SMART FIXING SYSTEMS profiles pro ofilees

Similar documents
SMART FIXING SYSTEMS

Method Statement - Installation Guide KX05 (Trespa TS300)

VENTILATED FACADES. Technical Manual

HunterDouglas NBK Ceramic TERRART [Large/Mid/Shingle/Light/Baguette) Terracotta Façade System

mounting systems applications overview

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

Sliding Door Systems

S7 Taifun Installation Manual

ARCHITECTURAL WALL PANELS APPLIED OVER A SHEATHED STUDWALL BY MEANS OF A FIELD ASSEMBLED TEN66 SUB-FRAME SYSTEM

VENTILATED FACADES. Technical Manual MFT MFI MFT MFI MFT MFI

SYSTEM S7-RHOMBOS INSTALLATION MANUAL

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

SYSTEM S4-RHOMBOS INSTALLATION MANUAL

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

National technical approval

MFT-S2S-1L- ADHESIVE- RIVETS-SCREWS. Hilti facade system

the knowledge to produce solutions Total Facade Solutions

S4 Taifun Installation Manual

Insulating systems used in agricultural and industrial buildings

SYSTEM ATHMOS INSTALLATION MANUAL

For more information on Pictura visit CI/SfB (41) R December New. Pictura. High performance cladding

General Design Approval

Flat roof for the loading-optimized elevation (adhesive system)

Rainspan ArGeTon. Part of Eurobond Laminates range of architectural facade systems

Technical Document of Rediwa C.A.T 3 Concealed System

Table of Contents. Certificates and approvals Colour palette...52

Curtain Wall Stick System (Capped)

NVELOPE Brackets NVELOPE NVELOPE NVELOPE NVELOPE NVELOPE NVELOPE NVELOPE

Technical Document of C.A.T 3 Ventilated Façade System

Conergy SolarFamulus II

Symmetrical Cladding. Laying instructions

INSTRUCTIONS FOR USE

Translation from German (14 pages in all) Translation of the German original version not revised by the Deutsches Institut für Bautechnik

DICTATOR Lift Shaft System

APPENDIX E KALZIP FAÇADE SYSTEM

ADS "TONALITY " Adaptive system 26. Description. 1 Basics. 2 Typical details. 3 List of components. Survey of drawings

Rainscreen Framing. Solutions

ALUMINIUM Systems. Prefabricated add-on balcony systems. ECOLOGY, SAFETY, QUALITY AT ITS HIGHEST LEVEL copal-balcony.com CERTIFICATION CERTIFICATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

Façade claddings. Sandwich panel SPA, SPB W, SP2D W

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

Façade panels riveted on an aluminium supporting structure

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

TERRART LIGHT. Terracotta Façades

Sound-absorbing and sound-insulating barriers

THE TERRACOTTA FAÇADE. ArGeTon

Kalzip FC rainscreen system

Unitised Curtain Wall Beaded

70S - 132S SUN LOUVRE. Sun Control Systems

Revolutionary Spacer Support Bar and Bracket System for Built Up, Twin Skin Roofing and Cladding Applications

MOUNTING SYSTEMS FOR TRAPEZOIDAL SHEET AND CORRUGATED SHEET ROOFS

ConSole, ConSole+ Flat-roof mounting system for PV-modules and -laminates. From visions to solutions

Design Manual Facade, riveted Panel fixed to T-Sections

Advantages. - They are quick, clean and. sizes, floor types and construction systems mean the mezzanines can be adapted to meet specific client needs.

HOISKO CLT SN 001. CLT external corner. CLT internal corner. CLT joining details. CLT element wall. Screw 8,0*220 k300 21*145. Seal CLT element wall

SECTION VIBRATION ISOLATION

Exterior Wall Solutions Building Shell

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

EN 1065 ULTRADECK SLAB SYSTEM

Light steel frame walls

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Expand your horizons... High quality Aluminium Door & Window Systems Folding Doors Slide & Turn Doors Sliding Doors Windows

SGL2100 Sliding Systems

ACM. Product Data Sheet

Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) Operating vacuum pressure: - 500Pa

Performance proven fastening system

SECTION PHENOLIC LOCKERS AND BENCHES. B. Section Gypsum Board Area Separation Wall Assemblies.

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

15/06/ Clippers Quay. Salford Manchester.

SECTION COLD-FORMED METAL TRUSSES

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

against falling ( Bauteile, die gegen Absturz sichern ) must be observed.

Mounting instructions. novotegra for trapezoidal metal - roof parallel

lindab we simplify construction LindabSmoke control system single compartment Rectangular Mounting instruction

CAR PARK CLADDING FULL DESIGN, SUPPLY AND INSTALLATION SERVICE

EasylationWall. External Wall Insulation System. bringing european innovation

TRAPEZOIDAL SHEET METAL RAIL

Non-rigit-PVC. Soft PVC strips

RUUKKI FORMA DESIGN INSTRUCTION

PROTEKTOR PROFILES FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

Architect: Bruno Marques Photographer: AFFP Filipe Pombo TOPAZE CONTEMPORARY SLIDER

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS

MILT-Pro. Built-in units and control centres for halls

INDIVIDUAL STORAGE AND LOGISTICS SOLUTIONS WITH GRATINGS AND PERFORATED METAL PLANKS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

RUUKKI FAÇADE SYSTEMS

OKAPOINT Point Supported Insulating Glass

RAINSCREEN CLADDING. Bespoke secret fix Rainscreen cladding system available in range of materials and finishes. Delivering your design

Textura Façade panel Product information sheet 1

AT A GLANCE. All you need to know about the honeycomb composite panel. English

PARTITIONS & EXTERNAL WALLS 5

SYSTEM W-H 1100 Wall cladding. Metal product

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

Transcription:

SMART FIXING SYSTEMS profiles

2 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com

REAR-VENTILATED FACADE The hung, rear-ventilated facade (RVF) covers the load bearing wall of a building. With a RVF, the facade elements are mounted with the help of a fixing system at a distance from the building s outside wall. Besides the varied architectural possibilities, this method of construction has considerable ecological and economical benefits:. The RVF protects against weather conditions and contributes to the longevity of the building. The outside wall of the building and the thermal insulation remain dry always.. The RVF minimises thermal stress and is the optimum protection against heat and cold.. The RVF is an energy-saving façade. The variable lengths of wall brackets make it possible to install with any desired thickness of insulation. Energy savings leads to minimisation of carbon dioxide discharge.. Back ventilating the façade controls the humidity of the building and ensures an optimum climate inside.. The multilayered structure of RVF protects against noise.. The RVF system guarantees sustainable construction through recycling the components that are used. SYSTEM F1.10 SYSTEM F2.10 1 2 1 CONSTRUCTION OF THE RVF 5 2 3 1 Load bearing wall 2 Insulation 3 Ventilation space 4 Facade panel 5 Allface substructure 5 3 4 4 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com 3

ALLFACE SMART FIXING SYSTEMS The critical element and basis of a fixing system is the wall bracket. It decides the layout of the facade s substructure. WALL BRACKET F1 Wall bracket F1 is used for vertical fixing on solid walls. F1 A B Technical Features and Benefits. Wind pressure is passed right to the building element no tensile load on the dowel.. Each F1 can be used for a fixed point or a sliding point. The F1+ is mainly used as an anchor point. It has high load bearing capacity due to its design with a height of 175 mm combined with 2 wall fixing points.. Dowel spacing of 125 mm for the F1+ makes it possible to fasten to a problematic subgrade.. Integrated clamp-slide provides 38 mm of adjusting for the L- or T-profiles.. Made of aluminium EN-AW 6060 T66 F1+ 90 A B Wall Bracket Throat depth A* Distance to Wall B F1.35 35 mm 37 75 mm F1.50 50 mm 52 90 mm F1.80 80 mm 82 120 mm F1.100 100 mm 102 140 mm F1.115 115 mm 117 155 mm F1.135 135 mm 137 175 mm F1.150 150 mm 152 190 mm F1.170 170 mm 172 210 mm F1.185 185 mm 187 225 mm F1.220 220 mm 222 260 mm F1.255 255 mm 257 295 mm 175 A B * other throat depths on request F2 WALL BRACKET F2 The wall bracket F2 is mainly used for horizontal fixings on beam- and column constructions. Technical Features and Benefits High bearing capacity due to the design.. For mounting on beam- and column structures. Each F2 can be used for a fixed point or a sliding point. The F2+ primary use is as a fixed point, due to its high load bearing capacity.. Integrated clamp-slide provides 38 mm of adjusting for the horizontal profiles.. Made of aluminium EN-AW 6060 T66. F2+ A B 90 Wall Bracket Throat depth A Distance to Wall B F2.50 50 mm 52 90 mm F2.80 80 mm 82 120 mm F2.115 115 mm 117 155 mm F2.150 150 mm 152 190 mm F2.185 185 mm 187 225 mm F2.220 220 mm 222 260 mm F2.255 255 mm 257 295 mm F2.290 290 mm 292 330 mm 175 4 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com

WALL BRACKET F3 The F3 wall bracket is used for vertical fixing systems from ceiling to ceiling. F3 A Technical Features and Benefits. High load carrying capacity due to overall height and 4 wall fixings per bracket for dowels or screws.. Large spans can be achieved due to a solid supporting beam recess.. Floor high supporting beams up to 3500 mm can be used.. Each F3 bracket is able to perform a fixed and sliding point function.. Made of aluminium EN-AW 6060 T66. F3+ A C Wall Bracket Throat depth A* Degree of opening C F3.80 80 mm 60 mm F3.135 135 mm 60 mm * other throat depths on request C WALL BRACKET F4 The F4 wall bracket is used mainly on solid walls for receiving aluminium supporting beams or wooden supporting laths. F4 A Technical Features and Benefits. Individual dimensions according to customer s requirements. Brackets are project related; defined by wall thickness and height, the fixings and dowel holes are variable according to static requirement calculations.. Construction allows for an additional supporting lath within the base of the bracket to cope with increased loads.. Made of aluminium ALMG 3. F4+ A C Wall Bracket Throat depth A* Degree of opening C F4 min. 35 mm min. 30 mm www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com 5 C

ALLFACE SYSTEM BASICS Basically, fixing systems are differentiated according to visible or concealed fastening and horizontal or vertical fixing. VERTICAL SYSTEMS Vertical systems are used for mounting on solid walls. The primary profile is mounted vertically on an F1. HORIZONTAL SYSTEMS For structures of beam and column construction, horizontal systems are used exclusively where the primary profile is mounted horizontally on an F2. SYSTEM F1, F2, F4 SYSTEM F3 Sliding point Sliding point Fixed point Fixed point Sliding point Sliding point Fixed point THERMAL LINEAR EXPANSION When mounting vertical or horizontal systems, temperature-related linear expansion of the profiles must be taken into consideration. For this reason, the elongated holes of the wall brackets allow for thermal expansion of the section. The length of the profiles is determined by the storey- height or panel separation. 6 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com

FIXED POINT The fixed point passes the dead weight and wind loads to the load-bearing wall. The connection between the wall bracket and profile is therefore Immobile when fixed though the round holes. For connections of primary profiles and carrier rails, fixed and sliding points are also used for fastening. SLIDING POINT In contrast, the connection between a sliding point and the profile is designed to be a sliding connection in elongated holes. As a result, the profile allows for thermal expansion and contraction with no jammed connections. For a sliding point, only wind pressure loads are passed to the load bearing wall. FIXED POINT SLIDING POINT THERMAL SEPARATION In order to avoid thermal bridges or alternatively to minimise heat losses, thermal separation elements are built in between the wall bracket and the outside wall. www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com 7

SMART FIXING SYSTEMS VISIBLE FIXING WITH RIVETS OR SCREWS Facade fastening with rivets is a very economical method of installation due to the easy mounting. It is mainly used for metal, fibre cement and High Pressure Laminate - HPL facade elements. SYSTEM F1.10 SYSTEM F2.10 8 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com

SYSTEM F3.10 SYSTEM F4.10 H www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com 9

VISIBLE FIXING WITH CLAMPS Fastening by means of clamps is used in particular for ceramic and terracotta facade elements. The clamps are available in aluminium and stainless steel and can be made to match the colour of the facade elements. SYSTEM F1.20 SYSTEM F2.20 10 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com

CONCEALED FIXING WITH ADHESIVE SYSTEM Glueing facade panels is an economical mounting method. The panels are assembled on the properly pre-treated profiles with permanent elastic glue and with double-sided adhesive mounting tapes. SYSTEM F1.30 SYSTEM F2.30 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com 11

CONCEALED FIXING WITH ADHESIVE SYSTEM Glueing facade panels is an economical mounting method. The panels are assembled on the properly pre-treated profiles with permanent elastic glue and with double-sided adhesive mounting tapes. SYSTEM F3.30 12 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com

CONCEALED FIXING WITH UNDER-CUT ANCHORS Facade panels can be fastened mechanically and concealed with the help of undercut anchors. Hanger elements are put into the undercut drill hole on the back of the panel with special dowels. Each facade panel is fastened with at least four individual hanger elements. SYSTEM F1.40 SYSTEM F3.40 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com 13

CONCEALED FIXING FOR HOOKING IN FACADE ELEMENTS Fixing systems for hooking in facade elements have proven to be an efficient mounting method. Aluminium Composite (ACM) boards are especially well suited for this mounting method. To do this, the ACM boards are processed into cassettes and hooked into the fixing system and then secured against slipping. SYSTEM F1.50 SYSTEM F2.50 14 www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com

MARK BUSSELL WORLDWIDE SUPPORT We simplify the complexity of facade design. The determination of the optimal fixing solution based on your detailed project information is done by us. With our statics calculation programme, we comply with all required safety requirements and optimise the quantity of fixing elements that are used. This is a major contribution to the economic efficiency of the project. Starting with the static calculations of the project, the installation plans are prepared for clear understanding and clarity, assisting in fast and easy installing. By maintaining an open dialogue with our customers, we are able at the planning stage to point out difficulties and issues; providing solutions and possible improvements. Thus helping to save costs. To help prepare your plans, we would be happy to provide CAD drawings with system details. In addition, we will give you the appropriate templates for the specification. We advise facade manufacturers and architects with regard to general and specific topics of Rainscreen. Importantly we also provide onsite training and support to the customer and installation teams. The Allface Smart Fixing Systems contact with the customer is achieved through our international sales network. Customers benefit from our commitment to high standards of quality and service at all times. Project Information Form To prepare a meaningful offer, we need you to fill out the project information form. (See the project information form at www.plastestrip.com) Guarantee All systems are manufactured in accordance with EN 12020 and EN 755 and are statically provable. Allface is not liable for deficiencies in the facade elements or the installation. Local building regulations must be met. Subject to technical changes. Allface 2010 Graphics: WERK1 Version: 12/10 en www.plastestrip.com T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com 15

From Plastestrip Profi les 1-4 Enterprise Park St Austell, Cornwall, UK, PL25 4EJ T +44(0)1726 74771 F +44(0)1726 69238 sales@plastestrip.com www.plastestrip.com