positive. -At ph of buffer higher than pi of the analyte, the net charge will be more negative. So, we can change the net charge of the analyte in a way that it will elute from the column if it has the same charge of the stationary phase, by using the suitable ph of the buffer and knowing the pi of the analyte. Or by using buffer has ph that will cause the net charge of the analyte equal to zero[no charge], leading to the analyte to be eluted.

Practical

Practical: -You are provided with Cation exchange chromatography column, separate the sample given to you. -The sample is a mixture of two proteins, myoglobin and cytochrom C,[pI=7.2 and 10.2 respectively] dissolved in phosphate buffer[ph=8]. Separate the mixture by using the buffer and 1M NaCl. 1-carefully remove the layer of the phosphate buffer from above the resin using a pasture pipette, and let only a very thin layer of buffer. 2- Again using the pasture pipette, very slowly layer the sample mixture solution on the top of the resin, by adding the tip of pipette on the wall of column. Care should be taken not to disturb the gel beads. 3- Open the screw clip, and start to collect the fractions of about 3 ml each. 4- After the sample mixture penetrates the gel so that you can see the gel beads, carefully fill up the column with the phosphate buffer [ph=8], and complete the collection of fractions. 5-Collect the fraction of the first sample, and make sure that it is completely eluted.

6-start adding the 1M NaCl to elute the second sample, and collect the fraction, then make sure that it is eluted completely. 7- Read the absorbance of each fraction at 410 nm by using spectrophotometer using phosphate buffer as blank for the fractions was collected by using the buffer to elute them, and use 1 M NaCl as a blank for the fractions was collected by using the salt. 8-plot the curve[absorbance at 410nm against fraction number].

http://www.bio-rad.com/en-ca/applications-technologies/liquid-chromatography-principles/ionexchange-chromatography