SECTION GLASS-FIBER-REINFORCED PRECAST CONCRETE

Similar documents
SECTION COLD-FORMED METAL TRUSSES

SECTION ARCHITECTURAL PRECAST CONCRETE. A. American Society for Testing and Materials (ASTM):

***************************************************************************************************************

A. Product Data: For each type of cold-formed steel framing product and accessory.

SECTION ARCHITECTURAL PRECAST CONCRETE. C. Section Joint Sealers: Perimeter joints with sealant and backing.

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

SECTION COLD-FORMED METAL FRAMING

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

SECTION COLD-FORMED METAL FRAMING

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. A. Section Cast-In-Place Concrete: Concrete, reinforcing, anchors, etc.

SPECIAL SPECIFICATION 2043 Brick Veneer on MSE Wall

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION AWNINGS

SECTION COLD-FORMED METAL FRAMING

Design Reference Sample: Sample of approved precast structural concrete color, finish, and texture, preapproved by Architect.

Master Specifications for Microcotta November 2017

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS

STRUCTURAL STEEL FRAMING

SECTION STRUCTURAL STEEL

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Corium Brick Rainscreen System Specifications

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

HARVEY MUDD COLLEGE TEACHING AND LEARNING CENTER SECTION Page 1 of 6 VOIDED CONCRETE SLAB

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION EPOXY TERRAZZO

GUIDE SPECIFICATIONS For STRUCTURAL PRECAST HOLLOW CORE SLABS SECTION 03410

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

ThermalShell Modular Insulated Pre-Cast Panels

SECTION PRECAST CONCRETE COVER SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

SECTION (10705) EXTERIOR SUN CONTROL DEVICES

Student Services & Classroom Addition

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING

SECTION UNIT MASONRY

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION METAL STAIRS

SECTION STRUCTURAL STEEL

Mezzanines By Design Page 1

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

SECTION PRECAST STRUCTURAL PRETENSIONED CONCRETE

SECTION COLD-FORMED METAL FRAMING

Attachment A-Flagpole(s) Specifications

SECTION (05400) - COLD-FORMED METAL FRAMING

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

TerraClad TM General Specifications

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

Preassembled steel stairs with concrete-filled treads.


SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION GLASS UNIT MASONRY ASSEMBLIES

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

STRUCTURAL PRECAST CONCRETE

1. Cast-in place structural concrete including footers, foundations, and other non-slab applications. 2. Formwork 3. Reinforcement

Specifying Pre-Engineered CFS Floor and Roof Trusses 551f-98

Bus Facility

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION COMPOSITE METAL DECKING

SECTION METAL FLOOR PLATE STAIRS

STRUCTURAL STEEL FRAMING Section

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

B. Shop Drawings: Include plans, elevations, sections, details, and attachments.

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

SECTION METAL STAIRS

***************************************************************************************************************

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

1. High bay shelving units, fabrication and installation including leveling.

Endicott Mbrick Thinbrick Color Burgundy Sands

Endicott Mbrick Thinbrick Color Red Blend Velour

SECTION STRUCTURAL REINFORCED POLYMER COMPOSITE PEDESTRIAN BRIDGE DECK

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION EXPANSION CONTROL

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION EXPANSION CONTROL

SECTION COLD-FORMED METAL FRAMING

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

Transcription:

SECTION 03490 GLASS-FIBER-REINFORCED PRECAST CONCRETE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes plant-precast glass-fiber-reinforced concrete for decorative elements indicated. 1.3 DEFINITIONS A. GFRC: Glass-fiber-reinforced concrete. 1.4 PERFORMANCE REQUIREMENTS A. Structural Performance: Provide GFRC members capable of withstanding gravity, wind, seismic, and erection design loads as well as the effects of thermal- and moisture-induced volume changes, according to load factors and combinations established in PCI MNL 128, "Recommended Practice for Glass Fiber Reinforced Concrete Panel." 1. Design Loads: As indicated. 2. Design framing systems to withstand design loads with lateral deflections no greater than 1/240 of the wall height. B. Design members to provide for movement without damage or overstressing, connection failure, undue strain on fasteners and anchors, or other detrimental effects when subject to a maximum ambient temperature change of 100 deg F(56 deg C). 1.5 SUBMITTALS A. Product Data: For each type of product indicated. Include GFRC design mixes. B. Shop Drawings: Detail fabrication and installation of GFRC panels, including the following: 1. Comprehensive engineering analysis signed and sealed by the qualified professional engineer responsible for its preparation. 2. Panel elevations, sections, plans, details, dimensions, joint treatment, and reinforcing fastening devices, and relation to adjacent construction. 3. Thickness of facing, GFRC backing, and bonding pads. 4. Finishes. 5. Joint and connection details. 6. Lifting and erection details. 7. Cold-formed metal framing layout and details. 8. Location and details of connection hardware attached to structure. 9. Size, location, and details of flex, gravity, and seismic anchors. 10. Other items sprayed into panels. 11. Sequence of erection for special conditions. 12. Relationship to adjacent materials. 13. Description of loose, cast-in, and field hardware. BOKA Powell Project No. 6671-06082 03490-1 08 February 2007

C. Samples for Selection: Submit sample of manufacturer s available textures for Architect s selection. D. Samples for Verification: Representative of finished exposed face of GFRC showing the full range of colors and textures expected, 12 by 12 inches(300 by 300 mm) and of appropriate thickness. E. Welding Certificates: Copies of certificates for welding procedures and personnel. F. Qualification Data: For firms and persons specified in "Quality Assurance" Article to demonstrate their capabilities and experience. Include lists of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified. 1.6 QUALITY ASSURANCE A. Installer Qualifications: An experienced installer who has completed GFRC panels similar in material, design, and extent to that indicated for this Project and whose work has resulted in construction with a record of successful in-service performance. B. Manufacturer Qualifications: A firm that complies with the following requirements and is experienced in manufacturing GFRC panels similar to those indicated for this Project and with a record of successful in-service performance. 1. Assumes responsibility for engineering GFRC panels to comply with performance requirements. This responsibility includes preparation of Shop Drawings and comprehensive engineering analysis by a qualified professional engineer. a. Professional Engineer Qualifications: A professional engineer who is legally qualified to practice in jurisdiction where Project is located and who is experienced in providing engineering services of the kind indicated. Engineering services are defined as those performed for installations of GFRC panels that are similar to those indicated for this Project in material, design, and extent. 2. Participates in PCI's Plant Certification Program and is designated a PCI-Certified Plant for Group G, Glass Fiber Reinforced Concrete. 3. Has sufficient production capacity to produce required units without delaying the Work. C. Testing Agency Qualifications: An independent testing agency qualified according to ASTM E 329 to conduct the testing indicated, as documented according to ASTM E 548. D. Welding: Qualify procedures and personnel according to AWS D1.1, "Structural Welding Code- -Steel," and AWS D1.3, "Structural Welding Code--Sheet Steel." E. Fire-Test-Response Characteristics: Where GFRC panels are part of a fire-resistance-rated assembly, provide panels identical to those used in assemblies tested per ASTM E 119 by a testing and inspecting agency acceptable to authorities having jurisdiction. 1. Fire-Resistance Requirements: Indicated by design designations from UL's "Fire Resistance Directory," from ITS's "Directory of Listed Products," or from the listings of another testing and inspecting agency. F. PCI Manuals: Comply with requirements and recommendations in the following PCI manuals, unless more stringent requirements are indicated: 1. PCI MNL 128, "Recommended Practice for Glass Fiber Reinforced Concrete Panel." 2. PCI MNL 130, "Manual for Quality Control for Plants and Production of Glass Fiber Reinforced Concrete Products." G. AISI Specifications: Comply with AISI's "Specification for the Design of Cold-Formed Steel Structural Members" or "Load and Resistance Factor Design Specification for Cold-Formed Steel Structural Members" for calculating structural characteristics of cold-formed metal framing. H. Mockups: Before installing GFRC, build mockups for each form of construction and finish required to verify selections made under sample Submittals and to demonstrate aesthetic effects and qualities of materials and execution. Build mockups to comply with the following requirements, using materials indicated for the completed Work: 1. Build mockups in the location and of the size indicated or, if not indicated, as directed by Architect. 2. Notify Architect seven days in advance of dates and times when mockups will be constructed. BOKA Powell Project No. 6671-06082 03490-2 08 February 2007

3. Demonstrate the proposed range of aesthetic effects and workmanship. 4. Obtain Architect's approval of mockups before starting installation. 5. Maintain mockups during installation in an undisturbed condition as a standard for judging the completed Work. 6. Demolish and remove unacceptable mockups when directed. 7. Approved mockups may become part of the completed Work if undisturbed at time of Substantial Completion. I. Preinstallation Conference: Conduct conference at Project site to comply with requirements in Division 1 Section "Project Meetings." 1.7 DELIVERY, STORAGE, AND HANDLING A. Handle and transport units to avoid excessive stresses or damage. 1. Lift or support units only at points indicated on Shop Drawings. 2. Ship in specially built crates. 3. Place nonstaining resilient spacers of even thickness between units. 4. Support units during shipment on nonstaining shock-absorbing material. 5. Protect units from dirt, damage, moisture, and warpage during handling and transport. B. Store units to protect from contact with soil, staining, moisture, physical damage, and other jobsite hazards. 1. Once uncrated, store material in upright position on flat, smooth, and level surface. 2. Avoid stacking and leaning of pieces. Cover and protect. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 1. Architectural Cladding Systems, Inc., Hollis, NH. 2. GFRC Cladding Systems, Inc., Garland, TX. 3. Casting Designs, Inc. (CDI) 4. Clark-Pacific, West Sacramento, CA. 5. Pineapple Grove Designs, Delray Beach, FL. 2.2 MOLD MATERIALS A. Molds: Rigid, dimensionally stable, nonabsorptive material, warp and buckle free, that will provide continuous and true GFRC surfaces; nonreactive with GFRC and capable of producing required finish surfaces. 1. Mold-Release Agent: Commercially produced liquid-release agent that will not bond with, stain, or adversely affect GFRC surfaces and will not impair subsequent surface treatments of GFRC. B. Form Liners: Units of face design, texture, arrangement, and configuration indicated. Provide solid backing and form supports to ensure that form liners remain in place during concreting. Furnish with manufacturer's recommended liquid-release agent that will not bond with, stain, or adversely affect concrete surfaces and will not impair subsequent surface treatments of GFRC. 2.3 GFRC MATERIALS A. Portland Cement: ASTM C 150, Type I. 1. For surfaces exposed to view in finished structure, use white of same type, brand, and source throughout GFRC production. B. Glass Fiber Reinforcement: Long-strand continuous glass fiber mats. 1. Glass Fibers: Alkali resistant, with a minimum zirconia content of 16 percent, 1 to 2 inches(25 to 50 mm) long, specifically produced for use in GFRC, and complying with PCI MNL 130. BOKA Powell Project No. 6671-06082 03490-3 08 February 2007

C. Sand: Washed and dried silica, successfully used in GFRC production, complying with composition requirements of ASTM C 144; passing No. 20(0.85-mm) sieve with a maximum of 2 percent retained on No. 140(0.10-mm) sieve. D. Facing Aggregate: ASTM C 33 and PCI MNL 130, with coarse aggregate complying with Class 5S requirements, 3/8-inch(10-mm) nominal maximum size. 1. Coarse Aggregates: Selected, hard, and durable; free of material that reacts with cement or causes staining; uniformly graded. 2. Fine Aggregates: Selected, natural, or manufactured sand of same material as coarse aggregate, unless otherwise approved by Architect. E. Water: Potable; free from deleterious material that may affect color stability, setting, or strength of GFRC and complying with chemical limits of PCI MNL 130. F. Curing Admixture: Acrylic thermoplastic copolymer dispersion complying with PCI MNL 130. G. Air-Entraining Admixture: ASTM C 260, containing not more than 0.1 percent chloride ions. H. Chemical Admixtures: ASTM C 494, containing not more than 0.1 percent chloride ions. 2.4 ANCHORS AND SUBSYSTEMS A. Carbon-Steel Shapes and Plates: ASTM A 36/A 36M. B. Carbon-Steel Rods: ASTM A 108, AISI 1018, cold drawn. C. Carbon-Steel Plate: ASTM A 283/A 283M. D. Malleable-Steel Castings: ASTM A 47(ASTM A 47M). E. Carbon-Steel Castings: ASTM A 27/A 27M, Grade 60-30(Grade 415-205). F. Bolts: ASTM A 307 or ASTM A 325(ASTM F 568M or ASTM A 325M). G. Finish: Zinc coated by hot-dip process according to ASTM A 123/A 123M, after fabrication, and ASTM A 153/A 153M, as applicable. H. Reglets: Stainless steel. 2.5 PANEL FRAME MATERIALS A. Cold-Formed Metal Framing: Manufacturer's standard C-shaped steel studs, complying with ASTM C 955, minimum uncoated steel thickness of 0.0538 inch(1.37 mm), punched, with stiffened flanges, U-shaped steel track, and of the following steel sheet: 1. Steel Sheet: ASTM A 653/A 653M, structural-steel sheet, G90(Z275) zinc coating, of grade required by structural performance of framing but not less than Grade 40(275). B. Structural Tubing: ASTM A 500, Grade B, or ASTM A 513, finished as follows: 1. Hot-Dip Galvanized: ASTM A 123/A 123M. C. Steel Channels and Angles: ASTM A 36/A 36M, finished as follows: 1. Hot-Dip Galvanized: ASTM A 123/A 123M. 2.6 GFRC MIXES A. Backing Mix: Proportion backing mix of portland cement, glass fibers, sand, and selected admixtures to comply with design requirements, and as follows. Provide nominal glass-fiber content of not less than 5 percent. 1. Flexural Properties: Average yield strength of 900 psi(6 MPa), and average ultimate strength of 2200 psi(15 MPa) at 28 days; ASTM C 947. 2. Maximum Water-Cementitious Ratio: 0.35. 3. Curing Admixture: 4 to 5 percent of total mix volume. B. Face Mix: Proportion face mix of portland cement, fine and coarse aggregates, and selected admixtures to comply with design requirements, and as follows: 1. Moisture Absorption: 6 percent maximum; ASTM C 948. 2. Air Content: 3 to 10 percent; ASTM C 231. 2.7 PANEL FRAME FABRICATION A. Fabricate panel framing and accessories plumb, square, true to line, and with connections securely fastened, according to Shop Drawings and requirements in this Section. 1. Fabricate framing assemblies using jigs or templates. 2. Install framing members in one-piece lengths. BOKA Powell Project No. 6671-06082 03490-4 08 February 2007

3. Cut cold-formed metal framing members by sawing or shearing; do not torch cut. 4. Fasten cold-formed metal framing members by welding. Comply with AWS D1.3 requirements and procedures for welding, appearance and quality of welds, and methods used in correcting welding work. 5. Fasten structural-steel framing members by welding. Comply with AWS D1.1 requirements and procedures for welding, appearance and quality of welds, and methods used in correcting welding work. 6. Weld flex, gravity, and seismic anchors to panel framing. B. Reinforce, stiffen, and brace framing assemblies to withstand handling, delivery, and erection stresses. Lift fabricated assemblies to prevent damage or permanent distortion. C. Repair Painting: Touch up accessible damaged galvanized surfaces according to ASTM A 780. 2.8 MOLD FABRICATION A. Construct molds that will result in finished GFRC complying with profiles, dimensions, and tolerances indicated, without restraining shrinkage or damaging GFRC during stripping. Construct molds to prevent water leakage and loss of cement paste. 1. Coat contact surfaces of molds with form-release agent. 2. Coat contact surfaces of molds with form retarder. B. Place form liners accurately to provide finished surface texture indicated. Provide solid backing and supports to maintain stability of liners during GFRC application. Coat form liner with formrelease agent. 2.9 GFRC FABRICATION A. Physical Properties: 1. Glass Fiber: 5-6 percent by weight. 2. Shell Thickness: 3/8 inch nominal. 3. Weight: Plus or minus 4 lbs./ft. 4. Density: 115.7 lbs./ft. 5. Tensile Strength, ASTM D 790: 1110 psi. 6. Flexural Strength, ASTM D 790: 2590. 7. Compressive Strength, ASTM D 695: 9520. 8. Impact, ASTM D 256 12.51 ft. lbs./in. B. Proportioning and Mixing: For backing mix, meter sand/cement slurry and glass fibers to spray head at rates to achieve desired mix proportion and glass content according to PCI MNL 130 procedures. C. Spray Application: Comply with general procedures as follows: 1. Spray face mix in thickness indicated on Shop Drawings. 2. Proceed with spraying up backing mix skin before face mix has set, using procedures that produce a uniform thickness and even distribution of glass fibers and matrix. 3. Consolidate backing mix by rolling or use another technique to achieve complete encapsulation of glass fibers and compaction. 4. Measure thickness with a pin gage or another acceptable method at least once for each 5 sq. ft.(0.5 sq. m) of panel surface. Take not less than six measurements per panel. BOKA Powell Project No. 6671-06082 03490-5 08 February 2007

D. Hand form intricate details, incorporate formers or infill materials, and over spray before material reaches initial set to ensure complete bonding. E. Attach panel frame to GFRC before initial set of GFRC backing, maintaining a minimum clearance of 1/2 inch(13 mm) from GFRC backing, and without anchors protruding into GFRC backing. F. Build up homogeneous GFRC bonding pads over anchor legs, maintaining a minimum thickness of 1/2 inch(13 mm) over top of anchor foot, before initial set of GFRC backing. G. Inserts and Embedments: Build up homogeneous GFRC bosses or bonding pads over inserts and embedments to provide sufficient anchorage and embedment to comply with design requirements. H. Curing: Employ initial curing method that will ensure sufficient strength for removing units from mold. 1. After initial curing, remove panel from mold and place in a controlled curing environment. 2. Keep panels continuously moist for a minimum of seven days. Maintain temperature between 60 and 120 deg F(16 and 49 deg C) during this period. 3. An acrylic thermoplastic copolymer dispersion may be used as a curing compound in lieu of moist curing. Use only copolymers shown, in published independent laboratory test data, to eliminate the need for moist curing of GFRC. I. Panel Identification: Mark each GFRC panel to correspond with identification mark on Shop Drawings. Mark each panel with its casting date. 2.10 FABRICATION TOLERANCES A. Manufacturing Tolerances: Manufacture GFRC units so each finished panel complies with the following dimensional tolerances. For dimensional tolerances not listed below, comply with PCI MNL 130. 1. Dimension all directions: Plus or minus 3/16 inch. 2. Thickness: 3/8 inch plus or minus 1/8 inch. 3. Warpage or bowing: 1/16 inch per foot. B. Position Tolerances: Measured from datum line locations, as indicated on Shop Drawings. 1. Panel Frame and Track: Plus or minus 1/4 inch(6 mm). 2. Flashing Reglets at Edge of Panel: Plus or minus 1/8 inch(3 mm). 3. Inserts: Plus or minus 1/2 inch(13 mm). 4. Special Handling Devices: Plus or minus 3 inches(75 mm). 5. Location of Bearing Devices: Plus or minus 1/4 inch(6 mm). 6. Block Outs: Plus or minus 3/8 inch(10 mm). C. Panel Frame Tolerances: As follows: 1. Vertical and Horizontal Alignment: 1/4 inch per 10 feet(6 mm per 3 m). 2. Spacing of Framing Member: Plus or minus 3/8 inch(10 mm). 3. Squareness of Frame: Difference in length of diagonals of plus or minus 3/8 inch(10 mm). 4. Overall Size of Frame: Plus or minus 3/8 inch(10 mm). 2.11 FINISHES A. Finish of Exposed-face Surfaces of GFRC Units: Smooth finish to receive painted finish in the field. 2.12 SOURCE QUALITY CONTROL A. Quality-Control Testing: Establish and maintain a quality-control program for manufacturing GFRC panels according to PCI MNL 130. 1. Test and inspect GFRC production. Include material acceptance testing, preproduction testing, aggregate production testing, wet production testing, and production testing after curing. BOKA Powell Project No. 6671-06082 03490-6 08 February 2007

PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions for compliance with requirements for installation tolerances, true and level bearing surfaces, and other conditions affecting performance. 1. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Provide lines, centers, grades, and marks for correct installation. 3.3 ERECTION A. Install clips, hangers, and other accessories required for connecting GFRC units to supporting members and backup materials. B. Lift GFRC units at lifting points established by manufacturer and install without damaging units. C. Install GFRC units level, plumb, square, and in alignment. Provide temporary supports and bracing as required to maintain position, stability, and alignment of units until permanent connections are completed. 1. Maintain horizontal and vertical joint alignment and uniform joint width. 2. Remove projecting hoisting devices. D. Anchor GFRC units in position by bolting or welding, or both, as indicated on Shop Drawings. Remove temporary shims, wedges, and spacers as soon as possible after anchoring is completed. E. Welding: Comply with AWS D1.1 and AWS D1.3 requirements and procedures for welding, appearance and quality of welds, and methods used in correcting welding work. 1. Protect GFRC units from damage by field welding or cutting operations, and provide noncombustible shields as required. F. At bolted connections, use lock washers or other acceptable means to prevent loosening of nuts. 3.4 ERECTION TOLERANCES A. Erect GFRC units to comply with the following noncumulative tolerances: 1. Plan Location from Building Grid Datum: Plus or minus 1/2 inch(13 mm). 2. Top Elevation from Nominal Top Elevation: As follows: a. Exposed Individual Panel: Plus or minus 1/4 inch(6 mm). b. Nonexposed Individual Panel: Plus or minus 1/2 inch(13 mm). c. Exposed Panel relative to Adjacent Panel: 1/4 inch(6 mm). d. Nonexposed Panel relative to Adjacent Panel: 1/2 inch(13 mm). 3. Support Elevation from Nominal Elevation: As follows: a. Maximum Low: 1/2 inch(13 mm). b. Maximum High: 1/4 inch(6 mm). 4. Maximum Plumb Variation over the Lesser of Height of Structure or 100 Feet(30 m): 1 inch(25 mm). 5. Plumb in Any 10 Feet(3 m) of Element Height: 1/4 inch(6 mm). 6. Maximum Jog in Alignment of Matching Edges: 1/4 inch(6 mm). 7. Maximum Jog in Alignment of Matching Faces: 1/4 inch(6 mm). 8. Face Width of Joint: As follows (governs over joint taper): a. Panel Dimension 20 Feet(6 m) or Less: Plus or minus 1/4 inch(6 mm). b. Panel Dimension More Than 20 Feet(6 m): Plus or minus 5/16 inch(8 mm). 9. Maximum Joint Taper: 3/8 inch(10 mm). 10. Joint Taper in 10 Feet(3 m): 1/4 inch(6 mm). 11. Differential Bowing, as Erected, between Adjacent Members of Same Design: 1/4 inch(6 mm). BOKA Powell Project No. 6671-06082 03490-7 08 February 2007

3.5 REPAIRS A. Repairs will be permitted provided structural adequacy of GFRC unit and appearance are not impaired, as approved by Architect. B. Blend and mix patching materials and repair GFRC so cured patches match color, texture, and uniformity of adjacent exposed surfaces. C. Prepare and repair damaged galvanized coatings on metal framing, anchors, and subsystems with galvanizing repair paint according to ASTM A 780. D. Remove and replace damaged GFRC units when repairs do not comply with requirements. 3.6 CLEANING AND PROTECTION A. Perform cleaning procedures according to GFRC manufacturer's written instructions. Clean soiled GFRC surfaces with detergent and water, using soft fiber brushes and sponges, and rinse with clean water. Prevent damage to GFRC surfaces and to adjacent materials. B. Provide final protection and maintain conditions that ensure GFRC is without damage or deterioration at time of Substantial Completion. END OF SECTION 03490 BOKA Powell Project No. 6671-06082 03490-8 08 February 2007