RECOMMENDED APPLICATION INSTRUCTIONS FIRE RETARDANT COATINGS FOR CABLES AND FIRE RESISTANT BARRIERS FOR SERVICE PENETRATION SEALS

Similar documents
FIRESTOPPING & SMOKE SEALS

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

FireX Fire Stopping Mastic FM

ASF FR Board PRO RANGE Coated Mineral Wool Board for the Professional

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Use of Coatings to Improve Fire Resistance of Wood

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

Pacific Polymers Elasto-Deck 5000MR Guide Specification

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

Division 15 INSULATION Section 15100

ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT

ROCKWOOL ABLATIVE COATING Improves the fire resistant properties for ROCKWOOL stone wool slabs

AESTUVER fire-protection mastic For the AESTUVER expansion joint M

The Proven Solution Panel Seal Single and double panel penetration seals for cables

Normal, Medium And High Density Fireproofing Materials

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

FIRE STATION 55 June 14, 2010

FlexiCoat-MAK. Technical Data Sheet

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

DATASHEET: FIRECUT F-1 (EXTERIOR) SPRAY-APPLIED FIRE RESISTIVE MATERIALS

PROJ. NO SECTION HVAC DUCT INSULATION

FIRE RESISTANT MORTAR - Installation Guide

EPSILON EM-SILPROCOAT RTV ANTI-CORROSION RUBBER COATING TECHNICAL DATASHEET & SPECIFICATIONS

AquaFlash System Installation Guide

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

PRODUCT DATA SHEET Sika Unitherm Platinum

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

FIRESTOP AND FIRE PROTECTION

AquaFlash System Installation Guide DS196

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS

SECTION SPRAY FOAM INSULATION

Membryl UV stable waterproofing membrane.

Fire stop barriers FIRE - STOP. Fire stop barriers

Fire stop barriers FIRE - STOP. Fire stop barriers

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

Mapetherm AR1 Light. Lightweight one-component cementitious mortar FOR THERMAL INSULATION WITH SUPERIOR LIGHTNESS AND ASTONISHING PERFORMANCE

TECHNICAL DATA SHEET ASMACO INTUMESCENT ACRYLIC SEALANT

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION DIVISION: AIR BARRIERS REPORT HOLDER:

Originally Issued: 04/17/2015 Valid Through: 04/30/2016

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

St. Monica Food Pantry

FirePillow-240. Temporary or permanent fire barriers for all types of penetrations and services Approved to AS Technical Data Sheet

A. Source Limitations: Obtain each type of building insulation through one source.

Fire Protection Products

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC. EVALUATION SUBJECT:

Intertek Research Report IRR-1011

JAN Firestopping Standard Details

Firebreak 22 Fire Resistant Acoustic Sealant. Rigid (concrete) floors of 150mm minimum thickness

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

SECTION (07100) - DAMPPROOFING AND WATERPROOFING

3M Fire Barrier Sealant IC 15WB+

PRODUCT DATA SHEET. UrePac Rigid 6 9

Promat PROMASEAL Fire Barrier

PRODUCT DATA SHEET Sika Unitherm Platinum-120

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Perimeter Fire Containment

National Occupational Standards Developer s pack for Passive Fire Protection (Construction)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

CS-195+ Composite Sheet FR Board

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Hygiene and Waterproofing Solutions FLAMELOCK

Fire-Rated Bulkhead Batt

CERTIFICATE OF APPROVAL No CF 5034 FISCHERWERKE GMBH & CO. KG.

Originally Issued: 2/12/2016 Revised: 07/28/2017 Valid Through: 2/28/2018

Firestop and Fire Protection Systems

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Fire Protection Products

INSTALLATION GUIDE SPECIFICATION

Addendum to Specifications

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

UBC Technical Guidelines Section Edition Thermal Insulation for Piping Page 1 of 5

SECTION PIPING INSULATION

Managing Vertical Fire Spread in Multi-Story Buildings Through Effective Perimeter Fire Barrier Systems

International Fireproof Technology Inc.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BAYER MATERIALSCIENCE, LLC

International Fireproof Technology Inc.

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

SECTION SPRAY FOAM INSULATION

PERM-A-BARRIER NPS Detail Membrane

FIRESTOP SUBMITTAL PACKAGE

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

HPW Protocol Reference Manual

ROCKGRIP UNIVERSAL ACRYLIC PVA

SECTION (07810) - APPLIED FIREPROOFING

Pacific Polymers Elasto-Deck BT Guide Specification

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

FireShield Restoration Specifications - EPDM

Coating A tough, permanent, non-intumescent fire protective coating for electrical cables and penetration seals.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER: DAP FOAM, INC.

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE

3M Fire Barrier Mouldable Putty

Transcription:

RECOMMENDED APPLICATION INSTRUCTIONS FIRE RETARDANT COATINGS FOR CABLES AND FIRE RESISTANT BARRIERS FOR SERVICE PENETRATION SEALS

The below is a recommendation of application area s for the fire protection of electrical cables and service penetration seals in order to minimize the damage to the industrial complex, where it will be used. MICON FLAMSAYF 325 Micon FLAMSAYF 325 is a fire retardant mastic (coating) with excellent insulating properties designed to stop fire propagation along electrical cables. Micon FLAMSAYF 325 is also used in the construction of passive fire protection of cable/service penetration seals to prevent the spread of flame and toxic gases through service openings. Micon FLAMSAYF 325 - tested by the C.S.I.R in accordance with the requirements and of S.A.B.S and Anglo American Specifications - excellent insulation properties - excellent adhesion to P.V.C cables - FLAMSAYF 325 seals can be specified for a fire resistance rating of 2 hours with only a 100mm depth - FLAMSAYF 325 seals are easily modified to accommodate changes in services - FLAMSAYF 325 seals are simple to install to suit any opening - FLAMSAYF 325 is environmentally acceptable and safely used in confined spaces DESCRIPTION FLAMSAYF 325 is a fire retardant mastic applied in a 1.6mm layer to the surface of all cables requiring fire protection. FLAMSAYF 325 seals consists of two 50mm layers of mineral wool coated with FLAMSAYF 325 (1.6mm dft) on both sides APPLICATION FLAMSAYF 325 mastic can be effectively applied by trowel, brush or hand to the surface of P.V.C armoured cables to a minimum thickness of 3mm to provide suitable protection. FLAMSAYF 325 seals can be easily installed to allow flexibility in design for the addition of cabling or services to be installed at a later stage. This seal comprises of 100mm high-density mineral wool board, which is a non-combustible material easily compressed into difficult openings, coated on both sides with a 3mm trowelled on layer of FLAMSAYF 325. Any cables penetrating the seal are similarly coated for a distance of 500mm of either side of the seal. All surfaces to be protected with FLAMSAYF 325 must be free from dust, grease, rust, grime, and loose paint.

ENVIRONMENT Micon FLAMSAYF 325 is an environmentally acceptable product that can be safely applied in confined spaces. ACTION IN FIRE When used as a cable protection system, Micon FLAMSAYF 325 forms a protective insulating char on exposure to heat with zero spread of flame and low toxic gas emissions. On exposure to fire the FLAMSAYF 325 seal retains its integrity, prevents smoke leakage and limits transfer of heat along cables through the seal well within the test requirements. FIRE TEST REPORTS FLAMSAYF 325 seal FIRE PROPERTIES TEST METHODS S.A.B.S 0177 Part II - Spread of flame index 0 - Heat contributed index 0 - Smoke emitted index 0,95 - Surface fire index 0,32 - Overall classification Class 2 - Fire resistance rating 2 Hours tested by the C.S.I.R report # BF 501/040 5600 5664021996 MICON FLAMSAYF 325 FIRE PROPERTIES TEST METHOD - Fire insulation properties AAC Specification 164/23 - Toxicity of combustion gases NES 713 - Spread of flame index 0 S.A.B.S 0177 Part III - Heat contributed index 0 S.A.B.S 0177 Part III - Smoke emitted index 0,95 S.A.B.S 0177 Part III - Surface Fire Index 0,32 S.A.B.S 0177 Part III - Overall classification Class 2 S.A.B.S.0177 Part III tested by the C.S.I.R report # BF 502/003 5600566041996

PHYSICAL PROPERTIES Density +- 1,35g/p/m³ Flexibility excellent Viscosity +70 000CPS Brookefield Viscometer 6/10 Solids 63% Toxicity water based (non-toxic) Flash Point n/a Shelf Life 18 months when stored in original containers at room temperature Spread Rate 4kg/m² to give (dft) of 1.6mm DFT recommended 1.6mm Drying Time touch dry 3 hours, full cure in 3 days

Application of Micon Flamsayf 325 to Electrical Cables Micon Flamsayf 325 is a Non-Intumescent type product used for interior and exterior application and is ideal as a cable coating, to prevent the propagation of flame spread along the cables. Micon Flamsayf 325 is flexible and adheres excellently to all electrical cable surfaces and does not give off harmful gasses when exposed to fire. Micon Flamsayf 325 was developed to be used in areas where it is virtually impossible to apply a three-coat system for one reason or another. Application to Electrical Cables Micon Flamsayf 325 can be applied to a dry film thickness of 1.5mm - 2mm, in a one coat application provided care is taken during application. As with Micon Intusayf the areas to be coated must be free from dust, oil, grease etc. Micon Flamsayf 325 is flexible when dry and therefore excellent for use on electrical cables. Micon Flamsayf 325 is non-toxic and can be applied by brush, trowel, or hand. Micon Flamsayf 325 is also used in the construction of Fire Penetration Seals for use in areas like substations to seal areas where cables pass through Fire Walls. Micon Flamsayf 325 complies with the SABS 0177 Part 111 standards and has also been extensively tested by the CSIR. Action in fire Micon Flamsayf 325 forms a protective insulating char on exposure to fire with a zero spread of flame and acceptable low toxic gas emissions. COVERAGE FOR CABLE COATING MICON FLAMSAYF 325 (1 coat 1.6mm D.F.T.) - + 4.00 kg per m2

The below is just a guideline of instruction, and should not be used as the only line of defense in event of an outbreak of fire. Cable Coatings All cable surfaces should be clean and free from dust, dirt, grime and grease prior to the application of Micon Flamsayf 325. It is the responsibility of the contractor to ensure that proper surface preparation is conducted to ensure that the fire retardant will work as intended in event of fire. All cables to be coated, irrespective of their size, shall be coated with a Micon Flamsayf 325 fire retardant mastic coating to a minimum W.F.T thickness of 3mm with a minimum D.F.T thickness of 1.6mm. Any cables entering/leaving a wall or penetration should be coated both sides of the wall to a length of 1 meter on both sides with Micon Flamsayf 325 Cable termination of transformers shall be coated from the termination point two meters from the termination with Micon Flamsayf 325. Cables and terminations of MCC s HV switchgear shall be coated from the termination point two meters from the termination with Micon Flamsayf 325. Cables and terminations of HV motors, shall be coated from the termination point two meters from the termination with Micon Flamsayf 325. Horizontal cables which run on exposed cable racks in areas considered as high risk should be coated in lengths of two meters every twenty meters Vertical cables which run on exposed cable racks in areas considered as high risk should be coated in lengths of two meters at vertical branch off and then at intervals of every five meters Cables of less than three meters shall be coated for the entire length. Cables connected to a gulley box rig shall be coated from the termination point five meters from the termination.

SPECIFICATIONS FOR THE INSTALLATION OF A MICON FLAMSAYF 325 MASTIC PENETRATION SEAL Purpose To provide a one or two hour fire and/or smoke seal Area s of application 60 minute rating (ref Figure 1) Pre-coat a single layer of 50mm thick, 160kg/m³density mineral wool board on one side with Micon Flamsayf 325 mastic to a dry film thickness of 1.6mm The board is then cut oversized and pressure fitted into the opening with the precoated side to the inside. The exposed surface coat with Micon Flamsayf 325 mastic to dry film thickness of 1.6mm Micon Flamsayf mastic is then applied to the service penetrating the fire seal for a distance of 500mm from the seal unless it is a steel pipe duct in which case the overlap should be 40mm. Micon Flamsayf 325 mastic is applied to overlap from the mineral wool board to the adjacent substrate for a distance of 25mm on both sides of the fire seal to provide an airtight seal.

120 minute rating (ref Figure 2 and 3) The only difference between a 60 minute and a 120 minute fire penetration seal is that a double layer of 50 mm mineral wool board is installed in place of a single layer, otherwise installation procedures are the same as above. Reinforcing On larger openings a combination of angle iron and expanded metal may be used to provide stability to the mineral wool board. Fire protective Coating for Cables and Fire Resistant Barriers for Cable Trenches and Wall Penetrations Cables connected to a mini substation must be protected with Micon Flamsayf 325 from the termination point to within a radius of approximately 5 meters from the centre of the mini-sub. All cable joint shall be coated for approximately 1 meter on either side of the joint with Micon Flamsayf 325.

Fire Barriers for Wall Penetrations Fire barriers for wall penetrations shall be installed for cable openings in all outside walls of all substations as well as selected penetrations into other areas. Insulation board mineral wool 1m x 600mm x 50mm. All wall penetrations in buildings shall be fully packed with mineral wool, and sealed with a fire protective coating. The nominal dry thickness shall be 3mm (minimum 2mm). The coating shall be extended through to cover all cables entering and/or leaving the wall penetration up to a minimum length of 1meter on both sides of the wall. Fire Barriers in Cable Trenches/Ducts Where cables are run in trenches/ducts longer than 15 meters, a 50mm thick mineral wool board must be installed every 10 meters and must be effectively sealed with additional mineral wool and fire protective coating to fill any voids. All cables shall be coated on both sides of the barrier up to a minimum length of 2 meters. Fire barriers shall also be placed where cables branch off from a main trench/duct.