Residual strength of Y-type perfobond rib shear connectors to cyclic load on highway bridge

Similar documents
Investigation on Static Behavior of Multi-Stud Shear Connectors for Composite Bridges

AN ANALYTICAL AND EXPERIMENTAL INVESTIGATION OF SHEAR CONNECTORS IN COMPOSITE SECTIONS

Study on structural behavior characteristics of concrete filled steel tube girder bridges

Various Types of Shear Connectors in Composite Structures

Structural Characteristics of New Composite Girder Bridge Using Rolled Steel H-Section

Joint Design of Precast Concrete Moment Frame using Hollow Precast Concrete Column Soo-Yeon Seo, Tae-Wan Kim, Jong-Wook Lim, Jae-Yup Kim

EXPERIMENTAL RESEARCH ON THE MECHANICAL PROPERTIES OF SHEAR CONNECTORS FOR COMPOSITE BEAM BRIDGE

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

STATIC TESTS ON VARIOUS TYPES OF SHEAR CONNECTORS FOR COMPOSITE STRUCTURES

Evaluation of the Shear Strength of Perfobond Rib Connectors in Ultra High Performance Concrete

Design of Double Composite Bridges using High Strength Steel

Study on Bearing Capacity Formula and Influence Factors of PBH Shear Connectors

Development of Composite Beam for Productivity

Analytical Study on a Longitudinal Joints of the Slab-Type Modular Bridges Sang-Yoon Lee, Jung-Mi Lee, Hyeong-Yeol Kim, Jae-Joon Song

Lap Splices in Tension Between Headed Reinforcing Bars And Hooked Reinforcing Bars of Reinforced Concrete Beam

Steel concrete composite construction is re-emerging. Development and Testing of a New Shear Connector for Steel Concrete Composite Bridges

Evaluation of Ultimate Strength of Steel- Concrete Hybrid Girder Using 80-MPa High- Strength Concrete

Demountable Shear Connectors for Sustainable Composite Construction

Fatigue Performance of Precast FRP-Concrete Composite Deck with Long Span

Experimental Evaluation of Fatigue Performance of Steel Grid Composite Deck Joints

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

Crack detection in composite bridges with relative displacement sensors

Title. Author(s)KIM, D. W.; SHIM, C. S. Issue Date Doc URL. Type. Note. File Information

STRUCTURAL PERFORMANCE OF STEEL-CONCRETE-STEEL SANDWICH COMPOSITE BEAMS WITH CHANNEL STEEL CONNECTORS

A COMPOSITE FLOOR TRUSS TOP CHORD USING CONCRETE-FILLED STEEL TUBE (CFST)

3.4.2 DESIGN CONSIDERATIONS

Compression Test for Precast Encased Composite Columns with Corrugated Steel Tube

Field Load Testing of the First Vehicular Timber Bridge in Korea

CYCLIC RESPONSE OF RC HOLLOW BOX BRIDGE COLUMNS STRENGTHENED USING CFRP AND RC JACKETING

Progressive Collapse Resisting Capacity of Moment Frames with Infill Steel Panels

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

RECENT RESEARCH OF SHEAR CONNECTION IN PREFABRICATED STEEL-CONCRETE COMPOSITE BEAMS

INVESTIGATION OF CURING PERIOD OF CEMENTITIOUS ADHESIVE AND PERFORMANCE OF RUST PREVENTION

COMPOSITE BRIDGES WITH PRECAST CONCRETE SLABS

SEISMIC BEHAVIOR AND DESIGN OF STEEL SHEAR CONNECTIONS WITH FLOOR SLABS

Axial Load Behaviors of PSRC Composite Columns with Anchor-Type Transverse Reinforcements

Design Guidance for TAB-Deck Composite Slabs using SMD Metal Decking reinforced with ArcelorMittal Steel Fibres

Title. Author(s)KIM, K.; LEE, K. S.; KANG, Y. J. Issue Date Doc URL. Type. Note. File Information CONSTRUCTION

Use of the Promising Composite Delta Deck for Various Composite-deck Bridges

ACCELERATED REPLACEMENT OF STEEL PLATE RAILWAY BRIDGES USING MOVING CRANES ON RAILROAD

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

BEHAVIOUR OF SHEAR CONNECTORS IN COMPOSITE CONSTRUCTION

WHEEL TRUCKING TEST FOR WELD OF U-SHAPED RIB AND DECK PLATE IN THE ORTHOTROPIC STEEL DECK. Susumu Inokuchi 1

HILTI HY 150 REBAR DESIGN GUIDE

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

ANALYSIS AND ASSESSMENT OF ARTICULATED SKEW HOLLOW SLAB BEAM BRIDGE

Strength of Non-Prismatic Composite Self-Compacting Concrete Steel Girders

Experimental study on seismic behavior of composite concrete and

TESTS AND MODELING OF T-STUB BOLTED I-BEAM TO SHS-COLUMN FRAME CONNECTIONS

UPGRADING OF AN EXISTING CONCRETE-STEEL BRIDGE USING FIBRE REINFORCED POLYMER DECK- A FEASIBILITY STUDY

A NEW CFRP STRENGTHENING TECHNIQUE TO ENHANCE PUNCHING SHEAR STRENGTH OF RC SLAB-COLUMN CONNECTIONS

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

EUROPEAN RESEARCH INTO COMPOSITE STEEL-CONCRETE STRUCTURES

FINAL REPORT. Prepared by

Pile to Slab Bridge Connections

Experimental analysis of Perfonbond shear connection between steel and Pre-stressed concrete

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

Evaluation of Shear Demand on Columns of of Masonry Infilled Reinforced Concrete Frames

Natural frequency of a composite girder with corrugated steel web

Project Objective. Strengthening Bridges by Developing Composite Action in Existing Non-Composite Bridge Girders

Field and Laboratory Performance of FRP Bridge Panels

PARTIAL COMPOSITE ACTION IN SC COMPOSITE WALLS FO NUCLEAR STRUCTURES

UHPC Connection of Precast Bridge Deck

PERFORMANCE OF MECHANICAL SEISMIC LOAD TRANSMISSION DEVICE BASED ON IMPACT

Shear Strengthening Effects with Varying Types of FRP Materials and Strengthening Methods

External Post-tensioning of Composite Bridges by a Rating Equation Considering the Increment of a Tendon Force Due to Live Loads

Finite element analysis on steel-concrete-steel sandwich composite beams with J-hook shear connectors

An innovative concrete-steel structural system allowing for a fast and simple erection

BENDING BEHAVIOR OF PRECAST BRIDGE SLABS IN UHPFRC UNDER STATIC AND CYCLIC LOADINGS

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

THE ANALYTICAL STUDY OF STRENGTHENING THE HORIZONTALLY CURVED STEEL BEAM WITH CFRP LAMINATES

Creep and Shrinkage Analysis of Composite Truss Bridge with Double Decks

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

SEISMIC PERFORMANCE OF SCBF BRACED FRAME GUSSET PLATE CONNECTIONS

RECOMMENDATION DOCUMENT FOR THE DESIGN OF PREQUALIFIED PRECAST CONCRETE BOLTED CONNECTIONS FOR SEISMIC APPLICATIONS (SA_LJ2015)

Long-term Stress of Simply Supported Steel-concrete Composite Beams

Effect of Flange Width on Flexural Behavior of Reinforced Concrete T-Beam

SEISMIC BEHAVIOR OF HYBRID SYSTEM WITH CORRUGATED STEEL SHEAR PANEL AND RC FRAME

Effect of Loading and Beam Sizes on the Structural Behaviors of Reinforced Concrete Beams Under and After Fire

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

REVIEW PAPER ON USAGE OF FERROCEMENT PANELS IN LIGHTWEIGHT SANDWICH CONCRETE SLABS

Flexural Capacity of Composite Beams (Steel & Concrete) A Review

Seismic behavior of steel plate - concrete composite shear walls

Nonlinear Finite Element Analysis of Composite Cantilever Beam with External Prestressing

STABILITY AND DUCTILITY OF CASTELLATED COMPOSITE BEAMS SUBJECTED TO HOGGING BENDING

FLEXURAL CAPACITIES OF REINFORCED CONCRETE TWO-WAY BUBBLEDECK SLABS OF PLASTIC SPHERICAL VOIDS

STUDY ON THE FLEXURAL BEHAVIOUR OF CFRP-GRID REINFORCED CONCRETE ONE-WAY SLABS

CUREe-Kajima Flat Plate 1 Kang/Wallace

Numerical Study on Interface Parameters of Sprayed Waterproofing Membrane by Direct Shear Test

Design of Large Diameter Pre-Tensioned High Strength Concrete Pile Reinforced by In-Filled Concrete and Reinforcing Bars

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Figure 1 shows a typical composite beam for reference. The beam shown is a rolled beam section from the built-in section database.

Structural behaviour and failure mechanisms of concrete monoblock railway sleepers

Cracking Behavior in Precast Deck Slab Concrete Structure under Cyclic Loading

Research on Weight Reduction of PC Composite Members Using Ultra High Strength Fiber Reinforced Cementitious Composites (UFC)

COMPOSITE BEAM COMPOSED OF STEEL AND PRECAST CONCRETE (MODULARIZED HYBRID SYSTEM). PART III: APPLICATION FOR A 19-STOREY BUILDING

Punching shear strength of RC slabs with AFRPm and PVA short-fiber-mixed shotcrete


Development of New PSC Box Girder Bridge with Concrete-filled FRP Struts

DISTORTION-INDUCED FATIGUE CRACKING AT WEB-GAP OF WELDED I-BEAMS

Transcription:

Residual strength of Y-type perfobond rib shear connectors to cyclic load on highway bridge *Kun-Soo Kim 1), Sang-Hyo Kim 2), Min-Kyu Lee 3) and Sejun Park 4) 1), 2), 3), 4) School of Civil and Environmental Engineering, Yonsei University, Seoul, Korea 1) kun-soo_kim@yonsei.ac.kr ABSTRACT The plastic slip amplitude of Y-type perfobond rib shear connectors under cyclic loading is estimated. Load range of cyclic loading test was determined 30kN to 300kN in according to Korea Highway Bridge Specifications. The Y-type perfobond rib shear connectors are embedded in RC slab like the typical push-out test specimen. Under repeated loading, the Y-type perfobond rib shear connectors experience initial plastic slip. However, it remains almost unchanged up to 1.3 million cycles. The residual strength as well as stiffness of Y-type perfobond rib shear connector also remains unchanged even the system endures some permanent plastic slip. 1. INTRODUCTION The steel-concrete composite structures are widely adopted for bridges. Because the shear connecting systems provide the sound structural performance and efficiency in both construction cost and workability in construction sites. The most normally utilized sort of shear connector is headed stud shear connector. The headed stud shear connectors have good workability such as fast welding and easy arrangement of reinforcement. However, stud shear connectors have fatigue problem at connector s root (Ahn et al. 2007) and can not experience the large relative slip between the steelconcrete (Shariati et al. 2012). To improve the disadvantages of stud shear connectors, perfobond rib shear connector has been developed (Zeller 1987). Recently, various types of shear connectors have been introduced (Shariati et al. 2012). Kim et al. (2013) suggested the shear capacity evaluation model for the Y-type perfobond rib shear connectors, in which the conventional perfobond rib shear connectors have been modified to improve the performance such as shear resistance, vertical resistance, ductility and workability for transverse rebar placement. In this study, the permanent 1) Graduate Student 2) Professor 3) Graduate Student 4) Doctor

relative slip of Y-type perfobond rib shear connectors under cyclic loadings is evaluated. 2. BEHAVIOR OF SHEAR CONNECTORS UNDER CYCLIC LOADING 2.1 Plastic slip in composite beam The cyclic loadings can cause permanent slip in connecting part of the shear connectors embedded in the Reinforced Concrete(RC) slab deck. Fig. 1(a) shows the composite girder without loadings, and Fig. 1(b) shows the composite girder under loading. Before loading, point B and C have same distance L. When the force P is applied point B moves and point C moves. The difference between point B and C is called the slip. When slip is completely prevented, it is called the "full composite action". However, in practice certain amount of slip is unavoidable. Therefore, the full composite action is very difficult to achieve. This slip may cause additional deflection, bending stress, and degrading stiffness of connecting part. (a) Composite girder without loading (b) Composite girder under loading Fig. 1 Slip in composite girder 2.2 Slip of the stud shear connector Hanswille et al. (2006) proposed some equations related to the fatigue behavior of the stud shear connectors based on the results of the 71 push-out tests presented in the earlier companion papers. Hanswille et al. (2006) reanalyzed push-out tests to determine the fatigue life of stud shear connector embedded in solid RC slabs and developed empirical expressions to predict the fatigue life and the residual static strength after high cycle pre-loading. Hanswille et al. (2006) has proposed Eq. (1) through (5) for evaluating the plastic slip of stud shear connectors based on the results of the push-out tests presented in

the earlier companion papers. According to the equations, the plastic slip is affected by the load range, load cycles and shear resistance. ( ) (1) (2) (3) (4) { ( ) } (5) where, (mm) is the plastic slip, (kn) is the minimum load, and are the empirical parameters, is the load cycles, is the fatigue life, (kn) is the residual strength, (kn) is the shear resistance, (kn) is the maximum load and (kn) is the load range. 3. CYCLIC LOADING TEST Cyclic loading tests are conducted over 650 thousand cycles for all specimens (Ytype-A, B, C). The cyclic loading tests has been continued up to 1.3 million cycles with the specimen, that has resulted in the maximum slip after 0.65 million cycles (Y-type-B). The load range of cyclic loading test is selected in accordance with the Korean Highway Bridge Specification (KHBS) (MOCT 2010). 3.1 Fabrication of specimens In this study, a total of four specimens are fabricated according to the standard push-out test specimen presented in Eurocode-4 (CEN 2007) to evaluate the relative slip of Y-type perfobond rib shear connector. The design variables of specimens are as follows : the concrete strength is set to 30 MPa, the Y-shaped angle is set to 60 degrees and the number of ribs is set to four. The diameter of dowel holes is 40 mm and the thickness of the rib is 10 mm. The transverse rebar have a diameter of 16 mm. Table 1 summarizes the design variables of the specimens. A 70 mm long styrofoam is attached at the bottom end of the rib of the shear connector to prevent concrete from pouring in. Also, to remove the adhesive force caused by the chemical bonding between the concrete and steel rib, grease is applied to the steel rib before pouring the concrete. Fig. 2 shows the details of specimen.

Table 1 Design variables of specimen Design variables Compressive strength of concrete Number of ribs Thickness of RC slab Width of RC slab Length of RC slab Diameter of dowel hole Diameter of transverse rebar 30 MPa Four 280 mm 600 mm 750 mm 40 mm 16 mm 3.2 Determination of load range for cyclic loading tests The load range of the cyclic loading test is estimated based on the design dead load and live load in accordance with the KHBS (MOCT 2010). According to the Korean Highway Bridge Manual(KHBM) (MOCT 2008), the general span length of a composite girder bridge is 25m to 45m. Therefore, the span length of bridge is determined as 40m in this study. The minimum shear force of 30kN per meter is generated by a dead load, and the maximum shear force of 200kN per meter is generated by live load and dead load. In order to consider the ultimate condition, the maximum load is set to 1.5 times the shear force. Finally, the load range for the cyclic loading test was set as shown in Table 2. Table 2 Load range for cyclic loading test Minimum load Maximum load Load range 30 kn 300 kn 30 ~ 300 kn 3.2 Determination of load range for cyclic loading tests A total of 650 thousand cycles are applied to the specimens. The cyclic loading tests has been continued up to 1.3 million cycles with the Y-type-B specimen, that has resulted in the maximum slip after 0.65 million cycles. Table 3 shows the load range and the number of cycles for the residual strength tests. During cyclic loading tests, slip and stiffness are measured every 10 thousand cycles. A L-shaped angle is attached at middle of the RC slab and four 50 mm Linear Variable Differential Transformer(LVDT)s are installed to measure the slip between the concrete and steel. Fig. 3 shows the setup of the cyclic loading tests.

Category Table 3 Load range and cycles for cyclic loading test Note Load range Cycles 30 ~ 300 kn Y-type-A Y-type-B Y-type-C Specimen that has resulted in the maximum slip after cycles Refer to KHBS (MOCT, 2008) Frequency : 1 Hz Styrofoam (a) Front view(unit : mm). (b) Side view(unit : mm). Styrofoam (c) Plain view(unit : mm). (d) Details of connector(unit : mm). Fig. 2 Layout of specimen

Fig. 3 Test set up of cyclic loading test 4. RESULT OF CYCLIC LOADING TEST The results of the cyclic loading tests are shown in Table 4 and Fig. 4. During the additional 650 thousand cycles, the slip of the Y-type-B connector increased by 0.01 mm. The slip of the Y-type-A specimen increased up to 70 thousand cycles and then increased slowly from 70 thousand cycles to 500 thousand cycles. It remained almost unchanged afterwards. In the Y-type-B specimen, the slip increased sharply at 70 thousand cycles and then remained relatively constant up to 1.3 million cycles. The slip of the Y-type-C specimen increased up to 100 thousand cycles and remained almost unchanged thereafter. The Y-type-B specimen is taken as a representative specimen of Y-type perfobond rib shear connectors. The characteristics of the stud shear connector follow the equations proposed (Hanswille et al. 2006). The numerical value of load range and shear resistance in the equations are the same as that of the Y-type perfobond rib shear connector. Therefore, the characteristics of stud shear connector can be compared with Y-type perfobond rib shear connector. Under repeated loading, the specimen Y-type-A and C experience slightly large slip in the early stage and the slips are always lower than stud shear connectors. The early stage slip of Y-type-B specimen is greater than that of the stud shear connector, but it remains almost unchanged up to 1.3 million cycles. The stud shear connectors undergoes gradual increasing slip even though the permanent slip in the beginning stage is smaller, but it becomes larger than specimen Y-type-B after half million cycles. Fig. 5 shows the relationships between the slip and the loading cycles for the Y-type perfobond rib shear connector and the stud shear connector.

Table 4 Results of cyclic loading tests Cycles ( Specimens Slip Y-type-A 0.37 mm 650 Y-type-B 0.39 mm Y-type-C 0.24 mm 1,300 Y-type-B 0.40 mm 0.5 0.4 Slip (mm) 0.3 0.2 0.1 Y-type-A Y-type-B Y-type-C 0 0 100 200 300 400 500 600 700 Cycle ( 10 3 ) Fig. 4 Slip-loading cycle relationships of Y-type perfobond rib shear connectors Slip (mm) 0 0.1 0.2 0.3 0.4 Stud (Hanswille, 2006) Y-type-A Y-type-B Y-type-C 0.5 0.6 0 200 400 600 800 1000 1200 1400 Cycle ( 10 3 ) Fig. 5 Slip-loading relationships of Y-type perfobond rib shear connectors and stud shear connectors

5. CONCLUSION The relative slip amplitude of Y-type perfobond rib shear connectors under cyclic loading is estimated. Under the repeated loadings, the permanent plastic slips between the Y-type perfobond rib shear connectors and RC slab are monitored. It is found that the Y-type perfobond rib shear connectors provide smaller permanent plastic slip than the stud shear connectors. Even though the plastic slip of the Y-type perfobond rib shear connector increases sharply in the initial stage, it remains unchanged upto 1.3 million cycles. The plastic slip in the system with the stud shear connectors increases gradually and becomes larger after about 0.5 million cycles. REFERENCES Ahn, J.H., Kim, S.H., and Jeong Y.J. (2007), Fatigue experiment of stud welded on steel plate for a new bridge deck system, Steel Composite Structure, 7(5), 391-404. EN 1994-1-1 (2007), Design of composite steel and concrete structures part1-1: General rules and rules for buildings, CEN, Brussels. Hanswille, G., Porch, M. and Ustundag, C. (2006), Resistance of headed stud subjected to fatigue loading Part II: Analytical study, Journal of Construction Steel Research, 63, 485-493. Kim, S.H. Choi, K.T. Park, S.J. Park, S.M. and Jung, C.Y. (2013), Experimental shear resistance evaluation of Y-type perfobond rib shear connector, Journal of Constructional Steel Research, 82, 1-18. Ministry of Construction and Transportation (2008), Korean Highway Bridge Manual, MOCT, Korea. Ministry of Construction and Transportation (2010), Korean Highway Bridge Specification, MOCT, Korea. Shariati, A., RamliSulong, N.H., MeldiSuhatril and Shariati, M. (2012), Various types of shear connectors in composite structures: a review, International Journal of Physical Sciences, 7(22), 2876-2890. Zeller, W. (1987), Recent designs of composite bridges and a new type of shear connectors, Composite Construction in Steel and Concrete, American Society of Civil Engineers, New York.