Model Plasma Cleaner. Effectively cleans specimens for electron microscopy EXCELLENCE MAGNIFIED

Similar documents
MODEL Plasma Cleaner. Simultaneously cleans specimen and specimen holder. Cleans highly contaminated specimens in 2 minutes or less

Model TEM Mill. Tabletop precision preparation for producing high-quality TEM specimens from a wide variety of materials EXCELLENCE MAGNIFIED

MODEL NanoMill TEM Specimen Preparation System. Ultra-low-energy, inert-gas ion source. Concentrated ion beam with scanning capabilities

MODEL SEM Mill. Two independently adjustable TrueFocus ion sources

MODEL 1051 TEM Mill ION MILLING. Ion milling is used on physical science. specimens to reduce thickness to electron

MODEL PicoMill TEM specimen preparation system. Achieve ultimate specimen quality free from amorphous and implanted layers

MODEL TEM Mill. Two independently adjustable TrueFocus ion sources

MODEL 1061 SEM Mill ION MILLING. Ion milling is used in the physical. sciences to enhance the sample s surface. characteristics. Inert gas, typically

Specimen configuration

Observation in the GB (Gentle Beam) Capabilities

Differentially pumped quadrupole SIMS probe on FIBbased and two-beam microscopes

Q150R Series Rotary Pumped Coaters

METHOD FOR IMPROVING FIB PREPARED TEM SAMPLES BY VERY LOW ENERGY Ar + ION MILL POLISHING

The principles and practice of electron microscopy

Heteroepitaxy of Monolayer MoS 2 and WS 2

Specimen Preparation Technique for a Microstructure Analysis Using the Focused Ion Beam Process

Scanning Electron Microscope & Surface Analysis. Wageningen EM Centre Marcel Giesbers

Production of Few-Layer Phosphorene by Liquid Exfoliation of Black Phosphorus

Biomimetic synthesis of gold nanocrystals using a reducing amphiphile. Ferdinand Gonzaga, Sherdeep Singh and Michael A. Brook. Department of Chemistry

High Performance Lithium Battery Anodes Using Silicon Nanowires

From Eye to Insight. Leica EM ACE. Coater Family

Influence of Alloy Microstructure on Oxide Growth in HCM12A in Supercritical Water

Quantitative X-ray Microanalysis Of Submicron Carbide Formation In Chromium (III) Oxide Rich Scale

A Study of Additive Diffusion in Ferrous Powder Metal Compacts Using Scanning Electron Microscopy and Energy Dispersive X-Ray Spectroscopy

Quantitative Analysis of Atomic-scale Alloying Elements Using TEM

Supporting Information. Solution-Processed 2D PbS Nanoplates with Residual Cu 2 S. Exhibiting Low Resistivity and High Infrared Responsivity

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE


A STUDY OF THE EFFECTIVENESS OF THE REMOVAL OF HYDROCARBON CONTAMINATION BY OXIDATIVE CLEANING INSIDE THE SEM.

Electron Probe Micro-Analysis (EPMA)

Supplementary Information. Capacity fade in high energy silicon-graphite electrodes for lithium-ion batteries

MicroscopyAND. Microanalysis MICROSCOPY SOCIETY OF AMERICA Plasma Cleaning and Its Applications for Electron Microscopy INTRODUCTION

Surface Composition Analysis of a Degraded Copper Plate and Scrapings from The Inner Surface of An SRF Coupler

JSM-7800F Field Emission Scanning Electron Microscope

Plasma Quest Limited

Microstructure Analysis by Means of the Orthogonallyarranged

What is SEM? TM-1000 Tabletop Microscope

Supporting Information. Low temperature synthesis of silicon carbide nanomaterials using

Practical 2P8 Transmission Electron Microscopy

Transmission Electron Microscopy (TEM) Prof.Dr.Figen KAYA

Simple method for formation of nanometer scale holes in membranes. E. O. Lawrence Berkeley National Laboratory, Berkeley, CA 94720

Strategies for Cleaning EUV Optics, Masks and Vacuum Systems with Downstream Plasma Cleaning

Downstream Plasma Technology for Cleaning TEM Samples on Carbon Films

Application Note. Sample Protection prior to FIB Processing. related instruments: Leica EM ACE600. Material Research. Life Science Research

ECE 541/ME 541 Microelectronic Fabrication Techniques

INA-X System for SNMS and SIMS

Downstream Plasma Technology for Cleaning TEM Samples on Carbon Films

Thin Films: Sputtering Systems (Jaeger Ch 6 & Ruska Ch 7,) Can deposit any material on any substrate (in principal) Start with pumping down to high

Korkealämpötilaprosessit

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Supporting Information

PHASE SEPARATION BY INTERNAL OXIDATION AND REDUCTION IN A Cu-5at%Ni-ALLOY

Practical 2P8 Transmission Electron Microscopy

Thin Films: Sputtering Systems (Jaeger Ch 6 & Ruska Ch 7,) Sputtering: gas plasma transfers atoms from target to substrate Can deposit any material

A NEW APPROACH TO STUDYING CAST CB2 STEEL USING SLOW AND VERY SLOW ELECTRONS

IBS/e Ion Beam Sputter Deposition and Etching System. IBS/e with KDC-10 Ion Beam Sputter Deposition and Etching System with Kaufman Ion Source

Formation of High-quality Aluminum Oxide under Ion Beam Irradiation

CHARGED PARTICLE PHYSICS BRANCH CODE 6750

SEM (SCANNING ELECTRON MICROSCOPE)

Cross sectional TEM analysis of duplex HIPIMS and DC magnetron sputtered Mo and W doped carbon coatings

The Study of SEM Examination of Crept Ceramic Samples Prepared by Cross Polishing Method

Cross sectional TEM analysis of duplex HIPIMS and DC magnetron sputtered Mo and W doped carbon coatings

The Hummer VI. Brian Thomas Lithography. October 29, Hummer VI THE UNIVERSITY OF TEXAS AT DALLAS ERIK JOHNSON SCHOOL OF ENGINEERING

Transactions on Engineering Sciences vol 2, 1993 WIT Press, ISSN

Plasma Surface Treatment

temperature and process technology

Electron Microscopy Sciences

Visualization of Nano-precipitate in Low-alloy Steel by Using Energy-filtered Transmission Electron Microscopy

STUDY & ANALYSIS OF ALUMINIUM FOIL AND ANATASE TITANIUM OXIDE (TiO2) USING TRANSMISSION ELECTRON MICROSCOPY

3D Nano-analysis Technology for Preparing and Observing Highly Integrated and Scaled-down Devices in QTAT

PoDFA The complete solution for inclusion measurement Inclusion identification and quantification analysis

Platypus Gold Coated Substrates. Bringing Science to the Surface

National Institute of Technology Calicut

Supplementary Information

Supporting information

Advanced Materials Analysis with Micro-XRF for SEM

Sr and Pb additions. L. Affleck, C. Leach *

Spectroscopy Performance Note

Thermo Scientific ARL EQUINOX 100. X-ray Diffractometers

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Silver Diffusion Bonding and Layer Transfer of Lithium Niobate to Silicon

Surface Layer Characterization of Atomized Magnesium for use in Powder Metallurgy Products Paul Burke and Georges J. Kipouros

Microstructural Characterization of Materials

BAF 060 Freeze-Fracture System

Supplementary Information

EDS Phase Mapping of a Contact Metamorphosed Calc-Silicate Rock

ENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code)

Plasma Surface Treatment

Crystallographic Textures Measurement

AP 5301/8301 LABORATORY MANUAL

Journal of Chemical and Pharmaceutical Research, 2017, 9(1): Research Article

Supporting information

Supporting Information

Supporting Information for Surface-energy induced formation of single crystalline. bismuth nanowires over vanadium thin film at room temperature

Growth of monocrystalline In 2 O 3 nanowires by seed orientation dependent vapour-solid-solid mechanism

Supplementary Information

3-ways to clean optical samples for better deep UV performance measurements

Transzmissziós és pásztázó elektronmikroszkópos minták készítése ionsugaras vékonyítással

Author(s) Chayahara, A; Kinomura, A; Horino, RightCopyright 1999 American Vacuum Soci

Transcription:

Model 1020 Plasma Cleaner Effectively cleans specimens for electron microscopy EXCELLENCE MAGNIFIED

Model 1020 Plasma Cleaner Simultaneously cleans specimen and specimen holder. Cleans highly contaminated specimens in 2 minutes or less. No change to the specimen s elemental composition or structural characteristics. Oil-free vacuum system. Easy-to-use front panel controls. Readily accepts side-entry specimen holders for all commercial TEMs and STEMs. For SEM as well as other surface science techniques. Handy for evacuating specimen holder Vacuum Storage Containers. Model 1020 Plasma Cleaner removes organic contamination from physical science specimens and specimen holders. Electron microscopy requires clean specimens Clean, well-prepared specimens are imperative for imaging and microanalysis in electron microscopy. Transmission electron microscopy (TEM) analysis requires that specimens be prepared without altering their microstructure or composition. Modern electron microscopes with high brightness electron sources such as LaB 6 filaments and field emission guns (FEG) combine a small electron probe for microanalysis with increased beam current density, yielding highresolution images as well as enhanced analytical data. Unfortunately, as probe size decreases and beam current density increases, specimens tend to become contaminated. As a result, the quality of the specimen and the cleanliness of both the specimen and the specimen holder are more important than ever. Contamination typically comes from several sources: inadvertent touching of specimens or specimen holders, backstreaming of oil from an oil diffusion pumped ion milling system, electron microscope column contamination, and adhesives or solvents used in the preparation process. Even when great care is taken to clean the specimen, standard cleaning methods are often not 100% successful.

Model 1020 for final cleaning The Model 1020 Plasma Cleaner cleans specimens immediately before they are inserted into the electron microscope. Plasma cleaning both removes existing carbonaceous debris from the specimen and also prevents contamination from occurring during imaging and analysis. A low-energy, inductively-coupled, high frequency (HF) plasma effectively cleans a specimen surface without changing its elemental composition or structural characteristics. Highly contaminated specimens can be cleaned in two minutes or less. The Model 1020 readily accepts side-entry specimen holders for all commercial TEMs and STEMs and can accept bulk specimens for cleaning before conducting scanning electron microscopy (SEM) or surface analysis. Plasma cleaning In a nonequilibrium, high frequency plasma, free electrons are accelerated to high velocities by an oscillating electromagnetic field that excites gas atoms and creates the plasma. The plasma ions impinge upon the surface with energies of less than 12eV, which is below the specimen s sputtering threshold. Cleaning is solely by reactive gas compounds formed by the plasma chemically reacting with carbonaceous material on the specimen and specimen holder. To optimize cleaning, a mixture of 25% oxygen and 75% argon is generally recommended. An oxygen plasma is highly effective in removing organic (hydrocarbon) contamination. The reaction yields H 2 O, CO, and CO 2 that are evacuated by the vacuum system. Clean specimens and holders A wide variety of materials, prepared by a number of preparation techniques, can be plasma cleaned by the Model 1020 and yield identical results no contamination of the sample under the electron beam. The plasma chamber configuration makes it possible to clean specimen holders for any commercially available TEM or STEM. The specimen holder is inserted through a single port into the plasma chamber. The port contains a vacuum-sealing surface compatible with the specimen holder s o-ring. Ports are available for side entry specimen holders for FEI/Philips, Hitachi, JEOL, Zeiss/LEO, and Topcon TEMs. Ports are easily interchangeable without tools in as little as 10 seconds. continued 1

Model 1020 Plasma Cleaner Clean specimens and holders (continued) For cleaning specimens containing significant amounts of carbon or those mounted onto carbon support grids, shielded specimen holder ports are available that optimize the cleaning action of the plasma. The large diameter plasma chamber and specially designed holders accommodate bulk specimens for SEM as well as other surface science techniques. Likewise, aperture strips, specimen clamping rings, and SEM specimen holders can also be cleaned. Typical TEM Specimen Holder Port Shielded Specimen Holder Port Multiple Specimen Holder; SEM stubs Clamp-Grip Holder for retaining bulk materials Multiple Specimen Holder for TEM specimens 2

Imaging can proceed with confidence Plasma cleaning is an essential final step in the preparation of specimens for electron microscopy. Using the Model 1020 Plasma Cleaner ensures confidence that carbonaceous contamination will not interfere with imaging or analysis, even during fine probe microanalysis for extended periods. Plasma cleaning results: TEM TEM image of a stainless steel (grade 304) specimen after one minute of plasma cleaning. The black spots are where a 5nm probe from a Hitachi HF-2000 cfeg-tem was converged on the specimen before plasma cleaning. The numbers next to the spots correspond to how long (in minutes) the probe was held in that position. After plasma cleaning with a process gas mix of 25% oxygen in argon, the probe was converged on the specimen and held for five minutes at the position indicated by the arrow. No contamination of the specimen is evident. TEM image of a strontium titanate (SrTiO 3 ) bicrystal after 1 minute of plasma cleaning. This was done in the same manner as the stainless steel specimen above. Contamination spots are from fine probe microanalysis performed on the specimen prior to the initial plasma cleaning. Again, note the lack of contamination at the position indicated by the arrow. Also note the hole to the upper left of the image showing an edge of carbonaceous contamination. TEM image of a strontium titanate (SrTiO 3 ) bicrystal after an additional 4 minutes of plasma cleaning. The contamination spots are greatly diminished or even removed. After 5 minutes of total plasma cleaning, the edge of contamination on the hole has also been removed. 3

Model 1020 Plasma Cleaner Plasma cleaning results: STEM (EDX) Before After Energy dispersive x-ray (EDX) spectra of a Cu-Al alloy before and after one minute of plasma cleaning. After plasma cleaning, no carbon is detected by EDX. Furthermore, note the lack of argon or oxygen, as would be detected if the Model 1020 implanted ions into or oxidized the specimen. Likewise, no iron, chromium, nickel, fluorine, or silicon are detected by EDX, indicating that no sputtering of plasma chamber constituents occurred. Plasma cleaning results: EELS A measure of specimen contamination rate can be analytically determined by electron energy loss spectroscopy (EELS). The mass thickness of a specimen can readily be established as a function of time. If the specimen is contaminating, this thickness will increase as the electron probe is held on the specimen. Electron energy loss spectroscopy plotting mass thickness versus time for a Si specimen. Before plasma cleaning, the specimen contaminates quickly, and continues to do so after the probe has been held in place for 10 minutes. After only one minute of plasma cleaning, holding the probe on the specimen for 10 minutes results in no change in the specimen thickness indicating the absence of specimen contamination. 4

Plasma cleaning results: SEM (EDX) The benefits of plasma cleaning are not solely applicable to TEM. By removing the TEM specimen holder port and replacing it with an appropriate holder, bulk specimens can be introduced into the plasma for cleaning. Thus, specimens for surface science and SEM analysis can be cleaned as well as SEM specimen holders, aperture strips, tweezers, specimen clamping rings, and anything else that can be placed into the plasma chamber. Before After SEM images of silicon acquired in the secondary electron (SE) imaging mode before and after 5 minutes of plasma cleaning. Before cleaning, the image shows black carbonaceous spots that were formed by converging the electron beam in those positions for EDX analysis. The black boxes were formed by rastering the probe at those positions while the specimen was being imaged at a higher magnification. The image of the same specimen region after cleaning shows that all black spots and the black boxes have been eliminated by plasma cleaning and no contamination effects appeared subsequently. Before After SEM (EDX) spectra of a bulk silicon specimen before and after 2 minutes of plasma cleaning. The SEM was operated in spot mode at an accelerating voltage of 5kV with an accumulated live time of 300 seconds. Before cleaning, the image shows a large carbon peak on the spectrum. After plasma cleaning for two minutes using the gas mixture of 25% oxygen in argon, the carbon peak is greatly reduced. 5

Model 1020 Plasma Cleaner SE image (1kV) of gold on carbon, before plasma cleaning. Image courtesy of M. Hayles, FEI Company (The Netherlands) SE image (1kV) of gold on carbon, after 30 seconds of plasma cleaning. Image courtesy of M. Hayles, FEI Company (The Netherlands) SE image (3kV) of TiN coated Si before plasma cleaning. Image courtesy of R. Kirtz, FhG IMS (Germany) SE image (3kV) of TiN coated Si after 30 seconds of plasma cleaning. Image courtesy of R. Kirtz, FhG IMS (Germany) AFM tip following two minutes of plasma cleaning. 6

Plasma cleaning results: EBSD Plasma cleaning works well for electron backscatter diffraction (EBSD) analysis, which is a highly surface-sensitive technique. The first requirement is a properly prepared surface. Subsurface damage caused by mechanical or chemical polishing has to be removed, which is easily achievable with the Fischione Model 1010 Ion Mill. The Model 1010 accelerates argon ions toward the specimen surface. Through momentum transfer, material is sputtered from the specimen, resulting in the removal of surface artifacts. The final treatment by plasma cleaning removes contaminants from the ion milled surface. Before After EBSD before and after two minutes of plasma cleaning on a silicon specimen. Plasma chamber The plasma is created in a cylindrical chamber made of quartz and stainless steel. Sophisticated gas dynamics ensure that the plasma is evenly distributed within the chamber to clean the specimen with negligible heating. A high frequency (HF) antenna, located outside the chamber, couples the oscillating field to the chamber. No components are located within the chamber other than the specimen and specimen holder that are being cleaned. Vacuum system An oil-free vacuum system is essential to prevent contamination and ensure optimal processing. The vacuum system for the Model 1020 consists of a turbomolecular drag pump and a multi-stage diaphragm pump, an ideal combination for establishing suitable vacuum characteristics to activate and sustain the plasma. Rapid chamber pump-down times allow plasma cleaning to begin almost immediately after a specimen is inserted. The Model 1020 can also be used to evacuate individual specimen holder Vacuum Storage Containers and cyrotransfer TEM specimen holder dewars. A port plug seals the chamber under vacuum when the instrument is not in use. 7

Model 1020 Plasma Cleaner Power supply The high-frequency (13.56 MHz) oscillating power supply can initiate and sustain a low-energy, inductively-coupled plasma. A matching network ensures effective coupling of the high-frequency field to the plasma chamber and ensures compatibility with specimen holders produced for diverse TEMs. Effective shielding prevents the emission of high frequency interference, and fully complies with FCC guidelines. Front panel controls and display The control panel is especially easy to use. Dedicated keys control the vacuum pumping and venting sequence. LEDs indicate when the system is venting, at atmospheric pressure, pumping, and has achieved a high vacuum condition. A numeric touchpad is used to enter the plasma processing time. Once the control system determines that appropriate conditions have been established for effective processing, the plasma is automatically activated. A digital display continuously indicates the remaining processing time. Cleaning ends automatically when the specified time has elapsed. A visual indicator notifies the user that plasma cleaning is complete and the specimen is ready for imaging and analysis. Model 1020 Plasma Cleaner control panel Front access to services A service panel located on the front of the instrument s enclosure provides access to a potentiometer that controls the gas flow metering valve, the HF power control, and function switches used for diagnostic purposes. A digital display indicates the vacuum level and an hour meter tracks the vacuum system s total operating time so that routine maintenance can be scheduled accordingly. 8

Model 1020 Plasma Cleaner Accessories Model 9010 Vacuum Storage Container Model 9010 Vacuum Storage Container. After cleaning, specimen holders can be inserted into Model 9010 Vacuum Storage Containers so they can be stored or transported in a vacuum. A sight glass gives a clear view of the specimen area of the specimen holder. Model 9020 Vacuum Pumping Station Model 9020 Vacuum Pumping Station installed on the Plasma Cleaner. The Pumping Station simultaneously stores five specimen holders under vacuum. It includes a heavy-duty metal base with non-skid feet, five independently valved Vacuum Storage Containers, a vacuum pumping manifold, and all necessary components for connecting to the Model 1020 Plasma Cleaner. 9

Model 1020 specifications Plasma system Vacuum system Gas Dimensions Weight User interface Power requirements Warranty High frequency (13.56 MHz) oscillating field system coupled to a quartz and stainless steel plasma chamber Ion energies less than 12eV Compatible with TEM specimen holders for FEI/Philips, Hitachi, JEOL, Zeiss/LEO, and Topcon Oil-free turbomolecular drag pump backed by a multi-stage diaphragm pump Ultimate vacuum of 1 x 10-7 mbar 25% oxygen and 75% argon Nominal 10 psi (200 kpa) delivery pressure Flow rate is factory set and can be adjusted via a potentiometer located on the service panel 23" (584mm) W x 20.5" (521mm) H x 22.3" (566mm) D 133.5 lb (60.6 kg) Single control panel to initiate vacuum, plasma, and timer Process timer for automatic termination Service panel is easily accessible 100/120/220/240VAC, 50/60Hz, 660 watts Two year U.S. Patent Number 5,633,502, Dated May 27, 1997 U.S. Patent Number 5,510,624, Dated April 23, 1996 (licensed from the Argonne National Laboratory) Cover image: ADF-STEM (Gaussian smoothed) image of LaTiO 3 multilayers in SrTiO 3. Atomic columns of La, Sr, and Ti can be seen. Image courtesy of D.A. Muller, J. Grazul, A. Ohtomo, H. Hwang, Lucent Technologies (U.S.A.) EXCELLENCE MAGNIFIED E.A. Fischione Instruments, Inc. 9003 Corporate Circle Export, PA 15632 USA Tel: 724.325.5444 Fax: 724.325.5443 E-mail:info@fischione.com Website: www.fischione.com Part No. 011-0549, Rev. 1