Toronto GREEN Development Standard Checklist [for Low-Rise Residences]

Similar documents
TORONTO GREEN STANDARD VERSION 2.0

TORONTO GREEN STANDARD v3

Taylor Institute. LEED Certification : GOLD

2011 Enterprise Green Communities Criteria Checklist

HUGH GARNER ENVIRONMENTAL POLICY

GLADYS VALLEY HALL. Materials & Resources Innovation & Design Process

Urban Revitalization Plan For Responsible and Sustainable Growth and Development City of Adel, Iowa

Project location includes access to existing roads, existing water and wastewater infrastructure, and within or contiguous to existing development.

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Phillips Exeter Academy


Analysis 1. LEED Analysis of Laboratory Buildings. Penn State School of Forest Resources University Park, PA

NPS Project Sustainability Checklist Building Projects (For New Construction or Major Renovation)

TORONTO GREEN STANDARD v3

FEBRUARY 22, GREEN BUILDING: Past, Present and Future

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction

TORONTO GREEN STANDARD v3

The Road Home Small Rental Property Program Guide to Green Building Standards

Tier 2 Tier 3 Tier 4

Green Points Worksheet

Introduction to Integrated Sustainable Design

L E E D S C O R E C A R D ( B U I L D I N G D E S I G N & C O N S T R U C T I O N )

Appendix B. Certification of Intent to Comply

UBC Residential Environmental Assessment Program

LEED Project Delivery Process Manual Appendices

The Application of LEED Green Building Rating System in Indonesia

ENERGY AND ENVIRONMENT DESIGN AND CONSTRUCTION STANDARDS ENERGY AND ENVIRONMENT

Note year for Reference as Specified in the LEED V Manual.

Appendix C APPLICATION #: ADDRESS: CITY OF SANTA CRUZ GREEN BUILDING PROGRAM GREEN POINTS CHECK LIST FOR NON-RESIDENTIAL BUILDINGS

Chapter Four: Green Remodeling Illustrations

LEED 2009 for New Construction and Major Renovations

2012 Green Homes Tour

- AIA Honor Award for Interior Architecture - ALA/IIDA Library Interior Design Awards: Best

burnsville green guide green remodeling strategies to save you money while improving your health and reducing the environmental impacts of your home

BUILDING FOR OUR FUTURE

CITY COUNCIL AGENDA REPORT

MSHDA Affordable Green Enterprise Green Communities USGBC LEED

Introduction to Integrated Sustainable Design

Leased Space Environmental and Energy Efficiency Attributes Tenant Instructions

GREEN BUILDING REQUIREMENTS

Mecklenburg County Sustainable Facilities and Development Policy

Green Charrette BANCROFT ELEMENTARY SCHOOL GREEN CHARRETTE

FOR ADDITIONS and REMODELS Before filling out this application, read Green Building & Green Points Guideline Booklet for more in-depth information.

Overview of Green Home

Certified 55 to 65 Points, Silver 66 to 76 Points, Gold 77 to 87 Points, Platinum 88 to 110 Points

Projected actual points. Responsible for UNC -- Project name. Remarks

Understanding the 2010 California Green Building Standards Code

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3

ADEC S SUSTAINABLE FUTURE SCHOOLS PROGRAM

ASC New Building 400 Masthead Street Albuquerque, NM

Construction & Energy Management: Sustainable Construction Practices. Cabrillo College- CEM 162 Spring Quarter 2010

Planning Rationale. A) Family Oriented Development

THE CORPORATION OF THE CITY OF PENTICTON DEVELOPMENT COST CHARGES REDUCTION BYLAW NO

CONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability

Environmental & Sustainability Policy Statement

LEED-CI ANALYSIS 140 GRAND STREET WHITE PLAINS, NY

Answers. LEED for Neighborhood Development (LEED ND) Quiz #4 Green Infrastructure and Buildings (GIB)

TOWN OF COCHRANE POLICY

Existing vegetation with each tree detail like species, girth, canopy etc. Contours with levels Natural features like water body, stream etc.

Allowance Table for: General:

Rosslyn Sector Plan Status Update. Environment and Energy Conservation Commission Meeting May 18, 2015

ENERGY EFFICIENCY AND SUSTAINABILITY PLAN FOSTER CREEK WEST NEIGHBOURHOOD NEWCASTLE MUNICIPALITY OF CLARINGTON

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

Colorado Mountain College: Sustainable Design Standards

LEED & INCENTIVES. Alison Y. Rivenburgh, LEED AP

WINDMILL DEVELOPMENT GROUP

5 Cowperthwaite Street Harvard Real Estate Services LEED-NC GOLD, August 2007

LEED for Homes Project Checklist

California HERO Program Residential Eligible Product List All Products

Project Summary. Sustainability Facts. LEED for New Construction Rating (out of 69 possible points) Total Score 40 Sustainable Sites 7

1st Floor. The Hunt Library Sustainability Tour

Environmental Principles

Green Smart. BUILDING Building SITE/LANDSCAPE ENERGY WATER INDOOR AIR QUALITY MATERIALS

Decatur Fire Station No. 2

Sustainable Design A DIVISION OF SHIVE-HATTERY

LEED 2009 for Commercial Interiors. Presented by: Colleen McCafferty LEED AP Roselia Harris LEED AP

Green Building Ordinance Overview

Special Mention, Architecture + Sustainability

Toyota Logistics Service. Portland Vehicle Distribution Center Redevelopment

LEED-CI ANALYSIS 1 LANDMARK SQUARE STAMFORD, CT

Culver City Building Safety Division Mandatory Green Building Program

IGBC certification in multi dwelling residential developments S I M P L I F I E D. Arpan Johari Principal architect AW design.

SUSTAINABLE DEVELOPMENT

LEED Application Guide for Multiple Buildings and On Campus Building Projects

REAP 3.0. Project Information

Jersey City Public Safety Communications Center

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Sustainable Residential Policies Mayfield West Phase Two

WEST WINDSOR TOWNSHIP GREEN DEVELOPMENT PRACTICES CHECKLIST

CALGreen Mandatory Regulatory Provisions and Synergies with LEED. Antea USA, Inc.

Design Standard Sustainability

37% 100% 100% PROJECT HIGHLIGHTS LEED Facts. Wiener Auditorium

LEED v4 ATAS Reference Guide

Single Family Homes less than 3,000 sq.ft.

GUIDELINES ON ENERGY CONSERVATION IN SEZs

LEED New Construction v.2.2 semi BLANK Study Guide Credit Number Credit Name Intent and Implementation Code or Standards Extra Credit Sub.

4043 N. Ravenswood Suite 207 Chicago, IL

2012 USGBC Central Florida Chapter LEEDership Awards Outstanding Green Building of the Year: Valencia College, Lake Nona Campus Valencia College s

Transcription:

the Toronto GREEN Development Standard Checklist [for Low-Rise Residences] Purpose The Checklist is a tool to aid developers in tracking their intended implementation of the Standard for any given project, identifying both green performance targets and submittal materials that can demonstrate implementation. It is also a tool to aid City staff in tracking the implementation of the Standard throughout Toronto. How to Use It The Checklist should be provided to developers by City Planning staff at the earliest possible stage of the development process, ideally during pre-application consultation. The Checklist follows the same structure as the Green Development Standard, with development features categorized according to environmental drivers (including AIR, ENERGY, WATER, etc.). It should be used in conjunction with the full Green Development Standard document (available at: www.toronto.ca/planning/greendevelopment.htm), which has a more complete description of each development feature and potential implementation strategies. In the first column, the symbol indicates a minimum requirement under the Green Development Standard. Features without this symbol are additional options that would further improve a development s environmental performance. The second column indicates which submittal materials can be used to show implementation. For some development features, this column is blank because there are currently no required submittals where implementation could be demonstrated. Work is currently underway to determine how implementation of these features could be indicated in the future. How to Submit It Developers should return a completed copy of the checklist with their development application, whether or not they will meet the Green Development Standard. The completion of the Checklist is equally valuable for developments that do not meet the Green Development Standard, since it will help staff to track the implementation of the various features within the Standard. Developers should be requested to also keep a copy of the Checklist and to revise it if their development plans change. Contact for More Information: sustainablecity@toronto.ca, 416.392.0191 1

Green Development Standard Checklist: PROJECT INFORMATION Approval Process Official Plan Amendment Zoning Bylaw Amendment Site Plan Approval Draft Plan of Subdivision Office Use Only: Date Received: Staff Contact: IBMS # Property and Applicant Property Address (Street Number / Name) or Location Registered Property Owner Applicant Name Contact Information Project Description (including any third party green certification being pursued, such as LEED, R-2000 or Energy Star) 2

Green Development Standard Checklist: AIR Local Materials Minimum: 10% of materials (based on value) harvested, manufactured and supplied within 800 km of project. Preferred: 20% of materials (based on value) harvested, manufactured and supplied within 800 km of project. Pedestrian Infrastructure Appropriate grading and surface treatment, in accordance with the Toronto Accessibility Design Guidelines and the Draft Toronto Streetscape Manual, as applicable. Construction Activity Methods identified for minimizing air emissions and dust during construction and demolition. Methods identified for minimizing VOC emissions during construction and demolition. Ozone Protection Zero use of CFC-based refrigerants and Halons in fire suppression Urban Heat Island Reduction: At Grade One of the following provided: Cover provided to shade at least 30% of all hardscape, including surface parking, walkways and others Light coloured materials* for at least 50% of all hardscape, including surface parking, walkways and others Combination of shading and light coloured materials* for at least 50% of all hardscape, including surface parking, walkways and others. * Light coloured materials must have a reflectance of 0.3 Urban Heat Island: Roof One of the following provided: Green roof installed with 50% minimum roof coverage Light coloured roofing materials* used for 75% of the roof Combination of green roof and light coloured roofing materials* for at least 75% of the roof. Green roof designed to meet the City s performance criteria (minimum of 6 inch depth, non-monoculture) * Light coloured roofing materials must have Surface Reflectivity Index greater than 78 and emissivity greater than 0.9 according to ASTM Standard 408. Site and Landscape Plan Landscape Plan Sun / Shadow Study (where Arborist Report Tree Preservation Plan Roof Plan (where 3

Green Development Standard Checklist: AIR Indoor Air Quality 45% of materials, including adhesives, sealants, paints, coatings, carpets, composite wood and agrifiber products, are low-emitting. Preferred: 75% of materials are low-emitting Excellent: 90% of materials are low-emitting Proper ventilation provided to control fungus, mold and bacteria. Principle Venting Capacity (PVC) = 15 cubic feet per minute times the number of bedrooms + 1 Forced air distribution required to be interconnected with operation of PVC fan. 4

Green Development Standard Checklist: ENERGY Insulation Walls, floor and ceiling insulated to the following Energuide standards: Ceiling w/ attic: R40, Ceiling without attic: R31 Exterior walls: R19+5 Basement walls: full height, R+10/R13 Exposed floors: R31 Slab w/o infloor heating: If >2ft below grade: uninsulated If <2ft BG: R+10, edge Air tightness / Air Leakage Air leakage at doors and windows reduced to less than 2.0 in2/100ft. Windows and Doors Ducts Energy Star certified windows installed Ductwork sealed in basement, and ducts located in heated boundary Space Heating and Cooling Energy Star heating and air conditioning system installed Water Heating High efficiency boiler OR tankless water heater installed, complying with Canada s energy efficiency regulations. Light Fixtures and Home Appliances All fixtures are Energy Star compliant. Where new appliances are being supplied, all are Energy Star compliant. Green Energy On-site renewable energy to self-supply 5% -10% of project s energy needs. 25% of energy needs purchased through grid-source renewable energy. Daylighting / Building Orientation Building oriented and designed to take advantage of passive solar heating. Building oriented and designed to take advantage of natural lighting Elevation Drawings Floor Plans 5

Green Development Standard Checklist: WATER Construction Activity Greater Toronto Area Conservation Authorities on-site Erosion and Sediment Control Guidelines adhered to during construction and demolition activities. Stormwater Run-Off: Suspended Solids Removal On an annual loading basis, 80% of total suspended solids removed from all runoff leaving the site. Stormwater Run-Off: Disinfection Runoff from the site that discharges directly into Lake Ontario or Waterfront areas disinfected. Stormwater Run-Off: Erosion Control Greater Toronto Area Conservation Authorities on-site Erosion and Sediment Control Guidelines adhered to for individual sites which discharge directly or are in close proximity to natural watercourses Stormwater Retention / Water balance Stormwater on-site retained to the same level of annual volume of overland runoff allowable under predevelopment conditions All runoff retained on the site from small design rainfall events (typically 5 mm) Sediment and Erosion Control Plan (where Sediment and Erosion Control Plan (where Sediment and Erosion Control Plan (where Sediment and Erosion Control Plan (where 6

Green Development Standard Checklist: WATER Low-Water Landscaping Drought-resistant plant materials used. Rain Water Harvesting At least 50% of rainwater collected, treated (if necessary), and used for flushing toilets and/or irrigation. Grey Water Re-use Grey water from laundry and/or bathing collected, treated, and used for flushing toilets/urinals, irrigation, or other appropriate uses. Landscape Plan Stormwater Management Plan High Efficiency Fixtures and Appliances All water fixtures meet efficiency standards toilets: 6.0 L/flush; urinals: 3.8L/flush; faucets: 9.5L/min. Where provided, all appliances meet efficiency standards dishwashers: 38L; washing machines use 40% less water. Individual faucet metering (0.95 L / cy) provided. 7

Green Development Standard Checklist: SOLID WASTE Construction Waste Management Maximum of 2.5 Lbs /sq foot of construction waste sent to landfill Reuse of Building Materials Preferred: At least 5% of project s materials (based on value) are reused materials. Excellent: 10% or more of project s materials (based on value) are reused materials. Use of Recycled Materials Preferred: At least 7.5% of a project s materials (based on value) are comprised of recycled content** Excellent: 15% recycled content* *Recycled content defined by CAN/CSA-ISO 14021-00 Environmental Labeling and Advertising Guidelines Durable Buildings Compliance to CSA S478-95 (R2001) guideline for durable buildings 8

Green Development Standard Checklist: ECOLOGY Urban Forest: Site and Adjacent Boulevard All trees that are 30cm or more DBH (diameter at breast height) retained. Each tree provided with a minimum soil volume of 15 m 3 of high quality soil. Minimum protection distances and standards for tree protection barriers during construction have been adhered to according to Specifications for Construction Near Trees Native soil retained on site (or replaced, as necessary, with local soil of equal or better quality). Non-potable watering system for all trees provided Large growing, predominantly native shade trees planted to achieve 40% canopy coverage of the site at maturity Natural Heritage: Site No invasive species planted on properties or streets adjacent to ravines and natural area parks. Preferred: Native trees, shrubs and ground cover planted on 50% of site area (excluding building footprint) Excellent: Native trees, shrubs and ground cover planted on 75% of site area (excluding building footprint) Glass and other design features for Migratory Birds For homes adjacent to ravines and natural areas, Bird Friendly Development Guidelines adhered to Light Pollution No lighting directed towards the sky Bird friendly Development Guidelines adhered to Landscape Plan Arborist Report Tree Preservation Plan Natural Heritage Impact Study (where Landscape Plan Arborist Report Tree Preservation Plan Natural Heritage Impact Study (where Elevation Drawings Perspective Drawings Natural Heritage Impact Statement (where Heritage Impact Statement (where Plan for Public Art (where Landscape Plan Elevation Drawings Floor Plans 9

City of Toronto Policies, Programs and Guidelines Toronto Official Plan: www.toronto.ca/planning/official_plan/introduction.htm Environmental Plan: www.toronto.ca/environment/plan_update.htm Toronto Building Permits: www.toronto.ca/building/building_permits.htm Climate Change and Air Quality Strategy: www.toronto.ca/changeisintheair/ Water Quality (Wet Weather Flow Management Guidelines): www.toronto.ca/water/publications/index.htm Water Efficiency Plan: www.toronto.ca/watereff/plan.htm Energy Plan: www.toronto.ca/energy/plan.htm Solid Waste Management: www.toronto.ca/garbage/ Urban Design Guidelines: www.toronto.ca/planning/urbdesign/guidelines.htm Accessibility Guidelines: www.toronto.ca/diversity/pdf/accessibility_design_guidelines.pdf Green Roof Policies, Performance Criteria and Incentives: www.toronto.ca/greenroofs Urban Forestry Policies: www.toronto.ca/trees/bylaws_policies.htm Tree planting: www.toronto.ca/trees/tree_planting.htm Bird Friendly Development Guidelines: www.toronto.ca/lightsout/guidelines.htm Energy Efficiency - Better Buildings Program: www.toronto.ca/energy/index.htm Water Efficient Fixtures and Appliances: www.toronto.ca/watereff/index.htm Rainwater Harvesting (downspout disconnection for low-rises): www.toronto.ca/water/protecting_quality/downspout.htm Air Quality and Energy Efficiency for low-rise residences: www.toronto.ca/health/2020/2020_connector_home.htm Toronto Atmospheric Fund: www.toronto.ca/taf/ External References LEED (Leadership in Energy and Environmental Design, Canada Green Building Council): www.cagbc.org Green Globes: www.greenglobes.com Model National Energy Code: www.nationalcodes.ca/mnecb/index_e.shtml Toronto & Region Conservation Authority (Erosion Control Guidelines): www.trca.ca American Society for the Testing of Materials (ASTM): www.astm.org American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE): www.ashrae.org Illuminating Engineering Society of North America (IESNA): www.iesna.org/ Energy Star Canada: oee.nrcan.gc.ca/energystar/english/consumers/index.cfm Canadian Standards Association (CSA): www.csa.ca Canadian Institute of Transportation Engineers (CITE): www.cite7.org/technical_projects/sitedesignreview.htm R-2000: r2000.chba.ca/ 10