Instrumentation Cables

Similar documents
Construction guideline

INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES

Comparison of BS 5308, PAS 5308 and BS EN

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

SPECIFICATION FOR FRLS POWER CABLES

SafeX110 Single Core Flexible Tinned Copper Cable

Instrumentation and Thermocouple Cables

Instrumentation and Thermocouple Cables

26/35kV Copper XLPE Insulation Electric Cable

Armoured Instrumentation Cables to BS7917

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

Copper Cable Company Limited

MATERIAL STANDARD FOR CABLES AND WIRES

Caledonian Cables Ltd

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

Separator, suitable tape between the braid and outer sheath

DATA SHEET Single Core 2HR Fire Rated Cable

H-FLEX CABLES 10/2017

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

Low Smoke Halogen Free cables

Compact Module. Enhanced Category 5 FTP Cabling System

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152

Cables for Railway Signalling Applications General Requirements

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

U.V resistance UL Sunlight Resistance. Flame retardant IEC

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

Test Report No.: Page 2 of 35

Cables de Comunicaciones Zaragoza. CW1601 Approval application.

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

SOUTH AFRICAN NATIONAL STANDARD

7. EXTENSION LEADS AND COMPENSATING CABLE

INTERNATIONAL STANDARD

Engineering Data for Copper and Aluminum Conductor Electrical Cables

EHV XLPE CABLES CDCC LINE


Electric cables. CRANES APPENDIX

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media

Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers

NPS/002/023 Technical Specification for 132kV Power Cables.

11-SDMS-01 REV. 03 ( )

List Price w.e.f. 24th July, 2018

List Price w.e.f. 02nd January, 2018

Data sheet chainflex CF887

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Building Wire CARRYING YOUR ELECTRICITY

Detailed Specifications & Technical Data

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

LOW VOLTAGE POWER CABLE

FieldLink for PROFIBUS Applications

40/69 kv to 127/220 kv XLPE

SUBMERSIBLE. Electric cables

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

P.V.C. INSULATED UNARMOURED COPPER CABLES

according to UL AWM 758, Style and based on EN resp. VDE

Rail Wire Guide. Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... LFH FREE

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Una e mpre sa Vi akab l e GLOSSARY.

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

Single core conductor BETAtherm 145

Fire Resistant Cable (FRC) Flexible Fireproof Cable (FFC) Mineral Insulated Cable (MIC)

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Content HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables

INTERNATIONAL STANDARD

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6


SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

PV Solar Wiring Solutions

AMWAJ TELECOMMUNICATION FACTORY

Data sheet chainflex CFSPECIAL.182

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

Technical Specification for Plastic-Insulated Low Voltage Cables

M-FLEX CONTROL CABLES

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

SERV-RITE Wire and Cable

Transcription:

Instrumentation Cables Product Catalogue

Factories and Regional Offices Tai Sin Electric Limited 24 Gul Crescent Jurong Town Singapore 62953 Tel: (+65) 6672 9292 Fax: (+65) 686 4084 E-Mail: sales@taisin.com.sg Website: www.taisin.com.sg Tai Sin Electric Cables (Malaysia) Sdn. Bhd. PTD 37433, 37434 & 37444 Off Jalan Perindustrian Senai 3 Kawasan Perindustrian Senai Fasa 3 P.O.Box 73, 8400 Senai Johor Darul Takzim, Malaysia Tel: (+60) 7 599 8888 Fax: (+60) 7 599 8898 E-Mail: sales@taisin.com.my Website: www.taisin.com.my Tai Sin Electric Cables (VN) Co., Ltd. No.20, VSIP II Street 2 Vietnam - Singapore Industrial Park 2 Hoa Phu Ward, Thu Dau Mot City Binh Duong Province, Vietnam Tel: (+84) 650 3635 088 Fax: (+84) 650 3635 077 E-Mail: sales@taisin.com.vn Website: www.taisin.com.vn (Updated as at January 205)

CONTENTS INTRODUCTION HOW TO READ THIS CATALOGUE / VARIOUS TYPES OF INSTRUMENTATION CABLES FOUND IN THIS CATALOGUE APPLICABLE STANDARDS 2 3 PVC & XLPE INSULATED INSTRUMENTATION CABLES IN-POP CU / PVC / OS / PVC ( PAIRS & TRIADS ) PVC Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOP CU / PVC / OS / PVC ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-PIOP CU / PVC / IS / OS / PVC ( PAIRS & TRAIDS ) PVC Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOP CU / XLPE / IS / OS / PVC ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-POSP CU / PVC / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) PVC Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOSP CU / XLPE / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-PIOSP CU / PVC / IS / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) PVC Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOSP CU / XLPE / IS / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 4 7 0 3 LOW SMOKE ZERO HALOGEN FLAME RETARDANT INSTRUMENTATION CABLES FRT-XOL CU / XLPE / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 FRT-XIOL CU / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 FRT-XOSL CU / XLPE / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, LSZH bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 FRT-XIOSL CU / XLPE / IS / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable,300 / 500V, BS EN50288-7 6 9 22 25 LOW SMOKE ZERO HALOGEN FLAME RETARDANT FIRE RESISTANT INSTRUMENTATION CABLES FR-XOL CU / MGT / XLPE / OS / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable,300 / 500V, BS EN50288-7 FR-XIOL CU / MGT / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 FR-XOSL CU / MGT / XLPE / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 FR-XIOSL CU / MGT / XLPE / IS / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 APPENDIX A TERMS & CONDITIONS OF SALES 28 3 34 37 40 4

INTRODUCTION Since our incorporation in 980 as Tai Sin Electric Cables Manufacturer Pte Ltd, we have expanded and diversified over the past three decades to establish ourselves as the present Tai Sin Electric Limited. To cater for the robust growth in the regional market, Tai Sin now operates three cable manufacturing plants located in Singapore, Malaysia and Vietnam, all of which are fully equipped with the latest manufacturing facilitates and technologies to meet increasing demands. Tai Sin stocks the widest range of the Power, Control, Instrumentation and Safety Cables for use in all areas of electrical and instrumentation installation for commercial, residential, industrial and infrastructure projects. Our cables and wires are manufactured under strict quality control and designed to perform within fixed parameters of electrical, mechanical and environmental tolerances and we assure you that our products will not present a safety hazard if used with care. For 30 years, we have grown steadily based on a sound business philosophy of providing quality products using leading edge technology, backed by unfailing excellence in customer service and faster turnaround time to maintain customer loyalty. These are the beliefs and values that give us the strength and confidence to continue to grow, excel and succeed in the exciting years ahead. This catalogue feature Single and Multi-pair cables utilized in communication services and the interconnection of electrical equipment and instruments especially in and around process plants. In addition, these cables are also suitable for process control, monitoring applications and telemetering applications which require the interconnection of electrical instruments and control equipment for indoor or underground burials. These cables are not applicable for direct connection low impedance e.g. public main supply. We hope that this catalogue will be useful to engineers and end-users to serve as their full reference guidelines.

HOW TO READ THIS CATALOGUE In this catalogue we have given each cable a name accompanied with the various short and long descriptions based on its material used. For example: FRT-XOL CU / XLPE / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminum Foil Screened, LSZH Sheathed Cable This is the short description Full description on the third line To better understand the contents of the cable, we have included a 3-dimentional image plus a cross-sectional image of the cable for easy reference of its structure and components. The technical specifications and figures are provided by our quality team to ensure the accurate use of our products. Electrical properties such as Insulation Resistance and Mutual Capacitance and other essential technical details are provided in the Appendices at the last section of this catalogue. For all other enquiries, please feel free to contact our friendly customer service hotline for further assistance. VARIOUS TYPES OF INSTRUMENTATION CABLES FOUND IN THIS CATALOGUE Overall Screened Cores (Armoured & Non-Armoured) Cables for this range are customarily used in the process industries (steel, pharmaceutical, petrochemical, paper, mining, etc.) providing control connections for DC or AC networks with an option of a fixed potential, with respect to earth. Applications are found in value and motor control units, auxiliary station controls, circuit breaker indications and operations, etc. Cables in this this category comes in the armoured and non-armoured type for indoor applications. Overall Screened Pairs / Traids (Armoured & Non-Armoured) The cables mentioned here are overall screened to oppose static & crosstalk noises ensuring precise and flawless signals to be transmitted. These cables are recommended where signals transmitted are in excess of 00 millivolts in instrumentation and control applications. Cables of this classification are mainly used for interconnections between sensors, monitors and instruments where 00% shield effectiveness is ensured through our aluminum foil/pet shield with drain wires. Instrumentation cables that are used for indoor applications and unarmoured and cables for direct underground burials are those with steel wire armouring. Individual & Overall Screened Pairs / Traids (Armoured & Non-Armoured) Where noise rejection is essential, individually shielded pairs or triads with an overall shield are recommended. To provide optimal protection from crosstalk and common mode interference, individual pair & traid shields are separated from each other and each contains independent drain wires for grounding. These cables also come with an overall shield for additional electrostatic noise protection. The various types of Instrumentation Cables manufactured may be insulated with our standard PVC, XLPE materials or with our Eco-friendly Non- Toxic Low Smoke Zero Halogen Flame Retardant materials with or without Fire Resistant characteristics. Additionally, our instrumentation cables are available with standard or reduced flame propagation and low acid gas emission PVC sheaths as well as Low Smoke Zero Halogen Flame Retardant materials. Our instrumentation cables are generally manufactured to BS EN50288-7. Should you need alternative constructions for different conductor sizes or pair combinations, we can also manufacture to your specific needs, installation and operating requirements. Our technical personnel will provide the necessary guidance and assistance in designing the cables that will meet your requirements.

APPLICABLE STANDARDS Below are the applicable standards that are used as reference in the construction of our instrumentation cables. ASTM D 2863 Measuring the minimum oxygen concentration to support candle-like combustion of plastic (oxygen index). BS6387 / SS299 Performance requirements for cables required to maintain circuit integrity under fire conditions. BS6724 600 / 000V armoured electric cables having thermosetting insulation and low emission of smoke and corrosive gases when affect by fire. BS72 Thermosetting insulated cables (non-amoured) for electric power and lighting with low emission of smoke and corrosive gases when affected by fire. BS7629-300 / 500V fire-resistant screened cables having low emission of smoke and corrosive gases when affect by fire. Part : Multicore and multi-pair cables. BS7846 600 / 000V armoured fire-resistant electric cables having low emission of smoke and corrosive gases when affected by fire. BS EN50288-7 Multi-element metallic cables use in analogue and digital communication and control. Part 7: Sectional specification for instrumentation and control Cables. BS EN60228 s of insulated cables. IEC6033 Fire-resistant characteristics of electric cables. IEC60332- / BS4066- / BS EN50266- Tests in electric cables under fire conditions. Part : Method of test on a single vertical insulated wire or cable. IEC60332-3 / BS4066-3 / BS EN50266-2 Tests on electric cables under fire conditions. Part 3: Methods of classification of flame propagation characteristics of bunched cables. IEC60502- Power cables with extruded insulation and their accessories for rated voltages from kv up to 30kV. Part : Cables for rated voltage of kv and 3kV. IEC60754- / BS6425- / BS EN50267-2- Tests on gases evolved during the combustion of materials from cables. Part : Methods of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables. IEC60754-2 / BS6425-2 / BS EN50267-2-2 Tests on gases evolved during combustion of materials from cables. Part 2: Determination of degree of acidity (corrosive) of gases by measuring ph and conductivity. IEC6034-2 / BS7622-2 / BS EN6034-2 Measurement of smoke density of electric cables burning under defined conditions. Part 2: Test procedure and requirements.

IN-POP CU / PVC / OS / PVC ( PAIRS & TRIADS ) PVC Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOP CU / XLPE / OS / PVC ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 2 3 4 5 5 3 4 2 Component. Plain Annealed Copper Wire 2. PVC or XLPE 3. Aluminium / Polyester Tape 4. Tinned Copper Drain Wire 5. PVC CONSTRUCTION : Insulation: Insulation Colour: Cores Twisted: Lay Up: Wrap Film: Overall Screen: Outer Sheath: Outer Sheath Colour: Plain Annealed Copper, Class 2 Stranded Circular () Polyvinyl Chloride (PVC) Type TI5 or (2) Cross-linked Polyethylene (XLPE) Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) Flame Retardancy Polyvinyl Chloride (PVC) Type ST2 FR Black or Blue ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: Final Short Circuit Temperature: Test Voltage: REFERENCE STANDARDS Design Specification: : Flame Retardancy: INSTALLATION REFERENCE Min. Bending Radius : Max. Pulling Tension (N/mm 2 ): 50-5ºC to 70ºC (PVC Insulated) -5ºC to 90ºC (XLPE Insulated) 60ºC (PVC Insulated) 250ºC (XLPE Insulated) 2kV for minute BS EN50288-7 IEC60228, BS EN60228 IEC60332-3 8 x cable overall diameter IN-XOP IN-POP Thickness of Insulation (Quad) 3 0.5 7. 8.0 2.6 3.7 5. 6.9 9.3 9.9 22. 24.8 27.7 3.9 58 8 98 26 52 77 2 260 322 364 465 560 669 943 7. 8.0 2.6 3.7 5. 6.9 9.3 9.9 22. 24.8 27.7 3.9 63 90 08 4 7 202 240 300 37 423 533 659 787 2 Table ii

IN-POP CU / PVC / OS / PVC ( PAIRS & TRIADS ) PVC Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOP CU / XLPE / OS / PVC ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOP IN-POP Thickness of Insulation (Quad) 3 5 7.5 8.5 2.3 3.5 4.9 6.2 8.2 20.8 2 24.0 27.0 30. 34.7 66 95 9 48 80 220 253 35 390 444 57 704 840 25 7.5 8.5 2.3 3.5 4.9 6.2 8.2 20.8 2 24.0 27.0 30. 34.7 72 05 30 65 202 247 285 358 444 509 658 82 970 384 (Quad) 3 7 / 043 7.9 9.0 2.3 3.0 4.2 5.8 7.2 9.5 22. 23.0 25.5 28.7 3 36.9 74 08 35 70 207 254 293 378 456 534 674 832 994 46 7.9 9.0 2.3 3.0 4.2 5.8 7.2 9.5 22. 23.0 25.5 28.7 3 36.9 80 20 47 87 23 283 328 424 54 604 767 948 33 626 (Quad) 3 8.5 9.7 3.3 4.2 5.7 7.2 9.0 2.3 24.4 25.2 28.2 3.7 35.4 4. 89 34 64 2 268 39 38 480 595 685 886 094 308 895 8.5 9.7 3.3 4.2 5.7 7.2 9.0 2.3 24.4 25.2 28.2 3.7 35.4 4. 95 47 77 230 294 352 420 532 660 763 990 224 464 228 Table 2

IN-POP CU / PVC / OS / PVC ( PAIRS & TRIADS ) PVC Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOP CU / XLPE / OS / PVC ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOP IN-POP Thickness of Insulation (Quad) 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 9.7.4 5.7 6.8 8.6 20.4 2 2 29.2 30.2 33.8 38.0 4 49.2 7 9 229 300 384 460 548 709 879 05 35 625 94 287 9.7.4 5.7 6.8 8.6 20.4 22.4 25.5 29.2 30.2 33.8 38.0 4 49.2 26 209 247 327 420 505 602 782 970 24 46 807 259 344 Table 3 IN-XOP IN-POP No. of Triads Thickness of Insulation 0.5 7.4 6.8 24.9 3.2 69 276 630 927 7.4 6.8 24.9 3.2 77 320 748 05 SINGLE & MULTI-TRIADS 5 7.9 8.0 27. 34.0 8.3 9.3 28.8 36.2 8.9 2.2 3.9 40.0 80 335 796 72 9 404 946 398 58 254 853 7.9 8.0 27. 34.0 8.3 9.3 28.8 36.2 8.9 2.2 3.9 40.0 88 384 926 367 00 456 086 607 2 576 40 2087 7 / 7 7 / 7 7 / 7 7 / 7 0.5 25.3 38.2 48.2 57 768 872 2790 0.5 25.3 38.2 48.2 7 850 2090 37 Table 4

IN-PIOP CU / PVC / IS / OS / PVC ( PAIRS & TRAIDS ) PVC Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOP CU / XLPE / IS / OS / PVC ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 7 5 6 4 2 3 Component. Plain Annealed Copper Wire 2. PVC or XLPE 3. Tinned Copper Drain Wire 4. Aluminium / Polyester Tape (IS) 5. Aluminium / Polyester Tape (OS) 6. Tinned Copper Drain Wire 7. PVC 2 3 4 5 6 7 CONSTRUCTION : Insulation: Insulation Colour: Cores Twisted: Wrap Film: Plain Annealed Copper, Class 2 Stranded Circular () Polyvinyl Chloride (PVC) Type TI5 or (2) Cross-linked Polyethylene (XLPE) Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Polyester Binder Tape Outer Sheath: Outer Sheath Colour: Flame Retardancy Polyvinyl Chloride (PVC) Type ST2 FR Black or Blue ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: Final Short Circuit Temperature: Test Voltage: -5ºC to 70ºC (PVC Insulated) -5ºC to 90ºC (XLPE Insulated) 60ºC (PVC Insulated) 250ºC (XLPE Insulated) 2kV for minute Individual Screen: Lay Up: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (IS) Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core REFERENCE STANDARDS Design Specification: : Flame Retardancy: BS EN50288-7 IEC60228, BS EN60228 IEC60332-3 Wrap Film: Overall Screen: Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) INSTALLATION REFERENCE Min. Bending Radius : Max. Pulling Tension (N/mm 2 ): 50 8 x cable overall diameter IN-XIOP IN-PIOP Thickness of Insulation 3 0.5 7..3.9 3.0 4.4 5.6 7.7 20.2 2 23. 26.0 29.0 33.5 58 2 5 84 225 259 333 4 469 59 729 870 254 7..3.9 3.0 4.4 5.6 7.7 20.2 2 23. 26.0 29.0 33.5 62 28 6 97 24 279 360 445 509 645 795 95 375 Table 5 ii

IN-PIOP CU / PVC / IS / OS / PVC ( PAIRS & TRAIDS ) PVC Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOP CU / XLPE / IS / OS / PVC ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOP IN-PIOP Thickness of Insulation 3 5 7.5 2.7 4. 5.4 7.0 9.0 2.7 22.4 25. 28.2 3.4 36.4 66 37 74 22 26 3 390 483 553 73 879 049 54 7.5 2.7 4. 5.4 7.0 9.0 2.7 22.4 25. 28.2 3.4 36.4 70 45 85 236 280 333 420 520 598 773 953 39 648 3 7.9 2.6 3.6 4.9 6.2 7.9 20.3 23.0 24.0 26.6 29.9 33.5 38.6 74 53 203 250 296 353 456 552 647 820 03 226 75 7.9 2.6 3.6 4.9 6.3 7.9 20.3 23.0 24.0 26.6 29.9 33.5 38.6 78 6 25 266 37 378 488 592 695 885 093 324 896 3 8.5 3.9 4.8 6.2 7.9 9.5 22. 25.3 26.4 29.3 33. 36.9 42.7 89 90 245 304 373 434 562 696 87 04 302 553 2248 8.5 3.9 4.8 6.2 7.9 9.5 22. 25.3 26.4 29.3 33. 36.9 42.7 93 99 259 323 396 462 599 742 872 4 393 663 243 Table 6

IN-PIOP CU / PVC / IS / OS / PVC ( PAIRS & TRAIDS ) PVC Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOP CU / XLPE / IS / OS / PVC ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOP IN-PIOP Thickness of Insulation 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 9.7 6.3 7.4 9.0 2. 23.2 26.3 30. 3.2 34.9 39.4 43.9 50.8 7 258 339 423 59 68 800 990 46 486 855 222 3207 9.7 6.3 7.4 9.0 2. 23.2 26.4 30. 3.2 34.9 39.4 43.9 50.8 24 272 359 450 553 659 855 059 228 595 990 2376 3452 Table 7 IN-XIOP IN-PIOP No. of Triads Thickness of Insulation 0.5 7.5 6.5 24.4 3 68 37 730 076 7.5 6.5 24.4 3 74 356 835 233 SINGLE & MULTI-TRIADS 5 7.9 7.7 26.5 33. 8.3 8.7 28. 35.4 8.9 2 3. 39.0 79 377 899 324 89 437 052 673 09 56 378 203 7.9 7.7 26.5 33. 8.3 8.7 28. 35.4 8.9 2 3. 39.0 86 42 04 497 97 483 76 756 8 64 57 2240 7 / 7 7 / 7 7 / 7 7 / 7 0.5 24.5 37.0 46.5 55 83 2002 2977 0.5 24.5 37.0 46.5 67 888 220 3275 Table 8

IN-POSP CU / PVC / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) PVC Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOSP CU / XLPE / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 7 5 4 3 6 2 Component. Plain Annealed Copper Wire 2. PVC or XLPE 3. Aluminium / Polyester Tape 4. PVC 5. Galvanised Steel Wire Armoured 6. Tinned Copper Drain Wire 7. PVC 2 3 4 5 6 7 CONSTRUCTION : Insulation: Insulation Colour: Cores Twisted: Lay Up: Plain Annealed Copper, Class 2 Stranded Circular () Polyvinyl Chloride (PVC) Type TI5 or (2) Cross-linked Polyethylene (XLPE) Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Armour: Outer Sheath: Outer Sheath Colour: Galvanized Steel Wire Armoured (SWA) Flame Retardancy Polyvinyl Chloride (PVC) Type ST2 FR Black or Blue ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: Final Short Circuit Temperature: Test Voltage: -5ºC to 70ºC (PVC Insulated) -5ºC to 90ºC (XLPE Insulated) 60ºC (PVC Insulated) 250ºC (XLPE Insulated) 2kV for minute Wrap Film: Overall Screen: Bedding: Bedding Colour: Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) Polyvinyl Chloride (PVC) Type ST2 Black REFERENCE STANDARDS Design Specification: : Flame Retardancy: INSTALLATION REFERENCE Min. Bending Radius : BS EN50288-7 IEC60228, BS EN60228 IEC60332-3 0 x cable overall diameter Max. Pulling Tension (N/mm 2 ): 70 IN-XOSP IN-POSP Thickness of Insulation Under Armour Armour Wire Cable Overall Approx. Cable Overall Approx. (Quad) 3 0.5 7 / 03 7.2 8. 0.8.4 3.6 4.8 6.6 8.8 9.4 2 24. 26.8 30.8.9 2.7 5.7 6.3 7.4 8.5 2 22.4 24.6 25.4 27.6 30.3 33.0 37.2 264 308 398 434 487 54 74 84 940 008 75 357 539 939.9 2.7 5.7 6.3 7.4 8.5 2 22.4 24.6 25.4 27.6 30.3 33.0 37.2 269 38 408 449 507 565 743 854 989 068 252 455 657 26 Table 9 ii

IN-POSP CU / PVC / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) PVC Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOSP CU / XLPE / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOSP IN-POSP No. of Pairs Thickness of Insulation Under Armour Armour Wire Cable Overall Approx. Cable Overall Approx. (Quad) 3 5 7 / 037 7.6 8.6 2.2 3.4 4.6 5.9 7.9 20.3 2 23.3 26. 29.0 33.4 2.3 3.2 6.4 7. 8.3 20.4 2.7 23.7 26.3 27.0 2.3 32.3 35.4 4 280 336 433 477 537 7 782 907 070 39 327 549 775 2499 2.3 3.2 6.4 7. 8.3 20.4 2.7 23.7 26.3 27.0 29.3 32.3 35.4 4 286 346 444 493 559 738 85 950 24 204 44 657 905 2694 (Quad) 3 8.0 9. 2.2 2.9 4. 5.5 6.9 9.0 2 22.3 24.8 27.8 3 35.6 2.7 3.9 7. 7.8 9.9 2.3 22.7 25.0 27.6 28.3 3 34.0 37.3 42.9 296 365 464 58 693 77 859 00 74 265 495 727 990 2803 2.7 3.9 7. 7.8 9.9 2.3 22.7 25.0 27.6 28.3 3 34.0 37.3 42.9 302 376 475 536 77 80 894 056 233 334 588 844 229 303 (Quad) 3 8.6 9.8 3.2 4. 5.4 6.9 8.5 20.8 23.7 24.5 27.3 3 34. 39.8 3.3 4.6 8. 9.9 2.2 22.7 24.5 26.8 29.9 3 33.5 37.0 4.4 47.3 329 4 59 696 785 885 000 73 380 494 769 2209 2637 3475 3.3 4.6 8. 9.9 2.2 22.7 24.5 26.8 29.9 3 33.5 37.0 4.4 47.3 336 424 532 76 8 98 039 225 445 572 873 2079 2793 3709 Table 0

IN-POSP CU / PVC / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) PVC Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOSP CU / XLPE / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XOSP IN-POSP No. of Pairs Thickness of Insulation Under Armour Armour Wire Cable Overall Approx. Cable Overall Approx. (Quad) 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 9.8.3 5.4 6.5 8. 9.9 2.8 24.6 28. 29. 3 36.9 4.2 47.5 4.7 6. 2.2 22.3 24. 25.9 27.8 30.8 34.5 35.5 39.8 44.4 48.9 56.2 394 499 746 853 990 27 256 506 789 960 2587 308 3586 5066 4.7 6. 2.2 22.3 24. 25.9 27.8 30.8 34.5 35.5 39.8 44.4 48.9 56.2 403 56 764 88 026 73 3 579 880 2070 2733 3209 3805 5394 Table IN-XOSP IN-POSP No. of Triads Thickness of Insulation 0.5 2.2 22.3 30.4 36.5 282 830 427 899 2.2 22.3 30.4 36.5 290 877 554 2090 SINGLE & MULTI-TRIADS 5 2.7 23.5 32.4 39.8 3. 24.8 34. 42.2 3.9 26.7 37.2 46.4 302 926 642 244 325 035 853 2765 367 20 2250 345 2.7 23.5 32.4 39.8 3. 24.8 34. 42.2 3.9 26.7 37.2 46.4 30 979 78 2650 334 09 2002 2990 377 273 247 3666 7 / 7 7 / 7 7 / 7 7 / 7 5.3 3 44.6 55.2 443 563 3357 5007 5.3 3 44.6 55.2 457 65 3589 5356 Table 2

IN-PIOSP CU / PVC / IS / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) PVC Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOSP CU / XLPE / IS / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 9 7 6 5 8 4 2 3 5 6 7 8 Component 9. Plain Annealed Copper Wire 2. PVC or XLPE 3. Tinned Copper Drain Wire 4. Aluminium / Polyester Tape (IS) 5. Aluminium / Polyester Tape (OS) 6.. PVC 7. Galvanised Steel Wire Armoured 8. Tinned Copper Drain Wire 9. PVC 2 3 4 CONSTRUCTION : Insulation: Insulation Colour: Cores Twisted: Wrap Film: Individual Screen: Lay Up: Wrap Film: Overall Screen: Bedding: Plain Annealed Copper, Class 2 Stranded Circular () Polyvinyl Chloride (PVC) Type TI5 or (2) Cross-linked Polyethylene (XLPE) Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (IS) Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) Polyvinyl Chloride (PVC) Type ST2 Bedding Colour: Armour: Outer Sheath: Outer Sheath Colour: Black Galvanized Steel Wire Armoured (SWA) Flame Retardancy Polyvinyl Chloride (PVC) Type ST2 FR Black or Blue ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: Final Short Circuit Temperature: Test Voltage: REFERENCE STANDARDS Design Specification: : Flame Retardancy: INSTALLATION REFERENCE Min. Bending Radius : Max. Pulling Tension (N/mm 2 ): 70-5ºC to 70ºC (PVC Insulated) -5ºC to 90ºC (XLPE Insulated) 60ºC (PVC Insulated) 250ºC (XLPE Insulated) 2kV for minute BS EN50288-7 IEC60228, BS EN60228 IEC60332-3 0 x cable overall diameter IN-XIOSP IN-PIOSP No. of Pairs Thickness of Insulation Under Armour Armour Wire Cable Overall Approx. Cable Overall Approx. 3 0.5 7.2.2.8 2.9 4. 5.3 7.2 9.5 20.2 22.4 25. 27.9 3.9 6. 6.7 7.8 9.9 2. 23.2 25.5 26.2 28.6 3.3 34.3 39.3 264 428 472 533 703 775 93 056 28 337 549 779 2490.9 6. 6.7 7.8 9.9 2. 23.2 25.5 26.2 28.6 3.3 34.3 39.3 269 438 487 553 728 805 954 06 88 47 649 900 2670 Table 3 ii

IN-PIOSP CU / PVC / IS / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) PVC Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOSP CU / XLPE / IS / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOSP IN-PIOSP No. of Pairs Thickness of Insulation Under Armour Armour Wire Cable Overall Approx. Cable Overall Approx. 3 5 7.6.9 2.6 3.8 5. 6.5 8.5 2 2.7 24.2 27. 30. 35. 2.3 6.8 7.5 8.9 2 2 24.5 27.2 27.9 30.4 33.5 36.7 42.6 280 459 50 593 766 868 009 80 274 498 763 2024 2902 2.3 6.8 7.5 8.9 2 2 24.5 27.2 27.9 30.4 33.5 36.7 42.6 286 470 527 65 794 90 053 235 340 586 873 255 300 3 8.0 3.3 4.6 5.9 7.4 9.6 22.3 23. 25.7 28.8 3 37.3 2.7 7.4 8.4 20.4 2.7 23.4 25.6 28.5 29.3 32. 35.2 39.3 44.8 296 489 562 74 826 936 0 297 405 670 947 2462 3234 2.7 7.4 8.4 20.4 2.7 23.4 25.6 28.5 29.3 32. 35.2 39.3 44.8 302 500 580 765 856 97 48 356 476 765 2065 2603 3447 3 8.6 3.6 4.5 5.9 7.4 9.0 2.4 24.4 25.3 28.2 3 35.6 4 3.3 8.7 20.3 2.7 23.4 25.0 27.6 3 3.7 34.6 38.9 43. 48.7 329 556 737 834 955 066 272 492 64 95 2535 296 3850 3.3 8.7 20.3 2.7 23.4 25.0 27.6 3 3.7 34.6 38.9 43. 48.7 336 569 756 86 988 06 324 558 720 2057 2666 38 4087 Table 4

IN-PIOSP CU / PVC / IS / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) PVC Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOSP CU / XLPE / IS / OS / PVC / SWA / PVC ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, PVC Bedded, Galvanised Steel Wire Armoured, PVC Sheathed Cable, 300 / 500V, BS EN50288-7 IN-XIOSP IN-PIOSP No. of Pairs Thickness of Insulation Under Armour Armour Wire Cable Overall Approx. Cable Overall Approx. 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 9.8 5.8 6.9 8.5 20.4 22.3 25.2 28.8 29.9 33.8 37.9 42.2 49. 4.7 2 22.9 24.5 26.6 28.5 3 35.2 37.2 4.3 45.6 5 58.2 394 779 908 042 203 352 623 909 232 285 3545 4225 5598 4.7 2 22.9 24.5 26.6 28.5 3 35.2 37.2 4.3 45.6 5 58.2 403 797 935 078 249 407 697 200 243 2998 3545 4445 5928 Table 5 IN-XIOSP IN-PIOSP No. of Triads Thickness of Insulation 0.5 2.2 23.0 3.3 38.6 282 904 593 2370 2.2 23.0 3.3 38.6 290 949 7 2549 SINGLE & MULTI-TRIADS 5 2.7 24.3 33.5 4.7 3. 25.4 35.2 43.9 3.9 27.4 39.0 47.8 302 005 829 2776 325 02 2034 3088 367 293 2667 3698 2.7 24.3 33.5 4.7 3. 25.4 35.2 43.9 3.9 27.4 39.0 47.8 30 053 959 297 334 55 274 3298 377 35 2823 3932 7 / 7 7 / 7 7 / 7 7 / 7 5.3 3.4 45.7 56.9 443 655 3578 5383 5.3 3.4 45.7 56.9 457 737 3797 57 Table 6

FRT-XOL CU / XLPE / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 2 3 4 5 5 3 4 2 Component. Plain Annealed Copper Wire 2. Cross-linked Polyethylene 3. Aluminium / Polyester Tape 4. Tinned Copper Drain Wire 5. Low Smoke Zero Halogen (LSZH) CONSTRUCTION : Insulation: Insulation Colour: Cores Twisted: Lay Up: Wrap Film: Overall Screen: Outer Sheath: Outer Sheath Colour: Plain Annealed Copper, Class 2 Stranded Circular Cross-linked Polyethylene (XLPE) Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) Low Smoke Zero Halogen (LSZH) Black ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: -5ºC to 90ºC Final Short Circuit Temperature: 250ºC Test Voltage: REFERENCE STANDARDS Design Specification: : Flame Retardancy: Low Smoke Zero Halogen: INSTALLATION REFERENCE Min. Bending Radius : Max. Pulling Tension (N/mm 2 ): 50 2kV for minute BS EN50288-7 IEC60228, BS EN60228 IEC60332-3-22, BS EN60332-3-22 IEC6034-2, BS EN6034-2 IEC60754-, IEC60754-2 BS EN50267-2-, BS EN50267-2-2 8 x cable overall diameter Thickness (Quad) 3 0.5 7.0 7.9 0.4.2 2.3 3.4 4.7 6.5 8.8 9.5 2 24.2 27. 3.2 57 82 94 2 45 69 202 249 308 348 434 535 640 90 Table 7 ii

FRT-XOL CU / XLPE / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 Thickness (Quad) 3 5 7.4 8.4.4 2. 3.2 4.6 5.9 7.8 20.3 2 23.5 26.4 29.5 34.0 65 96 5 43 73 2 243 302 375 427 549 677 809 44 (Quad) 3 (Quad) 3 7.8 8.9 2.7 3.9 5.4 6.8 9. 2 22.6 25.0 28. 3.4 36.2 8.4 9.6 3. 3.9 5.4 6.9 8.6 2 23.9 24.8 27.7 3.2 34.8 40.4 73 0 30 64 200 245 283 365 440 56 65 803 960 368 87 35 59 204 260 30 370 466 578 666 86 064 27 843 (Quad) 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 9.6.3 5.5 6.5 8.3 20.0 22. 25. 28.8 29.8 33.3 37.5 4.8 48.5 6 93 224 292 375 448 535 693 860 993 286 590 898 2756 * O h i i d d d fi i il bl

FRT-XOL CU / XLPE / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 No. of Triads Thickness 0.5 7.3 6.7 24.8 3. 68 275 629 927 SINGLE & MULTI-TRIADS 5 7.8 7.9 27.0 33.9 8.2 9.2 28.7 36. 8.8 2. 3.8 39.9 79 334 795 73 90 403 946 398 0 56 254 854 7 / 7 7 / 7 7 / 7 7 / 7 0.4 25.2 38. 48. 56 767 873 2794 Table 9

FRT-XIOL CU / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 2 3 4 5 6 7 5 6 4 2 3 Component. Plain Annealed Copper Wire 2. Cross-linked Polyethylene 3. Tinned Copper Drain Wire 4. Aluminium / Polyester Tape (IS) 5. Aluminium / Polyester Tape (OS) 6. Tinned Copper Drain Wire 7. Low Smoke Zero Halogen (LSZH) 7 CONSTRUCTION : Insulation: Insulation Colour: Cores Twisted: Wrap Film: Individual Screen: Lay Up: Wrap Film: Overall Screen: Plain Annealed Copper, Class 2 Stranded Circular Cross-linked Polyethylene (XLPE) Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (IS) Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: -5ºC to 90ºC Final Short Circuit Temperature: 250ºC Test Voltage: REFERENCE STANDARDS Design Specification: : Flame Retardancy: Low Smoke Zero Halogen: INSTALLATION REFERENCE Min. Bending Radius : Max. Pulling Tension (N/mm 2 ): 50 2kV for minute BS EN50288-7 IEC60228, BS EN60228 IEC60332-3-22, BS EN60332-3-22 IEC6034-2, BS EN6034-2 IEC60754-, IEC60754-2 BS EN50267-2-, BS EN50267-2-2 8 x cable overall diameter Outer Sheath: Outer Sheath Colour: Low Smoke Zero Halogen (LSZH) Black Thickness 3 0.5 7..3.9 3.0 4.4 5.6 7.7 20.2 2 23. 26.0 29.0 33.5 60 23 53 86 227 262 336 46 474 596 735 878 263 Table 20 ii

FRT-XIOL CU / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 5 00V, BS EN50288-7 Thickness 3 5 7.5 2.7 4. 5.4 7.0 9.0 2.7 22.4 25. 28.2 3.4 36.4 67 39 76 223 264 35 394 487 558 79 886 058 525 3 3 7.9 2.6 3.6 4.9 6.2 7.9 20.3 23.0 24.0 26.6 29.9 33.5 38.6 8.5 3.9 4.8 6.2 7.9 9.5 22. 25.3 26.4 29.3 33. 36.9 42.7 75 55 206 252 299 357 460 557 652 827 020 236 762 90 92 248 307 377 438 567 702 223 048 3 564 2262 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 9.7 6.3 7.4 9.0 2. 23.2 26.3 30. 3.2 34.9 39.4 43.9 50.8 9 26 342 427 524 623 806 999 54 496 867 2226 3225 Table 2

FRT-XIOL CU / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 No. of Triads Thickness 0.5 7.4 7.5 26.0 32.6 70 338 778 46 SINGLE & MULTI-TRIADS 5 7.9 8.8 28.2 35.3 8.3 9.9 29.9 37.7 8.9 2.9 33.2 4 82 400 95 400 92 46 07 652 2 589 44 224 7 / 7 7 / 7 7 / 7 7 / 7 0.5 26. 39.5 49.7 59 849 2082 3095 Table 22

FRT-XOSL CU / XLPE / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 2 3 4 5 6 7 5 4 3 6 2 Component. Plain Annealed Copper Wire 2. Cross-linked Polyethylene 3. Aluminium / Polyester Tape 4. Low Smoke Zero Halogen (LSZH) 5. Galvanised Steel Wire Armoured 6. Tinned Copper Drain Wire 7. Low Smoke Zero Halogen (LSZH) 7 CONSTRUCTION : Insulation: Insulation Colour: Cores Twisted: Lay Up: Wrap Film: Overall Screen: Bedding: Plain Annealed Copper, Class 2 Stranded Circular Cross-linked Polyethylene (XLPE) Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) Low Smoke Zero Halogen (LSZH) Outer Sheath: Outer Sheath Colour: Low Smoke Zero Halogen (LSZH) Black ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: -5ºC to 90ºC Final Short Circuit Temperature: 250ºC Test Voltage: REFERENCE STANDARDS Design Specification: : Flame Retardancy: Low Smoke Zero Halogen: 2kV for minute BS EN50288-7 IEC60228, BS EN60228 IEC60332-3-22, BS EN60332-3-22 IEC6034-2, BS EN6034-2 IEC60754-, IEC60754-2 BS EN50267-2-, BS EN50267-2-2 Bedding Colour: Armour: Black Galvanized Steel Wire Armoured (SWA) INSTALLATION REFERENCE Min. Bending Radius : 0 x cable overall diameter Max. Pulling Tension (N/mm 2 ): 70 Thickness Under Armour Armour Wire (Quad) 3 0.5 7.2 8. 0.8.4 3.6 4.8 6.6 8.8 9.4 2 24. 26.8 30.8.9 2.7 5.7 6.3 7.4 8.5 2 22.4 24.6 25.4 27.6 30.3 33.0 37.2 268 32 403 440 494 547 72 823 949 08 84 369 552 955 Table 23 ii

FRT-XOSL CU / XLPE / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 Thickness Under Armour Armour Wire (Quad) 3 5 7.6 8.6 2.2 3.4 4.6 5.9 7.9 20.3 2 23.3 26. 29.0 33.4 2.3 3.2 6.4 7. 8.3 20.4 2.7 23.7 26.3 27.0 29.3 32.3 35.4 4 284 340 439 483 544 79 79 96 080 49 339 562 790 257 (Quad) 3 (Quad) 3 8.0 9. 2.2 2.9 4. 5.5 6.9 9.0 2 22.3 24.8 27.8 3 35.6 8.6 9.8 3.2 4. 5.4 6.9 8.5 20.8 23.7 24.5 27.3 3 34. 39.8 2.7 3.9 7. 7.8 9.9 2.3 22.7 25.0 27.6 28.3 3 34.0 37.3 42.9 3.3 4.6 8. 9.9 2.2 22.7 24.5 26.8 29.9 3 33.5 37.0 4.4 47.3 300 370 470 525 70 779 868 020 85 276 508 74 2006 2822 334 46 526 704 793 894 009 84 392 507 783 2095 2656 3498 (Quad) 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 9.8.3 5.4 6.5 8. 9.9 2.8 24.6 28. 29. 3 36.9 4.2 47.5 4.7 6. 2.2 22.3 24. 25.9 27.8 30.8 34.5 35.5 39.8 44.4 48.9 56.2 399 504 754 862 999 38 267 59 804 976 2605 330 36 5095

FRT-XOSL CU / XLPE / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 No. of Triads Thickness Under Armour Armour Wire 0.5 7.5 6.5 24.2 30. 2.2 22.3 30.4 36.5 284 840 446 924 SINGLE & MULTI-TRIADS 5 8.0 7.7 26.2 32.7 8.4 8.8 27.9 34.9 9.0 2 30.8 38.9 2.7 23.5 32.4 39.8 3. 24.8 34. 42.2 3.9 26.7 37.2 46.4 304 938 663 2469 328 048 875 2795 370 225 2275 3453 7 / 7 7 / 7 7 / 7 7 / 7 0.4 24.4 37. 46.5 5.3 3 44.6 55.2 448 583 3392 5056 Table 25

FRT-XIOSL CU / XLPE / IS / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 9 7 6 5 8 4 2 3 Component. Plain Annealed Copper Wire 2. Cross-linked Polyethylene 3. Tinned Copper Drain Wire 4. Aluminium / Polyester Tape (IS) 5. Aluminium / Polyester (OS) 6. Low Smoke Zero Halogen (LSZH) 7. Galvanised Steel Wire Armoured 8. Tinned Copper Drain Wire 9. Low Smoke Zero Halogen (LSZH) 2 3 4 5 6 7 8 9 CONSTRUCTION : Insulation: Plain Annealed Copper, Class 2 Stranded Circular Cross-linked Polyethylene (XLPE) Armour: Outer Sheath: Outer Sheath Colour: Galvanized Steel Wire Armoured (SWA) Low Smoke Zero Halogen (LSZH) Black Insulation Colour: Cores Twisted: Wrap Film: Individual Screen: Lay Up: Wrap Film: Overall Screen: Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (IS) Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: -5ºC to 90ºC Final Short Circuit Temperature: 250ºC Test Voltage: REFERENCE STANDARDS Design Specification: : Flame Retardancy: Low Smoke Zero Halogen: 2kV for minute BS EN50288-7 IEC60228, BS EN60228 IEC60332-3-22, BS EN60332-3-22 IEC6034-2, BS EN6034-2 IEC60754-, IEC60754-2 BS EN50267-2-, BS EN50267-2-2 Bedding: Low Smoke Zero Halogen (LSZH) INSTALLATION REFERENCE Min. Bending Radius : 0 x cable overall diameter Bedding Colour: Black Max. Pulling Tension (N/mm 2 ): 70 Thickness Under Armour Armour Wire 3 0.5 7.2.2.8 2.9 4. 5.3 7.2 9.5 20.2 22.4 25. 27.9 3.9 6. 6.7 7.8 9.9 2. 23.2 25.5 26.2 28.6 3.3 34.3 39.3 268 433 478 539 7 783 923 066 39 349 562 794 2507 Table 26 ii

FRT-XIOSL CU / XLPE / IS / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 Thickness Under Armour Armour Wire 3 5 7.6.9 2.6 3.8 5. 6.5 8.5 2 2.7 24.2 27. 30. 35. 2.3 6.8 7.5 8.9 2 22.3 24.5 27.0 27.9 30.4 33.5 36.5 42.6 284 465 57 600 774 865 08 77 286 5 778 202 2924 3 3 0.6 8.0 3.3 4.6 5.9 7.4 9.6 22.3 23. 25.7 28.8 3 37.3 8.6 3.6 4.5 5.9 7.4 9.0 2.4 24.4 25.3 28.2 3 35.6 4 2.7 7.4 8.2 20.4 2.7 23.4 25.6 28.5 29.3 3.9 35.2 39.3 44.8 3.3 8.7 20.3 2.7 23.4 25.0 27.6 3 3 34.6 38.9 43. 48.7 300 495 559 749 834 945 309 47 667 962 2480 3256 334 563 744 843 965 076 283 505 638 976 2553 2982 3875 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 9.8 5.8 6.9 8.5 20.4 22.3 25.2 28.8 29.9 33.8 37.9 42.2 49. 4.7 2 22.9 24.5 26.4 28.5 3 35.2 36.5 4.3 45.6 5 58.2 399 787 97 05 200 364 637 925 236 287 3384 4252 5632 Table 27

FRT-XIOSL CU / XLPE / IS / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 No. of Triads Thickness Under Armour Armour Wire 0.5 7.5 7.0 25. 3.8 2.2 22.8 3.3 37.9 286 900 605 265 SINGLE & MULTI-TRIADS 5 8.0 8.3 27. 34.2 8.4 9.4 22.8 36.4 9.0 2.2 3.7 40. 2.7 24.3 33.5 4.7 3. 25.4 35.2 43.9 3.9 27.4 39.0 47.8 306 04 843 2795 330 2 2094 308 372 304 2684 372 7 / 7 7 / 7 7 / 7 7 / 7 0.4 25.0 38.0 48.0 5.3 3.4 45.7 56.9 449 668 360 544 Table 28

FR-XOL CU / MGT / XLPE / OS / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 2 3 4 5 6 6 4 5 3 2 Component. Plain Annealed Copper Wire 2. Mica Tape 3. Cross-linked Polyethylene 4. Aluminium / Polyester Tape 5. Tinned Copper Drain Wire 6. Low Smoke Zero Halogen (LSZH) CONSTRUCTION : Fire Barrier: Insulation: Plain Annealed Copper, Class 2 Stranded Circular Mica Tape (MGT) Cross-linked Polyethylene (XLPE) ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: -5ºC to 90ºC Final Short Circuit Temperature: 250ºC Test Voltage: 2kV for minute Insulation Colour: Cores Twisted: Lay Up: Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core REFERENCE STANDARDS Design Specification: : Fire Resistance: Flame Retardancy: BS EN50288-7 IEC60228, BS EN60228 BS6387 (C, W, Z), SS299 (C, W, Z), IEC6033 IEC60332-3-22, BS EN60332-3-22 Wrap Film: Overall Screen: Outer Sheath: Outer Sheath Colour: Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) Low Smoke Zero Halogen (LSZH) Orange or Blue Low Smoke Zero Halogen: INSTALLATION REFERENCE Min. Bending Radius : Max. Pulling Tension (N/mm 2 ): 50 IEC6034-2, BS EN6034-2 IEC60754-, IEC60754-2 BS EN50267-2-, BS EN50267-2-2 8 x cable overall diameter Thickness (Quad) 3 5 9.6 5.3 6.3 8. 9.9 2.8 24.8 28.4 29.4 32.9 36.8 4.2 47.8 89 42 65 206 26 308 356 458 567 645 828 000 96 720 Table 29 ii

FR-XOL CU / MGT / XLPE / OS / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 Thickness (Quad) 3 0.0 6.0 7.0 8.9 20.8 22.7 25.9 29.7 2 34.4 38.8 43.3 50. 98 58 82 230 292 346 400 56 640 73 94 6 386 970 (Quad) 3 2.4 7.0 8.4 20.2 22.4 24.5 27.9 3 33. 37. 4.8 46.7 54.2 3 95 23 283 349 428 496 64 794 9 76 450 73 2500 (Quad) 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 3.9 9.4 2 23. 25.6 28.0 3.9 36.6 38. 42.7 48. 53.7 62.3 50 253 284 383 475 583 679 873 090 277 650 2036 2428 353 Table 30

FR-XOL CU / MGT / XLPE / OS / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 No. of Triads Thickness 5 0. 24.6 37.2 46.8 09 488 52 695 SINGLE & MULTI-TRIADS 7 / 7 7 / 7 7 / 7 7 / 7 0.5 25.7 38.9 49.0.2 27.7 4 52.9 2.7 3.7 48.3 6 2 552 38 943 43 689 656 2443 93 95 2336 3478 Table 3

FR-XIOL CU / MGT / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 8 6 7 5 3 2 4 Component. Plain Annealed Copper Wire 2. Mica Tape 3. Cross-linked Polyethylene 4. Tinned Copper Drain Wire 5. Aluminium / Polyester Tape (IS) 6. Aluminium / Polyester Tape (OS) 7. Tinned Copper Drain Wire 8. Low Smoke Zero Halogen (LSZH) 2 3 4 5 6 7 8 CONSTRUCTION : Fire Barrier: Insulation: Plain Annealed Copper, Class 2 Stranded Circular Mica Tape (MGT) Cross-linked Polyethylene (XLPE) ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: -5ºC to 90ºC Final Short Circuit Temperature: 250ºC Test Voltage: 2kV for minute Insulation Colour: Cores Twisted: Wrap Film: Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad Polyester Binder Tape REFERENCE STANDARDS Design Specification: : Fire Resistance: BS EN50288-7 IEC60228, BS EN60228 BS6387 (C, W, Z), SS299 (C, W, Z), IEC6033 Individual Screen: Lay Up: Wrap Film: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (IS) Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Polyester Binder Tape Flame Retardancy: Low Smoke Zero Halogen: INSTALLATION REFERENCE Min. Bending Radius : IEC60332-3-22, BS EN60332-3-22 IEC6034-2, BS EN6034-2 IEC60754-, IEC60754-2 BS EN50267-2-, BS EN50267-2-2 8 x cable overall diameter Overall Screen: Outer Sheath: Outer Sheath Colour: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) Low Smoke Zero Halogen (LSZH) Orange or Blue Max. Pulling Tension (N/mm 2 ): 50 Thickness 3 5 9.6 5.7 6.9 8.6 20.4 2 25.6 29.3 30.3 34.0 38.2 42.7 49.3 88 83 24 295 350 47 536 663 757 974 200 43 2032 Table 32 ii

FR-XIOL CU / MGT / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 Thickness 3 0.0 6.5 7.6 9.4 2.4 23.5 26.7 3 3.7 35.5 39.9 44.6 5.7 96 208 265 326 399 463 597 739 847 09 345 606 235 3 7.6 8.8 2 22.9 25.3 28.7 32.9 34. 38.2 43.0 48.0 55.7 2 240 30 396 472 562 725 898 032 332 643 960 2833 3 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 7 / 7 20.0 2.3 23.7 26. 28.8 32.7 37.5 39. 43.8 49.2 55.2 64.0 49 35 4 525 630 750 970 20 407 89 2242 2703 3903 Table 33

FR-XIOL CU / MGT / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 No. of Triads Thickness 5 0. 25.3 38.3 48.2 09 56 329 956 SINGLE & MULTI-TRIADS 0.5 26.4 40.0 50.4.2 28.5 43. 54.4 2 627 500 22 43 768 846 2750 7 / 7 7 / 7 7 / 7 7 / 7 2.7 32.4 49.4 62.6 93 037 2544 385 Table 34

FR-XOSL CU / MGT / XLPE / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) Mica Taped, XLPE Insulated, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7 8 6 5 4 7 3 2 Component. Plain Annealed Copper Wire 2. Mica Tape 3. Cross-linked Polyethylene 4. Aluminium / Polyester Tape 5. Low Smoke Zero Halogen (LSZH) 6. Galvanised Steel Wire Armoured 7. Tinned Copper Drain Wire 8. Low Smoke Zero Halogen (LSZH) 2 3 4 5 6 7 8 CONSTRUCTION : Fire Barrier: Plain Annealed Copper, Class 2 Stranded Circular Mica Tape (MGT) Outer Sheath: Outer Sheath Colour: Low Smoke Zero Halogen (LSZH) Orange or Blue Insulation: Insulation Colour: Cores Twisted: Cross-linked Polyethylene (XLPE) Pair/s - Black/White with Black Triad/s - Red/Black/White with Black Cores twisted to form a pair, traid or quad ELECTRICAL CHARACTERISTICS Operating Voltage, Uo/U: 300/500V Operating Temperature: -5ºC to 90ºC Final Short Circuit Temperature: 250ºC Test Voltage: 2kV for minute Lay Up: Wrap Film: Overall Screen: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core Polyester Binder Tape Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm 2 (7/0.3mm) (OS) REFERENCE STANDARDS Design Specification: : Fire Resistance: Flame Retardancy: BS EN50288-7 IEC60228, BS EN60228 BS6387 (C, W, Z), SS299 (C, W, Z), IEC6033 IEC60332-3-22, BS EN60332-3-22 Bedding: Bedding Colour: Low Smoke Zero Halogen (LSZH) Black Low Smoke Zero Halogen: IEC6034-2, BS EN6034-2 IEC60754-, IEC60754-2 BS EN50267-2-, BS EN50267-2-2 Armour: Galvanized Steel Wire Armoured (SWA) INSTALLATION REFERENCE Min. Bending Radius : 0 x cable overall diameter Max. Pulling Tension (N/mm 2 ): 70 Thickness Under Armour Armour Wire (Quad) 3 5 9.7. 5.2 6.2 7.8 9.6 2 24.3 27.7 28.7 3 35.9 40. 46.7 4.4 5.8 20.8 2 23.6 25.4 27.5 30.3 33.9 34.9 38.2 43.0 47.4 55.0 356 442 682 762 858 967 09 270 484 499 866 243 2787 3970 Table 35 ii