DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: SRL INDUSTRIES LTD.

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: CONCRETE SECTION: PRECAST STRUCTURAL CONCRETE REPORT HOLDER: SUPERIOR WALLS OF AMERICA, LTD.

(800) (562) A Subsidiary of the International Code Council

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PJ S REBAR INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: TENDON SYSTEMS, LLC

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

REPORT HOLDER: OLMAR SUPPLY INC RESEARCH DRIVE LIVERMORE, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: CONCRETE SECTION: MAINTENANCE OF CONCRETE REPORT HOLDER: STRUCTURAL TECHNOLOGIES, LLC

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION DIVISION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SPRAY FOAM POLYMERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS SECTION: PRECAST STRUCTURAL CONCRETE SECTION: SITE CAST CONCRETE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: SUPERFORM PRODUCTS LTD. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER: DAP FOAM, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: BARSPLICE PRODUCTS INC WEBSTER STREET DAYTON, OHIO

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: MMFX TECHNOLOGIES A COMMERCIAL METALS COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ELASTOCHEM SPECIALTY CHEMICALS, INC.

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: INTEPLAST GROUP CORPORATION EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: TEKNION LIMITED

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Trusted ICC ES MILAN ITALY SYSTEMS. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD. EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: POST-TENSIONED CONCRETE REPORT HOLDER: GENERAL TECHNOLOGIES, INC.

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

Transcription:

0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-2037 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 03 00 00 CONCRETE SECTION: 03 37 00 SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A. VIA TONIOLO 39/B Z.I. BELLOCCHI, 61032 FANO (PU) ITALY EVALUATION SUBJECT: EMMEDUE WALL, FLOOR AND ROOF PANEL Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2016 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2037 Reissued July 2016 This report is subject to renewal July 2018. A Subsidiary of the International Code Council DIVISION: 03 00 00 CONCRETE Section: 03 37 00 Specialty Placed Concrete REPORT HOLDER: EMMEDUE S.P.A VIA TONIOLO 39/B Z. I. BELLOCCHI 61032 FANO (PU) ITALY (0039) 0721 855650 www.mdue.it info@mdue.it EVALUATION SUBJECT: EMMEDUE WALL, FLOOR AND ROOF PANEL 1.0 EVALUATION SCOPE Compliance with the following codes: 2012 and 2009 International Building Code (IBC) 2012 and 2009 International Residential Code (IRC) 2013 Abu Dhabi International Building Code (ADIBC) The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: Structural Surface-burning characteristics Fire resistance Weather resistance Physical properties 2.0 USES Emmedue wall, floor and roof panels are used as structural composite panels for load-bearing and nonload-bearing concrete walls, and reinforced concrete floor and roof panels in fire-resistance-rated and non-fire-resistancerated construction. The Emmedue panels are recognized for use in buildings of noncombustible construction when installed in accordance with Section 4.2 of this report. 3.0 DESCRIPTION 3.1 General: The Emmedue panels consist of a single insulating foam plastic board with a grid of welded wire reinforcement on each face of the insulating panel connected by steel transverse wires. A layer of Shotcrete is applied to each face of the wall panels, over the welded woven steel, at the jobsite. Emmedue wall panels are designated PSM80 and consist of 4-inch-thick (102 mm) EPS foam cores with 1-inch-thick (25.4 mm) Shotcrete on each outer face. The Emmedue floor-roof panels consist of an insulating foam plastic board with a layer of welded wire reinforcement on each face and a grid of welded wire reinforcement connected by steel transverse wires. The bottom of the floor-roof panels is shot with a layer of Shotcrete at the jobsite. The top of the floor-roof panels is covered with a layer of placed concrete at the jobsite. Emmedue floor-roof panels are designated PSS80 or PSS150 and consist, respectively, of 4-inch-thick (102 mm) or 6-inch-thick (152 mm) EPS foam cores, with 2 inches of concrete on the top surface and 1-inch (25.4 mm) Shotcrete on the bottom surface. The Emmedue wall panels and floor-roof panels are preformed and delivered to the jobsite for erection and placement of Shotcrete and concrete. 3.2 Materials: 3.2.1 EPS: The insulation used in the Emmedue wall, floor and roof panels is expanded polystyrene (EPS) foam plastic boards manufactured from EPS beads recognized in ICC-ES ESR-1798. The EPS is Type I EPS with a minimum density of 0.90 pcf (14.4 kg/m 3 ), a flame-spread index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E84 at a 4-inch (102 mm) thickness and a 1.0 pcf (16.0 kg/m 3 ) maximum density. 3.2.2 Reinforcement: Deformed steel reinforcement bars must have a minimum yield stress of 60 ksi (420 Mpa) and comply with Section 3.5.3.1 of ACI 318 and IBC Section 1903. Welded plain wire reinforcement must comply with Section 3.5.3.5 of ACI 318 and IBC Section 1903. The wire used in the fabrication of the welded wire reinforcement and the steel transverse wire conforms to ASTM A82. The welded wire reinforcement complies with ASTM A185. 3.2.3 Concrete: Concrete must be normal-weight concrete, complying with the applicable code, having a maximum aggregate size of 5 / 8 inch (16 mm), a minimum slump of 2 inches (51 mm), and a minimum compressive strength of 2,500 psi (17.2 MPa) [minimum of 24 MPa is required under ADIBC Appendix L, Section 5.1.1] at 28 days. The concrete must comply with Chapter 19 of the IBC. 3.2.4 Shotcrete: Shotcrete must comply with IBC Section 1913 and have a minimum specified compressive strength of 2,500 psi (17.2 MPa) [minimum of 24 MPa is required under ADIBC Appendix L, Section 5.1.1]. Aggregate size must not exceed 3 / 8 inch (9.5 mm) and conform to Gradation No. 1 of Table 2.1 of ACI 506R-90. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 8 1000

ESR-2037 Most Widely Accepted and Trusted Page 2 of 8 4.0 DESIGN AND INSTALLATION 4.1 Design: Concrete walls, floors and roofs formed by the Emmedue system must be designed and constructed in accordance with Chapters 16 and 19 of the IBC. The design loads for walls and floors must not exceed the allowable loads set forth in Tables 1 and 2 of this report. For each project, plans, specifications, and structural calculations must be submitted to the building official for approval, and must show particular job details relating to design and construction. The calculations must be based on loads and loading conditions as required in the IBC. To ensure structural integrity, the Emmedue system must be subjected to a structural analysis, prior to construction, conducted by registered design professionals trained and certified by Emmedue. The structural analysis must be used to determine structural capacities for all portions of the Emmedue system. 4.2 Fire-resistive-rated Assemblies: Wall panels constructed with up to 4-inch-thick (102 mm) EPS board cores and 1 3 / 4-inch-thick (44 mm) Shotcrete on each face have a one-hour fire resistance rating. The maximum allowable axial compressive load is 2,840 plf (41.5 kn/m), exclusive of the weight of the wall panel. Floor-roof panels with a minimum concrete thickness of 1 inch (25.4 mm) on the underside and 2 inches (51 mm) on the topside have a one-hour fire-resistance rating when tested in accordance with ASTM E119. For applications on buildings of any height, floor-to-wall intersections must be fireblocked in accordance with the applicable code to prevent the passage of flame, smoke and hot gases from one story to another. The foam plastic insulation must not be continuous from one story to another. 4.3 Installation: Foundation walls, footings, and other supporting structures receiving Emmedue panels must be level and free of dirt and loose material. Reinforcement for anchoring panels to support must be as shown on the plans. The Emmedue panels are installed and aligned in accordance with the plans. After alignment, Shotcrete concrete complying with Section 3.2.4 of this report is applied to the welded wire reinforcement. The Shotcrete concrete must be applied to the outside and inside of the Emmedue wall panels and to the underside of the floorroof panels to the thickness shown on the plans. The exterior and interior concrete must be applied by the Shotcrete process, using either the dry or wet process in accordance with the provisions of the Guide to Shotcrete (ACI 506R-90) and the Specification for Shotcrete (ACI 506.2-95). Shotcrete application must comply with Section 1913 of the IBC. The Shotcrete cover over the wall panel welded wire reinforcement must not be less than 1 inch (25.4 mm) in thickness, with a minus tolerance of 1 / 4 inch (6.4 mm). 4.4 Special Inspection: Special inspection of Shotcrete must be in accordance with Table 1705.3 and Section 1910.10 of the 2012 IBC, or Table 1704.4 and Section 1913.10 of the 2009 IBC. Continuous inspection of poured concrete must be in accordance with Section 1704.4 of the IBC. 5.0 CONDITIONS OF USE The Emmedue wall, floor and roof panel systems described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation complies with this report, the manufacturer s published installation instructions and the applicable code. In the event of a conflict between the manufacturer s published installation instructions and this report, this report governs. 5.2 The structural concrete wall systems recognized in this evaluation report, when used as seismic force resisting systems, must be limited to Seismic Design Category A or B under the IBC or IRC. 5.3 Installation of elements requiring special inspection under the IBC must comply with Section 4.4 of this report. 5.4 The panels are manufactured in Schieppe di Orciano, Italy, with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Concrete Floor, Roof, and Wall Systems and Concrete Masonry Wall Systems (AC15), dated February 2010, editorially revised December 2012. 7.0 IDENTIFICATION The Emmedue panels are labeled with the Emmedue name, address, manufacturing address, and evaluation report number (ESR-2037).

ESR-2037 Most Widely Accepted and Trusted Page 3 of 8 TYPE OF LOADING Axial Compression Transverse for Deflection Limit L / 120 Transverse for Deflection Limit L / 180 Transverse for Deflection Limit L / 240 Transverse for Deflection Limit L / 360 Combined Axial and Transverse for Deflection Limit L / 120 Combined Axial and Transverse for Deflection Limit L / 180 Combined Axial and Transverse for Deflection Limit L / 240 Combined Axial and Transverse for Deflection Limit L / 360 TABLE 1 ALLOWABLE WALL PANEL LOADS TYPE OF PANEL For SI: 1 inch = 25.4 mm, 1 lb/ft = 14.6 N/m, 1 psf = 47.9 Pa. PANEL HEIGHT (ft) AXIAL COMPRESSIVE LOADS (Pounds per linear foot) TRANSVERSE LOADS (Pounds per square foot) PSM80 8 7750 --- PSM80 10 7810 PSM80 12 7880 PSM80 14 7940 --- PSM80 8 --- 223 PSM80 10 --- 177 PSM80 12 --- 131 PSM80 14 --- 86 PSM80 8 --- 190 PSM80 10 --- 153 PSM80 12 --- 115 PSM80 14 --- 78 PSM80 8 --- 173 PSM80 10 --- 140 PSM80 12 --- 107 PSM80 14 --- 74 PSM80 8 --- 120 PSM80 10 --- 103 PSM80 12 --- 87 PSM80 14 --- 71 PSM80 8 11000 178 PSM80 10 11180 143 PSM80 12 11350 107 PSM80 14 11530 71 PSM80 8 11000 130 PSM80 10 11180 106 PSM80 12 11350 82 PSM80 14 11530 57 PSM80 8 11000 106 PSM80 10 11180 87 PSM80 12 11350 69 PSM80 14 11530 50 PSM80 8 11000 82 PSM80 10 11180 69 PSM80 12 11350 56 PSM80 14 11530 44 TABLE 2 ALLOWABLE WALL PANEL RACKING SHEAR LOADS TYPE OF LOADING TYPE OF PANEL PANEL HEIGHT (ft) RACKING SHEAR LOAD (Pounds per linear foot) DEFLECTION (inch) PSM80 8 770 0.06 Racking Shear PSM80 10 840 0.16 PSM80 12 910 0.25 PSM80 14 980 0.35 For SI: 1 inch = 25.4 mm, 1 lb/ft = 14.6 N/m, 1 psf = 47.9 Pa.

ESR-2037 Most Widely Accepted and Trusted Page 4 of 8 TYPE OF LOADING Transverse for Deflection Limit L /120 Transverse l for Deflection Limit L /180 Transverse for Deflection Limit L /240 Transverse for Deflection Limit L /360 TABLE 3 ALLOWABLE ROOF, FLOOR PANEL LOADS TYPE OF PANEL For SI: 1 inch = 25.4 mm, 1 lb/ft = 14.6 N/m, 1 psf = 47.9 Pa. SPAN (ft) AXIAL COMPRESSIVE LOADS (Pounds per linear foot) TRANSVERSE LOADS (Pounds per square foot) PSS80 8 --- 304 PSS80 12 --- 119 PSS150 8 --- 345 PSS150 12 --- 135 PSS80 8 --- 254 PSS80 12 --- 101 PSS150 8 --- 274 PSS150 12 --- 110 PSS80 8 --- 229 PSS80 12 --- 91 PSS150 8 --- 238 PSS150 12 --- 98 PSS80 8 --- 203 PSS80 12 --- 82 PSS150 8 --- 202 PSS150 12 --- 85 TABLE 4 ALLOWABLE ROOF, FLOOR PANEL DIAPHRAGM SHEAR LOAD TYPE OF LOAD TYPE OF PANEL SPAN (ft) DIAPHRAGM SHEAR LOAD (Pounds per linear foot) DEFLECTION AT ALLOWABLE SHEAR LOAD Diaphragm Shear PSS80 8 430 0.17 For SI: 1 inch = 25.4 mm, 1 lb/ft = 14.6 N/m, 1 psf = 47.9 Pa. Note: Electro-welded cross steel wire are at a ratio of 82 welds per 10.76 sq/ft FIGURE 1 TYPICAL INSTALLATION DETAILS

ESR-2037 Most Widely Accepted and Trusted Page 5 of 8 GENERAL DETAILS Note: (*) to be design by engineer of records PANEL TO PANEL CONNECTION/JOINT Note: (*) to be design by engineer of records FIGURE 1 TYPICAL INSTALLATION DETAILS (Continued)

ESR-2037 Most Widely Accepted and Trusted Page 6 of 8 TYPICAL TYPES OF MESH USED FOR REINFORCEMENT/CONNECTION WALL PANEL TO WALL PANEL CORNERS CONNECTIONS Note: (*) to be designed by engineer of records FIGURE 1 TYPICAL INSTALLATION DETAILS (Continued)

ESR-2037 Most Widely Accepted and Trusted Page 7 of 8 WALL PANEL TO FOUNDATION CONNECTION EXTERIOR WALL PANEL TO FLOOR/ROOF PANEL CONNECTION FIGURE 1 TYPICAL INSTALLATION DETAILS (Continued)

ESR-2037 Most Widely Accepted and Trusted Page 8 of 8 WALL PANEL TO FLOOR/ROOF PANEL CONNECTION Note: (*) to be designed by engineer of records WALL PANEL TO ROOF PANEL CONNECTION FIGURE 1 TYPICAL INSTALLATION DETAILS (Continued)