Increasing Sensitivity In LC-MS. Simplification and prefractionation of complex protein samples

Similar documents
Faster, easier, flexible proteomics solutions

Agilent Human 14 Multiple Affinity Removal System Spin Cartridges for the Depletion of High-Abundant Proteins from Human Proteomic Samples

Discover New Proteins Using Immunodepletion

Agilent Multiple Affinity Removal Spin Cartridges for the Depletion of High-Abundant Proteins from Human Proteomic Samples.

Agilent 3100 OFFGEL Fractionator pi-based fractionation of proteins and peptides with liquid-phase recovery

Proteome Profiling by Multidimensional Protein Separation and Automated Lab-on-a-Chip Technology Application

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

Comparative Analysis of Serum Samples with the Agilent mrp-c18 Column - A New Technology for Protein Fractionation Application

Agilent AssayMAP Bravo Platform AUTOMATED PROTEIN AND PEPTIDE SAMPLE PREPARATION FOR MASS SPEC ANALYSIS

Alternative to 2D gel electrophoresis OFFGEL electrophoresis combined with high-sensitivity on-chip protein detection.

Accelerate mab Characterization Using Automated Sample Prep

New Sample Fractionation Strategies for Proteomic Analyses by LC MS

Protein Microarrays?

Agilent AssayMAP Platform BIOLOGICS SAMPLE PREPARATION INTELLIGENTLY AUTOMATED

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

Vivapure Anti-HSA/IgG Kits for Human Albumin and Human Albumin/IgG Depletion

Removal of Multiple High-Abundant Proteins from Mouse Plasma Using the Agilent Multiple Affinity Removal System for Mouse Application

Identification of human serum proteins detectable after Albumin removal with Vivapure Anti-HSA Kit

Jet Stream Proteomics for Sensitive and Robust Standard Flow LC/MS

Introducing Agilent s Next Generation Capillary Electrophoresis System

Peptide enrichment and fractionation

Background - Importance of monoclonal antibody characterization

Agilent 6430 Triple Quadrupole LC/MS System

ProteoMiner Protein Enrichment Technology

Reducing dynamic range with Proteominer

Conventional isoelectric focusing with the Agilent 3100 OFFGEL Fractionator

CaptiveSpray nanobooster

Increasing MS Sensitivity for Proteomics

AssayMAP. Mitu Chaudhary Product Marketing Manager Bay area product specialist Robert (Bob) Boice

Agilent 6000 Series LC/MS Solutions. Confidence in Quantitative and Qualitative Analysis

A Protein Expression analysis of Healthy and Diseased Patient Amniotic Fluid Samples Using ProteomeLab PF 2D: A Case Study on Sample Processing.

Agilent CE and CE/MS Solutions FLEXIBILITY AND RELIABILITY TO AMPLIFY YOUR FINDINGS

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

UVic-Genome BC Proteomics Centre

Proteome Purify TM 12

Table 1: CE-MS: Unexploited Opportunities in Process Development?

DISCOVERY AND VALIDATION OF TARGETS AND BIOMARKERS BY MASS SPECTROMETRY-BASED PROTEOMICS. September, 2011

FOR RESEARCH USE ONLY. NOT FOR HUMAN OR DIAGNOSTIC USE.

Clearly better LC/MS solutions

The Perfinity Workstation: Achieving Quality Through Automation

Sample Preparation Automation and QQQ Workflows for Peptide Quantitation in DMPK

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

Agilent solutions for contract research and manufacturing organizations

Jet Steam Proteomics with Automated Sample Prep for Superior Peptide Quantitation

Unified Workflow for Monoclonal Antibody Charge Heterogeneity, Purity, and Molecular Weight Analysis

Solutions Guide. MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore India

Improving the Detection Limits for Highly Basic Neuropeptides Using CESI-MS

columns PepSwift and ProSwift Capillary Monolithic Reversed-Phase Columns

NanoLC-Ultra system. data sheet. Introducing the NanoLC-Ultra family of high pressure HPLCs for proteomics research

Hichrom Limited 1 The Markham Centre, Station Road, Theale, Reading, Berkshire, RG7 4PE, UK Tel: +44 (0) Fax: +44 (0)

LECTURE 8. Biologics and Future Technologies for the Clinical Laboratory

Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC

12/6/12. Dr. Sanjeeva Srivastava IIT Bombay

S R E VA V Blu l e P ep Kit i s SERVA Blue Prep CBD Micro/MacroKit SERVA Blue Prep DetergentEx Micro/Macro Kit SERVA Blue

Development and evaluation of Nano-ESI coupled to a triple quadrupole mass spectrometer for quantitative proteomics research

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

A Rapid and Reproducible Immuno-MS Platform from Sample Collection to Quantitation of IgG

Mass Spectrometry and Proteomics - Lecture 6 - Matthias Trost Newcastle University

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

Proteomics Background and clinical utility

Simplifying ImmunoAffinity Capture Workflow

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

MassPREP On-Line Desalting Cartridge

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Ab SpinTrap Ab Buffer Kit

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Agilent 3100 OFFGEL Fractionator Kit

Pharmaceutical LC/MS Solutions from Agilent Technologies

Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

sample preparation Accessing Low-Abundance Proteins in Serum and Plasma With a Novel, Simple Enrichment and Depletion Method tech note 5632

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

GELFREE 8100 Fractionation System. Frequently Asked Questions

Universal Solution for Monoclonal Antibody Quantification in Biological Fluids Using Trap-Elute MicroLC-MS Method

Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

Ultra-Sensitive Quantification of Trastuzumab Emtansine in Mouse Plasma using Trap-Elute MicroLC MS Method

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

Zakopane, April, 2011

ExoMS Total Protein Capture Kit

ProteoEnrich CAT-X SEC Kit Merck: Lichrospher Composition. Silica Particle size. 25 µm particles with 6 nm pore size Ligand SO 3

Mass Spectrometry Analysis of Liquid Chromatography Fractions using Ettan LC MS System

Tools and considerations to increase resolution of complex proteome samples by two-dimensional offline LC/MS. Application

Application Manual ProteoSpin Abundant Serum Protein Depletion Kit

Application Note. Comparison of HPLC-Chip/MS with conventional nanoflow LC/MS for proteomic analyses

Optimization of Protein Purification Using Small-Scale Separation Columns

Protein Purification Products. Complete Solutions for All of Your Protein Purification Applications

Proteomics and some of its Mass Spectrometric Applications

sample preparation Accessing Low-Abundance Proteins in Serum and Plasma With a Novel, Simple Enrichment and Depletion Method tech note 5632

More Capabilities, New Possibilities in Mass Spectrometry

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

Strategies in proteomics

Bioanalyzer and Tapestation Summit

Lecture 8: Affinity Chromatography-III

Application Note 18 RNA/DNA/Protein Sample Preparation METHODS AND MATERIALS INTRODUCTION

New techniques for extraction, separation, and detection of EPO Dr. Zhen Liu

Application Note. Authors. Abstract

A High Throughput Microchromatography Platform

Transcription:

Increasing Sensitivity In LC-MS Simplification and prefractionation of complex protein samples

Protein Analysis Workflow Simplify Fractionate Separate Identify High Abundant Protein Removal reduction of complexity, enrichment pi-based fractionation Fractionation, desalting Multiple Affinity Removal OFFGEL mrp LC MS Data Quality Control CE Bioanalyzer

Sample Preparation For Biofluids MARS A polyclonal antibody based system to rapidly deplete multiple high abundant proteins in serum/plasma/csf. H H L H L L Launched in August 2003 H L L H Individual Ab materials are mixed in selected HL H H L H percentages and packed into a column format Agilent continues to innovate and lead this market Apply Crude Human Serum HH H H HH H H Unbound Fraction (low abundance proteins) Bound Fraction (high abundance proteins) Total Run Time (30 min) Buffer A Buffer B L L L L L L H H H H HH H H Low-Abundance Proteins Free from Interferences High-Abundance Proteins

Multiple Affinity Removal System Columns & spin cartridges Removes top 6, 7 or 14 high abundant proteins (HAP) from serum/plasma etc. at 95-99% levels each Depletes HAP found in serum/plasma, urine, BALF, CSF, tissue and other biological samples Removal of HAP has the benefit of: Unmasking the low abundant proteins (LAP) of interest e.g. potential biomarker, Increasing dynamic range of the analysis Page 4 July 23, 2009

MARS Column Configurations Hu-6 + Hu-6C / Hu-7 / Hu-14 Ms-3 Two new configurations available soon: HSA & HSA/IgG Anti Albumin Anti IgG Anti Transferrin and the same configurations in spin cartridge format

Multiple Affinity Removal System 14 MARS Anti HSA Anti IgG Anti Transferrin Anti Haptoglobin Anti Alpha1-antitrypsin Anti IgA Anti Fibrinogen Anti Alpha2-Macroglobulin Anti Alpha1-Acid Glycoprotein Anti IgM Anti Apolipoprotein AI Anti Apolipoprotein AII Anti Complement C3 Anti Transthyretin Removes 92-94% of total protein Proteomic Sample High Abundance Protein Low Abundance Protein Proteomic Sample with Low Abundance Proteins In Column Flow-through

mrp-c18 Protein Fractionation Column mrp mrp (macroporous reverse-phase) What is it? Reverse Phase column for protein separation and fractionation. The silica based particles and recommended LC methods have been optimized for: Highest recoveries of protein samples (95% - 99% of loaded sample) Highest resolution separations Reproducibility High sample loading capacity (3X higher than most standard RP columns) Lifetime Can be used for desalting with quick gradient

mrp-c18 Recovery using Serum mrp Immunodepleted serum Blank Protein Conc. Protein Conc. Protein Conc. % recovery Pre-mRP* No column mrp recovery 47 49.8 g 49.3 g 99%

NEW Complex Proteomics Standard Proteins extracted from genetically distant archaeon Pyrococcus furiosus Complex sample for evaluation of LC/MS protein identification workflow Over 1500 proteins, spanning wide ranges of size, pi and hydrophobicity For benchmarking and validation of proteomic workflow s over time, across instruments, methods or labs

OFFGEL Fractionation OFFGEL separates proteins or peptides by pi based on the resolving power of immobilized phgradient (IPG) gels provides analytes in solution compatible with LC-MS and upfront sample preparation techniques Low ph Low ph High ph High ph Low ph High ph

3100 Features OFFGEL Protein/peptide fractionation with 0.1 0.6 pi resolution µg to mg load capacity (50 g 5 mg per sample) Possible to run conventional in-gel IEF as well as OFFGEL fractionation Diagnostics: Online current control for each individual sample allow to check fractionation quality & progress of each individual sample

Protein or Peptide Fractionation Protein-based OFFGEL Peptide-based 4-fold increase of detected proteins due to OFFGEL fractionation

OFFGEL Protein Fractionation 4 times better sensitivity with OFFGEL E.coli lysate OFFGEL ph 4-7, 24 fractions digest HPLC/MS

OFFGEL Combination of IEF with SDS-PAGE Visualizing protein expression differences in complex samples Bioanalyzer New without OFFGEL

Sensitivity: Silver Staining vs. Bioanalyzer OFFGEL Bioanalyzer Size / kda 250 95 48 24 12 6.0 3.0 1.5 0.7 Size / kda 250 59 29 15 7.3 3.7 1.8 0.9 0.5 ng of total protein loaded per gel lane or chip well 150 100 70 150 50 100 30 70 50 15 30 15 Silver stained PA-gel (4-12% BisTris minigel) LM 2100 Pseudo gel view

Why Use Microfluidics For Nanospray LC/MS? Integrate functional components onto a reusable, biocompatible chip enrichment and analytical nanocolumns nanospray emitter fittings and connection capillaries directly on a reusable biocompatible polymer chip.

HPLC-Chip Microfluidics Technology High Performance Nano-separations made Routine Fluidic, Sample Ports Enrichment Column Analytical Column 75 x 50 µm cross section C18, C8 NEW 300A, 80A NEW Laser Ablated ESI Tip

Chip Technology for Proteomics & Biomarker Discovery/Validation AVAILABLE NOW! Protein ID Chips GPC Chip Intact Protein Chip Infusion Chip Calibration Chip Custom Chip High Capacity Chip Intact Protein Analysis Quantitative Proteomics Peptide/protein digests Biomarker Discovery Phosphopeptide Chip COMING SOON! GlycoPro Chip Glycoprotein Analysis Phosphoprotein Analysis

Agilent 7100 Capillary Electrophoresis System Agilent Technologies introduces the Next Generation Capillary Electrophoresis System

Capillary Electrophoresis at Agilent Former G1600 HP 3 D-system Agilent has more than 15 years of CE experience and CE is one of Agilent s core technologies (4000 systems installed) Agilent pioneered the proprietary bubble cell capillaries & high sensitivity cell providing highest CE sensitivity levels in UV detection

Agilent 7100 Capillary Electrophoresis System Evolution of the proven 1600 CE Technology Unprecedented sensitivity and handling New! Backward-compatible with previous generation Sample throughput with Agilent Replenishment-system Fully flexible on detectors (DAD-UV, MS, LIF, CCD,..) Agilent ChemStation control and data analysis

Agilent 7100 Capillary Electrophoresis System Using External Detectors Agilent s CE-ESI-MS systems provide Single vendor solution: Plug and spray Full portfolio, MSD, Triple-Quad, ToF, Q-ToF Most robust and reliable ESI-Interface for CE Capillary exit on ground no compromises!

Agilent 7100 Capillary Electrophoresis The CE-MS advantage CE-Electrospray is a powerful method for high resolution separation and identification for a wide variety of molecules. Additionally it is an orthogonal separation technique to HPLC The Agilent interface combines the advantage of a grounded CE capillary end with a robust and easy to use spray needle that fits into the whole portfolio of Agilent MS instruments Widest choice of detctors DAD, LIF, CCD, Single-Q, IT, ToF, QQQ, QToF, ICP-MS Only vendor for plug & spray ESI-MS complete CE-MS portfolio with a single interface solution Easy change from LC-MS to CE-MS and back quick and robust ESI by MS-adaptor & spray needle kit using Agilent Chemstation software Combined detection option UV-DAD plus MS detection, LIF plus MS detection Grounded CE capillary end No compromises between separation- or ESI-spray voltage

Summary: Use in Protein Biomarker Applications Sample Prep Simplify/Deplete Extraction of unique proteins from samples and simplify sample for analysis Extract protein from tissue or blood with FFPE Protein Extraction Solution or PPS Silent Surfactant Blood serum/plasma samples (or CSF, urine) deplete highabundant proteins with Multiple Affinity Removal System Fractionate Separate/LC Prep Identify Reduction of complexity and enrichment Quality Control 2100 Bioanalyzer Fractionate, concentrate, and desalt proteins with mrp-c18 3100 OFFGEL Digest with Proteomics Grade Trypsin Agilent 1200 Series Liquid Chromatography New Complex Proteomics Standard Agilent 6000 Series Mass Spectrometry w/ HPLC-Chip Agilent Restricted

Summary Sensitivity and reproducibility can be greatly enhanced by sample prefractionation Immunodepletion, reverse phase and pi-based fractionation can be employed as tools for reducing sample complexity Agilent s prefractionation tools are compatible and can be used in various combinations and sequences For more information visit www.agilent.com/chem/