PROJECT: SLAB DESIGN SITE ADDRESS LOT 36, HAMISH ROAD, DARLEY VICTORIA 3340

Similar documents
PROJECT: SLAB RE-DESIGN (WAFFLE), FRAMING & RETAINING WALLS DESIGN ADDRESS: 8, MARINGA STREET, BULLEEN VIC 3105

Concrete Slab-on-Ground

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

Foundation Design Report

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

Pulaski County, Virginia

1 AND 2 FAMILY DWELLING REQUIREMENTS

Let s Make a Difference. Presented by: Samuel Tran, P.E.

Building Construction

GUIDELINES FOR RETAINING WALLS 4-0 IN HEIGHT OR LESS

ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD,

Stone and Masonry Veneer

ASSOCIATION OF CONSULTING STRUCTURAL ENGINEERS VICTORIA

INSTALLATION INSTRUCTIONS

APPLICATION FOR A BUILDING PERMIT (Retaining Wall/Garden Wall Construction Details)

0331 Brick and block construction

Construction Technology B (CON4313)

ITEM 481 MONOLITHIC REINFORCED CONCRETE BOX SEWERS

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Concrete. Copyright: Quasar Management Services Pty Ltd

This specification describes the minimum requirements for Vale's standard practice for Concrete drawings.

CONCRETE SLABS Job Ready Checklist

FOUNDATIONS. Foundations Copyright G G Schierle, 2006 Press Esc to end, for next, for previous slide 1

4 EXTREME FOUNDATION PANELS

Civil Engineering Construction I (CBE5031)

Radon Resistant New Construction. Topic 8 - Audio 64

DECK DAMAGE AND PENETRATIONS

RIBRAFT TECHNICAL MANUAL

2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

CHAPTER 8. Concrete Work

RIBRAFT TECHNICAL MANUAL

WHY USING A SOIL CAP ON EXPANSIVE SOIL IS NOT ALWAYS THE SOLUTION

RUNNERS (Required to convert to real property)

OCTOBER RibRaft TECHNICAL MANUAL CBI 3321/3323

B M CIVIL ENGINEERS 17/10/2016. CLIENT: Summit Group. JOB DESCRIPTION: Provide limited site investigation & site classification for the allotment.

NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003)

Building in a Saline Environment

Fence Stone. Self locating Wall System

Installation Guidelines VBC Products

Retaining Walls. Made Easy

TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201

NELSON CITY COUNCIL INFRASTRUCTURAL ASSETS SD 601 APPROVED SENIOR EXECUTIVE INFRASTRUCTURE

Self Locating Wall System

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes

Residential Building Inspections

Section CONCRETE SIDEWALKS. 1. Payment for concrete sidewalks is on square foot basis.

PERMEABLE INTERLOCKING PAVERS

PECAFIL APPLICATION PRODUCT DESCRIPTION ADVANTAGES SITE SAFETY BENEFITS SIZES

ITEM 432 RIPRAP. Dry Riprap is defined as Stone Riprap of the required type with voids filled only with spalls or small stones.

Joint Free Slabs On Grade Website:

PANHANDLE RESIDENTIAL FOUNDATION MANUAL

SENTINEL BARRIER - GENERAL INSTALLATION GUIDELINES

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

Footing Centerline Note: 1:100. fall. fall 1:100. fall 1:100. 1:100 fall 1:100 1:100. fall. fall 1: step. fall.

Drainage, Road Drainage and Collection Pit A - EXCAVATION:

INSPECTION REQUIREMENTS: FOUNDATIONS

FORMDECK. constructions. constructions

F500 Steeplechase Waterjump with Valve Option

Scanned by CamScanner

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

ARMOR-BLOCK. Installation guide. Installation Manual: ARMOR-BLOCK Retaining Wall System. Cap Block. Exposed void for planting.

Installation Guidelines


ARCHITECTURAL DRAWINGS

REGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS

STANDARD DESIGN NOTES 1 / 2

City of Westerville Guide to Commercial Inspections

Stage 5S. Stage 5U. Stage 5W. Stage 5V. LEGEND Zone A - TC2 Foundation and Gravel Raft Extent of Gravel Raft Zone B - TC2 Foundation

A Design Review of Waterproofing Codes

SDCS-02 CONSTRUCTION STANDARD FOR

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

STANDARDIZED STRUCTURES

Garage/Accessory Structures

Specialty Applications. for Keystone Walls

Department of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

Concrete Soffit Direct Fix

EVOH PENETRATIONS INSTALLATION GUIDELINES PERMINATOR PLACEMENT

Good Construction Practices Part I

CONSTRUCTION SPECIFICATION FOR CONCRETE PAVEMENT AND CONCRETE BASE

REINFORCED CONCRETE MASONRY SECTION

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Control of Random Cracking in Concrete Residential Pavements

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

INSTALLATION GUIDELINES

CHECKING MANUAL FOR THE EXAMINATION OF RESIDENTIAL PLANS AND INSPECTION OF RESIDENTIAL CONSTRUCTION IN GRENADA

Description Unit Quantity Rate Kshs. Amount Kshs.

Employment Intensive Infrastructure Program (EIIP) in Lebanon ANNEX 2

New Zealand Concrete Masonry Manual

10 EXTREME BASEMENT PANELS

CONSTRUCTION SPECIFICATION FOR CONCRETE ROAD BASE

Detailed Estimating-Introduction. Dr. Al-Hammad

Reinforced Concrete Block Walls

MagnumStone Specifications Gravity

SITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT

FirstEnergy Program Overview

Transcription:

SITE ADDRESS LOT 36, HAMISH ROAD, DARLEY VICTORIA 3340 ABN: 84119322438, EC 19060 9 NUMERING COURT, MELTON 3337 PHONE: 03 9746 0089 MOBILE: 0401023328 EMAIL: priyan@wbcse.com.au NOTE: SETTING-OUT OF ANY ELEMENT MUST BE DONE AS PER ARCHITECTURAL PLANS. DIMENSIONS PROVIDED ON THESE PLANS MUST ALWAYS BE CHECKED AGAINST ARCHITECTURAL PLANS. STRUCTURAL ENGINEER (MOBILE: 0401023328)MUST BE KEPT INFORMED IMMEDIATELY OF ANY DISCREPANCY AND CLARIFICATION SOUGHT BEFORE SETTING-OUT AND CONCRETING IS ORGANISED. 1/6 A REVISED SH. NOS 5/6 & 6/6 01/06/2016 PW Rev. Remarks/comments Date Aprv.

STANDARDS, MATERIALS, AND WORKMANSHIP REQUIREMENTS THESE NOTES TO BE FOLLOWED UNLESS NOTED OTHERWISE BY THE ENGINEER 2/6

SITE DRAINAGE REQUIREMENTS 3/6

SLAB, BEAM & OTHER CONSTRUCTION REQUIREMENTS THESE NOTES TO BE FOLLOWED UNLESS NOTED OTHERWISE BY THE ENGINEER Natural ground level Service Excavation 100mm min. Foundation (Typical) Footing depth to be increased to be below critical depth line 30 0R 45 All excavation depths to be above critical depth line 30 deg. for Sand / 45 deg. for Clay SERVICE TRENCH EXCAVATION ADJACENT TO FOUNDATIONS NTS STEEL & TIMBER BEAMS/LINTELS Steel/Timber beams/lintels to be supported a minimum of 100mm UNO. Steel beams/lintels to be protected from corrosion as per Note S9 on sheet 2/6 of this set of plans. 4/6

WAFFLE SLAB ON GROUND - TYPICAL DETAILS - SEE SCHEDULE ON SH. 6/6 BRICK WORK (TYP.) Weepholes @ 1.2m c/c include flashing as standard Semi-permeable ordinary fill Clay subgrade Grade ground down to subgrade at 1 in 20 slope away from the foundation minimum 1000mm around the perimeter Reo bar tied to mesh bar tied to mesh EDGE BEAM NTS 0.20mm polythene membrane on quarry product (typ.) Slab th. 100mmTYP Reo bar 50-mm quarry product (Compact) Reo bars N16 dowell bars @ 400 c/c - 500mm long. One end of bar must be made moveable by wrapping with 'Densotape' REINFORCEMENT MESH INTERNAL RIB NTS CONSTRUCTION JOINT NTS Typical Pod size 1090mmx1090mmx 300mm deep 50-mm quarry product (Compact) Sleeve to pipe to have 40mm radial clearance and lagged with polythene 50-mm quarry product (Compact) Reo bars (typ.) Cut the bar to form a void of minimum rib width (100mm typ) at pipe. Overlap a bar 500mm each side (No lagging Required) SERVICE PENETRATION IN RIB PLAN VIEW NTS Grade 20 MPa mass concrete pier, sized and founded into ground as specifies on sheet 6/6 BORED PIER TYPICAL DETAIL NTS Reo bar Reo bars (TYP.) STEP DOWN NTS 50-mm quarry product (Compact) NOTE 1 ENSURE A LEVELED WORKING GROUND SURFACE/FILING MATRIAL IS WELL COMPACTED PROPOR TO PLACEMENT OF WAFFLE PODS. ANY FILL PLACED DUE TO CUT/FILL OPERATIONS SHALL BE COMPACTED AS "CONTROLLED FILL" IN ACCORDANCE WITH AS 2870-2011 6.4.2.(a). COMPACTION DENSITY TO BE VERIFIED. DEPTH OF FILL NOT TO EXCEED 300MM. NOTE 2 SUITABLE QUARRY PRODUCTS INCLUDE WELL GRADED QUARRY SAND OR RUBBLE HAVING A MZ E AXIMUM PARTICLE SIZE OF 20MM. NOTE 3 EXTERNAL / INTERNAL RIBS WIDER THAN 300MM SHALL BE REINFORCED WITH AN ADDITIONAL N16 BAR TOP & BOTTOM FOR EVERY ADDITIONAL 110MM I WIDTH (TYP.). NOTE 4 ALL MASS CONCRETE PIERS TO UNDERSIDE OF SLAB/EDGE BEAMS, NOT SHOWN FOR CLARITY. REINFORCEMENT (REO) SHOWN HERE ARE TYPICAL ONLY. Tench mesh to be lapped 500mm typica Min. length to be sleeve dia. + 500mm Service pipe SERVICE PENETRATION IN BEAMS NTS Locally deepen beam by sleeve diameter 5/6 Cut mesh wires to insert service pipes with minimum cover 30mm around Provide additional 4-N12 bars 1200 min. length tied to mesh where service pipe inserts are made for plumbing SERVICE PENETRATION IN SLAB PLAN VIEW NTS

WAFFLE SLAB ON GROUND + 3-12TM (top)- min. 2000mm long centrally located 150mm th. SLAB on 200mm OF CLASS 3 WELL COMPACTED FCR. DIMENSIONS TO BE AS PER ARCHITECTURAL PLANS AND REINFORCED WITH SL92 T&B Waffle Slab Schedule Overall Slab Depth - 400mm Void form height - 300mm Slab thickness - 100mm Internal beam/rib width - 110mm External beam width - 300mm Stem width min. - 150mm Pod size - 1090mmx1090mmx300mm X - Denotes standard pods + - Denotes optional setout point >>Vapour barrier in accordance with BCA to be lapped 200mm min. and taped at lap-joints, to be laid on a 50mm quarry product. >>Concrete strength to be 20MPa at 28 days with a slump of 100mm at pouring. Reinforcement Top Slab mesh - SL92 Internal beam/rib 1-N16 (tied to mesh) External beam 1-N16 (tied to mesh) Bottom Internal beam/rib - 1-N16 External beam - 3-N16 Note: 3-N16 or 2/3L12TM200 acceptable Minimum lap lengths 3-L12TM: 500mm SL 92/82 Mesh: 250mm N16 bars: 600MM Piers (Bored) 450mm dia. 20MPa concrete. Founding depth 800mm from ground level. All Piers to be poured at once before the slab is poured. REINFORCEMENT LAPPING IN BEAMS NTS 6/6 Note 1: The Builder shall ensure that during construction the surface and roof stormwater is drained away from the house foundation.