Module 8: Ontario Building Code Fire and Spatial Separations

Similar documents
Building Codes and Ordinances ARC 227

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

2015 IBC Exit Systems

BUILDING CODE COMMISSION

Excerpts from the Uniform Building Code. (UBC) For The US

2012 IBC Exit Systems

General Building Information

NEWS LETTER MARCH 27, 2009

First Revision No NFPA [ Section No ]

VERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

FS , 712, 713, 714

E?? , , , , , , , , , , , , Table ,

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

The Building Codes A.R.E. Building Design and Construction Exam Prep

WON-DOOR CORPORATION Won-Door FireGuard Applications

How to Prepare Your LSE Report

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

2012 IBC Inspection of Fire-resistance Rated Walls

LEAD DESIGN PROFESSIONAL:

Advanced Studies of the International Building Code. Presented by Steve Thomas, Colorado Code Consulting, LLC

What is a Won-Door FireGuard Door?

Comparison of the life safety elements of the 1997 UBC and the IBC 2000.

The Lexington Division of Fire and Emergency Services. Fire Chief Robert G. Hendricks

Applying the Building Code During Design

HOUSING CONVERSION Guidelines for the conversion of a house to commercial use.

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

Company Overview. Significant Code Changes Massachusetts State Building Code 9 th Edition (2015 International Code)

FIRE-RESISTANCE-RATED CONSTRUCTION

BUILDING CODE COMMISSION

Document G808. Project Data CONSTRUCTION DOCUMENTS DATE IDENTIFICATION DESIGN DEVELOPMENT DATE IDENTIFICATION INITIAL INFORMATION DATE IDENTIFICATION

LIFE SAFETY 101. Architecture Interior Design Planning Sustainable Design

Plan Check No. A. ELEVATORS

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

BUILDING CODE COMMISSION

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

BUILDING CODE COMMISSION

Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION

EXIT ACCESS RAMP. An interior ramp that is not a required interior exit ramp.

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

E2-09/ (IFC [B] )

SUPPLEMENTAL ACCESSIBILITY NO. 5 PLAN REVIEW CHECKLIST

EFFECTIVE USE OF THE IBC/CBC

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

BUILDING CODE COMMISSION

UBC. (1997 Edition) (p.1-116) 2-hr. shaft required for

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

UNDERSTANDING THE MASS TIMBER CODE PROPOSALS. A Guide for Building Officials

Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and

Minnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

FIRE AND SMOKE PROTECTION FEATURES

IBC MEANS OF EGRESS. Code Change No: E5-07/08. Original Proposal

Action Concept. Lumps CTL, solid and Glue Lam under heavy timber. I don't have any idea on arguments G 181 H O D

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Code Change No: FS43-06/07

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

2009 IBC/IFC Photoluminescent Signs & Pathway Marking Systems Frequently Asked Questions

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

A New Path Forward for Tall Wood Construction: Code Provisions and Design Steps

2015 IBC Special Building Types and Features IBC Special Building Types and Features. Copyright 2016 International Code Council 1

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

International Building Code Essentials for Wood Construction

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

6-Storey Residential Buildings Combustible Construction. A Regulator s Perspective City of Richmond, BC Canada

COUNCIL ORDER No

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

Code Compliant Fire Resistance Design for Wood Construction. Paul Coats, PE, CBO Southeast Regional Manager American Wood Council

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

SECTION 702 DEFINITIONS

Accessible Means Of Egress

INTERNATIONAL BUILDING CODE MEANS OF EGRESS

THE UNIVERSITY OF HONG KONG LIBRARIES. Hong Kong Collection gift from Faculty of Architecture The University of Hong Kong

2015 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

2012 IBC 715 TABLES

LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR 2004 A LOCAL LAW

COLUMBIA COUNTY LAND DEVELOPMENT SERVICES COURTHOUSE ST. HELENS, OREGON PHONE (503) CODE SUMMARY REQUIREMENTS

Outcomes of ICC Tall Wood Ad Hoc Committee: Proposals and Discussion

CMHI National Codes Task Report. Spatial Separation THE ISSUES. Current Status

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

WHO IS THIS COURSE FOR?

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

2015 IBC Accessible Means of Egress

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

ONTARIO REGULATION 350/06 BUILDING CODE

PRESCRIPTIVE COMPLIANCE METHOD

CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY DRAFT. FLORIDA BUILDING CODE BUILDING, 5th EDITION (2014) 4.1

Name of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one

Name of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one

G59 12: Final Decision AMPC1

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

Following are the NMHC/NAA Recommendations for the ICC Online Consensus Voting which opens on February 8 th, 2016:

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Worksheet for Commercial Building Planning

BUILDING CODE COMMISSION

Code Compliant Fire- Resistance Design for Wood Construction

Transcription:

Ontario Building Code (OBC) 1. Fire Separations 2. Fire Resistance Ratings By Classification 3. Fire Resistance Ratings By Adjacent Use 4. Fire Resistance Ratings By Specific Space 5. Fire Resistance Ratings - Exits 6. Spatial Separation

Ontario Building Code (OBC) 1. Fire Separations 2. Fire Resistance Ratings By Classification 3. Fire Resistance Ratings By Adjacent Use 4. Fire Resistance Ratings By Specific Space 5. Fire Resistance Ratings - Exits 6. Spatial Separation

1. Fire Separations i) Definitions Fire separation Fire-resistance rating Fire-protection rating Firewall Closure ii) Conditions to satisfy Code must be a continuous element (wall, floor etc.) which means a completely enclosed conditon must be of a construction type that gives the assembly a fire-resistance rating. Any openings to be protected with a rated closure. iii) Pertinent Code References? 3.1.8.1. General Requirements (1) Any wall, partition or floor assembly required to be a fire separation shall, (a) except as permitted by Sentence (2), be constructed as a continuous element, and (b) as required in this Part, have a fire-resistance rating as specified. (2) Openings in a fire separation shall be protected with closures, shafts or other means in conformance with Articles 3.1.8.4. to 3.1.8.18. and Subsections 3.1.9. and 3.2.8.

1. Fire Separations 3.1.8.3. Continuity of Fire Separations 3.1.8.4. Fire-Protection Rating of Closure (Table) Column 1 Column 2 Fire-Resistance Rating of Fire Separation Required Fire-Protection Rating of Closure 30 min 20 min 45 min 45 min 1 h 45 min 1.5 h 1 h 2 h 1.5 h 3 h 2 h 4 h 3 h

1. Fire Separations 3.1.8.6. Maximum Openings 3.1.8.7. Fire Dampers iv) Combustible vs. Non-combustible Construction Sections 3.1.4. and 3.1.5.

Ontario Building Code (OBC) 1. Fire Separations 2. Fire Resistance Ratings By Classification 3. Fire Resistance Ratings By Adjacent Use 4. Fire Resistance Ratings By Specific Space 5. Fire Resistance Ratings - Exits 6. Spatial Separation

2. Fire Resistance Ratings By Classification i) 3.2.2.20. -.83 we have already determined classification of our buildings. most articles will contain an instruction for floor separations. all articles will describe the need for rated construction around load-bearing components. may be dependent on whether combustible or non-combustible construction is chosen. watch for exceptions for sprinklered buildings. ii) Implications important to know for the requirements of rating building components. will determine the separations required for same occupancies of different floors. what about adjacent differing occupancies?

2. Fire Resistance Ratings By Classification iii) Final Thoughts we know our projects will be steel structure. will you have the option of exposing steel? think final details and final aesthetic.

Ontario Building Code (OBC) 1. Fire Separations 2. Fire Resistance Ratings By Classification 3. Fire Resistance Ratings By Adjacent Use 4. Fire Resistance Ratings By Specific Space 5. Fire Resistance Ratings - Exits 6. Spatial Separation

3. Fire Resistance Ratings By Adjacent Use i) Adjacent Use single occupancy relatively straightforward. based on building size and construction (3.2.2.20. 83.) applies to floors of similar occupancy. ii) Adjacent Use multiple occupancy your building classification tells you one thing for floors, yet Table 3.1.3.1. says something else. What do you do? ask yourself: what is the most stringent (severe) condition? use the most strict situation you find. iii) Construction Ratings multiple occupancies We have two occupancies in our projects. Loadbearing construction will be mostly steel. One building classification (A Assembly) says one thing, the other (E Mercantile) will say something else. ask yourself: what is the most stringent (severe) condition? use the most strict situation you find.

Ontario Building Code (OBC) 1. Fire Separations 2. Fire Resistance Ratings By Classification 3. Fire Resistance Ratings By Adjacent Use 4. Fire Resistance Ratings By Specific Space 5. Fire Resistance Ratings - Exits 6. Spatial Separation

4. Fire Resistance Ratings By Specific Space i) Specific Spaces Requiring Fire-Resistance Ratings service spaces (mechanical, etc.) service shafts (horizontal and vertical) electrical rooms transformer rooms exit stair shafts exit corridors barrier-free paths of travel corridor walls (public from private space) elevator shafts janitor rooms

4. Fire Resistance Ratings By Specific Space ii) Code References 3.2.2.14. (Fire Separation of) Rooftop Enclosures 3.2.2.15. Stories Below Ground (Fire Separation of Basements) 3.3.1.20. (Fire Separation of) Janitor s Rooms 3.3.1.7.(1) & (3) Fire Separation of Barrier-Free Path of Travel 3.4.4. Fire Separation of Exits (and Lobbies) 3.5.3.1. Fire Separation for Elevator Hoistways 3.6.2.1. Fire Separations Around Service Rooms 3.6.3.1. Fire Separation of Vertical Service Spaces 3.6.4.2. Fire Separation of Horizontal Service Spaces 3.1.8. Fire Separation and Closures (specifically doors)

Ontario Building Code (OBC) 1. Fire Separations 2. Fire Resistance Ratings By Classification 3. Fire Resistance Ratings By Adjacent Use 4. Fire Resistance Ratings By Specific Space 5. Fire Resistance Ratings - Exits 6. Spatial Separation

5. Fire-rating of Exits: Stairs and Corridors i) Code References: 3.4.4.1. & 3.3.1.4. ii) iii) = to floor but not less than 45 min or more than 2hrs 1 HR unless flr 45min then 45min

Ontario Building Code (OBC) 1. Fire Separations 2. Fire Resistance Ratings By Classification 3. Fire Resistance Ratings By Adjacent Use 4. Fire Resistance Ratings By Specific Space 5. Fire Resistance Ratings - Exits 6. Spatial Separation

6. Spatial Separation 3.2.3. Spatial Separation and Exposure Protection 3.2.3.1. Limiting Distance and Area of Unprotected Openings (1) Except as permitted by Articles 3.2.3.10. to 3.2.3.12., the area of unprotected openings in an exposing building face for the applicable limiting distance shall be not more than the value determined in accordance with, (a) Table 3.2.3.1.A. or Table 3.2.3.1.B. for an exposing building face conforming to Article 3.2.3.2. of a building or fire compartment that is not sprinklered, or (b) Table 3.2.3.1.C. or Table 3.2.3.1.D. for an exposing building face conforming to Article 3.2.3.2. of a sprinklered fire compartment that is part of a building that is sprinklered in conformance with Section 3.2. (2) The area of the unprotected openings in an exposing building face shall be the aggregate area of unprotected openings expressed as a percentage of the area of the exposing building face in Table 3.2.3.1.A., Table 3.2.3.1.B., Table 3.2.3.1.C. or Table 3.2.3.1.D. (3) For the purpose of determining the type of construction and cladding and the fire-resistance rating of an exterior wall, (a) the exposing building face shall be taken as the projection of the exterior wall onto a vertical plane located so that no portion of the exterior wall of the building or of a fire compartment, if the fire compartment complies with the requirements of Article 3.2.3.2., is between the vertical plane and the line to which the limiting distance is measured, and (b) the area of unprotected openings shall be determined from Table 3.2.3.1.A., Table 3.2.3.1.B., Table 3.2.3.1.C. or Table 3.2.3.1.D. (4) For the purpose of determining the actual percentage of unprotected openings permitted in an exterior wall, the location of the exposing building face is permitted to be taken at a vertical plane located so that there are no unprotected openings between the vertical plane and the line to which the limiting distance is measured.

6. Spatial Separation HOW THIS WORKS DO THIS FOR EVERY ELEVATION i) Pick the appropriate Table by occupancy governing your design, and sprinkler or non-sprinklered. ii) Calculate elevation surface area based on projecting the elevation onto a flat surface. iii) What is the least distance of that elevation to the property line? That will be your limiting distance. iv) Determine the ratio of your building height to building length along that elevation. v) Read off your percentage. vi) That percentage is taken from your total elevation surface area: your allowed area of Unprotected Openings. vii) Compare your current glazing design changes necessary?

6. Spatial Separation

6. Spatial Separation