AIR EMISSION PERMIT NO IS ISSUED TO. Waldorf Corporation

Similar documents
AIR EMISSION PERMIT NO IS ISSUED TO. ConAgra Flour Milling Company P.O. Box 3500 Omaha, NE For

AIR EMISSION PERMIT NO IS ISSUED TO. ConAgra Flour Milling Company P.O. Box 3500 Omaha, NE For

AIR EMISSION PERMIT NO Administrative Amendment IS ISSUED TO. ConAgra Food Ingredients Co

DRAFT AIR EMISSION PERMIT NO Major Amendment IS ISSUED TO. Miller Milling Co LLC

AIR EMISSION PERMIT NO IS ISSUED TO. Van Hoven Company, Inc.

AIR EMISSION PERMIT NO IS ISSUED TO. Brown Printing Company - Division of Gruner & Jahr

DRAFT. AIR EMISSION PERMIT NO Major Amendment IS ISSUED TO. Pan O Gold Baking Co

AIR EMISSION PERMIT NO IS ISSUED TO. Hood Packaging Corporation

Permit No AIR EMISSION PERMIT NO IS ISSUED TO. Lafarge Corporation - US Cement Group

AIR EMISSION PERMIT NO IS ISSUED TO

AIR EMISSION PERMIT NO IS ISSUED TO. American Color Graphics, Inc.

Air Individual Permit Part 70 Reissuance Gateway Blvd Arden Hills, Minnesota Ramsey County

AIR EMISSION PERMIT NO IS ISSUED TO. ST. PAUL BRASS AND ALUMINUM FOUNDRY 954 West Minnehaha Avenue St Paul, Ramsey County, MN 55104

AIR EMISSION PERMIT NO IS ISSUED TO. Plymouth Foam Products 1800 Sunset Drive Plymouth, Wisconsin FOR

AIR EMISSION PERMIT NO IS ISSUED TO

DRAFT. AIR EMISSION PERMIT NO Major Amendment IS ISSUED TO

AIR EMISSION PERMIT NO IS ISSUED TO. BLANDIN PAPER COMPANY & Minnesota Power

AIR EMISSION PERMIT NO IS ISSUED TO. Water Gremlin Co. WATER GREMLIN CO 1610 Whitaker Avenue White Bear Lake, Ramsey County, MN 55110

AIR EMISSION PERMIT NO IS ISSUED TO. Lafarge Corporation - US Cement Group

AIR EMISSION PERMIT NO IS ISSUED TO. LSP - Cottage Grove LP

AIR EMISSION PERMIT NO IS ISSUED TO. Busch Agricultural Resources, Inc.

DRAFT. AIR EMISSION PERMIT NO Total Facility Operating Permit IS ISSUED TO. AmeriPride Services Inc

AIR EMISSION PERMIT NO IS ISSUED TO

AIR EMISSION PERMIT NO IS ISSUED TO. Order of St. Benedict/St. John's Abbey

Draft Air Individual Permit Part 70 Permit

DRAFT/PROPOSED AIR EMISSION PERMIT NO IS ISSUED TO. Potlatch Land & Lumber LLC, Bemidji

DRAFT/PROPOSED. AIR EMISSION PERMIT NO Total Facility Oper. Permit - Reissuance IS ISSUED TO. Wausau Paper Mills LLC

AIR EMISSION PERMIT NO Major Amendment IS ISSUED TO. American Crystal Sugar Company

AIR EMISSION PERMIT NO Administrative Amendment IS ISSUED TO. Magellan Midstream Partners, LP

AIR EMISSION PERMIT NO IS ISSUED TO. COLD SPRING GRANITE COMPANY 202 South 3rd Avenue Cold Spring, Stearns County, MN 56320

Draft Air Individual Permit Major Amendment

AIR EMISSION PERMIT NO IS ISSUED TO. Poly Foam, Inc. 116 Pine Street South Lester Prairie, McLeod County, Minnesota 55354

AIR EMISSION PERMIT NO IS ISSUED TO ISPAT INLAND STEEL MINING CO

AIR EMISSION PERMIT NO Minor Amendment IS ISSUED TO. Order of St Benedict/St John's Abbey

AIR EMISSION PERMIT NO IS ISSUED TO. CUMMINS POWER GENERATION, INC rd Avenue Northeast Fridley, Anoka County, MN 55432

Minnesota Pollution Control Agency

AIR EMISSION PERMIT NO IS ISSUED TO. Granite Falls Community Ethanol Plant LLC

Air Individual Permit Part 70 Reissuance Pine St S Lester Prairie, MN McLeod County

AIR EMISSION PERMIT NO ADMINISTRATIVE AMENDMENT IS ISSUED TO. Northern States Power Company

AIR EMISSION PERMIT NO IS ISSUED TO GERDAU AMERISTEEL US INC

AIR EMISSION PERMIT NO Total Facility Operating Permit - Reissuance IS ISSUED TO. The City of Chaska AND

AIR EMISSION PERMIT NO IS ISSUED TO. Mittal Steel USA Inc

AIR EMISSION PERMIT NO IS ISSUED TO. HARD CHROME INC Second Street Northeast Minneapolis, Hennepin County, MN 55418

Draft Permit Air Individual Permit Part 70 Reissuance

AIR EMISSION PERMIT NO IS ISSUED TO. Arctic Cat, Inc.

AIR EMISSION PERMIT NO IS ISSUED TO. Order of St. Benedict/St. John's Abbey

AIR EMISSION PERMIT NO IS ISSUED TO. GAF Building Materials Manufacturing Corporation

Draft Air Individual Permit Part 70 Reissuance County Road 25 Saint Louis Park, MN55416 Hennepin County

DRAFT. AIR EMISSION PERMIT NO Total Facility Operating Permit IS ISSUED TO. NuStar Pipeline Operating Partnership LP

AIR EMISSION PERMIT NO IS ISSUED TO. Tennant Co

A.6 Boilers. A.6.1 New and Existing Boilers located within AQCR 131

AIR EMISSION PERMIT NO IS ISSUED TO. Malt-O-Meal Company

Air Individual Permit Part 70 Reissuance Ever-Green Energy, Inc. Environmental Wood Supply, LLC

DRAFT Air Individual Permit Part 70 Permit

AIR EMISSION PERMIT NO Minor Amendment IS ISSUED TO. Unimin Corp

Draft Air Individual Permit Part 70 Reissuance S Robert Trail Inver Grove Heights, MN Dakota County

Draft Air Individual Permit State Permit

AIR EMISSION PERMIT NO IS ISSUED TO. Grede Foundries Inc. Grede - St Cloud Inc 5200 Foundry Cir St. Cloud, Stearns County, MN 56303

DRAFT. AIR EMISSION PERMIT NO Total Facility Operating Permit IS ISSUED TO. Magnetation LLC

AIR EMISSION PERMIT NO IS ISSUED TO. Potlatch Corporation. Potlatch Corporation - Cloquet PO Box 503 Cloquet, Carlton County, MN 55720

AIR EMISSION PERMIT NO IS ISSUED TO

AIR EMISSION PERMIT NO Total Facility Operating Permit - Reissuance IS ISSUED TO. Co-Operative Plating Company

AIR EMISSION PERMIT NO Major Amendment IS ISSUED TO. Boise White Paper LLC

AIR EMISSION PERMIT NO IS ISSUED TO Minnesota Power & Light

AIR EMISSION PERMIT NO IS ISSUED TO. Boise Cascade Corporation

AIR EMISSION PERMIT NO (Part 70 Reissuance) IS ISSUED TO

AIR EMISSION PERMIT NO ADMINISTRATIVE AMENDMENT IS ISSUED TO. Northern States Power Company

AIR EMISSION PERMIT NO Major Amendment IS ISSUED TO. Northern States Power Company dba Xcel Energy

State of New Hampshire Department of Environmental Services Air Resources Division. Temporary Permit

AIR EMISSION PERMIT NO IS ISSUED TO. ELKAY Manufacturing

AIR EMISSION PERMIT NO IS ISSUED TO. SUNRISE FIBERGLASS CORPORATION th St Wyoming, Chisago County, MN 55092

NSPS for Dc Boilers Burning Residual Oil

AIR EMISSION PERMIT NO IS ISSUED TO. Northern States Power Company

Pollution Control Agency

AIR EMISSION PERMIT NO IS ISSUED TO

AIR EMISSION PERMIT NO (Part 70 Reissuance) IS ISSUED TO. Gerdau Ameristeel US Inc

AIR EMISSION PERMIT NO IS ISSUED TO. Northern States Power Company

Permit Applications Table TABLE OF CONTENTS

University of Minnesota Board of Regents. 202 Morrill Hall Minneapolis, Hennepin County, Minnesota 55455

DRAFT. AIR EMISSION PERMIT NO Total Facility Operating Permit Reissuance IS ISSUED TO. Nico Products Inc.

AIR EMISSION PERMIT NO IS ISSUED TO. 3M Company

GENMAR INDUSTRIES, INC. 100 South 5th Street, Suite 2400 Minneapolis, Minnesota 55402

AIR EMISSION PERMIT NO IS ISSUED TO. PowerMinn 9090, LLC 2295 Corporate Boulevard, Suite 222 Boca Raton, FL

AIR EMISSION PERMIT NO IS ISSUED TO. 3MCo

TABLE OF CONTENTS Notice to the Permittee Permit Shield Facility Description Amendment Description Table A: Limits and Other Requirements

AIR EMISSION PERMIT NO [AMENDMENT TO AIR EMISSION PERMIT NO ] IS ISSUED TO

AIR EMISSION PERMIT NO IS ISSUED TO. Pope/Douglas Joint Solid Waste Management Board

AIR EMISSION PERMIT NO IS ISSUED TO. Minnesota Power & Light The Wisconsin Public Power Inc. System

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. January 26, NEW SOURCE REVIEW PERMIT TO INSTALL No.

AIR EMISSION PERMIT NO IS ISSUED TO. Kaneb Pipe Line Operating Partnership, L.P. a Valero L.P. company. for

RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF AIR POLLUTION CONTROL

AIR EMISSION PERMIT NO IS ISSUED TO. UNIMIN MINNESOTA CORP - KASOTA PLANT th Street Kasota, Le Sueur County, MN 56050

502(b)(10) Permit for Part 70 Source

STATE OF MINNESOTA MINNESOTA POLLUTION CONTROL AGENCY

AIR EMISSION PERMIT NO IS ISSUED TO. MinnErgy LLC

STATE OF MINNESOTA MINNESOTA POLLUTION CONTROL AGENCY

AIR EMISSION PERMIT NO IS ISSUED TO SUPERIOR PLATING INC.

AIR EMISSION PERMIT NO IS ISSUED TO AMERICAST TECHNOLOGIES, INC.

Transcription:

AIR EMISSION PERMIT NO. 12300410-001 IS ISSUED TO Waldorf Corporation Waldorf Corporation - A Rock-Tenn Company 2250 Wabash Avenue St. Paul, Ramsey County, MN 55114 The emission units, control equipment and emission stacks at the stationary source authorized in this permit are as described in the following permit application(s): Permit Type Application Date Total Facility Operating Permit April 1995 Minor Permit Amendment March 1996 Minor Permit Amendment July 1996 This permit authorizes the Permittee to the stationary source at the address listed above unless otherwise noted in Table A. The Permittee must comply with all the conditions of the permit. Any changes or modifications to the stationary source must be performed in compliance with Minn. R. 7007.1150 to 7007.1500. Terms used in the permit are as defined in the state air pollution control rules unless the term is explicitly defined in the permit. Permit Type: Federal; Pt 70/Incorporates Existing NSR Conditions Issue Date: April 17, 2003 Expiration: April 17, 2008 All Title I Conditions do not expire. Ann M. Foss Major Facilities Section Manager Majors and Remediation Division for Sheryl A. Corrigan Commissioner Minnesota Pollution Control Agency TDD (for hearing and speech impaired only): (651) 282-5332 Printed on recycled paper containing at least 10% fibers from paper recycled by consumers

Permit No. 12300410-001 TABLE OF CONTENTS Notice to the Permittee Permit Shield Facility Description Table A: Limits and Other Requirements Table B: Submittals Table C: Compliance Schedule Appendices: Attached and Referenced in Table A

Permit No. 12300410-001 NOTICE TO THE PERMITTEE: Your stationary source may be subject to the requirements of the Minnesota Pollution Control Agency s (MPCA) solid waste, hazardous waste, and water quality programs. If you wish to obtain information on these programs, including information on obtaining any required permits, please contact the MPCA general information number at: Metro Area (651) 296-6300 Outside Metro Area 1-800-657-3864 TTY (651) 282-5332 The rules governing these programs are contained in Minn. R. chs. 7000-7105. Written questions may be sent to: Minnesota Pollution Control Agency, 520 Lafayette Road North, St. Paul, Minnesota 55155-4194. Questions about this air emission permit or about air quality requirements can also be directed to the telephone numbers and address listed above. PERMIT SHIELD: Subject to the limitations in Minn. R. 7007.1800, compliance with the conditions of this permit shall be deemed compliance with the specific provision of the applicable requirement identified in the permit as the basis of each condition. Subject to the limitations of Minn. R. 7007.1800 and 7017.0100, subp. 2, notwithstanding the conditions of this permit specifying compliance practices for applicable requirements, any person (including the Permittee) may also use other credible evidence to establish compliance or noncompliance with applicable requirements.

Permit No. 12300410-001 FACILITY DESCRIPTION: Waldorf manufactures 100 percent recycled corrugated medium and boxboard at the St. Paul facility. The paper products are manufactured entirely from pre- and post-consumer corrugated board, white paper, newsprint, and boxboard. Some of the boxboard produced is printed using rotogravure or web offset printing. The printed boxboard may also be converted into folding cartons. The printing processes are sources of Volatile Organic Compounds (VOC) and Hazardous Air Pollutant (HAP) emissions. The papermaking processes are not a significant source of emissions, except for VOC emissions. The VOC emissions from the papermaking are primarily from material used for cleaning the papermaking machines, as well as from additives added to the paper. Process steam is purchased and piped from the Xcel High Bridge facility in St. Paul. Some of the purchased steam is used by Waldorf to cogenerate electricity. A steam plant, consisting of four boilers, is operational at Waldorf. The boilers are maintained in a stand-by mode to provide steam in the event that the supply from Xcel is interrupted or discontinued. The boilers are allowed to burn natural gas, #2 or #6 fuel oil. The boilers are sources of particulate matter, nitrogen oxides, sulfur dioxide, carbon monoxide, VOC, and HAP emissions. The actual emissions from the boilers have been very low, as most of the steam utilized by the facility has been purchased rather than produced on-site.

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 Table A contains limits and other requirements with which your facility must comply. The limits are located in the first column of the table (What To do). The limits can be emission limits or operational limits. This column also contains the actions that you must take and the records you must keep to show that you are complying with the limits. The second column of Table A (Why to do it) lists the regulatory basis for these limits. Appendices included as conditions of your permit are listed in Table A under total facility requirements. Subject Item: Total Facility What to do OPERATIONAL REQUIREMENTS hdr Why to do it Circumvention: Do not install or use a device or means that conceals or dilutes emissions, which would otherwise violate a federal or state air pollution control rule, without reducing the total amount of pollutant emitted. Air Pollution Control Equipment: Operate all pollution control equipment whenever the corresponding process equipment and emission units are operated, unless otherwise noted in Table A. Operation and Maintenance Plan: Retain at the stationary source an operation and maintenance plan for all air pollution control equipment. At a minimum, the O & M plan shall identify all air pollution control equipment and shall include a preventative maintenance program for that equipment, a description of (the minimum but not necessarily the only) corrective actions to be taken to restore the equipment to proper operation to meet applicable permit conditions, a description of the employee training program for proper operation and maintenance of the control equipment, and the records kept to demonstrate plan implementation. Operation Changes: In any shutdown, breakdown, or deviation the Permittee shall immediately take all practical steps to modify operations to reduce the emission of any regulated air pollutant. The Commissioner may require feasible and practical modifications in the operation to reduce emissions of air pollutants. No emissions units that have an unreasonable shutdown or breakdown frequency of process or control equipment shall be permitted to operate. Noise: The Permittee shall comply with the noise standards set forth in Minn. R. 7030.0010 to 7030.0080 at all times during the operation of any emission units. This is a state only requirement and is not enforceable by the EPA Administrator or citizens under the Clean Air Act. Inspections: The Permittee shall comply with the inspection procedures and requirements as found in Minn. R. 7007.0800, subp. 9(A). The Permittee shall comply with the General Conditions listed in Minn. R. 7007.0800, subp. 16. PERFORMANCE TESTING Performance Testing: Conduct all performance tests in accordance with Minn. R. ch. 7017 unless otherwise noted in Tables A, B, and/or C. Performance Test Notifications and Submittals: Performance Tests are due as outlined in Tables A and B of the permit. See Table B for additional testing requirements. Performance Test Notification (written): due 30 days before each Performance Test Performance Test Plan: due 30 days before each Performance Test Performance Test Pre-test Meeting: due 7 days before each Performance Test Performance Test Report: due 45 days after each Performance Test Performance Test Report - Microfiche Copy: due 105 days after each Performance Test Limits set as a result of a performance test (conducted before or after permit issuance) apply until superseded as specified by Minn. R. 7017.2025 following formal review of a subsequent performance test on the same unit. MONITORING REQUIREMENTS Monitoring Equipment Calibration: Annually calibrate all required monitoring equipment (any requirements applying to continuous emission monitors are listed separately in this permit). Operation of Monitoring Equipment: Unless otherwise noted in Tables A, B, and/or C, monitoring a process or control equipment connected to that process is not necessary during periods when the process is shutdown, or during checks of the monitoring systems, such as calibration checks and zero and span adjustments. If monitoring records are required, they should reflect any such periods of process shutdown or checks of the monitoring system. MODELING REQUIREMENTS Minn. R. 7011.0020 Minn. R. 7007.0800, subp. 2; Minn. R. 7007.0800, subp. 16(J) Minn. R. 7007.0800, subp. 14 and Minn. R. 7007.0800, subp. 16(J) Minn. R. 7019.1000, subp. 4 Minn. R. 7030.0010-7030.0080 Minn. R. 7007.0800, subp. 9(A) Minn. R. 7007.0800, subp. 16 hdr Minn. R. ch. 7017 Minn. R. 7017.2030, subp. 1-4 and Minn. R. 7017.2035, subp. 1-2 Minn. R. 7017.2025 hdr Minn. R. 7007.0800, subp. 4(D) Minn. R. 7007.0800, subp. 4(D) hdr A-1

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 Modeling Protocol. If the boilers are operated such that the following actual emissions are exceeded: 1000 tons per year of NOx, 250 tpy of SO2, or 100 tpy of PM, then the Permittee shal submit a modeling protocol. This protocol shall describe the proposed modeling methodology and input data, in accordance with MPCA modeling guidance for Title V air dispersion modeling analyses. The modeling protocol shall be submitted within one year of the calendar year in which the thresholds described above are exceeded. RECORDKEEPING Record keeping: Retain all records at the stationary source for a period of five (5) years from the date of monitoring, sample, measurement, or report. Records which must be retained at this location include all calibration and maintenance records, all original recordings for continuous monitoring instrumentation, and copies of all reports required by the permit. Records must conform to the requirements listed in Minn. R. 7007.0800, subp. 5(A). Recordkeeping: Maintain records describing any insignificant modifications (as required by Minn. R. 7007. 1250, subp. 3) or changes contravening permit terms (as required by Minn. R. 7007.1350 subp. 2), including records of the emissions resulting from those changes. REPORTING/SUBMITTALS Shutdown Notifications: Notify the Commissioner at least 24 hours in advance of a planned shutdown of any control equipment or process equipment if the shutdown would cause any increase in the emissions of any regulated air pollutant. If the owner or operator does not have advance knowledge of the shutdown, notification shall be made to the Commissioner as soon as possible after the shutdown. However, notification is not required in the circumstances outlined in Items A, B and C of Minn. R. 7019.1000, subp. 3. At the time of notification, the owner or operator shall inform the Commissioner of the cause of the shutdown and the estimated duration. The owner or operator shall notify the Commissioner when the shutdown is over. Breakdown Notifications: Notify the Commissioner within 24 hours of a breakdown of more than one hour duration of any control equipment or process equipment if the breakdown causes any increase in the emissions of any regulated air pollutant. The 24-hour time period starts when the breakdown was discovered or reasonably should have been discovered by the owner or operator. However, notification is not required in the circumstances outlined in Items A, B and C of Minn. R. 7019.1000, subp. 2. Minn. R. 7007.0800, subp. 2 hdr Minn. R. 7007.0800, subp. 5(C) Minn. R. 7007. 0800, subp. 5(B) hdr Minn. R. 7019.1000, subp. 3 Minn. R. 7019.1000, subp. 2 At the time of notification or as soon as possible thereafter, the owner or operator shall inform the Commissioner of the cause of the breakdown and the estimated duration. The owner or operator shall notify the Commissioner when the breakdown is over. Notification of Deviations Endangering Human Health or the Environment: As soon Minn. R. 7019.1000, subp. 1 as possible after discovery, notify the Commissioner or the state duty officer, either orally or by facsimile, of any deviation from permit conditions which could endanger human health or the environment. Notification of Deviations Endangering Human Health or the Environment Report: Minn. R. 7019.1000, subp. 1 Within 2 working days of discovery, notify the Commissioner in writing of any deviation from permit conditions which could endanger human health or the environment. Include the following information in this written description: 1. the cause of the deviation; 2. the exact dates of the period of the deviation, if the deviation has been corrected; 3. whether or not the deviation has been corrected; 4. the anticipated time by which the deviation is expected to be corrected, if not yet corrected; and 5. steps taken or planned to reduce, eliminate, and prevent reoccurrence of the deviation. Application for Permit Amendment: If a permit amendment is needed, submit an Minn. R. 7007.1150 through Minn. R. 7007.1500 application in accordance with the requirements of Minn. R. 7007.1150 through Minn. R. 7007.1500. Submittal dates vary, depending on the type of amendment needed. Extension Requests: The Permittee may apply for an Administrative Amendment Minn. R. 7007.1400, subp. 1(H) to extend a deadline in a permit by no more than 120 days, provided the proposed deadline extension meets the requirements of Minn. R. 7007.1400, subp. 1(H). Emission Inventory Report: due 91 days after end of each calendar year following Minn. R. 7019.3000 through Minn. R. 7019.3010 permit issuance (April 1). To be submitted on a form approved by the Commissioner. Emission Fees: due 60 days after receipt of an MPCA bill. Minn. R. 7002.0005 through Minn. R. 7002.0095 A-2

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 If applicable, the Permittee is required to submit a Risk Management Plan (RMP) under the federal rule, 40 CFR pt. 68. Each owner or operator of a stationary source, at which a regulated substance is present above a threshold quantity in a process, shall design and implement an accidental release prevention program. A complete RMP must be submitted to the RMP Reporting Center, PO Box 3346, Merrifield, VA 22116. RMP submittal information may be obtained at http://www.epa.gov/swercepp or by calling 1-800-424-9346. These requirements must be complied with no later than the latest of the following dates: (1) June 21, 1999; (2) Three years after the date on which a regulated substance is first listed under 40 CFR Section 68.130; or (3) The date on which a regulated substance is first present above a threshold quantity in a process. 40 CFR pt. 68 A-3

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 Subject Item: GP 001 Boilers Associated Items: EU 001 Boiler 1 EU 002 Boiler 2 EU 003 Boiler 3 EU 004 Boiler 4 What to do Why to do it Total Particulate Matter: less than or equal to 0.4 lbs/million Btu heat input. This Minn. R. 7011.0510, subp. 1 applies separately to each boiler. PTE for the boilers based on worst-case allowable fuels is 0.12 lb/mmbtu. Total Particulate Matter: less than or equal to 285 tons/year using 12-month Rolling Average. Limit is for total PM emissions from boilers, as calculated using formula below. PM = [NG * 0.0072 * HVNG]/2000 + (3.3 * FO2)/2000 + [(9.19*S +4.72) *FO6]/2000; where: NG = Total volume of natural gas burned in boilers based on 12-month rolling sum, in units of cf 0.0072 = emission factor for natural gas from AP-42, in units of lb/mmbtu HVNG = Average heating value of natural gas as provided by supplier, in units of mmbtu/cf 2000 = conversion factor, in units of lb/ton 3.3 = emission factor for #2 fuel oil from AP-42, in units of lb/1000 gallons FO2 = Total volume of #2 fuel oil burned in boilers based on 12-month rolling sum, in units of gallons (9.19*S +4.72) = emission factor for #6 fuel oil from AP-42, in units of lb/1000 gallons S = % sulfur in fuel oil, weight percent FO6 = Total volume of #6 fuel oil burned in boilers based on 12-month rolling sum, in units of gallons Sulfur Dioxide: less than or equal to 1.6 lbs/million Btu heat input. This applies Minn. R. 7011.0510, subp. 1 separately to each boiler. Opacity: less than or equal to 20 percent opacity except for one six-minute period Minn. R. 7011.0510, subp. 2 per hour of not more than 60 percent opacity. This applies separately to each boiler. Sulfur Content of Fuel: less than or equal to 0.5 percent by weight for #2 fuel oil. Minn. R. 7007.0800, subp. 2 Minn. R. 7009.0080 (State ambient air quality standards as demonstrated by modeling) Minn. R. 7009.0080 (State ambient air quality standards as demonstrated by modeling) Sulfur Content of Fuel: less than or equal to 1.5 percent by weight for #6 fuel oil. Minn. R. 7007.0800, subp. 2 Fuel Type: Natural gas, No. 2 fuel oil, or No. 6 fuel oil only, by design. MONITORING AND RECORDKEEPING REQUIREMENTS Emissions Monitoring: The owner or operator shall use a COMS to measure opacity emissions from the boilers. Monthly Recordkeeping - Total PM Emissions. By the 15th of the month, the Permittee shall calculate and record the following: 1) The total fuel usage of each fuel used in the boilers for the previous calendar month using the daily usage records. 2) The average heating value, for the preivous 12-month period, for each fuel type burned using the data provided by the fuel supplier. 3) The 12 month rolling sum Total PM Emisisons for the previous 12 month period using the formula specified in this permit. The Total PM emissions using the formula only needs to be calculated if fuel oil was combusted during the preivous month. PTE for the boiler using natural gas shows that the emission limit is met. Fuel Records: The Permittee shall obtain and maintain a certification from the fuel supplier for each fuel oil delivery specifying the sulfur content of the fuel oil, in percent by weight, and the heating value of the fuel oil, in mmbtu/gal. The Permittee shall also obtain and maintain a certification from the natural gas supplier specifying the heating value of the natural gas, in mmbtu/cf. This information shall be maintained on site. Daily Recordkeeping. On each day of operation, the Permittee shall calculate, record, and maintain records of the total quantity of all fuel used in the boilers. Fuel usage records: the Permittee shall, on a monthly basis, record what boilers were operated during the month and the type of fuel burned and, if fuel oil was burned, the quantity of fuel oil burned, during the month. The Permittee shall also record the volume and type of fuel oils delivered to the facility during the month. Minn. R. 7005.0100, subp. 35a hdr Minn. R. 7007.0800, subp. 4 Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 5 Minn. R. 7007, subp. 4 and 5 Minn. R. 7007, subp. 4 and 5 A-4

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: Subject Item: Associated Items: 12300410-001 GP 002 Rotogravure Press Operation CE 001 Direct Flame Afterburner w/heat Exchanger EU 005 Rotogravure Press 2 EU 006 Press 2 Dryer What to do VOC Usage: less than or equal to 61.4 tons/month using 12-month Rolling Average. VOC usage rate is determined using recordkeeping and equation in Appendix C. HAPs - Total: less than or equal to 20 percent of mass of solids applied for the month. This is for total organic HAPs. To meet this limit, the Permittee shall follow the next two requirements: The Permittee shall operate and maintain the thermal oxidizer any time that any process equipment controlled by the thermal oxidizer is in operation. HAPs - Total: less than or equal to 0.20 kilograms/kilograms. The Permittee is limited to less than or equal to 0.20 kg organic HAP emitted per kg solids applied as determined on a monthly average as-applied basis. Determination of Emission Rate: the Permittee shall determine the organic HAP emission rate based on solids applied, using the equations in Appendix C. The Permittee shall measure the mass of each ink, coating, varnish, adhesive, primer, solvent, and other material applied during the month and shall determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent, and other material applied during the month following the procedure in 40 CFR Section 63.827(b)(2). The Permittee shall also determine the solids content of each ink, coating, varnish, adhesive, primer, solvent, and other material applied during the month following the procedure in 40 CFR Section 63.827(c)(2). The Permittee has chosen to use the formulation data as provided in a Certified Product Data Sheet (CPDS) as obtained from the supplier. Monitoring Scenarios: The Permittee is authorized to install a new temperature monitoring system that will monitor the 3-hour rolling average temperatures on the thermal oxidizer. Prior to installation of such a system, the Permittee shall comply with and monitor for the absolute minimum temperature limit listed under Scenario 1. After installation of the system, the Permittee shall comply with and monitor for the 3-hour rolling average temperature limit under Scenario 2. Notify: due 30 days after Equipment Installation. The Permittee shall notify the MPCA when the installation of the new temperature monitoring system is complete. The notification shall include the date that the Permittee switched to Monitoring Scenario 2. MONITORING SCENARIO 1 Temperature: greater than or equal to 1250 degrees F absolute minimum at the Combustion Chamber unless a new minimum is set pursuant to Minn. R. 7017.2025, subp. 3, based on the average temperature recorded during the most recent MPCA approved performance test where compliance for VOC and/or HAP emissions was demonstrated. If the temperature drops below the minimum temperature limit, the VOC and HAP used during that time shall be considered uncontrolled until the minimum temperature limit is once again achieved. This shall be reported as a deviation. Monitoring and recording of temperature is required only when the emission source venting to the oxidizer is in operation. MONITORING SCENARIO 2 Temperature: greater than or equal to 1250 degrees F using 3-hour Rolling Average at the Combustion Chamber unless a new minimum is set pursuant to Minn. R. 7017.2025, subp. 3, based on the average temperature recorded during the most recent MPCA approved performance test where compliance for VOC and/or HAP emissions was demonstrated. If the 3-hour rolling average temperature drops below the minimum temperature limit, the VOC and HAP used during that time shall be considered uncontrolled until the average minimum temperature limit is once again achieved. This shall be reported as a deviation. Monitoring and recording of temperature is required only when the emission source venting to the oxidizer is in operation. MONITORING AND RECORDKEEPING REQUIREMENTS Performance Test: due before 03/01/2004 to measure HAPs destruction and collection efficiency of incinerator. This test is to be performed 5 years after initial compliance test for MACT (initial compliance test conducted 3/99). The Permittee shall maintain a continuous hard copy readout or computer disk file of the temperature readings for the combustion chamber. Once operating under Scenario 2, the Permittee shall also maintain the calculated three-hour rolling average combustion chamber temperature. Why to do it Title I Condition: 40 CFR Section 52.21(j) (BACT limit); Minn. R. 7007.3000 40 CFR pt. 63.825(b) Title I Condition: 40 CFR Section 52.21(j) (BACT); 40 CFR Section 63.825(b)(8); Minn. R. 7007.0800, subp. 2 and 14 40 CFR Section 63.825(b)(8); Minn. R. 7007.0800, subp. 2 40 CFR Section 63.825(d)(v) Minn. R. 7007.0800, subp. 11 Minn. R. 7007.0800, subp. 11 hdr 40 CFR section 63.825(d)(xi) hdr 40 CFR section 63.825(d)(xi) hdr Minn. R. 7007.0800, subp 4 Minn. R. 7007.0800, subp. 4 and 5 A-5

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 Daily Monitoring: The Permittee shall physically check the temperature recording device at least once each operating day to verify that it is working and recording properly. The Permittee shall maintain a written record of these checks. Monitoring Equipment: The Permittee shall install and maintain thermocouples to conduct temperature monitoring required by this permit. The monitoring equipment must be installed, in use, and properly maintained whenever operation of the monitored control equipment is required. The Permittee shall maintain and operate a thermocouple monitoring device that continuously indicates and records the combustion chamber temperature of the thermal oxidizer. The monitoring device shall have a margin of error less than the greater of +/- 0.75 percent of the temperature being measured or +/- 2.5 degrees Celsius. Under Scenario 2, the recording device shall also calculate the three-hour rolling average combustion chamber temperature. Annual Inspections: At least once per calendar year, the Permittee shall inspect the control equipment internal and external system components, including but not limited to the refractory, heat exchanger, and electrical systems. The Permittee shall maintain a written record of the inspection and any corrective actions taken resulting from the inspection. Annual Calibration: The Permittee shall calibrate the temperature monitor at least annually and shall maintain a written record of the calibration and any action resulting from the calibration. For periods when the thermal oxidizer is operated above the minimum combustion chamber temperature, the Permittee shall use either one of the following when completing calculations as required elsewhere in this permit: a. The overall control efficiency limit specified in this permit for this equipment (58%); or b. The overall control efficiency determined during the most recent MPCA approved performance test. If the tested efficiency is less than the efficiency limit in this permit, the Permittee must use the tested value in all calculations until the efficiency is demonstrated to be above the permit limit through a new test. Corrective Actions: If the temperature is below the minimum specified by this permit or if the thermal oxidizer or any of its components are found during the inspections to need repair, the Permittee shall take corrective action as soon as possible. Corrective actions shall return the temperature to at least the permitted minimum and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the thermal oxidizer. The Permittee shall keep a record of the type and date of any corrective action taken. The Permittee shall operate and maintain the thermal oxidizer in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. Hood Certification and Evaluation: The control device hood must conform to the requirements listed in Minn. R. 7011.0070, subp. 1, and the Permittee shall certify this as specified in Minn. R. 7011.0070, subp. 3. The Permittee shall maintain a copy of the certification on site, as well as an annual record of fan rotation speed, fan power draw, or face velocity of each hood, or other comparable air flow indication method. Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4 Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4, 5, and 14 Minn. R. 7007.0800, subp. 4, 5, and 14 Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4, 5, and 14 Minn. R. 7007.0800, subp. 14 Minn. R. 7007.0800, subp. 4, 5 and 14 A-6

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: Subject Item: Associated Items: 12300410-001 GP 003 Web Offset Presses CE 002 Direct Flame Afterburner w/heat Exchanger EU 007 Web Offset Press 3 EU 008 Press 3 Dryer EU 009 Web Offset Press 4 EU 010 Press 4 Dryer What to do Volatile Organic Compounds: less than or equal to 3.0 tons/month using 12-month Rolling Average to be calculated by the 15th day of each month for the previous 12-month period as described elsewhere and in Appendix C of this permit. VOC contents for each VOC-containing material shall be determined as described under the Material Content requirement in GP 006. Operating Hours: less than or equal to 8000 hours/year using 12-month Rolling Sum. This limit applies to each press separately. The Permittee shall operate and maintain the thermal oxidizer any time that any process equipment controlled by the thermal oxidizer is in operation. Monitoring Scenarios: The Permittee is authorized to install a new temperature monitoring system that will monitor the 3-hour rolling average temperatures on the thermal oxidizer. Prior to installation of such a system, the Permittee shall comply with and monitor for the absolute minimum temperature limit listed under Scenario 1. After installation of the system, the Permittee shall comply with and monitor for the 3-hour rolling average temperature limit under Scenario 2. Notify: due 30 days after Equipment Installation. The Permittee shall notify the MPCA when the installation of the new temperature monitoring system is complete. The notification shall include the date that the Permittee switched to Monitoring Scenario 2. MONITORING SCENARIO 1 Temperature: greater than or equal to 1325 degrees F absolute minimum at the Combustion Chamber unless a new minimum is set pursuant to Minn. R. 7017.2025, subp. 3, based on the average temperature recorded during the most recent MPCA approved performance test where compliance for VOC emissions was demonstrated. If the temperature drops below the minimum temperature limit, the VOC used during that time shall be considered uncontrolled until the minimum temperature limit is once again achieved. This shall be reported as a deviation. Monitoring and recording of temperature is required only when an emission source venting to the oxidizer is in operation. MONITORING SCENARIO 2 Temperature: greater than or equal to 1325 degrees F using 3-hour Rolling Average at the Combustion Chamber unless a new minimum is set pursuant to Minn. R. 7017.2025, subp. 3, based on the average temperature recorded during the most recent MPCA approved performance test where compliance for VOC and/or HAP emissions was demonstrated. If the 3-hour rolling average temperature drops below the minimum temperature limit, the VOC and HAP used during that time shall be considered uncontrolled until the average minimum temperature limit is once again achieved. This shall be reported as a deviation. Monitoring and recording of temperature is required only when an emission source venting to the oxidizer is in operation. MONITORING AND RECORDKEEPING REQUIREMENTS Monthly Recordkeeping -- Hours of operation: By the 15th of the month, the Permittee shall calculate and record the following: 1) The total hours of operation for the web presses for the previous calendar month using the daily operation records. 2) The 12 month rolling average of hours of operation for the previous 12-month period by summing the monthly hours of operation data for the previous 12 months. The Permittee shall maintain a continuous hard copy readout or computer disk file of the temperature readings for the combustion chamber. Once operating under Scenario 2, the Permittee shall also maintain the calculated three-hour rolling average combustion chamber temperature. Daily Monitoring: The Permittee shall physically check the temperature recording device at least once each operating day to verify that it is working and recording properly. The Permittee shall maintain a written record of these checks. Why to do it Title I Condition: Limit to avoid classification as major modifcation under 40 CFR Section 52.21 Title I Condition: Limit to avoid classification as major modification under 40 CFR Section 52.21 Title I Condition: Limit taken to avoid classification as a major source and modification under 40 CFR Section 52.21; Minn. R. 7007.0800, subp. 2 and 14 Minn. R. 7007.0800, subp. 11 Minn. R. 7007.0800, subp. 11 hdr Title I Condition: Limit taken to avoid classification as a major modification under 40 CFR Section 52.21; Minn. R. 7007.0800, subp. 2 and 14 hdr 40 CFR section 63.825(d)(xi) hdr Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4 and 5 A-7

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 Monitoring Equipment: The Permittee shall install and maintain thermocouples to conduct temperature monitoring required by this permit. The monitoring equipment must be installed, in use, and properly maintained whenever operation of the monitored control equipment is required. The Permittee shall maintain and operate a thermocouple monitoring device that continuously indicates and records the combustion chamber temperature of the thermal oxidizer. The monitoring device shall have a margin of error less than the greater of +/- 0.75 percent of the temperature being measured or +/- 2.5 degrees Celsius. Under Scenario 2, the recording device shall also calculate the three-hour rolling average combustion chamber temperature. Annual Inspections: At least once per calendar year, the Permittee shall inspect the control equipment internal and external system components, including but not limited to the refractory, heat exchanger, and electrical systems. The Permittee shall maintain a written record of the inspection and any corrective actions taken resulting from the inspection. Annual Calibration: The Permittee shall calibrate the temperature monitor at least annually and shall maintain a written record of the calibration and any action resulting from the calibration. For periods when the thermal oxidizer is operated above the minimum combustion chamber temperature, the Permittee shall use either one of the following when completing calculations as required elsewhere in this permit: a. The overall control efficiency limit specified in this permit for this equipment (76%); or b. The overall control efficiency determined during the most recent MPCA approved performance test. If the tested efficiency is less than the efficiency limit in this permit, the Permittee must use the tested value in all calculations until the efficiency is demonstrated to be above the permit limit through a new test. Corrective Actions: If the temperature is below the minimum specified by this permit or if the thermal oxidizer or any of its components are found during the inspections to need repair, the Permittee shall take corrective action as soon as possible. Corrective actions shall return the temperature to at least the permitted minimum and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O & M Plan for the thermal oxidizer. The Permittee shall keep a record of the type and date of any corrective action taken. The Permittee shall operate and maintain the thermal oxidizer in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. Minn. R. 7007.0800, subp. 4 Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4, 5, and 14 Minn. R. 7007.0800, subp. 4, 5, and 14 Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4, 5, and 14 Minn. R. 7007.0800, subp. 14 A-8

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 Subject Item: GP 004 Paper Machines, Boxboard Mill Associated Items: EU 013 CorMed Paper Machine 4 EU 014 CorMed Paper Machine 5 EU 015 Boxboard Mill 1 EU 016 Boxboard Mill 2 What to do Total Particulate Matter: less than or equal to 0.3 grains/dry standard cubic foot of exhaust gas unless required to further reduce emissions to comply with the less stringent limit of either Minn R. 7011.0730 or Minn. R. 7011.0735. This applies separately to each piece of industrial process equipment. Opacity: less than or equal to 20 percent opacity except for one six-minute period per hour of not more than 60 percent opacity. This applies separately to each piece of industrial process equipment. Periodic Monitoring: the Permittee shall perform proper maintenance of the paper and boxboard machines so as to prevent excessive amounts of particulate matter from being emitted from the associated stack/vents. Why to do it Minn. R. 7011.0710, subp. 1(A) Minn. R. 7011.0710, subp. 1(B) Minn. R. 7007.0800, subp. 4 A-9

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: Subject Item: Associated Items: 12300410-001 GP 005 Direct Heating Equipment CE 001 Direct Flame Afterburner w/heat Exchanger CE 002 Direct Flame Afterburner w/heat Exchanger EU 006 Press 2 Dryer EU 008 Press 3 Dryer EU 010 Press 4 Dryer EU 018 Clay Coater Dryer EU 019 Web Offset #3 Post-Coater (2 burners) EU 020 Web Offset #4 Post-Coater What to do Fuel Type: Natural gas only, by equipment design, except CE 001, which can also burn #2 fuel oil. Total Particulate Matter: less than or equal to 0.3 grains/dry standard cubic foot of exhaust gas unless required to further reduce emissions to comply with the less stringent limit of either Minn. R. 7011.0730 or Minn. R. 7011. 0735. This applies separately to each piece of direct heating equipment. Opacity: less than or equal to 20 percent opacity except for one six-minute period per hour of not more than 60 percent opacity. This applies separately to each piece of direct heating equipment. Sulfur Dioxide: less than or equal to 1.6 lbs/million Btu heat input This applies separately to each piece of direct heating equipment. Why to do it Minn. R. 7005.0100, subp. 35a Minn. R. 7011.0610, subp. 1(A)(1) Minn. R. 7011.0610, subp. 1(A)(2) Minn. R. 7011.0610, subp. 2(A)(1) A-10

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: Subject Item: Associated Items: 12300410-001 GP 006 All Press Operations Subject to MACT CE 001 Direct Flame Afterburner w/heat Exchanger CE 002 Direct Flame Afterburner w/heat Exchanger EU 005 Rotogravure Press 2 EU 006 Press 2 Dryer EU 007 Web Offset Press 3 EU 008 Press 3 Dryer EU 009 Web Offset Press 4 EU 010 Press 4 Dryer What to do Monthly Recordkeeping -- VOC Emissions. By the 15th of the month, the Permittee shall calculate and record the following: 1) The total usage of VOC containing materials for the previous calendar month using the material usage records. This record shall also include the VOC and solids contents of each material as determined by the Material Content requirement of this permit. 2) The VOC emissions for the previous month using the formulas specified in Appendix C of this permit. 3) The 12 month rolling sum VOC emissions for the previous 12 month period by summing the monthly VOC emissions data for the previous 12 months. MACT REQUIREMENTS Material Usage Recordkeeping: For ink and other materials used at the presses: The Permittee shall record and maintain the quantity of each ink material dispensed in the press operations; this shall be done using the existing system and shall be done on a per-job basis. For solvent, thinner, reducer, diluent, or other non-solids-containing material used with press operations: The Permittee shall record the amount and type of solvent material, whenever material is dispensed. Why to do it Minn. R. 7007.0800, subp. 4 and 5 hdr Title I Condition: Monitoring for BACT limt; monitoring for limit to avoid classification as major modification under 40 CFR 52.21; monitoring for MACT limit; MInn. R. 7007.0800, subp. 4 and 5 This shall be based on written usage logs and meter readings. The records shall be sufficient to correlate the material usage with the appropriate press. The records shall be sufficient to correlate the material usage with the appropriate press. Monthly Recordkeeping - HAP emissions. By the 15th of the month, the Permittee shall calculate and record the organic HAP emission rate based on solids applied, using the equations specified in Appendix C of this permit. The records shall include the monthly total of organic HAPs applied and monthly total of solids applied. The record shall also include the individual and total HAP contents of each HAP-containing material used in the previous month, as determined by the Material Content requirement of this permit. Material Content: HAPs contents in materials, shall be determined in accordance with 40 CFR Section 63.827(b)(2) and (c)(2). The Permittee may use a certified product data sheet (CPDS) provided by the manufacturer if the manufacturer supplies the information as required in 40 CFR Section 63.827(b)(2)(iii). Prior to construction or reconstruction of an "affected source" under the promulgated MACT standards, the Permittee must apply for and obtain an air emission permit. At all times the Permittee shall operate and maintain the emission unit subject to the MACT standard and its associated air pollution control equipment in a manner consistent with good air pollution control practices for minimizing emissions at least to the levels required by all relevant standards. Malfunctions shall be corrected as soon as practicable after their occurrence in accordance with the startup, shutdown, and malfunction plan. The Permittee shall prepare and implement a Startup, Shutdown, and Malfunction Plan (SSMP) for each of the emission units subject to Maximum Control Technology Standards by the applicable MACT standard compliance date. The compliance date for Subpart KK was 5/30/99; submpart JJJJ is not yet promulgated. The SSMP is a federally enforceable part of the permit and shall be prepared in accordance with 40 CFR Section 63.6(e)(3) and include requirements specified therein. The SSMP must be located at the plant site and must be kept updated. When the SSMP is updated, the Permittee must keep all previous versions of the SSMP for a period of 5 years. The Permittee must submit the SSMP when required. 40 CFR Section 63.829; Minn. R. 7007.0800, subp. 4 and 5 40 CFR Section 63.827(b)((2) and (c)(2); Minn. R. 7007.0800, subp. 4 and 5 40 CFR Section 63.5(b)(3) 40 CFR Section 63.6(e)(1)(i) 40 CFR Section 63.6(e)(1)(ii) 40 CFR Section 63.6(e)(3)(i); 40 CFR Section 63.6(e)(3)(v) A-11

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 During periods of startup, shutdown, and malfunction, the Permittee shall operate and maintain the source in accordance with the procedures specified in the startup, shutdown, and malfunction plan. A written SSMP must contain the minimum of the following information: 1. A procedure that documents how any startup, shutdown, or malfunction event that has occurred will be addressed and documented; 2. Information regarding the operation of the source and its associated pollution control devices during a startup, shutdown, or malfunction event in a manner consistent with good air pollution control practices for minimizing emissions at least to the levels required by all relevant standards; and 3. Adequate procedures for correcting malfunctioning process and/or air pollution control equipment as quickly as practicable. The Permittee shall maintain files of all information required by this part in a form suitable and readily available for expeditious inspection and review. The files should be retained for at least 5 years following the date of each occurrence, measurement, maintenance, corrective action, report, or record. Only the most recent two years of information must be kept on site. The Permittee shall maintain, at a minimum, the following information in the files: 1) the occurrence and duration of each startup, shutdown, or malfunction of operation; 2) the occurrence and duration of each malfunction of the air pollution control equipment; 3) all maintenance performed on the pollution control equipment; 4) actions taken during periods of startup, shutdown, and malfunction when such actions are different from the procedures specified in the affected source's startup, shutdown, and malfunction plan (SSMP). In this case, the Permittee shall report this action within 2 days of occurrence and follow by a written notification within 7 days of occurrence. 5) all information necessary to demonstrate conformance with the affected source's SSMP and actions taken in accordance with SSMP; 6) each period during which a continuous monitoring system (CMS) is malfunctioning or inoperative; 7) all required measurements needed to demonstrate compliance with a relevant standard; 8) all results of performance test, CMS performance evaluations, and opacity and visible emission observations; 9) all measurements as may be necessary to determine the conditions of performance tests and performance evaluations; 10) all CMS calibration checks; 11) all adjustments and maintenance performed on CMS; 12) any information demonstrating whether a source is meeting the requirements for a waiver of record keeping or reporting requirements under this part; 13) all documents supporting initial notifications and notifications of compliance status. Startup, shutdown, and malfunction reports shall be submitted only if there is an occurrence of startup, shutdown, or malfunction during the reporting period and shall be delivered or postmarked by the 30th day following the end of each calendar half year. If the Permittee deviates from the startup, shutdown, and malfunction plan (SSMP) during a startup, shutdown or malfunction, the Permittee shall record the actions taken for that event and report such actions within 2 working days after commencing actions inconsistent with the plan, followed by a letter within 7 working days after the end of the event. The report must contain name, title, and signature of a responsible official who is certifying its accuracy, explaining the circumstances of the event, the reasons for not following the SSMP, and whether any excess emissions and/or parameter monitoring exceedances are believed to have occurred. 40 CFR Section 63.6(e)(3)(ii); 40 CFR Section 63.6(e)(3)(iii) 40 CFR Section 63.6(e)(3)(vii) 40 CFR Section 63.10(b)(1) 40 CFR Section 63.10(b)(2) 40 CFR Section 63.10(b)(2) 40 CFR Section 63.10(d)(5)(i) 40 CFR Section 63.6(e)(3)(iv); 40 CFR Section 63.10(d)(5)(ii) A-12

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 Subject Item: EU 004 Boiler 4 Associated Items: GP 001 Boilers SV 002 What to do Capacity: less than or equal to 232 million Btu's/hour. This is derated heat input used in modeling for PM SIP. Minn. R. 7009.0080 Why to do it A-13

TABLE A: LIMITS AND OTHER REQUIREMENTS 04/17/03 Facility Name: Waldorf Corp - A Rock-Tenn Co Permit Number: 12300410-001 Subject Item: EU 017 CorMed Web Welder Associated Items: CE 003 Wet Cyclonic Separator - Wet Cyclone SV 010 What to do Total Particulate Matter: less than or equal to 0.3 grains/dry standard cubic foot of exhaust gas unless required to further reduce emissions to comply with the less stringent limit of either Minn. R. 7011.0730 or Minn. R. 7011. 0735. Opacity: less than or equal to 20 percent opacity Pressure Drop: greater than or equal to 40 inches of water column. This is measure of feed water pressure to the cyclone. MONITORING AND RECORDKEEPING REQUIREMENTS Control Equipment Monitoring: Observe and record once per operating day, the pressure drop for CE 003 (rotoclone). Control Equipment Monitoring: The Permittee shall visually check proper operation of the rotoclone, through the inspection port, at least once each operating day to verify that the rotoclone is working properly. Recordkeeping of Pressure Drop. The Permittee shall record the time and date of each pressure drop reading and whether or not the recorded pressure drop was within the range specified in this permit. Corrective Actions: If the monitored parameter is out of the range as described above, the Permittee shall take corrective action as soon as possible. Corrective actions shall return the pressure drop to the specified range and/or include completion of necessary repairs identified during the inspection, as applicable. Corrective actions include, but are not limited to, those outlined in the O&M Plan for the rotoclone. The Permittee shall keep a record of the type and date of any corrective action taken. The Permittee shall operate and maintain the rotoclone at all times that any emission unit controlled by the rotoclone is in operation. The Permittee shall operate and maintain the rotoclone in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. Monitoring Equipment: The Permittee shall install and maintain the necessary monitoring equipment for measuring and recording pressure drop as required by this permit. The monitoring equipment must be installed, in use, and properly maintained when the monitored rotoclone is in operation. Periodic Inspections: At least once per calendar quarter, or more frequently as required by the manufacturing specifications, the Permittee shall inspect the control equipment components. The Permittee shall maintain a written record of these inspections. The Permittee shall operate and maintain the rotoclone in accordance with the Operation and Maintenance (O & M) Plan. The Permittee shall keep copies of the O & M Plan available onsite for use by staff and MPCA staff. Why to do it Minn. R. 7011.0715, subp. 1(A) Minn. R. 7011.0715, subp. 1(B) Minn. R. 7007.0800, subp. 4 and 5 hdr Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4 and 5 Minn. R. 7007.0800, subp. 4, 5, and 14 Minn. R. 7007.0800, subp. 2 and 14 Minn. R. 7007.0800, subp. 4 Minn. R. 7007.0800, subp. 4, 5 and 14 Minn. R. 7007.0800, subp. 14 A-14