PoDFA The complete solution for inclusion measurement Inclusion identification and quantification analysis

Similar documents
Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

ABB MEASUREMENT & ANALYTICS. AlSCAN and AlSCAN Argon Hydrogen analysis in liquid aluminum

LiMCA CM. Liquid Metal Cleanliness Analyzer for Continuous Monitoring

LiMCA III Liquid Metal Cleanliness Analyzer

Liquid Metal Cleanliness Analyzer for Continuous Monitoring

Measurement & Analytics Measurement made easy. TALYS ASP310 An affordable high precision wet bath monitoring analyzer

Keeping ahead through Claisse expertise in sample preparation by fusion. Get ready for high productivity!

Keeping ahead through Claisse expertise in sample preparation by fusion. The standard in sample preparation by fusion

INVESTIGATIONS OF THE NATURE OF NON-METALLIC INCLUSIONS IN Al-Mg-Mn ALLOYS

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5009 Fast process gas chromatograph

KEEPING AHEAD THROUGH CLAISSE EXPERTISE IN SAMPLE PREPARATION BY FUSION. A class of its own

Measurement & Analytics Measurement made easy. HP30 on-line process hydrogen analyzer Refinery hydrogen optimization

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5007 Total sulfur analyzer

Start-Up Procedure For Model EM-46, EM-810

Research on importance of cleanliness in manufacturing reliable products for automotive

Technical Note Ref: MH002/01 March 2005

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.

flow rates filtration degrees water for cleaning minimum operating pressure micron less than 1% of the total flow

EBS Filters. The largest automatic self-cleaning filter for fine filtration. features: up to 7200 m³/h (32000 US gpm) less than 1% of the total flow

INSURAL* ATL INSULATING REFRACTORY LADLE LININGS FOR ALUMINIUM AND ZINC

6515 Series Measurement of CO2 in Flue Gases. A simple Katharometer-type measuring system for CO2 in flue gases as a guide to combustion efficiency

Characterisation of Molten Metal Quality Using the Pressure Filtration Technique

33Strongest Molten Metal Filter Material Available. 33Cut Finishing Room Cycle Time & Cost. 3 3 Significantly Reduce Airborne Particulate Emissions

Measurement & Analytics Measurement made easy. Advanced spectroscopy software for quantitative and qualitative analysis Horizon MB FTIR

ABB MEASUREMENT & ANALYTICS DATA SHEET / 7660 series ph / Redox (ORP) electrode systems

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

EXCEL E is used for melting, holding and melt/holding of aluminum alloys in electric resistance and gas-fired furnaces.

ABB MEASUREMENT & ANALYTICS DATA SHEET. AW400 Residual chlorine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX587 ph / Redox (ORP) sensor

Analyzer products Btu options Sampling accessories

ABB MEASUREMENT & ANALYTICS DATA SHEET. SCK Sampling system for dry gas sampling at rotary cement kiln gas exit and calciner gas exit

MeltMap Audit - Assessing metal quality in aluminium foundries

Steam balancing with the flowmeters VortexMaster and SwirlMaster

EXPERIENCE WITH THE SEALED ALCAN COMPACT DEGASSER (ACD)

Compressed Air Filters Sample Filters

The MetalHealth K-Mould as a Monitoring Tool for Molten Metal Quality. Contents. Abstract. Introduction. Discussion. > Abstract.

Ronningen-Petter. Mechanically Cleaned Filter Systems

ULTRA-FILTER COMPRESSED AIR FILTERS DF SERIES. Compressed Air & Process Filtration

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

RATSTM REDUCED ATMOSPHERE TESTING SYSTEM INSTRUCTION & SERVICE MANUAL

Oil-Free Rotary Screw Air Compressors kw Horsepower

Zirconia Oxygen Analyzer

4690 Series Turbidity systems. Accurate, reliable turbidity measurement

MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications

INSULATING REFRACTORIES

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Engineering Guide For Zircoa s Foundry Crucibles

Dr. M. Medraj Mech. Eng. Dept. - Concordia University Mech 421/6511 lecture 12/2

Producing gloss extruded shape products for special applications -Experience from practice-

Hydrazine, sodium and dissolved oxygen measurement The power of boiler chemistry

METAL QUALITY COMPARISON OF ALCAN COMPACT DEGASSER AND SNIF AT ALCOA MOUNT HOLLY CASTHOUSE

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

Cast Steel Filtration Trials Using Ceramic-Carbon Filters

Robust flue gas probes for industrial emissions measurements.

Ti Titanium. Leading the Way in the Production of Plasma Atomized Spherical Metal Powders. Specialists in Powders for Additive Manufacturing

Inventor: Christopher P. Boring CERMET CRUCIBLE FOR METALLURGICAL PROCESSING. DOE Docket S-7 9,301 DISCLAIMER

GAA330-M Emission monitoring system for marine applications

GASTEC AND DENSITEC. Reduced Pressure Test and Density Index. Process Control for Porosity

5000TOCi with ISM. Fast, Continuous and Reliable Total Organic Carbon Measurement

VAPORIZER PRODUCTS. Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U.S.A.

Engineering Excellence

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

MD EMC. Analysis & Control. Hydrogen in liquid aluminium HYCAL

Filters & Elements. People. Passion. Performance

ScreenMaster RVG200 Paperless recorder

INTERDEPENDENCE BETWEEN COOLING RATE, MICROSTRUCTURE AND POROSITY IN MG ALLOY AE42

Model FDL 115 Safety drying chambers for limited quantities of solvent

Thermocouple Quick Reference Guide. Aluminium Temperature Sensing Solutions from the Smelter to the Foundry

Keeping ahead through Claisse expertise in sample preparation by fusion. Let the rfusion system work for you!

Efficiency in Steel Melting: Ladle Development

Line filters LINE FILTERS

NITROGEN SERIES COMPRESSOR SYSTEMS

Maximising Filter Efficiency: Gasketing and Recombination of Flow

Filters & Elements. People. Passion. Performance

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity

industry revolves around VAF Series Compressed Air Filters CFM

Stability test and plant growth chembers. EKOCT - EKOCTL - EKOCH - EKOCHL Series

Markes International Thermal Desorption G8125A, G8126A, G8127A, G8128A, G8131A, G8132A, G8136A, G8133A, MKI-MicroC Site Preparation Checklist

true grit minerals CUMI lative range of EMD PRODUCT CATALOG 100 years US $ 3 billion 29 companies +30,000 people MURUGAPPA GROUP

The most energy efficient compressed air filters in the world.

REFRACTORY CERAMIC FIBER TEXTILE

Improving Melting Efficiency Through the Application of New Refractory Materials

Model TEM Mill. Tabletop precision preparation for producing high-quality TEM specimens from a wide variety of materials EXCELLENCE MAGNIFIED

Sievers M9 TOC Analyzers

TRICON DOUBLE-CON PLUS

CLEANLINESS OF CONVENTIONALLY DEOXIDIZED AND CALCIUM TREATED LOW CARBON STEEL

Slurry-Based Semi-Solid Die Casting

MATERIALS OF CONSTRUCTION

20 21,250 SCFM GLOBAL AIR TREATMENT. CFL Series

Line filters LINE FILTERS

HIGH EFFICIENCY FILTERS FOR COMPRESSED AIR PURIFICATION. Filtration & System solutions. AIR VIP EvO

Degassed Cation Conductivity

NITROGEN SERIES COMPRESSOR SYSTEMS

Pioneering ALD experience since The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

CFF Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System USER MANUAL SITE REQUIREMENTS WASHER-DISINFECTOR ENDOSCOPE DISINFECTION SYSTEM - NORTH AMERICA

Transcription:

Measurement & Analytics Measurement made easy PoDFA The complete solution for inclusion measurement

The complete solution for inclusion measurement Today s global marketplace has compelled aluminum producers and aluminum foundries to produce the highest quality aluminum and shape castings. The most effective means of attaining superior levels of quality is expertise in process coupled with systematic measurement for controlling the melt quality at all stages of manufacturing. 2 The complete solution for inclusion measurement PoDFA PoDFA is a proprietary technology for melt cleanliness evaluation that provides information on the composition and concentration of the inclusions in molten aluminum. PoDFA has already demonstrated its great potential for process characterization and optimization, as well as product improvement. For example, you can quickly and accurately assess the effects of various operating practices on metal cleanliness or identify filtration efficiency. Using PoDFA is an essential key to producing high quality castings.

Filter Inclusion Disc PoDFA technology Two simple steps : sampling and metallographic analysis A predetermined quantity of liquid aluminum is filtered under controlled conditions using a very fine porosity filter. Inclusions in the melt are concentrated at the filter surface by a factor of about 10,000. The filter, along with the residual metal, is then cut, mounted and polished before being analyzed under an optical microscope by a trained PoDFA metallographer. Vacuum The PoDFA technology has never been so accessible! All you have to do is take metal samples using the PoDFA-f system and then choose between two analysis options. You can either obtain a PoDFA license and perform your own metallographic analysis in house, or you can employ ABB s Metallographic Analysis Service on a per-sample basis with no license fee. The second option enables you to access the PoDFA technology at your own pace and capacity. PoDFA-f system Portable low-cost equipment for molten aluminum sampling The PoDFA-f system includes all the equipment required for PoDFA sampling in molten aluminum : a PoDFA-f sampling station, crucible heater, crucibles and filters as well as other facilitating tools described below. The equipment is compact, portable and economical. It can be easily installed where the sampling is conducted. Sampling is straightforward : the operator pours some metal in a crucible, presses the start button and that s it! A vacuum forces the metal to flow through the porous filter. After the test, typically after five minutes, the metal sample is allowed to solidify and saved for metallographic analysis. PoDFA-f System PoDFA reusable crucibles and filters The PoDFA reusable crucible is designed to better respond to the needs of cast houses and foundries by decreasing operational costs and labor time. Filter on ceramic disk: We now offer filters mounted on ceramic disk. They can reduce preheating time of 10 minutes and the use of an expendable material as gasket greatly reduces the risk of leak when pouring molten metal in the crucible. The patented reusable crucible can last for up to 100 samples. It employs a, ready-to-use filter for every test and can be installed in seconds. Thanks to this leading-edge design, the filter detachment problem has been virtually eliminated as the filter is literally cast into the aluminum. PoDFA The complete solution for inclusion measurement 3

Metallographic Analysis Results Inclusion Content (mm 2 /kg) MgO-Cuboids Refractories Carbides > 3um Potential Chlorides Spinels TiB2 MgO Carbides > 3um Oxide Films Oxide film content (#/kg) Exit Furnace After Degaser After CFF Metallographic analysis Trolley Metal sample holder PoDFA metallographic analysis ABB metallographic analysis service You do the sampling; we take care of the analysis. Take samples quickly and easily using the PoDFA-f system. Identify each metal residue indicating the sampling information and then send all samples by express mail to our PoDFA metallographic analysis service. You will receive a report with the key residue pictures and a breakdown of each inclusion type expressed in mm 2 /kg of aluminum. All information is strictly confidential and reports are produced in less than two weeks. There is no license fee; you pay on a per-sample basis. PoDFA can effectively assess the effects of various operating practices and melt treatments on metal cleanliness. The histogram shown at left is a good example of PoDFA results during the different stages of a process. The samples taken at the furnace exit contain a high level of carbides, magnesium oxides, refractory materials and oxide films. After degasser, the concentration of inclusions decreased while the oxide films increased, most probably due to an excess of turbulence in the degassing chamber. Finally, the results demonstrate that the ceramic foam filter is effective in removing both inclusions and oxide films. Inclusions concentration decreased from about 0.3 mm 2 /kg to less than 0.1 mm 2 /kg and oxide films from about 100 per kg to less than 10 per kg. Practical accessories Reusable crucible trolley for safe cooling and easy carrying Metal sample holder for safe aluminum residue cutting on a band saw 4 The complete solution for inclusion measurement PoDFA

Magnification of inclusion Annual contracts for volume users Volume customers who regularly employ ABB s PoDFA metallographic analysis services can take advantage of significant price reductions by signing an annual contract. Savings vary depending on the quantity, report content and sample preparation required. Annual contracts also offer an excellent alternative to licensed PoDFA users. As PoDFA metallographic analysis calls for expertise, time and accuracy, outsourcing to a highly specialized laboratory is the ideal solution for many aluminum plants. Rio Tinto Alcan metallographic analysis technology transfer Over 30 years of knowledge at your fingertips PoDFA technology transfer and analysis training are available from ABB. For those who prefer to do more than just the sampling, the vast body of knowledge of Rio Tinto Alcan is readily transferable to your organization. It includes metallographic training and a CD-ROM that contains a catalog of inclusions as well as methods. This valuable information has been optimized for over 30 years by Rio Tinto Alcan on a wide variety of alloys. Additional PoDFA training Standard and advanced training sessions are available for PoDFA registered users. The PoDFA technology is the property of Rio Tinto Alcan International Limited, and is licensed for manufacturing to ABB. Patent 5,827,982. Reusable Crucible RTA Patent 7,472,613 PoDFA The complete solution for inclusion measurement 5

Photos are courtesy of Alcan Inc. PoDFA-f sampling station Mass measurement Mass 0 to 5 kg ± 0.02 kg Important : Mass over 8 kg can damage the load cell Target mass Selectable to 1.50, 1.25, and 1.00 kg Display 3 1/2 digits, 12.7 mm (0.56 in.) high LEDs Electrical Rated line voltage Rated line frequency Rated line power Fuse type 100 to 240 VAC (self adjusting) 50/60 Hz 11 VA at 100V 34 VA at 240V T2A/250V Compressed air requirements Inlet pressure 5.5 to 8.25 bar (80 to 120 psig) Important : To avoid damaging the solenoid valve, do not exceed 10 bars (150 psig) Air purity Dry air, minimum dew point -40 C (-40 F) Air should be cleaned and uncontaminated Filtered to 40 microns or better Air temperature Below 35 C (95 F) Air fitting 1/4 NPT female Air consumption (at 100 PSI) Vacuum : 340 l/min (12 SCFM) Cooling : 665 l/min (23.5 SCFM) Physical Overall dimensions (WxDxH) 33 cm x 29.5 cm x 39.4 cm (13 in. x 11.63 in. x 15.53 in.) Weight 18.0 kg (39.5 lb.) Environmental Storage temperature range -10 C to 75 C (14 F to 167 F) Operating temperature range 10 C to 50 C (50 F to 122 F) Storage humidity range Up to 60 % (non condensing) Operating humidity range Up to 90 % (non condensing) Sound pressure level Distance from the instrument Approximate sound instrument pressure level in vacuum mode at the instrument 118 dba at 1 m (39 in) 100.1 dba at 5.1 m (17 feet) 85 dba 6 The complete solution for inclusion measurement PoDFA

PoDFA reusable crucible and filter General Crucible heating time on the crucible heater When crucible heater is hot: Typically 20-25 minutes When crucible heater is cold: Typically 30 minutes Important: Typical times are based on normal room temperature, no forced convection around the equipment and the use of an insulation blanket over the crucible. Crucible lifetime Up to 100 tests when following the proper preparation and manipulation procedure described in the PoDFA-f System User s Guide Crucible protective coating Needs to be redone every 15 to 20 tests Important: Crucible lifetime is dependent on the protective coating. Carefully follow the procedure described in the User s Guide. Physical Crucible Filter Overall dimensions OD: 13.3 cm (5-1/4 in.) Height: 20.3 cm (8 in.) Weight 1.36 kg (3 lb) Materials Outer shell: Carbon steel Aluminum and silica Inner shell: Stainless steel Insulation: Synthetic Vitreous Fiber (SVF) blanket Packaging information 3 crucibles per box 24 filters per box Crucible Heater Heating time 0 to 6 hours (adjustable timer) Electrical requirements Rated input voltage Rated input frequency Earth leakage Rated input current Fuse type 100-120 / 220-240 VAC (factory set) 50 / 60 Hz Less than 50mA 4A at 230 VAC, 7A at 115 VAC T4A/250V at 230 VAC, T7A/250V at 110 VAC Environmental Operating temperature 10 C to 50 C (50 F to 122 F) Storage temperature -10 C to 75 C (14 F to 167 F) Operating humidity Up to 90% (non condensing) Storage humidity Up to 60% (non condensing) Physical Overall Dimensions (H x W x D) 35 cm x 29 cm x 21 cm (13-1/2 in. x 11-1/2 in. x 8-1/4 in.) Weight 5.6 kg (12 lb.) Environmental Storage temperature range -10 C to 75 C (14 F to 167 F) Storage humidity range Up to 60% (non condensing) PoDFA reusable crucible and filter Crucible Heater PoDFA The complete solution for inclusion measurement 7

Contact us ABB Inc. Process Automation Measurement & Analytics 3400, Rue Pierre-Ardouin Quebec (Quebec) G1P 0B2 Canada Tel.: +1 418 877-2944 1 800 858-3847 (North America) Fax : +1 418 877-2834 E-Mail: metal@ca.abb.com www.abb.com/analytical Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2016 ABB All rights reserved 9AKK104295D6917 PB/PoDFA-EN Rev. A 01.2016 Sales Service