LATTICE GIRDERS CONNECTING ELEMENTS BETWEEN PRECAST CONCRETE COMPONENTS AND IN-SITU CONCRETE

Similar documents
Austral Deck Design for Construction Loading. Permanent formwork and Span capability

Technical Guideline for AVI NIRO THERMOKORB

A-8074 Raaba-Grambach, Gustinus-Ambrosi-Straße 1-3

NEW for high shearing forces REINFORCEMENT SYSTEMS

Investigating the Use of Swimmer Bars as Shear Reinforcement in Reinforced Concrete Beams

UNIT-I DESIGN CONCEPTS, DESIGN OF BEAMS Part - A (Short Answer Questions)

The Use of Bolted U-Link Swimmer Bars in the Reinforced Concrete Beams

OXFORD ENGINEERING COLLEGE (NAAC Accredited with B Grade) Department of Civil Engineering LIST OF QUESTIONS

Abacus Programs. Release Notes. RIB Software SE

FLOOR STRUCTURES. Floor structures Building Construction I.

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 2, 2012

STEEL STRUCTURAL SYSTEMS

Diploma in Civil Engineering. Term-End Examination June, BCE-041 : THEORY OF STRUCTURES II

THE BEHAVIOUR OF LIGHTWEIGHT COMPOSITE FLOOR TRUSSES IN FIRE

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

Schöck Isokorb type CV

Renovation of Buildings using Steel Technologies (ROBUST)

Schöck Isokorb type KS

DESIGN OF RC BEAMS AND FLOORS, BRACING

Layher Aluminium Lattice Beams. Information and User Guide. Aluminium Lattice Beam 750 (Product Code 4903XXX)

Masonry and Cold-Formed Steel Requirements

BS EN :2004 EN :2004 (E)

CHAPTER 10: GENERAL STRUCTURAL DETAILS

Schöck Isokorb type K-HV, K-BH, K-WO, K-WU

ST7008 PRESTRESSED CONCRETE

Modelling of RC moment resisting frames with precast-prestressed flooring system

In the following calculation a combination of Eurocode 2 and Eurocode 7 has been used. Design yield strength. Young modulus. Poisson coefficient.

Multideck 146. Contents

UNIT IVCOMPOSITE CONSTRUCTION PART A

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

Module Title: Advanced Structural Design

PRECAST CONCRETE CONNECTIONS

CHAPTER 3 BEHAVIOUR OF FERROCEMENT HOLLOW SLABS


mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Design for Shear for Prestressed Concrete Beam

Contents. Foreword 1 Introduction 1

COLUMNS. Classification of columns:

VALLIAMMAI ENGINEERING COLLEGE

SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT

5.4 Analysis for Torsion

Experiment on Precast Solid Concrete Floor Slabs resting on Cold- Formed Steel Framing Stud Walls

1 Prepared By:Mr.A.Sathiyamoorthy, M.E., AP/Civil

Innovations in Tied Arch Bridges

Flexural Capacity of the Concrete Beams Reinforced by Steel Truss System

Murfor. Murfor BEKAERT. Reinforcement for masonry. Product identification range of applications Installation details Design principles CI/SFB

Investigating the Use of Spliced Swimmer Bars as Shear Reinforcement in Reinforced Concrete Beams

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

Diagonal Ties Connectors for precast concrete sandwich panels. Version: AE, SA 08/2018. Technical Manual

Title. Author(s)SARBINI, N. N.; IBRAHIM, I. S.; SAIM, A. A. Issue Date Doc URL. Type. Note. File Information

DESIGN OF RETAINING WALLS

Three Hours I I Maxi;lUm Marks I

North Mountain IMS Medical Office Building

BubbleDeck Design Guide. The two-way hollow deck. The way to new solutions

IZODOM 2000 POLSKA Zduńska Wola, ul. Ceramiczna 2. tel , , tel./fax

TECHNICAL MANUAL. PSB Punching Reinforcement. Shear Reinforcement for Concrete Structures

MULTIFLEX Girder slab formwork. Assembly Instructions for Standard Application

Prestressed Concrete Design (SAB 4323) Composite Beams. Dr. Roslli Noor Mohamed

HARVEY MUDD COLLEGE TEACHING AND LEARNING CENTER SECTION Page 1 of 6 VOIDED CONCRETE SLAB

COFS Mission. AISI Standards Hierarchy. North American Standards for Cold-Formed Steel Framing. Member versus System Design. Specification 10/21/2016

EVALUATION OF JOISTS AND THEIR TYPICAL REINFORCEMENT IN STEEL- FRAMED BUILDINGS: SUGGESTIONS OF JOIST MEMBERS REINFORCEMENT

VARIOUS TYPES OF SLABS

Spatial analysis of concrete filled steel tubular tied arch bridge

Lattice Plate Flooring

[Thomas*, 4(10): October, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

The Steel Construction Institute

Sabah Shawkat Cabinet of Structural Engineering 2017

Flexure and Serviceability Limit State

IABSE SYMPOSIUM NANTES, 2018

MAHALAKSHMI ENGINEERING COLLEGE

DEPARTMENT OF ARCHITECTURE ABUBAKAR TAFAWA BALEWA UNIVERSITY, BAUCHI ARC 615: ADVANCED BUILDING STRUCTURES LESSON 4: VECTOR ACTIVE STRUCTURAL SYSTEMS

Strength Design of Reinforced Concrete Structures

Preliminary design of concrete structures 124SDP1

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

DATA SHEET 3 Concrete Masonry Lintels MARCH 2013

Structural Engineering

6. Design of Portal Frames (For class held on 20 th, 26 th and 27 th March 07)

PERFECT SLABS Bernie de Klerk

EXPERIMENTAL INVESTIGATION ON THE LOAD- CARRYING CAPACITY OF THIN WEBS INCLUDING POST-TENSIONING TENDONS

TECHNICAL MANUAL. ARMATA Punching Reinforcement. Deformed Shear Reinforcement to Reduce Congestion

GT 24 Formwork Girder The versatile lattice girder with a high load-bearing capacity. Product Brochure

Hoesch Additive Floor Technical information The easily mounted floor system for large spans

Lifting Sockets. Flat Lifting Sockets

BISON PRECAST FLOORING SPECIFICATION

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

Recommendations for additional fire protection of structural elements

Schöck Isokorb type CVB Design

Regulations. Requirement: A1 Loading Comment: Requirement: B3(1) Internal fire spread (structure) Comment:

Level 6 Graduate Diploma in Engineering Structural analysis

CE2401-DESIGN OF REINFORCED CONCRETE AND BRICK MASONRY QUESTION BANK

Schöck Isokorb Type CV

CIVIL ENGINEERING YEAR QUESTION BANK

Concrete shear keys in prefabricated bridges with dry deck joints

Improving Thermal Insulation Properties for Prefabricated Wall Components Made Of Lightweight Aggregate Concrete with Open Structure

FRANK Stremaform formwork elements

Chapter. Masonry Design

GERMAN STRUCTURAL ENGINEERING INSTITUTE Public-law institution

CONNECTOR B L O C K S H E A R. Design for Composite Structural Action BLOCK SHEAR CONNECTOR APPLICATION. Airspace

Questions with solution

Transcription:

WWW.AVI.AT LATTICE GIRDERS CONNECTING ELEMENTS BETWEEN PRECAST CONCRETE COMPONENTS AND IN-SITU CONCRETE

LATTICE GIRDERS LATTICE GIRDERS FOR HALF SLABS SPECIAL GIRDERS GIRDERS WITH GERMAN APPROVAL LATTICE GIRDERS WITH THE COMPLETE REINFORCEMENT REQUIRED FOR RESIDENTIAL BUILDINGS Large panel slabs (half slabs) Double walls (precast cavity walls) Rib slabs (Concrete and precast rib slab with clay bricks) Lattice girders are three-dimensional, industrially prefabricated reinforcing elements. They consist of an upper chord and two lower chords and continuous truss wires. These are connected to the chords by means of electric resistance welding. All types of girder are available at short notice if ordered in the appropriate minimum quantities (approx. 10 t). ADVANTAGES OF THE PRODUCT Secures the bonding between precast slabs and in-situ concrete in the final state Load-bearing capacity and serviceability of precast slab when installed Spacer strip for upper reinforcing element Lower chords as flexural tensile reinforcement No diagonal projection on the upper chord side Ample scope of design Welded at all joints Good transfer of shear forces Perfect straightness a bars d1 d2 Upper chord Lower chord d3 H a ba Weight and dimensional tolerances as per ÖNORM B 4707 2

LATTICE GIRDERS FOR HALF SLABS This type of girder is a stocked product and therefore available at short notice. DIMENSIONS Height H Upper Chord d3 d2 Lower Chord d1 Angle of Inclination Factory Length Weight per m Shear Resistance V Rds /z Internal Forces at Assembly Permissible Buckling Moment of Upper Chord V Rds = (A SW /s) z f ywd (cot + cot ) sin... Design value of resistance [kn] of diagonal reinforcement against shear force... Angle of inclination of diagonal wires... Angle of compression struts z... Lever arm of internal forces [m] Permissible Shear Force of mm mm mm mm m kg/m kn/m knm/ kn/ 90 7.2 4.6 5.0 42.0 14.0 0.98 48.4 (1.110 + cot ) 0.49 4.30 110 7.2 4.6 5.0 47.7 14.0 1.02 53.5 (0.910 + cot ) 0.60 4.05 120 7.2 4.6 5.0 50.2 14.0 1.04 55.5 (0.833 + cot ) 0.66 3.81 130 7.2 4.6 5.0 52.4 14.0 1.06 57.3 (0.770 + cot ) 0.72 3.57 140 7.2 4.6 5.0 54.5 14.0 1.08 58.8 (0.714 + cot ) 0.78 3.33 150 7.2 4.6 5.0 56.3 14.0 1.10 60.1 (0.667 + cot ) 0.84 3.10 170 8.0 5.0 5.0 59.5 14.0 1.31 73.6 (0.589 + cot ) 1.44 3.75 180 8.0 5.0 5.0 60.9 14.0 1.34 74.6 (0.556 + cot ) 1.53 3.49 190 8.0 5.0 5.0 62.2 14.0 1.37 75.5 (0.527 + cot ) 1.62 3.24 200 8.0 5.0 5.0 63.4 12.0 1.39 76.4 (0.501 + cot ) 1.71 3.02 230 8.0 5.0 5.0 66.5 14.0 1.48 78.3 (0.435 + cot ) 1.97 2.46 240 8,0 5,0 5,0 67,4 14,0 1,50 78,8 (0,416 + cot ) 2,06 2,31 250 8,0 5,0 5,0 68,2 12,0 1,53 79,3 (0,400 + cot ) 2,15 2,16 3

SPECIAL GIRDERS Special girders are manufactured on individual customer demands. DIMENSIONS, CROSS SECTIONS Heights H Upper Chord d3 d1 d2 Spacing of Bars a Bottom Width ba Supply Lengths mm mm mm mm mm mm 70 400 6 14 5 14 4 8 200 ca. 80 Factory lengths 12 14 m or fixed lengths in increments of 100 mm STEEL CHARACTERISTICS FOR TRUSS GIRDERS ACCORDING TO ÖNORM B 4707 Component Yield Strength Ratio of Tensile Strength/Yield Strength* N/mm 2 N/mm 2 : reinforcing steel B550A ribbed Upper Chord: B500A smooth or B550A ribbed : B500A smooth or B550A ribbed 550 1.05 500 / 550 1.05 500 / 550 1.05 * for d = 5.0 to 5.5 mm, ratio of tensile strength/yield strength of 1.03 applies. No proof required for d < 5 mm GIRDERS WITH GERMAN APPROVAL The truss girders with German technical approval by DIBt include ALD truss girders for precast slabs with structural in-situ concrete layer and ALW truss girders for slab walls. Component Yield Strength Ratio of Tensile Strength/Yield Strength N/mm 2 N/mm 2 : reinforcing steel B500A ribbed Upper Chord: B500A smooth or B500A ribbed : B500A smooth or B500A ribbed 500 1.05 500 1.05 500 1.05 4

LATTICE GIRDERS WITH THE COMPLETE REINFORCEMENT REQUIRED FOR RESIDENTIAL BUILDINGS Lattice girders with the complete reinforcement required for residential buildings are a special form of truss girder. The lower chord already contains the complete reinforcement for floor loads commonly found in residential buildings. Additional reinforcing elements are required for wider spans and heavier loads. Delivery in sets of 50 is in lengths of 1.20 m to 6.80 m, with a girder height of 150 mm, and 5.60 m to 8.00 m, with a girder height of 190 mm. Length increments are 20 cm. 200 Ø 8 OG B500A SHEAR RESISTANCE OF GIRDER DIAGONALS UG B550A Ø 5 B500A 56.3 (62.2 ) 150 (190) Height Shear Resistance V Rds /z 150 mm 71.0 (0.667 + cot ) Dimensions in mm 200 approx. 70 190 mm 75.5 (0.527 + cot ) PRODUCT RANGE WITH HEIGHT OF 150 MM Length Diameter Cross-section Weight m mm cm 2 kg/m 1.20 2.20 5 + 5 0.39 1.26 2.40 5 + 6 0.48 1.33 2.60 6 + 6 0.57 1.39 2.80 6 + 7 0.67 1.47 3.00 7 + 7 0.77 1.55 3.20 7 + 8 0.89 1.65 3.40 8 + 8 1.01 1.74 3.60 8 + 9 1.14 1.84 3.80 9 + 9 1.27 1.95 4.00 9 + 10 1.42 2.07 4.20 10 + 10 1.57 2.18 4.40 10 + 11 1.74 2.31 4.60 11 + 11 1.90 2.44 4.80 11 + 12 2.08 2.58 5.00 12 + 12 2.26 2.73 5.20 12 + 14 2.67 3.05 5.40 12 + 14 2.67 3.05 5.60 14 + 14 3.08 3.37 5.80 14 + 14 3.08 3.37 6.00 14 + 14 3.08 3.37 6.20 14 + 14 3.08 3.37 6.40 14 + 14 3.08 3.37 6.60 14 + 14 3.08 3.37 6.80 14 + 14 3.08 3.37 INTERNAL FORCES AT ASSEMBLY Height Permissible Buckling Moment of Upper Chord (knm/) Permissible Shear Force of (kn/) 150 1.27 4.33 190 1.62 3.24 PRODUCT RANGE WITH HEIGHT OF 190 MM Length Diameter Cross-section Weight m mm cm 2 kg/m 5.60 14 + 14 3.08 3.47 5.80 14 + 14 3.08 3.47 6.00 14 + 14 3.08 3.47 6.20 14 + 14 3.08 3.47 6.40 14 + 14 3.08 3.47 6.60 14 + 14 3.08 3.47 6.80 14 + 14 3.08 3.47 7.00 14 + 14 3.08 3.47 7.20 14 + 14 3.08 3.47 7.40 14 + 14 3.08 3.47 7.60 14 + 14 3.08 3.47 7.80 14 + 14 3.08 3.47 8.00 14 + 14 3.08 3.47

studiobleifrei.at For any information about availability and price of our products, please contact our sales department. ALPENLÄNDISCHE VEREDELUNGS-INDUSTRIE GESELLSCHAFT M.B.H. Gustinus-Ambrosi-Straße 1 3 8074 Raaba-Grambach/Austria T +43 316 4005-0 F +43 316 4005-507 avi-verkauf@avi.at www.avi.at Lattice s-01/17-1.0-e WWW.AVI.AT